Loading...
HomeMy WebLinkAbout9215T_INSP_20180531FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 1 of 3 UNIT TYPE: Lined MSWLF LCID YW Transfer X Compost SLAS COUNTY: WAKE Closed MSWLF HHW White goods Incin T&P FIRM PERMIT NO.: 9215T-TRANSFER-1994 CDLF Tire T&P / Collection Tire Monofill Industrial Landfill DEMO SDTF FILE TYPE: COMPLIANCE Date of Site Inspection: May 31, 2018 Date of Last Inspection: March 10, 2016 FACILITY NAME AND ADDRESS: Waste Management of Raleigh-Durham Transfer Station 10411 Globe Road Morrisville, NC 27560 GPS COORDINATES: N: 35.89289 W: -78.80482 FACILITY CONTACT NAME AND PHONE NUMBER: James Woodard, Waste Management-District Manager 919-405-7497(office), 919-815-0149(mobile) jwoodard@wm.com PARTICIPANTS: Liz Patterson, NCDEQ – Solid Waste Section Andrew Harkins – Waste Management STATUS OF PERMIT: PTC: January 18, 1994 PTO: August 29, 1994 PTO-Amendment: August 9, 1995 PTO-Amendment: November 13, 1996 PTO-Amendment: September 16, 2005 PTO-Modification Letter: December 12, 2008 PTO-Amendment: October 21, 2010 Permit Expires: October 21, 2015 PTO-Amendment: June 2, 2016 PURPOSE OF SITE VISIT: Comprehensive Inspection STATUS OF PAST NOTED VIOLATIONS: NONE OBSERVED VIOLATIONS: NONE The item(s) listed above were observed by Section staff and require action on behalf of the facility in order to come into or maintain compliance with the Statutes, Rules, and/or other regulatory requirements applicable to this facility. Be advised that pursuant to N.C.G.S. 130A-22, an administrative penalty of up to $15,000 per day may be assessed for each violation of the Solid Waste Laws, Regulations, Conditions of a Permit, or Order under Article 9 of Chapter 130A of the N.C. General Statutes. Further, the facility and/or all responsible parties may also be subject to enforcement actions including penalties, injunction from operation of a solid waste management facility or a solid waste collection service and any such further relief as may be necessary to achieve compliance with the North Carolina Solid Waste Management Act and Rules. FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 2 of 3 ADDITIONAL COMMENTS This facility is a solid waste transfer facility that is permitted to receive solid waste as defined in NCGS 130A-290 (a)(35). The following must not be accepted at this facility: hazardous waste, yard trash, liquid wastes, regulated medical waste, sharps not properly packaged, regulated-asbestos containing material. Wastes banned from landfill disposal in North Carolina by NCGS 130A-309.10 (f) must not be transferred for landfill disposal. The current permit was issued June 2, 2016. The permit expiration date is October 21, 2020. 1. The facility is permitted to receive municipal solid waste generated within Alamance, Chatham, Durham, Franklin, Granville, Johnston, Orange, Vance, Wake, and Wayne Counties. Waste transferred for disposal must go to the Sampson County Landfill located in Roseboro, Permit Number 82-02. 2. The facility is permitted to operate from 6:00 am to 7:00 pm Monday through Saturday but current hours during which waste is accepted are typically 6:00 am to 5:00 pm. 3. Signs stating emergency information, facility name, permit number, and other required information are installed at the facility entrance gate and adjacent to the facility scale. 4. The facility site plan and operations plan were readily available. 5. Waste screening reports were verified from January 5, 2018 through May 30, 2018. Random inspections are occurring weekly. The facility does not receive many unacceptable waste items. All prohibited/unacceptable items are loaded back onto the incoming truck and hauled out of the facility. 6. The Certified Transfer Station Operators are: Marion McLeod, III – TS-2013070, expires June 21, 2019 Sam Mufaro – TS-2011010, expires February 9, 2020 7. Waste on the tipping floor was being managed in accordance with the facility Permit to Operate and approved Operations Plan. No unacceptable items were observed at the time of the inspection. Tipping floor 8. The facility is permitted to recover old corrugated cardboard (OCC). The OCC is not currently being separated at the facility. 9. There were 2 fire extinguishers on walls beside the tipping floor, 1 extinguisher behind the push wall, and 1 extinguisher in the trailer tunnel. 10. Leachate is collected in a 3000-gallon above ground tank. The liquid is hauled as needed by a contractor. The tank had last been emptied on May 29, 2018 by Heritage-Crystal Clean, LLC. FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 3 of 3 11. The grate covering the leachate collection sump was in place at the time of the inspection. Loading Bay & Leachate collection trench 12. Excess waste in the loading bay is cleaned up after every load. 13. The area behind the push wall and the area adjacent to the door was being well maintained and is routinely cleaned. 14. The perimeter walls of the transfer station are being maintained in a clean, sanitary condition. Good job! 15. Windblown waste at the site was very well controlled. Windblown material resulting from the operation is collected and properly disposed of at the conclusion of each day of operation. Please contact me if you have any questions or concerns regarding this inspection report. Phone: 919-707-8286(O) elizabeth.patterson@ncdenr.gov Liz Patterson Environmental Senior Specialist Regional Representative Sent on: 6-4-2018 X Email Hand delivery US Mail Certified No. [ _] Copies: Drew Hammonds, Eastern District Supervisor - Solid Waste Section