Loading...
HomeMy WebLinkAboutNCS000389_MONITORING INFO_20061215STORMWATER DIVISION CODING SHEET NCS PERMITS PERMIT NO. A j GIZ6 oo0 37 DOC TYPE ❑ FINAL PERMIT C2� MONITORING REPORTS ❑ APPLICATION 0 COMPLIANCE ❑ OTHER DOC DATE ❑ 2 oc>{-e YYYYM M DD DAKAmericas ;aHBERS. MONOMERS & RESINS < <. December-1 S, 2006,,. REF: NPDES Permit No. NCS000389 Division of Water Quality N. C? DENR 1617 Mail Service Center Raleigh N.C. 27699-1617 ATTN: Central Files Dear Sirs: Enclosed are the Stormwater discharge,monitoring•reports submitted by DAK Americas for.your records., These results represent the Analytical Monitoring Requirements for year 471' quarter sampling as detailed in NPDES Permit No. NCS000389 Table 2 Part Il page Sincerely, - Donald Allbright ORC - CERI'IFTED MAIL N 7002 2030 0002 8853, 9310 Permit Numbe : NCS000389 . STORMWATER DISCHARGE OUTFALL MONITORING REPORT SAMPLES COLLECTED DURING CALENDAR YEAR: 2006 FACILITY NAME DAK RESINS LLC PERSON COLLECTING SAMPLE(S) DONALD ALLBRIGHT CERTIFIED LABORATORY(S) TBL Lab# 37 Paradigm Anal ical Laboratories INC. LAB# 481 Part A: Specific Monitoring Requirements COUNTY CUMBERLAND PHONE NO. 910 4 3-8 27 (SIGNATUR OF PERMITTEE OR DESIGNEE) By this signature, I certify that this report is accurate complete to the best of my knowledge. Outfall No. Date Sample Collected 50050 00340 82388 Total Flow COD 1,4 DIOXANE molddlyr MG MGIL MGIL 003 11 /8/2006 1 1.2 1 195 0.00792 Does this facility perform Vehicle Maintenance Activities using more than 55 gallons of new motor oil per month? yes X no STORM EVENT CHARACTERISTICS: Date 11/8/2006 Total Event Precipitation (inches): 1_8 Event duration (hours): 24 Mail Original and one copy to: Division of Water Quality Attn: Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 " I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the Information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, Including the possibility of fines and imprisonment for knowing violations. (Signature of Permittee) STORMWATER DISCHARGE OUTFALL MONITORING REPORT Permit Numb r�t)38SAMPLES COLLECTED DURING CALENDAR YEAR: 2006 FACILITY NAME DAK RESINS LLC COUNTY CUMBERLAND PERSON COLLECTING SAMPLE(S) DONALD ALLBRIGHT PHO 910 433-822 CERTIFIED LABORATORY(S) TBL Lab# 37 420 Paradigm Analytical Laboratories _INC._ LAB#_48 f (SIGNATUR PERMITTEE OR DESIGNEE) By this signature, I certify that this report is accurate complete to the best of my knowledge. Part A: Specific Monitoring Requirements Outfall No. Date Sample Collected 50050 00340 82388 Total Flow COD 1,4 DIOXANE molddlyr MG MGIL MG1L 003 11/8/2005 1 1.2 1 195 0.00792 Does this facility perform Vehicle Maintenance Activities using more than 55 gallons of new motor oil per month? yes X no STORM EVENT CHARACTERISTICS: Date 11/8/2006 Total Event Precipitation (inches): 1.8 Event duration (hours): 24 Mail Original and one copy to: Division of Water Quality Attn: Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 " I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted Is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false Information, including the possibility of fines and imprisonment for knowing violations. (Signature of Permittee) .. : I DAK Americas FIBERS, MONOMERS & RESINS To: NCDENR, DWQ From: DAK Americas, LLC (Anthony Hudson) Subject: NPDES # NCS000389, Analytical Monitoring Date: 9-21-05 DAK Americas operates under NPDES Permit NCS000389 for its Cedar Creek operations near Fayetteville, North Carolina. The permit requires that samples be collected at Outfall 003 after a qualifying rainfall event. Given the weather over the past several months, there have been little opportunity to collect samples, as there have been few qualifying rainfall events. On July 29, 2005, however, there was a qualifying rain event, and thus, a routine monitoring sample was taken from Outfall 003. The laboratory we use for the storm water samples was sent the samples for analysis for chemical oxygen demand (COD) and 1,4-dioxane, in accordance with the specifications of the permit. The outside lab provided a verbal report of the results: COD analysis of 2,040 mg/L and total dioxin. (We received written analysis of Outfall 003 sample on 9-6-05.) The COD results were remarkable, given our typical levels; for example, based on previous samples, the average COD from Outfall 003 is 13 mg/L, meaning the results reported verbally were about 200 times the typical or expected results. Further, the laboratory reported results for dioxin, where we had requested (as per our permit) analysis for 1,4-dioxane. There appeared to be some confusion between the primary laboratory and subcontracted laboratory around the target compound for the second analysis, conducting an analysis of the sample for dioxin rather than 1,4-dioxane. The laboratory stated they could use the remaining water sample to complete an analysis for 1,4-dioxane, were it not for the duration between collection, analysis, and follow-up analysis. The sample collected during the qualified rain event was, by then, "out of hold date" and would have to be prepared differently, which could alter test results. We elected to have the sample, even though beyond the normally accepted hold time, analyzed -for 1,4-dioxane and prepare for a back-up sample to be collected from Outfall 003 during the next qualifying rain event. The results of the analysis of this initial sample was BDL, which is consist with historical results. Given the magnitude of the COD result from the sample collected, we immediately conducted a visual search of the site for potential contamination that may have entered the storm water drain system. Our thesis was that anything that contributed to such an abnormal COD result would be visibly evident at one '.di . i "..� of the storm water drains.`Nb visible detection of any contaminate that would DAK Americas LLC 3216 Cedar Creek Road • PO Box 1690 (28302) - Fayetteville, NC 28312 410-433-8300 - fax: 910-433-8366 contribute to such an abnormal COD level was found throughout the site. Site logbooks were checked and no documented incident around the storm water drains had been recorded during the time period when the sample was collected. Our storm water collection system includes a retention basin which allows us to normalize flow to the outfall. The contents of this retention basin would, therefore, be representative of the water that is directed to the outfall. The site collected another water sample from the storm water retention pond, which feeds directly to Outfall 003, and sent it to the same outside laboratories for analyses for COD and 1, 4-dioxane. The laboratory again verbally provided the results for COD of 13.3 mg/L and 1,4-dioxane of BDL. These results are expected, being consistent with the historical results of analyses of samples from Outfall 003. The site believes the original sample is invalid based on: • The results of the visual inspection for potential contamination at storm water drains and ■ The results of the sample from the retention basin being in the normal range for samples from Outfall 003. The site will resample Outfall 003 during the next rain event to ensure that parameters in the water discharging Outfall 003 are within acceptable limits provided in the permit. These results will be provided to NCDENR when available. If additional information or actions are required please contact me at 910433-8338. STORMWATER DISCHARGE OUTFALL (SDO) MONITORING REPORT Permit Number: NC S000389 or SAMPLES COLLECTED DURING CALENDAR YEAR: 2003 Certificiate of Coverage Number: NCG (This monitoring report shall be received by the Division no later than 30 days from the date the facility receives the sampling results from the laboratory) FACILITY NAME DAK Resins, LLC, Cedar Creek Site PERSON COLLECTING SAMPLE(S Jamie Honeycutt (S&ME, Inc.) CERTIFIED LABORATORY (S) Compuchem. Laborato!j Lab # 79 Lab # r8rt A: bnecine ivionitorme xeautrements Outfal.1 Date' 50050 No. Sample Total A 4 Collected, Flow. Djo'xane C'OD...:;,i .17..- 'MG mg/LL" mo/dd/yr 003 11/19/2003 0.71 <0.025 17 COUNTY Cumberland P77E NUMBE� (910 433-8331 f adz-4.9 (SPNATURE OF PERMITTEIr OR DESIGNEE) j4y this signature, I certify, that this report is accurate and complete to the best of my knowledge. Does this facility perform Vehicle Maintenance Activities using more than 55 gallons of new motor oil per month? (if yes, complete Part B) cart B: Vehicle Maintenance Activity MonitorInar Heouirements Outfau Date 1 50050- 00556:,:1it� 00530'1[ 711.1� No. Oil 0 an i3l: rjr;,�*;. 1 �: 3 jr 1 '!4`� H P New Motor: Collected ow. Flow" !Grease.�.-_! S uspended 16i I Usage.` i-AbIL'; mo/dd/ MG )4� '.14"I'unit L-L,., _` ! .. allmo.. 003 n/a ___yes _4_no Form SWU-246-051 100 Pagel of STORM EVENT CHARACTERISTICS: Date: _11/19/03 Total Event Precipitation (inches): _1 Event Duration (hours): _Z (if more than one storm event was sampled) Date: Total Event Precipitation (inches): Event Duration (hours): Mail Original and one copy to: Division of Water Quality Attn: Central Files 1617 Mail Service Center Raleigh, NC 27699-16I7 "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of tines and imprisonment for knowing violations." C. ,, -k ", - (Signature rmittee) !L-(�+-r (Date) Form SWU-246-051100 Page 2 of 2 STORMWATER DISCHARGE OUTFALL (SDO) MONITORING REPORT Permit Number: NCS000389 or SAMPLES COLLECTED DURING CALENDAR YEAR: 2004 Certificate of Coverage Number: NCG (This monitoring report shall be received by the Division no later than 30 days from the date the facility receives the sampling results from the laboratory.) FACILITY NAME DAK RESINS LLC COUNTY CUMBERLAND PERSON COLLECTING SAMPLE(S) DONALD ALLBRIGHT PHON NO. 91 -43 8227 CERTIFIED LABORATORY(S) TBL Lab# 37 - Z-1 0� Environmental Science Corp Lab# ENV 375 (SIGNATU F PERMITTEE OR DESIGNEE) By this signature, I certify that this report is accurate complete to the best of my knowledge. Part A: Specific Monitoring Requirements Outfall No. Date Sample Collected 50050 00340 82388 Total Flow COD 1,4,DIOXANE molddlyr MG MGlL MGIL 003 61412004 1 0.218 13.3 1 <.10 Does this facility perform Vehicle Maintenance Activities using more than 55 gallons of new motor oil per month? yes X no STORM EVENT CHARACTERISTICS: Date 614104 Total Event Precipitation (inches):.3 Event duration (hours): .67 Mali Original and one copy to: Division of Water Quality Attn: Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 " I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. i am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations. (Signature of Permittee) (Date) .