September 27, 2019
Subject: Compliance Inspection
Permit No. WQ0023178
Town of Clayton Residuals
Land Application Program
Johnston County
Staff of NC Division of Water Resources (DWR), Water Quality Regional Operations Section
(WQROS), Raleigh Regional Office (RRO) observed delivery and application of wastewater
residuals from the Town of Clayton WQ0023178 Residuals Land Application Permit on
September 25, 2019. James Warren, ORC, Johnnie Smith and Jonathan Smith assisted with the
inspection. Jonathan was operating the transfer pump and land application tractor and
equipment for Triple S Farms which is contracted to do the hauling and land application under
permit WQ030998. The application fields are owned by Triple S farms and are located outside of
Beaulaville.
The facility uses a drum thickener to generate about 360 to 400,000 gallons of 2.5 to 3% residuals
per month. These residuals can be land applied or they can be turned to cake with a rented belt
press. Cake can be land applied, or send to the Johnston County landfill or sent to McGilI for their
composting process. Liquid can also be brought to the landfill, but it is expensive.
The residuals were lime stabilized in the digester tank at the Clayton Wastewater Recovery
Facility. pH was maintained above 12 for at least two hours and remained above 10.5 until
transported for application. Vector attraction reduction is accomplished by incorporating the
residuals.
A copy of the permit which was issued May 19, 2015 and expires September 30, 2020 was
maintained on -site in the cab of the tractor application equipment. O&M procedure and Spill Plan
was available in both transport trucks and on -site. Proper signs were posted at the access road
to the fields.
_ m North Carolina Departent of nt Environmeal quality ; Division of Water Resources
D� E Q� RalcigltReglanal Officv 1 3800 Barrel Drive i Raleigh. North Carolina 27609
IAtTIIMll �f inWtllM.wMMt�iM\ 41111 '1111 1'II\I\
The transfer into on -site tanker pulled by tractor with balloon tires indicated minimal dripping
during tranfer operations. The field was properly flagged.
The residuals analyses appeared compliant with permit requirements. Nutrient loadings were
monitored and records maintained.
There was no odor noted at the held. The fields were sufficiently dry to prevent excess
compaction by application equipment. The residuals were adequately dispersed so as to prevent
ponding or runoff. The fields were covered with healthy grass crop which has been properly
maintained.
This residuals application event appeared to be fully compliant with permit requirements and
personnel were aware of processes to be performed to assure compliance.
Please refer to the attached inspection report. If you have any questions or would like technical
assistance, please contact me via email at ray.milosh@ncdenr.gov or at (919) 791-4240.
Sincerely,
Ray Milosh
Environmental Specialist
ray.milosh@ncdenr.gov
Attachment: Inspection Report
cc: RRO-WQROS Files
Water Quality Section Central Files
Compliance Inspection Report
Permit: WQ0023178 Effective: 10/01/15 Expiration, 09r30120 owner. Town of Clayton
SOC: Effective: Expiration_ Facility: Town of Clayton Residuals Land Application Progran
County: Johnston
Region: Raleigh
Contact Person: G. F. Baker Title: Phone: 336-288-7169
Directions to Facility:
System Classifications: LA
Primary ORC: James O Warren Certification: 17618 Phone: 919-553-1536
Secondary ORC(s):
On -Site Representative(s):
Related Permits -
Inspection Date: 09/25/2019 Entry Time: 08 30AM Exit Time: 12 30PM
Primary Inspector: Raymond M Mdosh Phone: 919-791-4200
Secondary Inspector(s):
Reason for Inspection: Routine
Permit Inspection Type: Land Application of Residual Solids (503)
Facility Status: Compliant Not Compliant
Question Areas:
Miscellaneous Questions Record Keeping
Pathogen and Vector Attracticr. Transport
(See attachment summary)
Inspection Type: Compliance Evaluation
Land Application Site
Page 1 of 5
Permit- W00023178 Owner - Facility: Town or Clayton
Inspection Date,• 09/2512019 Inspection Type : Compliance Evaluation reason for Visit: Routine
Inspection Summary:
Staff of NC Division of Water Resources (DWR), Water Quality Regional Operations Section (WOROS), Raleigh Regional
Office (RRO) observed delivery and application of wastewater residuals from the Town of Clayton WQ0023178 Residuals
Land Application Permit on September 25. 2019_ James Warren, ORC, Johnnie Smith and Jonathan Smith assisted with
the inspection. Jonathan was operating the transfer pump and land application tractor and equipment for Triple S Farms
which is contracted to do the hauling and land application under permit WQ030998. The application fields are owned by
Triple S farms and are located outside of Beaulaville.
The facility uses a drum thickener to generate about 360 to 400,000 gallons of 2.5 to 3% residuals per month. These
residuals can be land applied or they can be turned to cake with a rented belt press. Cake can be land applied, or send to
the Johnston County landfill or sent to McGill for their composting process. Liquid can also be brought to the landfill, but it
is expensive.
The residuals were lime stabilized in the digester tank at the Clayton Wastewater Recovery Facility. pH was maintained
above 12 for at least two hours and remained above 10.5 until transported for application. Vector attraction reduction is
accomplished by incorporating the residuals.
A copy of the permit which was sssued May 19. 2015 and expires September 30, 2020 was maintained on -site in the cab of
the tractor application equipment. O&M procedure and Spill Plan was available in both transport trucks and on -site. Proper
signs were posted at the access road to the fields.
The transfer into on -site tanker pulled by tractor with balloon tires indicated minimal dripping during tranfer operations. The
field was properly flagged_
The residuals analyses appeared compliant with permit requirements. Nutrient loadings were monitored and records
maintained_
There was no odor noted at the field. The fields were sufficiently dry to prevent excess compaction by application
equipment. The residuals were adequately dispersed so as to prevent ponding or runoff. The fields were covered with
healthy grass crop which has been properly maintained.
This residuals application event appeared to be fully compliant with permit requirements and personnel were aware of
processes to be performed to assure compliance.
Page 2 of 5
Permit W00023176 Owner - Facility: Town of Claytin
Inspection Date: 09/2512019 Inspection type : Ccmp:lance EvalLation
Reason for Visit: Routine
Type
Yes No NA NE
Distribution and Marketing
Land Application
■
Record Keeping
Yes No NA NE
Is GW monitoring being conducted, if required?
Are GW samples from all MWs sampled for all required parameters?
Are there any GW quality violations?
■ri
Is GW-59A certification form completed for facility?
■
Is a copy of current permit on -site?
■ 0 1:1 El
Are current metals and nutrient analysis available?
.
Are nutrient and metal loading calculating most limiting parameters?
N El El El
a. TCLP analysis?
■
b. SSFA (Standard Soil Fertility Analysis)?
■ ❑
Are PAN balances being maintained?
■
Are PAN balances within permit limits?
■
Has land application equipment been calibrated?
❑ ■
Are there pH records for alkaline stabilization?
■
Are there pH records for the land application site?
■
Are nutrient/crop removal practices in place?
❑ 1:1 El
Do lab sheets support data reported on Residual Analysis Summary?
Are hauling records available?
■
Are hauling records maintained and up-to-date?
El El 1:1
# Has permittee been free of public complaints in last 12 months?
Has application occurred during Seasonal Restriction window?
❑ ❑
Comment:
Pathogen and Vector Attraction
Yes No NA NE
a. Fecal coliform SM 9221 E (Class A or B)
.
Class A, all test must be <i 000 MPNIdry gram
Geometric mean of 7 samples per monitoring period for class B<2.0'10E6 CFUIdry gram
IJ
Fecal coliform SM 9222 D (Class B only)
. El
Geometric mean of 7 samples per monitoring period for class B<2.0`1 DE6 CFU/dry gram
0
b. pH records for alkaline stabilization (Class A)
c. pH records for alkaline stabilization (Class B)
0❑
❑
Temperature corrected
d. Salmonella (Class A, all test must be < 3MPN/4 gram day)
.rl
Page 3 of 5
permit: VV00023178 owner - Facility: Town of Clayton
inspection pate: 0912512019 Inspection Type :Compliance Evaluation Reason for Visit: Routine
e Timerremp on: ❑ ❑ E ❑
Digester (MCRT) ❑
Compost ❑
Class A time stabilization ❑
f. Volatile Solids Calculations ❑ ❑ 0 ❑
g. Bench -top Aerobic/Anaerobic digestion results ❑ ❑ M ❑
Comment:
Transport Yes No NA HE
Is a copy of the permit in the transport vehicle? 0 ❑ ❑ ❑
Is a copy of the spill control plan in the vehicle? E ❑ ❑ ❑
Is the spill control plan satisfactory? M ❑ 1111
Does transport vehicle appear to be maintained? 0 ❑ ❑ ❑
Comment:
Land Application -Site
Yes No NA NE
Is a copy of the permit on -site during application events?
0 ❑ ❑ ❑
Is the application site in overall good condition?
M ❑ ❑ ❑
Is the site free of runoff/pond.ng?
M ❑ ❑ ❑
If present is the application equipment in good operating condition?
M ❑ ❑ ❑
Are buffers being maintained?
M ❑ ❑ ❑
Are limiting slopes buffered?
1 a% for surface application
0 ❑ 1311
18% for subsurface application
M ❑ ❑ ❑
Are there access restrictions and/or signs?
M, ❑ ❑ ❑
Is the application site free of odors or vectors?
❑ ❑ ❑
Have performance requirements for application method been met?
For injection?
❑ ❑ ❑
For incorporation?
E ❑ ❑ ❑
Does permit require monitoring welts?
❑ ❑ M ❑
Have required MWs been installed?
❑ ❑ 0 ❑
Are MWs properly located wt respect to RB and CB?
❑ ❑ M ❑
Are MWs properly constructed (including screened interval)?
❑ ❑ M ❑
Is the surrounding area served by public water?
❑ ❑ 0 ❑
If Annual Report indicates overapplication of PAN are wells nearby that may be impacted?
❑ ❑ M ❑
Are soil types consistent wt Soli Scientist report/evaluation?
❑ ❑ ❑
Is the water table greater than 173' his
❑ ❑ ❑ M
Is application occurring at the time of the inspection?
M ❑ ❑ ❑
Page 4 of 5