Loading...
HomeMy WebLinkAbout8505-INDUS-2008_FAR-FY17-183191 Pine Hall Road Walnut Cove, NC 27052 336-445-0610 July 18, 2018 Ms. Shawn McKee 1646 Mail Service Center Raleigh, NC 27699-1646 Subject: Duke Energy – Belews Creek Steam Station Permit Number 8505-INDUS FGD Landfill Industrial Waste Landfill Annual Report Dear Ms. McKee: Attached is the completed Industrial Landfill Annual Report form for Duke Energy’s Belews Creek Steam Station FGD Residual Landfill (Permit No. 8505) for the past year (7/1/2017 – 6/30/2018). The landfill only accepts waste from Duke Energy’s Belews Creek Steam Station. The FGD landfill had a gross acceptance of 38,595 tons over the most recent 12 months which was reduced by a removal (mining gypsum for sales) of 37,462.50 tons, resulting in a net disposal of 1,131.50 tons. The Facility Annual Report represents net monthly disposal amounts. Mining activities were conducted with the approval of the Solid Waste Section. Since the landfill went into operation and through the most recent survey on May 8, 2018, approximately 906,169 cubic yards and 1,270,364.16 tons of waste have been disposed in the landfill. As required by G.S. 130A-309.09D(b), the County Manager for any county that generated waste for disposal to this landfill is sent a copy of the Annual Report. Therefore, a copy of this Annual Report is being provided to the County Manager for Stokes County. If there are any questions regarding this report feel free to contact me at (336) 445-0610. Sincerely, Melonie Martin Environmental Services Att: Duke Energy Belews Creek FGD Landfill Facility Annual Report Duke Energy Belews Creek FGD Landfill Facility Annual Risk Assessment with Figure Cc: Keeley McCormick, Duke Energy - Belews Creek Steam Station Jeff Gateley, Duke Energy - Belews Creek Steam Station Jake Oakley, Stokes County - County Manager Industrial LF 2017 Page 1 Facility Name:Permit: Physical Address Street 1: Street 2: City: State:Zip: County: Mailing Address Street 1: Street 2: City: State:Zip: Primary Facility Contact Person Name: Phone:Fax: Email: Billing Contact Person Name: Phone:Fax: Email: 1.Tipping Fee: $per Ton (Attach a schedule of tipping fees if appropriate.) 3. Indicate types of disposal activity occurring at this facility (Check all that apply). Landfilling of industrial waste (specify waste): Landfilling of ash Landfilling of construction and demolition waste Landfilling of asbestos Landfilling of sludge Landfilling of other waste (specify): IND State of North Carolina Department of Environmental Quality Division of Waste Management According to G.S. 130A-309.09D(b), completed forms must be returned by August 1, 2018, and a copy of this report must be sent to the County Manager of each county from which waste was received. If you have questions or require assistance in completing this report, contact your Regional Environmental Senior Specialist. INDUSTRIAL WASTE LANDFILL Facility Annual Report For the period of July 1, 2017-June 30, 2018 4. What other activities occur at this facility? (check all that apply) Scrap Tire Collection White Goods Collection Household Hazardous Waste CollectionRecycling/Reuse Collection If you checked Recycling/Reuse Collection, please indicate the materials accepted: (check all that apply) Paper Wood Concrete/rubble/asphalt Gypsum/drywall Cardboard Glass Aluminum Cans Steel Cans PETE (#1) Plastic HDPE (#2) Plastic Computer Equipment Televisions Fluorescent lightbulbs Used oil/oil filters Other Metal Other Plastic Other (specify) Airspace (Capacity): Questions in this section relate to all cells/units of the facility operated under the current 4-digit permit number regardless of whether the cells/units are closed or are not contiguous at the time of this report. Tonnage questions must be based on scale records and cover the period between the opening date and the date of the last survey unless another time period is approved. Airspace measurements include weekly, intermediate and final cover. 5. Date Facility Last Surveyed: 7. Total Tons Disposed in Airspace Used (tons): 6. Airspace Used (cubic yards): 2. Did your facility stop receiving waste during this past Fiscal Year? Yes No If so, please report the date this occurred: (amount disposed in tons): 8505-INDUS Duke Energy - Belews Creek FGD Residue Landfill 8505-INDUS 3195 Pine Hall Road Belews Creek North Carolina 27009 Stokes 3195 Pine Hall Road Belews Creek North Carolina 27009 Melonie Martin (336) 445-0610 (336) 445-0423 Melonie.Martin@duke-energy.com Melonie Martin (336) 445-0610 (336) 445-0423 Melonie.Martin@duke-energy.com 0.00 CCR including but not limited to gypsum and bottom ash Note: Recycling activities occur at Belews Creek Steam Station not associated with the landfill May 8, 2018 1,270,364.16 906,169 Industrial LF 2017 Page 2 8. Total waste landfilled at this facility during the period of July 1, 2017, through June 30, 2018. Indicate tonnage received by COUNTY of waste origin. DO NOT include waste diverted for recycling, reuse, mulching, or composting. Please list ALL counties from which you received waste. Please indicate COUNTY and STATE, if received from another state. Received from Jul Aug Sept Oct Nov Dec Jan Feb Mar Apr May June Total Grand Total CERTIFICATION: I certify that the information provided is an accurate representation of the activity at this facility. Signature:Date: Name: Phone Number:Email: Title: REMINDER: According to G.S. 130A-309.09D(b), this report must be sent to the Regional Environmental Senior Specialist for your area and a copy of this report must be sent to the County Manager of each county from which waste was received. Please return your completed report to: Shawn McKee 1646 Mail Service Center Raleigh, NC 27699-1646 Telephone: 919.707.8284 Email: Shawn.McKee@ncdenr.gov 8505-INDUS Stokes County, NC 7,850 8,340 000020,944 0 -9,527.5 -24,864 -3,071 1,460 1,131.5 1,131.5 Melonie Martin (336) 445-0610 Melonie.Martin@duke-energy.com Lead Environmental Specialist Industrial LF 2017 Page 3 Instructions: NC DEQ Division of Waste Management - Solid Waste Section Risk Assessment Form Facility Name:Permit: Address: City:State:Zip: Date:Person completing Assessment: Phone Number:Fax:Email: Please indicate either Yes or No for each Receptor and Post Closure Maintenance question. Then please determine the distance or distances for each Receptor from the Edge of Waste (using range finders and/or GIS maps) and type that information into the form. Please attach additional information including GIS maps, lists of potable well locations, etc. Receptors 1. Are there Residential Structures Within 1,500 feet of the Edge of Waste?Yes No If Yes, how many? What are the three closest distances from the Edge of Waste?Feet Feet Feet 2. Are there Water Supply Wells Within 1,500 feet of the Edge of Waste?Yes No If Yes, how many? What are the three closest distances from the Edge of Waste?Feet Feet Feet 3. Are there Community/Municipal Wells Within 1,500 feet of the Edge of Waste?Yes No If Yes, how many? What are the three closest distances from the Edge of Waste?Feet Feet Feet 4. Are there Surface Water Features Within 1,500 feet of the Edge of Waste?Yes No If Yes, how many? What are the three closest distances from the Edge of Waste?Feet Feet Feet Please list the names of the water bodies: 5. Is Public Water Available Within 1,500 feet of the Edge of Waste?Yes No If Yes, how many of the Residential Structures noted above are connected? Corrective Measures 6. Is there an active methane extraction system (blower, flare, etc.)?Yes No 7. Is there a passive methane extraction system (trench, vents in cap, flare, etc.)?Yes No 8. Is there groundwater remediation taking place on site?Yes No If Yes, what is the specific remedial technology used? Comments 8505-INDUS Duke Energy - Belews Creek FGD Residue Landfill 8505-INDUS 3195 Pine Hall Road Belews Creek North Carolina 27009 Jun 19, 2018Julie Robertson (704) 382-4761 (704) 382-6240 Julie.Robertson@duke-energy.com 1 540 560 840 Belews Lake N/A, city water line route Waste streams identified on Page 1, Question 3 reflect disposal activities that occurred at this facility from July 1, 2017 through June 30, 2018. This landfill mines gypsum for sales which results in a negative net disposal amount. Duke Energy – Belews Creek FGD Residue Landfill Permit: 8505-INDUS LEGEND: Potable Well Within 1,500’ of Edge of Waste Surface Water Bodies Edge of Waste Belews Lake Belews Lake N FGD Landfill Permit No. 8505-INDUS