HomeMy WebLinkAboutNC0073393_Inspection_20190814EPA United States Environmental Protection Agency Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 N 52 NC0073393 19/08/14 C S31112171819 20 21 66 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA ----------------------Reserved------------------- N67707172 73 74 75 80 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Dana Hill WWTP 1010 Dana Rd Hendersonville NC 28792 Entry Time/Date Permit Effective Date Exit Time/Date Permit Expiration Date 03:15PM 19/08/14 16/02/01 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Kenneth Jason Rummel/ORC/828-697-0063/ Other Facility Data 03:45PM 19/08/14 20/11/30 Name, Address of Responsible Official/Title/Phone and Fax Number Vito Montaperto,1010 Dana Rd Hendersonville NC 28792//828-692-8477/8286921759 Contacted No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Flow Measurement Operations & Maintenance Self-Monitoring Program Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s)Agency/Office/Phone and Fax Numbers Date Daniel J Boss ARO WQ//828-296-4658/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page#1 DocuSign Envelope ID: 1656C315-FDBD-4756-8CCB-694719171E1B 9/9/2019 9/9/2019 NPDES yr/mo/day 19/08/14 Inspection Type C3111218 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) On 8/14/2019 I (Daniel Boss) conducted a follow up inspection at the Dana Hill WWTP. I met with Jason Rummel (ORC) and Juanita James for the inspection. The blowers still do not have guards covering the belts. This is a safety hazard and needs to be corrected. The composite sampling is still not flow proportional. The flow meter readout is now working, and the meter has been calibrated recently. NC0073393 17 Page#2 DocuSign Envelope ID: 1656C315-FDBD-4756-8CCB-694719171E1B Permit:NC0073393 Inspection Date:08/14/2019 Owner - Facility: Inspection Type: Dana Hill WWTP Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Aeration Basins Yes No NA NE Mode of operation Ext. Air Type of aeration system Diffused Is the basin free of dead spots? Are surface aerators and mixers operational? Are the diffusers operational? Is the foam the proper color for the treatment process? Does the foam cover less than 25% of the basin’s surface? Is the DO level acceptable? Is the DO level acceptable?(1.0 to 3.0 mg/l) The belts on the blowers are not covered. This is a safety hazard.Comment: Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? Is flow meter calibrated annually? Is the flow meter operational? (If units are separated) Does the chart recorder match the flow meter? The flow meter display is working again.Comment: Effluent Sampling Yes No NA NE Is composite sampling flow proportional? Is sample collected below all treatment units? Is proper volume collected? Is the tubing clean? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type representative)? Page#3 DocuSign Envelope ID: 1656C315-FDBD-4756-8CCB-694719171E1B Permit:NC0073393 Inspection Date:08/14/2019 Owner - Facility: Inspection Type: Dana Hill WWTP Compliance Evaluation Effluent Sampling Yes No NA NE The sampling is still not flow proportional. Mrs. James says that it's been difficult to find someone to do the electrical work needed to connect the sampler to the flow meter. Comment: Page#4 DocuSign Envelope ID: 1656C315-FDBD-4756-8CCB-694719171E1B