HomeMy WebLinkAboutNC0001058_Draft Permit_20191002 ROY COOPER rknr,i„n _ti"^: MICHAEL S. REGAN y - Secretary LINDA CULPEPPER NORTH CAROLINA Environmental Quality October 02, 2019 Ms.Natalie Brown Patheon Manufacturing Services LLC PO Box 1887 Greenville,N.C. 27835 Subject: DRAFT NPDES PERMIT NC0001058 DSM Pharmaceuticals Inc. Grade I PC WPCS [15A NCAC 08G .0306] Pitt County Dear Ms. Brown: Enclosed with this letter is a copy of the draft permit for your facility. Please review the draft very carefully to ensure thorough understanding of the conditions and requirements it contains. Your permit is among several in the Tar-Pamlico River Basin that the Division has targeted for expedited renewal. This draft contains the following changes from the existing permit: • Regulatory citations for permit requirements have been added throughout the permit. • HUC and stream index#have been added to the outfall description on the supplement to cover page. • The eDMR requirements section (Part 1 Section A (3)) has been updated to be consistent with the finalization of federal requirements for electronic reporting. With this notification, the Division will solicit public comment on this draft permit by publishing a notice in newspapers having circulation in the general Pitt County area, per EPA requirements. Please provide your comments,if any,to me no later than 30 days after receiving this draft permit. Following the 30-day public comment period,the Division will review all pertinent comments and take appropriate action prior to issuing a final permit. If you have questions concerning the draft, please contact me via email at [emily.delduco@ncdenr.gov] or call 919-707-9125. Sincerely, ie,4e.„ Lae_ Emily DelDuco Environmental Specialist II NPDES Program Cc:NPDES Files Ec: Washington Regional Office North Carolina Department of Environmental Quality I Division of Water Resources 1617 Mail Service Center I Raleigh,North Carolina 27699-1617 919-707-9125 Permit NC0001058 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION OF WATER RESOURCES PERMIT TO DISCHARGE WASTEWATER UNDER THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Patheon Manufacturing Services LLC is hereby authorized to discharge wastewater from a facility located at Patheon Manufacturing Services U.S. Highway 13 North @ U.S. Highway 11 & 264 Bypass Greenville Pitt County to receiving waters designated as Parkers Creek in subbasin 03-03-05 of the Tar-Pamlico River Basin in accordance with effluent limitations,monitoring requirements, and other conditions set forth in Parts I, II, III, and IV hereof. This permit shall become effective ---- This permit and authorization to discharge shall expire at midnight on October 31, 2024. Signed this day---- Linda Culpepper, Director Division of Water Resources By Authority of the Environmental Management Commission 1 of 7 Permit NC0001058 SUPPLEMENT TO PERMIT COVER SHEET All previous NPDES Permits issued to this facility,whether for operation or discharge are hereby revoked.As of this permit issuance,any previously issued permit bearing this number is no longer effective.Therefore,the exclusive authority to operate and discharge from this facility arises under the permit conditions,requirements,terms,and provisions included herein. Patheon Manufacturing Services, LLC, is hereby authorized to: 1. Continue to discharge non-contact cooling water from a facility located at the intersection of U.S. Highway 13 North and U.S. Highway 11 &264 Bypass in Pitt County. 2. Discharge from said treatment works (via Outfall 001 and 002) into Parkers Creek [HUC: 030201030404; Stream Index #: 28-95], currently a class C-NSW water in the Tar-Pamlico River Basin, at the location specified on the attached map. � fr 2 of 7 Permit NC0001058 Part I A. (1) EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS [15A NCAC 02B.0400 et seq.,02B.0500 et seq.] Grade 1 Physical Chemical WPCS [[15A NCAC 08G.0306] Beginning on the effective date of this permit and lasting until expiration,the Permittee is authorized to discharge non-contact cooling water from Outfall 001 and 002. Such discharges shall be limited and monitored' by the Permittee as specified below: EFFLUENT LIMITATIONS MONITORING REQUIREMENTS PARAMETER [EDMR CODE] Monthly Daily Measurement Sample Sample Average Maximum Frequency Type Location2 Flow Effluent Monthly Instantaneous [50050] Total Residual Chlorine(TRC)3 [50060] Monthly Grab Effluent Temperature,°C Monthly Grab Effluent [00010] pH >6.0 and<9.0 standard units Monthly Grab Effluent [0 [00400] Footnotes: 1. The permittee shall submit discharge monitoring reports electronically using the Division's eDMR system [see A. (3)]. 2. Effluent monitoring requirements apply only if non-contact cooling water is discharged via Outfalls 001/002. If non-contact cooling water is not discharged during a particular month,the permittee should indicate"No Flow" on the submitted Discharge Monitoring Report(DMR). Effluent Sampling Point=Outlet of the cooling tower blowdown,prior to comingling with the other waste streams. 3. TRC monitoring requirements apply only if chlorine is added to the cooling tower. The Division shall consider all effluent TRC values reported<50 µg/L to be in compliance with the permit. However,the Permittee shall continue to record and submit all values reported by a North Carolina certified laboratory (including field certified), even if these values fall below 50 µg/L. 4. The temperature of the effluent shall not cause an increase in the temperature of the receiving stream of more than 2.8°C,and in no case cause the ambient water temperature to exceed 32°C. THERE SHALL BE NO DISCHARGE OF FLOATING SOLIDS OR VISIBLE FOAM IN OTHER THAN TRACE AMOUNTS. 3 of Permit NC0001058 A. (2) BIOCIDE CONDITION There shall be no chromium,zinc or copper added to the treatment system except as pre-approved additives to biocidal compounds. The permittee shall obtain approval from the Division's Aquatic Toxicology Unit prior to the use of any biocide (not previously approved by the Division)in the effluent discharged under this permit. Approval for use of any biocide not previously approved should be requested at least 90 days in advance of any planned usage. Contact the Aquatic Toxicology Unit for detailed instructions on requesting approval of biocides: NC DENR/DWR/Aquatic Toxicology Unit 1621 Mail Service Center Raleigh,North Carolina 27699-1621 A. (3) ELECTRONIC REPORTING OF DISCHARGE MONITORING REPORTS [G.S. 143-215.1(B)] Federal regulations require electronic submittal of all discharge monitoring reports (DMRs) and program reports. The final NPDES Electronic Reporting Rule was adopted and became effective on December 21, 2015. NOTE: This special condition supplements or supersedes the following sections within Part II of this permit (Standard Conditions for NPDES Permits): • Section B. (11.) Signatory Requirements • Section D. (2.) Reporting • Section D. (6.) Records Retention • Section E. (5.) Monitoring Reports 1. Reporting Requirements [Supersedes Section D. (2.) and Section E. (5.) (a)1 The permittee shall report discharge monitoring data electronically using the NC DWR's Electronic Discharge Monitoring Report(eDMR) internet application. Monitoring results obtained during the previous month(s) shall be summarized for each month and submitted electronically using eDMR. The eDMR system allows permitted facilities to enter monitoring data and submit DMRs electronically using the internet. Until such time that the state's eDMR application is compliant with EPA's Cross-Media Electronic Reporting Regulation (CROMERR), permittees will be required to submit all discharge monitoring data to the state electronically using eDMR and will be required to complete the eDMR submission by printing, signing, and submitting one signed original and a copy of the computer printed eDMR to the following address: NC DEQ/Division of Water Resources/Water Quality Permitting Section ATTENTION: Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 4 of 7 Permit NC0001058 access,then a temporary waiver from the NPDES electronic reporting requirements may be granted and discharge monitoring data may be submitted on paper DMR forms (MR 1, 1.1, 2, 3)or alternative forms approved by the Director. Duplicate signed copies shall be submitted to the mailing address above. See"How to Request a Waiver from Electronic Reporting" section below. Regardless of the submission method, the first DMR is due on the last day of the month following the issuance of the permit or in the case of a new facility, on the last day of the month following the commencement of discharge. Starting on December 21,2020,the permittee must electronically report the following compliance monitoring data and reports,when applicable: • Sewer Overflow/Bypass Event Reports; • Pretreatment Program Annual Reports; and • Clean Water Act(CWA) Section 316(b)Annual Reports. The permittee may seek an electronic reporting waiver from the Division(see"How to Request a Waiver from Electronic Reporting"section below). 2. Electronic Submissions In accordance with 40 CFR 122.41(1)(9), the permittee must identify the initial recipient at the time of each electronic submission. The permittee should use the EPA's website resources to identify the initial recipient for the electronic submission. Initial recipient of electronic NPDES information from NPDES-regulated facilities means the entity (EPA or the state authorized by EPA to implement the NPDES program)that is the designated entity for receiving electronic NPDES data [see 40 CFR 127.2(b)]. EPA plans to establish a website that will also link to the appropriate electronic reporting tool for each type of electronic submission and for each state. Instructions on how to access and use the appropriate electronic reporting tool will be available as well. Information on EPA's NPDES Electronic Reporting Rule is found at: http://www2.epa.gov/compliance/final-national-pollutant- discharge-elimination-system-npdes-electronic-reporting-rule. Electronic submissions must start by the dates listed in the"Reporting Requirements"section above. 3. How to Request a Waiver from Electronic Reporting The permittee may seek a temporary electronic reporting waiver from the Division. To obtain an electronic reporting waiver, a permittee must first submit an electronic reporting waiver request to the Division. Requests for temporary electronic reporting waivers must be submitted in writing to the Division for written approval at least sixty(60) days prior to the date the facility would be required under this permit to begin submitting monitoring data and reports. The duration of a temporary waiver shall not exceed 5 years and shall thereupon expire. At such time,monitoring data and reports shall be submitted electronically to the Division unless the permittee re-applies for and is granted a new temporary electronic reporting waiver by the Division. Approved electronic reporting waivers are not transferrable. Only permittees with an approved reporting waiver request may submit monitoring data and reports on paper to the Division for the period that the approved reporting waiver request is effective. 5 of 7 Permit NC0001058 Information on eDMR and the application for a temporary electronic reporting waiver are found on the following web page: http://deq.nc.gov/about/divisions/water-resources/edmr 4. Signatory Requirements [Supplements Section B. (11.) (b) and Supersedes Section B. (11.) (d)1 All eDMRs submitted to the permit issuing authority shall be signed by a person described in Part II, Section B. (11.)(a) or by a duly authorized representative of that person as described in Part II, Section B. (11.)(b). A person, and not a position,must be delegated signatory authority for eDMR reporting purposes. For eDMR submissions,the person signing and submitting the DMR must obtain an eDMR user account and login credentials to access the eDMR system. For more information on North Carolina's eDMR system,registering for eDMR and obtaining an eDMR user account,please visit the following web page: http://deq.nc.gov/about/divisions/water-resources/edmr Certification. Any person submitting an electronic DMR using the state's eDMR system shall make the following certification [40 CFR 122.22]. NO OTHER STATEMENTS OF CERTIFICATION WILL BE ACCEPTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." 5. Records Retention [Supplements Section D. (6.11 The permittee shall retain records of all Discharge Monitoring Reports, including eDMR submissions. These records or copies shall be maintained for a period of at least 3 years from the date of the report. This period maybe extended by request of the Director at any time [40 CFR 122.41]. 6of7 I 'f1.6• •- � , i V Burning Sush \ ` 1 /,� l 1 Ch , 7 2.3 y4 7 T `,\ • 2 -[:;.C. i''' # • a. • •u k if •„,,_42, �,pt ,•�• ' O y 1 ` • io p -. », =� Sc�16 1 Ns 1 J= 1 U t=K...._____, i ,,,,N ..., f• 1 • U Trailer •. f.; �_,_�.._.� �_ Park 1!1�1` l M1 -" '" ,,'' 1 J / _ �°. industri: �leste �. ro Disposal! ti I p , \�, .1( I L���t.� OUTFACE �� r O OUTFALL `'j it \ l , ' I I ool 2 , -,,,,.. c:------" N — -...w_-_,N \ i) 7 �\Or :T I . !In.,ern °. IV.' l ❑� �c -. K _ �1 '.....,, "ti \ I ' ® _ . 1 - ) " `---/•-' `/ ) '1 AO �`�. PF ► __ .. _o_ ,...---_-- ----'-'-_- , -.::,_:,..L..— -:,----- _ _ _.. _____ / 1\ : �y, _ JI y 1 �. III / / ! - ..• oa �. /✓ • \\ ,l'� 4 e Q\c. �� .....1•'•':-•--...-•,. +� , GREEN ' <y ._ -„=_-_-=, ; Patheon Manufacturing Services LLC FACILITY County: Pitt Stream Class: C-NSW I LOCATION Receiving Stream: Parker Creek Sub-Basin: 03-03-05 (not to scale) Latitude(001): 35°39'30" USGS Quad: Greenville NE ... Longitude(001): 77°21'29" Latitude(002): 35°39'20" Longitude(002): 77°21'24" ,/vat NPDES Permit NC0001058 7 of 7