Loading...
HomeMy WebLinkAbout09034_Pelton Crane_Decision_memo_CLT 20100621 DRAFT DECISION MEMORANDUM FROM: Carolyn Minnich TO: BF Assessment File DATE: June 21, 2010 RE: Former Pelton-Crane Facility- CLT Sidewalk Installation 200 Clanton Road, Charlotte, Mecklenburg County BF # 09034-05-60 On Friday, June 18, 2010, NCDENR Brownfields Program was notified by Doug Pierotti of the City of Charlotte Engineering Department via e-mail about soil disturbance activities for a sidewalk installation along 200 Clanton Road. The following is his message: We are planning to build new sidewalk along 200 Clanton, former Pelton & Crane Brownfield site. A concern is a catch basin that will be set to about 7.5' below grade. This is near 3 wells (MW-10, MW-17 & MW-22).Do you have a recent report with depth to groundwater and sampling of these wells? There appears to be a shallow water table and TCE impact in these wells which could be a concern to catch basin CB-19 and the 15" RCP to CB-18. See attached map. Contaminated Media: Groundwater is contaminated above unrestricted use levels ( NC 2L GW Stds) with volatile organics. The site is currently being addressed in DENR’s REC Program and the Responsible Party (RP), Siemens, has accepted responsibility. NBP LUR #d prohibit the use of groundwater use at the property and LUR #e prohibits the movement of soil without notification. Potential Receptors: Workers (construction/outdoor) Groundwater contaminants (in micrograms per liter, the equivalent of parts per billion), the standards for which are in Title 15A of the North Carolina Administrative Code, Subchapter 2L, Rule .0202: Wells of interest include MW-9, MW-10, MW-17, MW-22 Groundwater Contaminant Sample Location Date of Max. Concentration Sampling Max. Concentration above Std. (µg/L) Date of Most Recent Sampling Concentration at most Recent Sampling Event (µg/L) Standard (µg/L) TCE MW-9 11/27/01 16 05/26/05 3.2 2.8 TCE MW-10 11/27/01 380 05/29/05 150 2.8 TCE MW-17 05/07/01 170 05/27/05 45 2.8 TCE MW-22 03/04/02 6.3 05/27/05 0.33J 2.8 Methyl Chloride MW-10 07/15/02 9.7 05/29/05 ND 5 Bromomethane MW-10 07/15/02 3.7J 05/29/05 ND 1.8 Zinc (Total) MW-17 08/23/01 9,630 07/15/02 598 2,100 J=estimated laboratory value ND=not detected above laboratory detection limit Soil: No soil impacts are known in this area, nor was it an area of concern in past investigations. Required Land Use Restrictions: d. No activities that encounter, expose, remove or use groundwater (for example, installation of water supply wells, fountains, ponds, lakes or swimming pools, or construction or excavation activities that encounter or expose groundwater) may occur on the Property without prior sampling and analysis of groundwater to the written satisfaction of DENR in any areas proposed for such activities, and submittal of the analytical results to DENR. If such results disclose to DENR contamination in excess of North Carolina’s groundwater quality standards, the proposed activities may not occur without the prior written approval of DENR on such conditions as DENR imposes, including at a minimum compliance with plans and procedures, approved pursuant to applicable law, to protect public health and the environment during the proposed activities. This Land Use Restriction does not apply to remedial activities sanctioned by DENR. e. Other than in connection with mowing and pruning of above-ground vegetation, soil on the Property may not be disturbed unless DENR has been given ten (10) days written notice (electronic mail suffices), during which period DENR may issue a written determination (electronic mail suffices) that prior sampling has been inadequate to allow the soil disturbance to proceed without additional sampling. Within 21 days after any such determination, DENR shall issue written instructions regarding additional sampling. If sampling results disclose contamination that DENR determines renders the Brownfields Property unsuitable for the uses specified in subparagraph 14.a. above, the soil may only be exposed or disturbed in conformance with plans, approved in writing in advance by DENR, for protection of public health and the environment while the soil is exposed or disturbed, and if as much soil as DENR requires is removed and disposed of in accordance with applicable law, or covered with an impervious or hard pervious surface to DENR’s written satisfaction, in which case the cover shall be maintained in good repair to DENR's satisfaction. Information that meets with DENR's written satisfaction regarding the transportation and disposition of any soil removed from the Brownfields Property must be supplied in a letter report to DENR within ninety (90) days following removal. This Land Use Restriction does not apply to remedial activities sanctioned by DENR. Well Type Installed Out casing Depth Gr elev TOIC Screen Zone GW map elevation 8/10/04 DTW estimate MW-9 2” PVC 4/01 NA 27 725.45 725.16 17-27 Soils 719.27 6.18 MW-10 2” PVC 4/01 NA 36 721.96 721.77 26-36 Soils 716.33 5.63 MW-17 Open borehole 8/01 6”/39 ft 59 721.87 721.16 39-59 shallow bedrock 715.6 6.27 MW-22 Open borehole 8/01 10”/42 ft 6”/100 ft 162 724.20 722.06 100-162 Deep bedrock 716.05 8.15 Recommendation: Prepare HASP or work plan addressing groundwater impacts and how they will be handled. This is to include proper PPE, containerization, disposal, monitoring, and other areas as needed.