HomeMy WebLinkAboutNCG080608_COMPLETE FILE - HISTORICAL_20071003STORMWATER DIVISION CODING SHEET
NCG PERMITS
PERMIT NO. I /v C&,O� b � (%
DOC TYPE I X HISTORICAL FILE
❑ MONITORING REPORTS
DOC DATE ❑ 0
YYYYM M DD
Michael F. Easley, Governor
William G. Ross Jr., Secretary
North Carolina Department of Environment and Natural Resources
October 3, 2007
Mr. Ed Cornwell
Service Center Manager
FedEx Freight
646 Roycroft Road
Creedmoor, NC 27522
SUBJECT: Stormwater Compliance Evaluation Inspection
FedEx Freight - RDU
Permit No: NCG080608
Granville County
Dear Mr. Cornwell :
Coleen H. Sullins, Director
Division of Water Quality
F �►)L
i AVA IN
Your help on October 1, 2007 in reviewing the Fed Ex facility stormwater program with me was
appreciated. It was a pleasure meeting you. Attached is a checklist from the inspection for your
review. Your facility was compliant with the permit, with these comments:
• Following the details in Part II of the permit concerning the stormwater manual, please combine the
materials from two notebooks into one. That will be less confusing and the resulting manual can become a
repository for documentation that accumulates each year -- such as quarterly monitoring records, employee
training, an updated list of responsible parties, notes on any spills and annual reviews of the manual. The
manual should hold five years' worth of data in any given year when Division inspections are made.
• Training specific to stormwater was not documented, yet regular Flaz Mat training for spill response
covers the most important aspect of stormwater awareness for this facility. Training should be broadened to
cover all employees. This will sensitize everyone to avoid and report pollution of stormwater.
Sincerely,
�y 0" �'!
Myrl A. Nisely
Environmental Chemist
Raleigh Regional Office
cc: SWP/RRO Files
Central Files
Raleigh Regional Office 1628 Mail Service Center
Water Quality Section Raleigh, NC 27699-1628
AT T7
RiC6ERR
phone (919791-4200 Customer Service
facsimile (919) 788-7159 1-800-623-7748
Permit: NCGO80608
SOC:
County: Granville
Region: Raleigh
Compliance Inspection Report
Effective: 09/01/02 Expiration: 08/31107 Owner: Fedex Freight East Inc
Effective: Expiration: Facility: Fedex Freight - RDU
646 Roycro€t Rd
E) X-C
Contact Person: Ftartdell—Rerwil
Directions to Facility:
System Classifications:
Primary ORC:
Secondary ORC(s):
On -Site Representative(s):
Related Permits:
Inspection Date: 10101/2007
Primary Inspector: Myrl Nisely
Secondary Inspector(s):
Title:
Entry Time: 01:05 PM
Creedmoor NC 27522
Phone: 800-874-4723
Certification
Exit Time: 01 A5 PM
Phone:
Phone: 919-791-4200
Reason for Inspection: Routine Inspection Type: Stormwater
Permit Inspection Type: Transportation wlVehicle Maintenance/Petroleum Bulk/Oil
Water Se Orator Stormwater Discharge COC
Facility Status: ■ Compliant Not Compliant
Question Areas:
0 Storm Water
(See attachment summary)
Page: 1
Permit: NCGO80608 Owner - Facility: Fedex Freight East Inc
inspection Date: 10/01/2007 Inspection Type: Stormwater
Reason for Visit: Routine
Stormwater Pollution Prevention Plan
Yes
No
NA NE
Does the site have a Stormwater Pollution Prevention Plan?
■
❑
❑ ❑
# Does the Plan include a General Location (USGS) map?
■
❑
❑ ❑
# Does the Plan include a "Narrative Description of Practices"?
■
❑
❑ ❑
# Does the Plan include a detailed site map including outfall locations and drainage areas?
■
❑
❑ Cl
# Does the Plan include a list of significant spills occurring during the past 3 years?
■
❑
❑ ❑
# Has the facility evaluated feasible alternatives to current practices?
■
❑
❑ ❑
# Does the facility provide all necessary secondary containment?
■
❑
❑ n
# Does the Plan include a BMP summary?
■
❑
❑ Cl
# Does the Plan include a Spill Prevention and Response Plan (SPRP)?
■
❑
Cl ❑
# Does the Plan include a Preventative Maintenance and Good Housekeeping Plan?
■
❑
❑ ❑
# Does the facility provide and document Employee Training?
❑
■
❑ Cl
# Does the Plan include a list of Responsible Party(s)?
■
❑
❑ ❑
# Is the Plan reviewed and updated annually?
❑
■
❑ ❑
# Does the Plan include a Stormwater Facility Inspection Program?
■
❑
❑ ❑
Has the Stormwater Pollution Prevention Plan been implemented?
■
❑
❑ ❑
Comment: Need to broaden training to specifically cover stormwater awareness, and
include all employees so everyone knows pollution when they see it and can respond
appropriately. Drivers currently receive Haz Mat and spill response/cleanup training.
Provide a page in the manual documenting the annual training. The plan showed
evidence of activity up to the present, but did not document that the plan had been
reviewed annually, Please note the reviews in the future.
Qualitative Monitoring
Yes
No
NA NE
Has the facility conducted its Qualitative Monitoring semi-annually?
■
❑
❑ ❑
Comment: Monitoring quarterly per FedEx guidelines. This exceeds the semi-annual
monitoring requred by the permit.
Analytical Monitoring
Yes
No
NA NE
Has the facility conducted its Analytical monitoring?
❑
❑
■ ❑
# Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas?
❑
❑
■ ❑
Comment:
Permit and Outfalls
Yes
No
NA NE
# Is a copy of the Permit and the Certificate of Coverage available at the site?
■
❑
n ❑
# Were all outfalls observed during the inspection?
■
❑
❑ ❑
Page. 3
Permit: NCG080608 Owner -Facility: Fedex Freight East Inc
Inspection pate: 10/01/2007 Inspection Type: Stormwater Reason for Visit: Routine
# if th e facility has representative outfall status, is it properly documented by the Division? n n Tl
# Has the facility evaluated all illicit (non stormwater) discharges?
Comment
Page, 4