HomeMy WebLinkAbout6301_MooreCoCountyMSWLF_GWMR_20170316CATCH
BASIN
CATCH
BASIN
395360370375385390370355TO GP-9
CONSULTANT
DESIGN
PREPARED
REVIEW
APPROVED
YYYY-MM-DD TITLE
PROJECT No.Rev.
PROJECTCLIENT
Path: \\greensboro\CAD\_2007\0739615 - Moore\PRODUCTION\_A - 2015 GW Report\ | File Name: 0739615015B001.dwgIF THIS MEASUREMENT DOES NOT MATCH WHAT IS SHOWN, THE SHEET SIZE HAS BEEN MODIFIED FROM: ANSI D01 in0739615015
PHASE
100
DRAWING
10
2016-07-07
BSD
TJM
BSD
RPK
MOORE COUNTY LANDFILL
PERMIT NO. 63-01
ABERDEEN, NORTH CAROLINA
MOORE COUNTY
GROUNDWATER SURFACE CONTOUR MAP
APRIL 11, 2016
PERENNIAL STREAM
INTERMITTENT STREAM
EPHEMERAL STREAM
POND AND WETLAND LIMITS
EXISTING 10 FT GROUND SURFACE CONTOUR
EXISTING 2 FT GROUND SURFACE CONTOUR
PROPERTY LINE
APPROXIMATE LIMITS OF WASTE
EXISTING ROAD
POTENTIOMETRIC GROUNDWATER CONTOURS (5 FT. INTERVAL)
GROUNDWATER FLOW SEGMENTS
MONITORING WELL AND IDENTIFICATION
METHANE PROBE AND IDENTIFICATION
SURFACE WATER MONITORING POINT AND IDENTIFICATION
LANDFILL GAS TRENCH VENTS AND IDENTIFICATION
PASSIVE LANDFILL GAS VENTS
PRIVATE WELL LOCATION AND IDENTIFICATION
WETLAND AREA
LEGEND
NOTES
1.TOPOGRAPHIC CONTOUR INTERVAL = 2 FEET
2.GROUNDWATER SURFACE CONTOUR INTERVAL = 5 FEET
3.GROUNDWATER ELEVATIONS MEASURED ON APRIL 11, 2016.
4.GROUNDWATER CONTOURS BASED ON LINEAR INTERPOLATION BETWEEN AND
EXTRAPOLATION FROM KNOWN DATA, TOPOGRAPHIC CONTOURS, AND KNOWN FIELD
CONDITIONS. THEREFORE, GROUNDWATER CONTOURS MAY NOT REFLECT ACTUAL
CONDITIONS.
5.GROUNDWATER CONTOUR LINES SHOW THE WATER TABLE SHAPE AND ELEVATION. THESE
CONTOURS ARE INFERRED LINES FOLLOWING THE GROUNDWATER SURFACE AT A
CONSTANT ELEVATION ABOVE SEA LEVEL. THE GROUNDWATER FLOW DIRECTION IS
GENERALLY PERPENDICULAR TO THE GROUNDWATER SURFACE CONTOURS, SIMILAR TO THE
RELATIONSHIP BETWEEN SURFACE WATER FLOW AND TOPOGRAPHIC CONTOURS.
6.PROPERTY BOUNDARY SURVEY BY JAMES L. WRIGHT DATED NOVEMBER 1984. ITS LOCATION
IS RELATIVE TO TOPOGRAPHY APPROXIMATE BY HDR ENGINEERING, INC.
7.EXISTING TOPOGRAPHY WITHIN ACTIVE AND PROPOSED LANDFILL PROVIDED BY MATTHEWS
LAND SURVEYING & MAPPING, PLLC DATED APRIL 17, 2015.
8.MONITORING WELLS MW-1 THROUGH MW-5 SURVEYED JUNE 1987 BY S&ME, INC. MONITORING
WELLS MW-6 THROUGH MW-16 SURVEYED APRIL 1995, SEPTEMBER 1996, AND APRIL 2003 BY
HDR ENGINEERING INC./ ED BUCKNER RLS APRIL 17, 2015.
9.THE LOCATIONS OF LANDFILL GAS TRENCH VENTS ARE APPROXIMATE.
10.GROUNDWATER WELLS MW-11D, MW-13D, AND MW-16D ARE NOT SCREENED IN THE SHALLOW
AQUIFER AND ELEVATION DATA WERE NOT USED IN THE CONSTRUCTION OF GROUNDWATER
CONTOURS.
11.A STREAM DETERMINATION WAS CONDUCTED ON APRIL 17, 2013 BY A GOLDER ASSOCIATES
NC, INC. REPRESENTATIVE. THE STREAM DETERMINATION WAS CONDUCTED USING NCDWQ'S
"METHODOLOGY FOR IDENTIFICATION OF INTERMITTENT AND PERENNIAL STREAMS AND
THEIR ORIGINGS, VERSION 4.11".
SITE LOCATION MAP
NOT TO SCALE
SITE LOCATION
0
FEET
200 400
SCALE
2650 East 40th Avenue
Denver, CO 80205
(800) 833-7958 Fax:(303) 322-7242
Calibrated at Geotech's Colorado service center
Gem 2000+ Calibration Certificate
Cleaned Unit and Case
Visually inspect for damage and missing parts
Manual is in case.
Battery charge 100 %
Pump flow 400 ml/min Pass
Pass
Gas Zered
CH₄ 0 %
CO₂ 0 %
CO 0 ppm
H₂S 0 ppm
O₂ 0 %
0 %
0.1 %
0 ppm
0 ppm
0 %
Zero Gas
Ambient Air
Ambient Air
Ambient Air
Ambient Air
Gem Gas
Variance
0.00%Pass
0.00%Pass
0.10%Pass
0.00%Pass
0.00%Pass
Zero
ReadingZero
Gas Spaned
CH₄ 15 %
CO₂ 15 %
CO 50 ppm
H₂S 10 ppm
O₂ 20.9 %
Reading
15 %
15 %
50 ppm
10 ppm
20.9 %
Calibration Gas
Gem Gas
Gem Gas
Ambient Air
Variance
0.00%
0.00%
0.00%
Pass
Pass
Pass
4 Gas0.00%Pass
4 Gas0.00%Pass
Span
Span
Not Applicable
Not Applicable
Not Applicable
Not Applicable
Not Applicable
Unit Number:2439 Field Calibration Date:2/2/2017 12:01 PM
Technician:Larry LundbergSerial Number:#Name?
Pass
Exp. Date
10/19
Pass
Pass
Pass
Pass
Lot #
16-5710
Lot #
16-5710
16-5710
16-5717
16-5717 10/18
10/18
10/19
Exp. Date
10/19
Factory Calibration Date:8/14/2015
Geotech Environmental Equipment, Inc. takes pride in ensuring this instrument is tested to function as
specified by the manufacturer and was calibrated in accordance to manufacturer specifications. All
calibration standards used are NIST traceable. With the provided lot numbers we can provide NIST
documents on request. Call us at (800) 833-7958 and we will be glad to help.