Loading...
HomeMy WebLinkAbout20170359 Ver 2_COMBINED_HS-STEWART_75%_20190826GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA LOCH DORNIE DREDGING / ISLAND ENHANCEMENT AND LINVILLE RIVER STABILIZATION DESIGN LOCATION MAP NOT TO SCALE 75% DESIGN - DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 HAZEN NO.: 32453-002 STEWART NO.: L19013 AUGUST 2019 STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 XOO O O O O O O O O OOOOOOOXXASPHALT ASPHALTGREENTRAPTRAP TRAPTRA P NGS CM DAM N:865903.95 E:1157252.32 EL:3795.64 IS L A N D D R I V E LOC H D O R NI E D RI V E CLUBHOUSE DRIVEWOODCHUCK ROAD CLUB H O U S E D R I V E CLUBHOUSE DRIVECLUBHOUSE DRIVECLUBHOUSE DRIVE CLUBHOUSE DRIVE CLUBHOUSE DRIVE C L U B H O U S E D R I V E ISLAND DRIVE ISLAND D R I V E LINVI L L E R I V E R EX. WL EX.WL WO O D F E N C E L O D LODLODLODLODLODLODLODLODLO D LODL O D LOD L O D LODLODLODLODLODLODLODLODLODLODLODLODLOD LODLOD LODLODLOD LO D LODLODLODLODLODLODLODLODLOD LODLODLODLODLODLODLODLODLODL O D LODLOD LOD L O D LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD L O D LOD LOD L O D L O D LOD L O D LODLODLODLODLODLODLODLODLODLODLODLODL O D LODPLOT DATE: 8/14/2019 6:28 PM BY: SKANEFile: O:\32453-ATL\32453-002\CAD_BIM\GENERAL\G001 Saved by SKANE Save date: 8/12/2019 1:51 PM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 AUGUST 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. CHECKED BY: DRAWN BY: DESIGNED BY: LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 LANDSCAPE ARCHITECT: SUPPORTING ENGINEER: SCALE: 1" = 200' PLAN 100 1" = 200' 200 0 200' ISLANDS AREALINVILLERIVER CLUBHOUSE ISLAND DRWEST CHANNELEAST CHANNELWOODCHUCK RDLOCH DORNIE HWY 105CLUBHOUSE DRGRASSY CREEK RDCLUBHOUSE DR BEACH AREA PARKING SPILLWAY BRIDGE AREA 2 AREA 3 AREA 1 AREA 4 AREA 6 AREA 5 AREA 7 LINVILLE RIVERJ-CLUSTER AREA 7 T. SCHUELER S. KANE J. MCSWAIN - - T. SCHUELER G001 DRAWING INDEX & KEY MAP DRAWING INDEX DRAWING NUMBER DRAWING TITLE DRAWING NUMBER DRAWING TITLE GENERAL AMENITIES G000 COVER L102 SITE PLAN AREA 2 G001 DRAWING INDEX & KEY MAP L105 SITE PLAN AREA 5 G002 GENERAL NOTES, LEGEND, & ABBREVIATIONS L106 SITE PLAN AREA 6 E&SC L106.1 SITE PLAN AREA 6 ENLARGEMENT E000 EROSION & SEDIMENT CONTROL NOTES L107 SITE PLAN AREA 7 E001 EROSION & SEDIMENT CONTROL PHASE 1 OF 2 L202 GRADING & STORMWATER PLAN AREA 2 E002 EROSION & SEDIMENT CONTROL PHASE 2 OF 2 L205 GRADING & STORMWATER PLAN AREA 5 E101 EROSION & SEDIMENT CONTROL PLAN AREA 1 L206 GRADING & STORMWATER PLAN AREA 6 E102 EROSION & SEDIMENT CONTROL PLAN AREA 2 L206.1 GRADING & STORMWATER PLAN AREA 6 ENLARGEMENT E103 EROSION & SEDIMENT CONTROL PLAN AREA 3 L207 GRADING & STORMWATER PLAN AREA 7 E104 EROSION & SEDIMENT CONTROL PLAN AREA 4 L302 LAYOUT PLAN AREA 2 E105 EROSION & SEDIMENT CONTROL PLAN AREA 5 L305 LAYOUT PLAN AREA 5 E106 EROSION & SEDIMENT CONTROL PLAN AREA 6 L306 LAYOUT PLAN AREA 6 E107 EROSION & SEDIMENT CONTROL PLAN AREA 7 L306.1 LAYOUT PLAN AREA 6 ENLARGEMENT E201 ENTRANCE & PERIMETER CONTROL DETAILS L307 LAYOUT PLAN AREA 7 E202 ACCESS & FLOW DIVERSTION DETAILS L402 PLANTING PLAN AREA 2 E203 FINAL STABILIZATION & SEDIMENT CONTROL L405 PLANTING PLAN AREA 5 CIVIL L406 PLANTING PLAN AREA 6 C100 EXISTING CONDITIONS & DEMO PLAN OVERALL L407 PLANTING PLAN AREA 7 C101 EXISTING CONDITIONS & DEMO AREA 1 L500 SITE DETAILS C102 EXISTING CONDITIONS & DEMO AREA 2 L501 SITE DETAILS C103 EXISTING CONDITIONS & DEMO AREA 3 L600 STORMWATER DETAILS C104 EXISTING CONDITIONS & DEMO AREA 4 L601 STORMWATER DETAILS C105 EXISTING CONDITIONS & DEMO AREA 5 L700 PLANTING DETAILS C106 EXISTING CONDITIONS & DEMO AREA 6 L701 PLANTING DETAILS C107 EXISTING CONDITIONS & DEMO AREA 7 BRIDGE C200 GRADING & DREDGING PLAN OVERALL B000 TYPICAL SECTION AND GENERAL NOTES C201 GRADING & DREDGING PLAN AREA 1 B001 APPROACH AND RAIL DETAILS C202 GRADING & DREDGING PLAN AREA 2 B101 BRIDGE 1 - GENERAL C203 GRADING & DREDGING PLAN AREA 3 B102 BRIDGE 1 - ABUTMENT 1 C204 GRADING & DREDGING PLAN AREA 4 B103 BRIDGE 1 - ABUTMENT 2 C205 GRADING & DREDGING PLAN AREA 5 B104 BRIDGE 1 - ABUTMENT DETAILS C206 GRADING & DREDGING PLAN AREA 6 B201 BRIDGE 2 - GENERAL C207 GRADING & DREDGING PLAN AREA 7 B202 BRIDGE 2 - ABUTMENT 1 C220 GRADING & DREDGING PROFILES OVERALL B203 BRIDGE 2 - ABUTMENT 2 C221 GRADING & DREDGING PROFILES B204 BRIDGE 2 - ABUTMENT DETAILS C222 GRADING & DREDGING PROFILES B301 BRIDGE 3 - GENERAL C223 GRADING & DREDGING PROFILES B302 BRIDGE 3 - ABUTMENT 1 C224 GRADING & DREDGING PROFILES B303 BRIDGE 3 - ABUTMENT 2 C225 GRADING & DREDGING PROFILES B304 BRIDGE 3 - ABUTMENT DETAILS C226 GRADING & DREDGING PROFILES B305 BRIDGE 3 - TYPICAL PIER C300 REVETMENT DETAILS B306 BRIDGE 3 - ALTERNATE PIER C301 STANDARD DETAILS B307 BRIDGE 3 - ALTERNATE CONCRETE PIER DETAILS C400 SANITARY SEWER PLAN, PROFILE, AND DETAIL B401 BRIDGE 4 - GENERAL B402 BRIDGE 4 - ABUTMENT 1 B403 BRIDGE 4 - ABUTMENT 2 B404 BRIDGE 4 - ABUTMENT DETAILS B501 BRIDGE 5 - GENERAL B502 BRIDGE 5 - ABUTMENT 1 B503 BRIDGE 5 - ABUTMENT 2 B504 BRIDGE 5 - ABUTMENT DETAILS WALL DESIGN W000 GENERAL NOTES AND ABBREVIATIONS W001 STATEMENT OF SPECIAL INSPECTIONS W100 TYPICAL WALL SECTIONS W101 FOUNDATION DETAILS GENERAL CONSTRUCTION NOTES: 1.ALL CONSTRUCTION WORK SHALL BE IN ACCORDANCE WITH THE CONTRACT DOCUMENTS (INCLUDING SEPARATE SPECIFICATIONS PACKAGE). 2.EXISTING UTILITIES AND NEW WORK UNDER THIS CONTRACT ARE DIFFERENTIATED BY A SYSTEM OF LABELING AND BY VARYING DRAFTING LINE WEIGHTS. 3.EXCEPT AS OTHERWISE NOTED, HEAVY WEIGHT/DARKER LINES ARE UTILIZED ON DRAWINGS TO DEPICT NEW WORK AND LIGHT WEIGHT LINES ARE UTILIZED TO DEPICT EXISTING CONDITIONS, FEATURES, AND UTILITIES. 4.THE LOCATION OF FEATURES SHOWN ON THESE DRAWINGS ARE PROVIDED ONLY FOR THE CONVENIENCE OF THE CONTRACTOR, AND GRANDFATHER GOLF & COUNTRY CLUB (GG&CC) DOES NOT WARRANT AND/OR GUARANTEE THE ACCURACY OR COMPLETENESS OF THIS INFORMATION. THE CONTRACTOR SHALL FIELD VERIFY TO THEIR SATISFACTION, THE WORK REQUIREMENTS ASSOCIATED UNDER THIS CONTRACT. 5.THE SOURCE OF THE 100-YEAR FLOODPLAIN AS SHOWN ON THE DRAWINGS FOR LINVILLE RIVER: FEMA FLOOD INSURANCE RATE MAP #3710185600J. 6. FOR INFORMATION RELATED TO PROJECT GEOTECHNICAL TESTING, SEE SEPARATE GEOTECH INFORMATION AS PART OF THE SPECIFICATIONS PACKAGE. 7.VEHICLE ACCESS MAY NOT BE AVAILABLE TO ALL AREAS IDENTIFIED IN THIS CONTRACT, AND FOOT ACCESS MAY BE REQUIRED TO COMPLETE THE WORK IN THESE AREAS. SURVEY DATA: 1.SITE INFORMATION HAS BEEN PROVIDED BY SITE SURVEY PREPARED BY MCGILL ASSOCIATES DATED MAY 10, 2019. 2.ALL VERTICAL ELEVATION DATA IS BASED ON THE FOLLOWING DATUM: NC83F. 3.ALL HORIZONTAL DATA IS BASED ON THE FOLLOWING DATUM: NC83F. 4.CONTRACTOR IS RESPONSIBLE FOR PROVIDING AND MAINTAINING STAKEOUT DURING CONSTRUCTION UNTIL FINAL ACCEPTANCE BY THE ENGINEER. STAGED ACCEPTANCE MAY BE PERMITTABLE SUBJECT TO PRIOR APPROVAL BY THE ENGINEER. 5.RIGHT-OF-WAY AND PROPERTY LINES SHOWN ON THE DRAWINGS SHALL BE CONSIDERED APPROXIMATE. CONTRACTOR SHALL CONFIRM LOCATIONS OF PROPERTY MARKERS, PROPERTY LINES, AND RIGHTS-OF-WAY PRIOR TO COMMENCING WORK. 6.THE CONTRACTOR SHALL MAKE EVERY EFFORT TO SAVE AND MAINTAIN ALL PROPERTY IRONS, MONUMENTS, OTHER PERMANENT POINTS AND LINES OF REFERENCE AND CONSTRUCTION STAKES. A NORTH CAROLINA REGISTERED LAND SURVEYOR, AT THE CONTRACTOR'S EXPENSE, SHALL REPLACE PROPERTY IRONS, MONUMENT, AND OTHER PERMANENT POINTS OF REFERENCE DESTROYED BY THE CONTRACTOR. FOR REFERENCE MONUMENT, SEE EXISTING CONDITIONS DRAWINGS. SITE AND PUBLIC SAFETY: 1.CONTRACTOR IS RESPONSIBLE FOR CREATING AND MAINTAINING A SAFE AND APPROPRIATE TRAFFIC SAFETY PLAN AND IS RESPONSIBLE FOR MAINTAINING A SAFE WORK SITE INCLUDING ADHERENCE TO LOCAL STATE AND FEDERAL REQUIREMENTS INCLUDING OSHA. 2.CONTRACTOR IS RESPONSIBLE FOR THE SAFE MAINTENANCE OF TRAFFIC DURING CONSTRUCTION. 3.DURING EXCAVATION AND PLACEMENT OF UTILITIES THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE SAFETY REGULATIONS. SHEET PILING, SHORING, AND/OR BRACING DESIGNS SHALL BE PREPARED BY A REGISTERED PROFESSIONAL ENGINEER IN THE STATE OF NORTH CAROLINA, AS MAY BE NECESSARY TO COMPLY WITH THESE REGULATIONS. PRODUCT SUBMITTALS, SPECIFICATIONS AND VERIFICATIONS: 1.CONTRACTOR SHALL PROVIDE ALL MATERIALS AND MATERIAL CERTIFICATIONS FOR THIS PROJECT TO THE ENGINEER IN ACCORDANCE WITH THESE APPROVED CONSTRUCTION DOCUMENTS AND ANY ASSOCIATED SPECIFICATIONS OR PROJECT MANUALS. 2.SPECIFIED AND/OR PROPRIETARY PRODUCTS SHOWN HEREON MAY BE SUBJECT TO SUBSTITUTION WITH OTHER PRODUCTS OF EQUAL OR SUPERIOR QUALITY AS RECOMMENDED BY THE CONTRACTOR SUBJECT TO THE WRITTEN PREVIEW AND APPROVAL OF THE DESIGN ENGINEER. WHEN THE CONTRACTOR USES PROPRIETARY PRODUCTS, IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY WITH THE SUPPLIER/MANUFACTURER THAT IT WILL FUNCTION PER THE DESIGN OR THE GIVEN FIELD CONDITIONS. THE DESIGN ENGINEER SHALL BE NOTIFIED IMMEDIATELY IF ANY DEVIATIONS FROM EXISTING FIELD CONDITIONS EXIST WHICH MAY AFFECT PRODUCT FUNCTION. 3.THESE PLANS WERE PREPARED WITH SURVEYED FIELD INFORMATION AND/OR GIS DATA AVAILABLE AT THE TIME PROJECT DESIGN. IT IS POSSIBLE THAT FIELD CONDITIONS AT THE TIME OF CONSTRUCTION MAY VARY FROM THESE PLANS AND IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY FIELD CONDITIONS SUCH AS ELEVATIONS AND DEPTHS PRIOR TO PROCEEDING WITH WORK. 4.ANY CUT AND FILL QUANTITIES AS LISTED HERE ON SHALL BE CONSIDERED APPROXIMATE ONLY AND ARE SUBJECT TO CHANGE DEPENDING ON ACTUAL SITE CONDITIONS AND CONSTRUCTION OPERATIONS. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING QUANTITIES THROUGH A FIELD VISIT AND HIS/HER OWN QUANTITY TAKE-OFFS. ALL QUANTITIES AND TAKE OFFS SHOWN HEREON ARE ESTIMATED ONLY AND THE CONTRACTOR VERIFICATION IS REQUIRED. NOTICE TO PROCEED AND PRE-CONSTRUCTION REQUIREMENTS: 1.APPROVAL OF THIS PLAN SHALL NOT CONSTITUTE AUTHORIZATION TO BEGIN CONSTRUCTION. ALL APPLICABLE PERMITS MUST BE OBTAINED PRIOR TO CONSTRUCTION. CONTRACTOR SHALL OBTAIN ALL THE NECESSARY PERMITS, IF NOT ALREADY OBTAINED BY THE ENGINEER, FROM THE APPROPRIATE AUTHORITIES, DEPARTMENTS, AND/OR AGENCIES HAVING JURISDICTION PRIOR TO COMMENCING WORK. 2.THE CONTRACTOR SHALL PROVIDE ALL MATERIALS AND MATERIAL CERTIFICATIONS FOR THE PROJECT WORK TO THE ENGINEER FOR COMPARISON AGAINST THE CONSTRUCTION DOCUMENTS AND APPROVAL OF SAID MATERIALS PRIOR TO PURCHASE, RENTING, SHIPPING OR ONSITE STORAGE. THE CONTRACTOR WILL BEAR THE COST OF REMOVAL, RE-STOCKING ETC. FOR THE PURCHASE, STAGING OR PLACEMENT OF UNAPPROVED MATERIALS. 3.THE CONTRACTOR SHALL CONFIRM WITH THE ENGINEER THAT THE IMPACTED PROPERTIES ARE NOTIFIED IN WRITING AT LEAST TWO (2) WEEKS PRIOR TO STARTING WORK SHOWN ON PLANS. 4.THE CONTRACTOR SHALL CALL 811 OR 1-800-632-4949 AT LEAST 72-HOURS PRIOR TO START OF EXCAVATION TO DETERMINE THE LOCATION OF EXISTING UTILITIES. ANY UTILITY, WHETHER SHOWN OR NOT, THAT IS DAMAGED BY THE CONTRACTOR SHALL BE REPAIRED IMMEDIATELY AT NO EXPENSE TO GG&CC. SHOULD THE CONTRACTOR DISCOVER DISCREPANCIES BETWEEN THE CONTRACT DRAWINGS AND FIELD CONDITIONS, THE ENGINEER IS TO BE NOTIFIED IMMEDIATELY. SHOULD THE CONTRACTOR MAKE FIELD CORRECTIONS OR ADJUSTMENTS WITHOUT THE AUTHORIZATION OF THE ENGINEER, THE CONTRACTOR ASSUMES THE RESPONSIBILITY FOR SAID CORRECTIONS OR ADJUSTMENTS. 5.PRE-CONSTRUCTION FIELD WALK: THE PROJECT LIMITS OF DISTURBANCE (LOD) MUST BE STAKED OUT AND REVIEWED BY THE ENGINEER(S), INCLUDING LOCAL UTILITY VENDORS, DEPARTMENTS OF TRANSPORTATION, AGENCY PERMIT ISSUERS, ETC. SEE “SEQUENCE OF CONSTRUCTION” FOR A LIST OF REQUIRED PARTIES FOR FIELD VERIFICATION AND APPROVAL OF LOD. UTILITIES: 1.UTILITIES HAVE BEEN PLOTTED FROM AVAILABLE SURVEY INFORMATION. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THEIR COMPLETENESS AND EXACT LOCATION AND TO AVOID DAMAGE TO THEM. THE CONTRACTOR SHALL CONTACT NORTH CAROLINA 811 AT PHONE NUMBER 811 OR 1-800-632-4949, OR BY REMOTE TICKET ENTRY, TO REQUEST UNDERGROUND UTILITY LOCATION MARK-OUT AT LEAST THREE (3) WORKING DAYS BUT NO MORE THAN TWELVE (12) WORKING DAYS PRIOR TO BEGINNING EXCAVATION. THE CONTRACTOR SHALL ASLO CONTACT AND REQUEST UTILITY LOCATION MARK-OUT FROM BURIED UTILITY OWNERS WITH UTILITIES IN THE PROJECT SITE THAT ARE NOT PARTICIPANTS OF NORTH CAROLINA 811. 2.THE CONTRACTOR SHALL FIELD-VERIFY ALL EXISTING UTILITIES, INCLUDING DIMENSIONS, FEATURES AND/OR STRUCTURES RELATED TO PROJECT CONSTRUCTION PRIOR TO ORDERING MATERIALS OR COMMENCING WORK. UNLESS OTHERWISE INDICATED IN THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL MAINTAIN UNINTERRUPTED UTILITY SERVICE. ANY DAMAGE INCURRED SHALL BE IMMEDIATELY REPAIRED TO THE SATISFACTION OF THE ENGINEER AT THE CONTRACTORS EXPENSE THE CONTRACTOR SHALL BE AWARE THAT COMMUNICATION AND OTHER UTILITIES MAY NOT BE SHOWN ON THE PLANS. 3.GRADING AROUND UTILITIES MAY BE REQUIRED. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO PROTECT AND SUPPORT EXISTING UTILITIES AND SHALL MAINTAIN UNINTERRUPTED SUPPLY OR SERVICE OF THESE UTILITIES. ANY DAMAGE INCURRED SHALL BE REPAIRED IMMEDIATELY AT THE CONTRACTORS EXPENSE. IT WILL BE THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE WITH AND PAY THE UTILITY FOR SUPPORT OR RELOCATION OF UTILITY POLES. 4.UNLESS OTHERWISE INDICATED, THE CONTRACTOR SHALL CLEAR ALL UTILITIES BY A MINIMUM OF 1'-0" VERTICALLY AND 5'-0" HORIZONTALLY. 7.THE CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO EXISTING ROADS, DRIVEWAYS, CULVERTS, DITCHES, DRAIN FIELDS, UTILITIES, PIPING STRUCTURES AND EQUIPMENT WHICH OCCURS AS A RESULT OF PROJECT CONSTRUCTION, AND SHALL REPAIR TO ORIGINAL CONDITION OR REPLACE IN KIND ANY DAMAGED ITEMS. 8.DISTURBED CURBS, GUTTERS, PATHS AND SIDEWALKS SHALL BE REPLACED IN-KIND TO THE NEAREST EXISTING JOINTS. 9.STREET LIGHTING AND CABLING SHOWN ON THESE SHEETS ARE COMPILED FROM BEST AVAILABLE INFORMATION FOR THE CONVENIENCE OF THE CONTRACTOR. THE CONTRACTOR SHALL VERIFY LOCATIONS OF ALL STREET LIGHTING PRIOR TO BEGINNING WORK. THE CONTRACTOR SHALL EXERCISE EXTREME CAUTION WHEN WORKING NEAR OVERHEAD OR UNDERGROUND ELECTRIC CABLING. SITE ACCESS, STAGING, STOCKPILING AND HOUSEKEEPING: 1.ACCESS SHALL ONLY OCCUR PER APPROVED LOCATIONS AS PER THE CONSTRUCTION DOCUMENTS UNLESS ALTERNATIVE ACCESS LOCATIONS ARE APPROVED, IN WRITING, BY GG&CC OR THE DESIGN ENGINEER. 2.IF THE CONSTRUCTION DOCUMENTS REFER TO SPECIFIC CONSTRUCTION STAGING OR SEQUENCING, THESE STAGES OR SEQUENCES MUST BE ADHERED TO UNLESS AN ALTERNATIVE APPROACH IS AGREED ON AND APPROVED BY THE ENGINEER, IN WRITING, PRIOR TO USE OF ALTERNATIVE ACCESS POINT. 3.AREAS WHERE PUMP-AROUND IS REMOVED OR DE-ACTIVATED AT THE END OF THE WORKDAY, MUST BE COMPLETED AND STABILIZED DAILY. DISTURBED AREAS ABOVE THE WATERLINE SHALL RECEIVE STRAW/MULCH/MATTING AT THE END OF EACH WORKDAY. ONCE FLOW IS RE-ESTABLISHED AT THE END OF THE WORKDAY, THE CONTRACTOR SHALL ALLOW SUFFICIENT TIME TO INSPECT THE NEW FLOW PATTERN AND MAKE ADJUSTMENTS AS NECESSARY TO ENSURE NON-EROSIVE CONDITIONS BEFORE VACATING THE SITE. 4.THE CONTRACTOR SHALL SECURE THE SITE AND PERFORM ANY NECESSARY CLEANUP OR HOUSEKEEPING AT THE END OF THE WORK DAY TO MINIMIZE INCONVENIENCE TO IMPACTED RESIDENCES CLUB MEMBERS. UNLESS OTHERWISE COMMUNICATED TO, AND AGREED BY GG&CC: REMOVE ON A DAILY BASIS ALL EXCESS CONSTRUCTION DEBRIS AND MATERIAL FROM THE WORK SITE. 5.THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING SILT AND DEBRIS OUT OF THE STORM DRAINAGE SYSTEM, STREAMS, RIVERS, ETC. FOR THE DURATION OF THE CONTRACT. 6.IT IS THE CONTRACTORS RESPONSIBILITY TO CLEAN STREETS AND PARKING AREAS OF DEBRIS AND/OR DUST AND TAKE WHATEVER MEASURES ARE NECESSARY TO ENSURE THAT ALL ROADS ARE MAINTAINED IN A MUD AND DUST FREE CONDITION AT ALL TIMES. 7.THE CONTRACTOR SHALL BE RESPONSIBLE FOR AVOIDING THE SPILLAGE OF RAW SEWAGE OR OTHER SUBSTANCES WHICH WOULD BE CONSIDERED DANGEROUS TO THE ENVIRONMENT DURING THEIR CONSTRUCTION OPERATIONS. THE CONTRACTOR SHALL FURNISH ALL NECESSARY EQUIPMENT (PLUGGING, PUMPING, CONTAINMENT EQUIPMENT, ETC) TO PREVENT SAID SPILLAGE. 8.WHENEVER POSSIBLE, THE CONTRACTOR SHALL COMPLETE THE CONSTRUCTION WORK UNDER DRY WEATHER CONDITIONS. 9.THE CONTRACTOR SHALL PROVIDE GROUND PROTECTION FOR EXISTING ACCESS ROADS (DIRT, GRAVEL, MULCH AND/OR MATTING AS INDICATED ON THE CONSTRUCTION DOCUMENTS) TO BE UTILIZED FOR CONSTRUCTION ACCESS AND RESTORE ACCESS ROADS TO A PRE-CONSTRUCTION CONDITION. THE CONTRACTOR SHOULD DOCUMENT THE CONDITION OF THE EXISTING ACCESS ROAD PRIOR TO THE START OF WORK. 10.STOCKPILING AND LAYDOWN AREAS: ANY STOCKPILE OR LAYDOWN AREAS SHOWN ON THE CONSTRUCTION DOCUMENTS ARE ILLUSTRATED FOR THE CONTRACTOR'S CONSIDERATION. THE CONTRACTOR CAN LOCATE STOCKPILING, LAYDOWN AND EQUIPMENT STORAGE AREAS WITHIN THE LIMITS OF DISTURBANCE BASED ON GOOD JUDGMENT, ADHERENCE TO PERMIT REQUIREMENTS, SCHEDULE REQUIREMENTS AND PROJECT GOALS. AREAS MAY BE STAGED AND MOVED AS THE CONTRACTOR SEES FIT. 11.UNLESS OTHERWISE INDICATED ON THE CONSTRUCTION DOCUMENTS, THE CONTRACTOR SHALL NOT STAGE OR STORE WITHIN A PUBLIC RIGHT-OF-WAY. SIMILARLY, THE CONTRACTOR SHALL NOT STAGE OR STORE MATERIALS ON PRIVATELY HELD PROPERTY OTHER THAN GG&CC. 12.BEYOND WHAT IS SHOWN ON THESE CONSTRUCTION DOCUMENTS THE CONTRACTOR IS RESPONSIBLE FOR SECURING STORAGE AND STAGING AREAS AT HIS OWN EXPENSE. THERE SHALL BE NO PAYMENT FOR STORED MATERIALS. PAYMENT SHALL BE ONLY AFTER INSTALLATION OF MATERIALS AND SUCCESSFUL TESTING AS APPROVED BY THE ENGINEER. WATER HANDLING AND SEDIMENT CONTROL: 1.CONTRACTOR IS RESPONSIBLE FOR CONTROL OF WATER THROUGHOUT THE PROJECT SITE, INCLUDING RUNOFF THROUGH DISTURBED AREAS. CONTRACTOR SHALL BE FAMILIAR WITH STATE AND LOCAL STANDARDS, SPECIFICATIONS AND REQUIREMENTS FOR SEDIMENT AND EROSION CONTROL. 2.DRY WEATHER STREAM BASE FLOW IS A FUNCTION OF WEATHER PATTERNS, TIME OF YEAR, GROUNDWATER, SNOW MELT, UPSTREAM MAN-INDUCED RELEASES AND OTHER NON-CALCULATED FACTORS AND THEREFORE WAS NOT ESTIMATED FOR THIS PROJECT. IT IS THE CONTRACTOR'S RESPONSIBILITY TO CARRY OUT SITE RECONNAISSANCE TO DETERMINE PUMP-AROUND NEEDS SUCH AS THE NUMBER AND SIZE OF PUMPS HE/SHE WILL NEED TO SUCCESSFULLY COMPLETE THE PROJECT. 3.GROUNDWATER FROM ALL DEWATERING OPERATIONS SHALL BE DISCHARGED TO AN ENVIRONMENTALLY ACCEPTABLE LOCATION IN ACCORDANCE WITH THE CONTRACT DOCUMENTS, AND ALL APPLICABLE LOCAL, STATE AND FEDERAL REQUIREMENTS. TREE, WETLAND AND OTHER NATURAL RESOURCE PROTECTION: 1.REFER TO EROSION AND SEDIMENT CONTROL SHEETS FOR APPROVED TREE REMOVALS; PRESERVE ALL TREES UNLESS OTHERWISE NOTED. 2.CONTRACTOR IS RESPONSIBLE FOR COORDINATING ALL TREE PROTECTION MEASURES AND TREE REMOVALS PER THE CONSTRUCTION DOCUMENTS AND ANY ASSOCIATED SPECIFICATIONS AND/OR PROJECT MANUALS. THESE MEASURES (WHICH MAY INCLUDE HARDWOOD MATS, TREE PLANKING, ROOT AERATION MATTING, EQUIPMENT RESTRICTIONS, MULCH ACCESS ROUTES, ROOT PRUNING, TEMPORARY TREE PROTECTION FENCING, SIGNAGE, ETC.) MUST BE INSTALLED AND APPROVED BY THE ENGINEER BEFORE HEAVY EQUIPMENT WILL BE ALLOWED TO ACCESS THE PROJECT SITE AND/OR TRAVERSE OVER EXISTING ROOT SYSTEMS. 3.THE CONTRACTOR SHALL PROVIDE APPROPRIATE TREE PRUNING IN ACCORDANCE WITH THE CONTRACT DOCUMENTS WHEN THE CONTRACTORS CONSTRUCTION ACTIVITIES ARE IN THE VICINITY OF STAND ALONE TREES OR FORESTED AREAS. ALL BRANCH AND ROOT PRUNING ACTIVITIES SHALL BE COMPLETED UNDER THE SUPERVISION OF A NORTH CAROLINA-LICENSED TREE EXPERT WHOSE CREDENTIALS HAVE BEEN APPROVED BY THE ENGINEER. GG&CC ASSETS: 1.CONTRACTOR IS TO COORDINATE ANY TEMPORARY OR PERMANENT GUARD RAIL/BOLLARD/GATE REMOVAL AND REPLACEMENT WITH GG&CC. ALL REMOVAL AND REPLACEMENT SHALL BE IN ACCORDANCE WITH THE CONTRACT DOCUMENTS OR AS DIRECTED BY GG&CC. TEMPORARILY REMOVE AND STORE GUARD RAIL/BOLLARD/GATE MATERIALS FOR REINSTALLATION AT CONCLUSION OF CONSTRUCTION. 2.ALL GG&CC FACILITIES, SUCH AS GOLF COURSE AREAS, COURSE EQUIPMENT, PATHWAYS, ETC., LOCATED OUTSIDE THE LOD, SHALL NOT BE DISTURBED. IF COUNTRY CLUB FACILITIES LOCATED OUTSIDE LOD'S ARE DAMAGED, REPAIRS SHALL BE MADE BY THE CONTRACTOR AT THE CONTRACTOR'S EXPENSE. 3.FOR ASPHALT PATH REPAIR/REPLACEMENT, SAWCUT ASPHALT/CURB & GUTTER/SIDEWALK PERPENDICULAR TO SURFACE. FACE OF CUTS SHALL BE NEAT, CLEAN, AND STRAIGHT. REMOVE CURB AND GUTTER AND SIDEWALKS TO NEAREST JOINT, OR TO EXTENTS SHOWN. ABBREVIATIONS CL CENTERLINE CPP CORRUGATED PLASTIC PIPE DI DRAINAGE INLET DIP DUCTILE IRON PIPE ESC EROSION & SEDIMENT CONTROL EX EXISTING FB FILTER BAG GG & CC GRANDFATHER GOLF & COUNTRY CLUB GCS GRADE CONTROL SILL INV INVERT IRW IMBRICATED ROCK WALL LOD LIMIT OF DISTURBANCE MH MANHOLE OHE OVERHEAD ELECTRIC P PUMP PC POINT OF CURVE PCC POINT OF COMPOUND CURVE PROP PROPOSED PSF PEDESTRIAN SAFETY FENCE RCP REINFORCED CONCRETE PIPE ROP ROCK OUTLET PROTECTION SAN SANITARY SBM STREAM BED MATERIAL SCE STABILIZED CONSTRUCTION ENTRANCE SDMH STORM MANHOLE SF SILT FENCE SS SANITARY SEWER SSMH SANITARY SEWER MANHOLE TPA TEMPORARY PUMP AROUND TPF TREE PROTECTION FENCE TRM TURF REINFORCEMENT MAT W WATER WSE WATER SURFACE ELEVATION YR YEAR OPEN WATER A SECTION SYMBOLOGY LEGEND DEMOLISH PROPOSED SANITARY/STORM MANHOLE CONTOUR MAJOR CONTOUR MINOR 250 EXISTING CURB, EDGE OF PAVING SANITARY MANHOLE SANITARY SEWER STORM PIPE STORM MANHOLE PROPERTY LINE / RIGHT-OF-WAY BUILDING/STRUCTURE OVERHEAD ELECTRIC 100-YR WSE OPEN WATER EDGE OF WATER EDGE OF WATER STABILIZED CONSTRUCTION ENTRANCE STREAM CL WATER LINEW EXISTING GRADE LIMITS OF DISTURBANCE SANITARY/STORM PIPE PROPOSED GRADE PROFILE/SECTIONS APPROVED DRY FILL EROSION AND SEDIMENT CONTROL P ROP ROCK OUTLET PROTECTION TEMPORARY BARRIER DIVERSION PUMP CONTRACTOR STAGING AREA SILT FENCESF LIGHT POLE GRAVITY DIVERSION PIPE BOLLARD CONTOUR MAJOR CONTOUR MINOR 100 LANDSCAPE BOULDER IMBRICATED ROCK WALL PIPES/STRUCTURES/BRIDGE TO BE REMOVED TREELINE UNDERCUT X FENCE CONCRETE STRUCTURE/SIDEWALK STACKED ROCK WALL EXISTING PIPES 100-YR WSE TREE PROTECTION FENCETPFPEDESTRIAN SAFETY FENCEPSF PLOT DATE: 8/14/2019 6:28 PM BY: SKANEFile: O:\32453-ATL\32453-002\CAD_BIM\GENERAL\G002 Saved by JMCSWAIN Save date: 7/7/2019 3:45 PM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 AUGUST 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. CHECKED BY: DRAWN BY: DESIGNED BY: LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 LANDSCAPE ARCHITECT: SUPPORTING ENGINEER: SIPHON / DEWATERING SYSTEM TIMBER MAT / CONSTRUCTION MAT DREDGE / EXCAVATE 3D GEOMAT / ENKAMAT TREE T. SCHUELER S. KANE J. MCSWAIN - - T. SCHUELER G002 GENERAL NOTES, LEGEND, & ABBREVIATIONS ALIGNMENT CENTERLINE 0+00 LIMITS OF DISTURBANCE MISC DRAINAGE PIPE POST WATER METER X FENCE WET FILL ISLAND PERIMETER BERM 3" - 4" DRAINAGE STONE IMBRICATED ROCK COIR MAT FLOCCULANT TREATMENT LOG / BLOCK TURBIDITY CURTAINTC PLOT DATE: 8/14/2019 6:28 PM BY: SKANEFile: O:\32453-ATL\32453-002\CAD_BIM\ESC\E000 Saved by JMCSWAIN Save date: 7/8/2019 9:13 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 AUGUST 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. CHECKED BY: DRAWN BY: DESIGNED BY: LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 LANDSCAPE ARCHITECT: SUPPORTING ENGINEER: EROSION & SEDIMENT CONTROL NOTES: 1.THE CONTRACTOR WILL COMPLY WITH ALL REQUIREMENTS OF SEDIMENT AND EROSION CONTROL AS SET FORTH BY THE NORTH CAROLINA EROSION AND SEDIMENT CONTROL MANUAL. THE CONTRACTOR WILL BE REQUIRED TO MAINTAIN, MONITOR AND REPORT ON ALL EROSION AND SEDIMENT CONTROL ITEMS RELATED TO THE PERMIT FOR CONSTRUCTION ACTIVITY. 2.CONTRACTOR SHALL INSTALL ALL TEMPORARY EROSION CONTROL MEASURES WITHIN THE PROJECT AREA PRIOR TO BEGINNING ANY EARTHWORK. 3.CONTACT AND NOTIFY: GG&CC, PROJECT ENGINEER, AND NCDEQ LAND QUALTIY AT LEAST 72 HOURS PRIOR TO START OF CONSTRUCTION STATING: A.A REQUEST FOR A PRE-CONSTRUCTION MEETING B.WHEN CONTRACTOR INTENDS TO BEGIN CONSTRUCTION C.WHEN CONTRACTOR INTENDS TO INSTALL STORMWATER MANAGEMENT FACILITIES D.SOURCE OF BORROW MATERIAL E.LOCATION OF DISPOSAL AREA WITH AN ACTIVE PERMIT F.CONTRACTOR'S TENTATIVE CLOSING DATE INITIAL DISTURBANCE WILL BE LIMITED TO THAT NECESSARY TO GAIN ENTRANCE TO THE SITE AND INSTALL NECESSARY SEDIMENT CONTROLS AS PER THE APPROVED PLANS. 4.ALL SEDIMENT CONTROLS AND CRITICAL SLOPES MUST BE STABILIZED WITHIN THREE (3) CALENDAR DAYS. ALL OTHER INACTIVE DISTURBED AREAS ON THE PROJECT SITE MUST BE STABILIZED WITHIN SEVEN (7) CALENDAR DAYS. 5.ALL EXCAVATED MATERIAL SHALL BE PLACED ON THE HIGH SIDE WHENEVER POSSIBLE AND CONFINED TO AN AREA WHERE IT WILL NOT OBSTRUCT THE NORMAL COURSE OF DRAINAGE. 6.PUMPING OF SEDIMENT LADEN WATER WILL NOT BE ALLOWED UNLESS IT IS FILTERED BY WAY OF AN APPROVED SEDIMENT TRAPPING DEVICE. 7.WATER REMOVED VIA SUMP PIT OR REMOVABLE PUMPING STATION SHALL BE PUMPED THROUGH AN APPROVED DEWATERING BASIN OR FILTER BAG PRIOR TO DISCHARGE VIA A STABLE OUTLET. 8.CONTINUOUS INSPECTION AND MAINTENANCE OF ALL SEDIMENT CONTROL DEVICES IS MANDATORY. 9.ANY SEDIMENT CONTROL DEVICES DISTURBED DURING CONSTRUCTION MUST BE RESTORED IMMEDIATELY. 10.ALL POINTS OF INGRESS AND EGRESS SHALL BE PROTECTED TO MINIMIZE TRACKING OF MUD ON TO PUBLIC RIGHT-OF-WAYS. 11.ANY EARTH, GRAVEL, AND/OR OTHER MATERIAL TRACKED, SPILLED OR WASHED ON TO ADJACENT ROADS MUST BE IMMEDIATELY REMOVED AND DISPOSED OF IN A PROPER MANNER. NO FLUSHING WILL BE PERMITTED. ALL MATERIAL MUST BE REMOVED BY MEANS OF SHOVELING AND SWEEPING. 12.THE CONTRACTOR SHALL NOT EXPOSE EARTH THAT CAN NOT BE TEMPORARILY OR PERMANENTLY STABILIZED WITHIN 24 HOURS. ANY EXCAVATED AREAS WHICH CAN NOT BE IMMEDIATELY STABILIZED, MUST BE TEMPORARILY STABILIZED WITH AT LEAST 4" OF MULCH OR GRADED AGGREGATE. 13.PROJECT ENGINEER MUST BE NOTIFIED IN WRITING OF WHERE ANY EXCESS MATERIAL WILL BE DISPOSED OR WHERE ANY BORROWED MATERIALS WILL COME FROM. 14.THE CONTRACTOR SHALL HAVE A NCDEQ LAND QUALITY EROSION CONTROL INSPECTOR INSPECT AND APPROVE THE WORK COMPLETED AT THE STAGES OF CONSTRUCTION SPECIFIED BELOW: A. UPON COMPLETION OF THE INSTALLATION OF THE PERIMETER SEDIMENT CONTROLS B. DURING ALL GRADING AND BUILDING OPERATIONS C. UPON FINAL STABILIZATION OF THE ENTIRE SITE PRIOR TO REMOVAL OF THE SEDIMENT CONTROLS 15.THE CONTRACTOR SHALL NOT DEVIATE FROM THE APPROVED SEDIMENT AND EROSION CONTROL PLAN WITHOUT FIRST RECEIVING APPROVAL FROM STORMWATER DEPARTMENT. VARIATIONS TO THE ORIGINAL PLAN MUST BE SUBMITTED IN WRITING WITH ALL PROPOSED MODIFICATIONS STILL BEING HIGHLIGHTED. SUBSTANTIAL CHANGES WILL NECESSITATE AMENDMENT OF THE GRADING / BUILDING PERMIT. 16.ALL ORANGE SAFETY FENCE, TREE PROTECTION MEASURES AND SILT FENCE DIVERSIONS MUST BE INSTALLED ACCORDING TO THE PLANS AND APPROVED BY THE ENGINEER BEFORE ANY CONSTRUCTION ACTIVITIES BEGIN. 17.NO CLEARING, GRADING, CONSTRUCTION OR OTHER DISTURBANCE OF VEGETATION IS PERMITTED OUTSIDE OF THE LIMITS OF DISTURBANCE, WITHOUT PRIOR APPROVAL OF THE SEDIMENT CONTROL INSPECTOR. 18.ALL TREES DESIGNATED FOR REMOVAL SHALL BE REMOVED IN STAGES AS SPECIFIED IN THE SEQUENCE OF CONSTRUCTION. AREAS OF TREE REMOVAL WITHIN THE LIMITS OF DISTURBANCE MUST BE TEMPORARILY STABILIZED USING SEED & WOOD CHIPS BY THE END OF EACH DAY. 19.THE CONTRACTOR MAY ONLY CLEAR & GRUB AREAS WITHIN THE DAILY CONSTRUCTION ZONE AS NECESSARY TO COMPLETE STREAM STABILIZATION EFFORTS. UNDER NO CIRCUMSTANCES WILL THE CONTRACTOR BE PERMITTED TO CLEAR & GRUB AREAS BEYOND THE CONFINES OF THE DAILY STREAM DIVERSION MEASURES. THE CONTRACTOR SHALL MAKE EVERY ATTEMPT TO MINIMIZE IMPACTS TO ALL TREES LOCATED WITHIN THE LIMITS OF DISTURBANCE. 20.STABILIZED CONSTRUCTION ENTRANCES AND TEMPORARY STOCKPILE AREAS SHALL BE CONFINED TO THE LOCATIONS GIVEN ON THE PLANS AND PROTECTED WITH PERIMETER EROSION CONTROL MEASURES AT ALL TIMES UNLESS DIRECTED OTHERWISE BY ENGINEER. 21.IF THE NEED FOR ADDITIONAL TEMPORARY STOCKPILES BECOMES NECESSARY, IT MUST: A.BE WITHIN THE LIMITS OF DISTURBANCE OR APPROVED OFF-SITE LOCATION. B.DRAIN TO A FUNCTIONING SEDIMENT CONTROL DEVICE. C.NOT IMPEDE UPON OR ALTER THE FUNCTION OF THE EXISTING SEDIMENT CONTROL MEASURES. D.NOT ALTER ANY NATURAL DRAINAGE PATTERNS, INCLUDING THE EXISTING AND PROPOSED STREAM CORRIDOR. E.BE APPROVED BY THE SEDIMENT CONTROL INSPECTOR. F.NOT BE WITHIN THE 100-YEAR FLOODPLAIN. IN-STREAM CONSTRUCTION NOTES: 22.LINVILLE RIVER AND ITS ASSOCIATED TRIBUTARIES IN THIS AREA ARE DESIGNATED AS CLASS C;Tr. THESE WATERS ARE PROTECTED FOR USES SUCH AS SECONDARY RECREATION, FISHING, WILDLIFE, FISH CONSUMPTION, AQUATIC LIFE INCLUDING PROPAGATION, SURVIVAL AND MAINTENANCE OF BIOLOGICAL INTEGRITY. ADDITIONAL RESTRICTIONS ARE IN PLACE AS A RESULT OF THE THE TROUT WATERS (Tr) CLASSIFICATION WHICH INCLUDES A 25-FOOT LAND DISTURBANCE BUFFER. NO LAND DISTURBING ACTIVITY MAY TAKE PLACE WITHIN THE TROUT BUFFER ZONE FROM OCTOBER 15 TO APRIL 15 UNLESS AUTHORIZED BY NC WRC AND DLR. 23.STREAM DIVERSION PRACTICES ARE TO MAINTAIN POSITIVE FLOW AROUND THE CONSTRUCTION ZONE AT ALL TIMES. THE CONTRACTOR MUST TIE THE DAILY STREAM CONSTRUCTION ZONE BACK INTO THE EXISTING CHANNEL BY THE END OF EACH WORK DAY. 24.WORK SHALL BE CONDUCTED IN A MANNER WHICH PERMITS THE PROPOSED BANKFULL CHANNEL CONSTRUCTION AND THE ADJACENT SECTION OF THE BANKFULL BENCH TO BE PERMANENTLY STABILIZED AT THE END OF EACH WORK DAY. PERMANENT STABILIZATION OF STREAMBED, BANKS AND FLOODPLAIN SOIL AREAS DURING CONSTRUCTION WILL CONSIST OF PLACED SUBSTRATE MATERIAL, FLOODPLAIN SOIL, BOULDER PROTECTION, TOPSOIL, STREAMBANK SEEDING AND COIR FIBER MATTING. STABILIZE ALL OTHER AREAS USING TEMPORARY SEED AND WOOD CHIPS WITHIN THE CONSTRUCTION ZONE. REMOVE ALL STREAM DIVERSION DEVICES BY THE END OF EACH WORK DAY. IN THE EVENT THAT THE CONTRACTOR CAN NOT COMPLY WITH THE ABOVE, THE STREAM DIVERSION DEVICE MUST BE CONTINUOUSLY MANNED AND OPERATING UNTIL THE CONSTRUCTION EFFORT CAN TIE BACK INTO THE EXISTING CHANNEL IN A STABLE MANNER. 25.STREAM DIVERSION MEASURES INCLUDING SANDBAGS, FILTER BAGS, AND PUMP-AROUND DEVICES, ETC. ARE INTENDED TO BE PROPERLY MAINTAINED AND REUSED AS WORK PROGRESSES DOWNSTREAM (OR UPSTREAM IF REQUIRED BY SITE CONDITIONS). 26.THE LENGTH AND LOCATION OF DAILY CONSTRUCTION ZONES SHOWN ON THE PLANS ARE THE APPROVED POSITIONS. ACTUAL LENGTH AND PLACEMENT OF SANDBAG DIKES MAY BE SLIGHTLY ADJUSTED TO FIT THE LOCAL TOPOGRAPHY AND THE AMOUNT OF DAILY IN-STREAM CONSTRUCTION THAT IS FEASIBLE TO THE CONTRACTOR. EACH DAILY WORK ZONE ISOLATED BY THE STREAM DIVERSION MEASURES SHALL NOT EXCEED 400 FEET IN STREAM CHANNEL LENGTH. 27.IN-STREAM CONSTRUCTION SHALL BE CONDUCTED WORKING IN AN UPSTREAM TO DOWNSTREAM MANNER. THE CONTRACTOR MAY WORK FROM DOWNSTREAM TO UPSTREAM WITH THE APPROVAL OF THE INSPECTOR. UNDER NO CIRCUMSTANCES WILL HEAVY EQUIPMENT BE PERMITTED TO CROSS THE NEWLY CONSTRUCTED STREAM CORRIDOR OR ROCK STRUCTURES. 28.NO CONSTRUCTION ACTIVITIES SHALL BE CONDUCTED DURING STORM EVENTS SENSITIVE AREA NOTES: 29.NO CONSTRUCTION ACTIVITIES SHALL BE UNDERTAKEN WITHIN SPECIFIED SENSITIVE AREAS OF THE PROJECT WITHOUT PRIOR NOTIFICATION OF THE ENGINEER. ALL WORK IN THESE AREAS SHALL BE MONITORED BY A RESPONSIBLE PARTY DESIGNATED BY THE CONTRACTOR TO ASSURE THAT REASONABLE CARE IS TAKEN IN OR ADJACENT TO THESE AREAS. AREAS CONSIDERED SENSITIVE ARE DEFINED AS: FLOODPLAINS, WETLANDS (TIDAL, NONTIDAL AND ASSOCIATED BUFFERS), CRITICAL AREAS, FORESTED AREAS, ARCHEOLOGICAL SITES, HISTORIC SITES, PARK LAND AND OPEN WATER. PORTIONS OF THIS PROJECT LIE WITHIN THE 100-YR FLOODPLAIN TEMPORARY STABILIZATION NOTES: 30.FOLLOWING INITIAL SOIL DISTURBANCE, PERMANENT OR TEMPORARY STABILIZATION SHALL BE COMPLETED WITHIN: A) THREE (3) CALENDAR DAYS FOR ALL PERIMETER SEDIMENT CONTROL STRUCTURES, DIKES, PERIMETER SLOPES AND ALL SLOPES GREATER THAN 3:1, B) SEVEN (7) DAYS AS TO ALL OTHER DISTURBED OR GRADED AREAS ON THE PROJECT SITE. MAINTENANCE OF SEDIMENT CONTROL NOTES: 31.THE CONTRACTOR SHALL, WITHOUT EXTRA COST TO THE PROJECT, REPAIR AND MAINTAIN EXISTING SEDIMENT CONTROL DEVICES UNTIL ALL AREAS WITHIN LIMITS OF CONSTRUCTION ARE STABILIZED. ALL SEDIMENT CONTROL MEASURES REFERRED TO ON THESE PLANS SHALL BE IN ACCORDANCE WITH PUBLISHED NORTH CAROLINA STANDARDS AND SPECIFICATIONS FOR EROSION AND SEDIMENT CONTROL DISTURBED AREA NOTES: 32.TRENCHES FOR ANY STORM DRAIN PIPE AND UNDERDRAIN PIPE INSTALLATIONS SHALL BE BACKFILLED, COMPACTED AND STABILIZED AT THE END OF EACH DAY. EROSION & SEDIMENTATION CONTROL - CONSTRUCTION SEQUENCING NOTES: 1.NO CONSTRUCTION OR LAND DISTURBANCE ACTIVITIES SHALL BEGIN UNTIL TEMPORARY SEDIMENT AND EROSION CONTROL MEASURES HAVE BEEN INSTALLED. CONTRACTOR SHALL INSTALL SILT FENCE AS SHOWN ON THE DRAWING FOR TEMPORARY PERIMETER EROSION CONTROL. 2.TEMPORARY SEEDING MEASURES SHALL BE EMPLOYED THROUGHOUT THE DURATION OF CONSTRUCTION ACTIVITIES ON ANY AREA WHICH WILL REMAIN UNDISTURBED FOR MORE THAN 7 WORKING DAYS OR 14 CALENDAR DAYS, WHICHEVER IS SHORTER. ALL SLOPES STEEPER THAN 3H:1V SHALL BE PLANTED OR OTHERWISE PROVIDED WITH TEMPORARY OR PERMANENT GROUND COVER, DEVICES, OR STRUCTURES SUFFICIENT TO RESTRAIN EROSION WITHIN 7 CALENDAR DAYS. ALL OTHER SLOPES OF 3H:1V OR FLATTER, EXCEPT THOSE GREATER THAN 50 FT IN LENGTH, SHALL BE PROVIDED WITH TEMPORARY OR PERMANENT GROUND COVER, DEVICES, OR OTHER STRUCTURES SUFFICIENT TO RESTRAIN EROSION WITHIN 14 CALENDAR DAYS. 3.PERMANENT SEEDING SHALL BE IMMEDIATELY INSTALLED, FOR ALL AREAS REACHING FINAL GRADE WHICH WILL NOT BE DISTURBED AGAIN. 4.UPON COMPLETION OF FINAL GRADING, PERMANENT STRUCTURAL OR VEGETATIVE STABILIZATION SHALL BE ESTABLISHED. 5.ALL EROSION AND SEDIMENTATION CONTROL MEASURES SHALL BE MAINTAINED THROUGHOUT THE DURATION OF CONSTRUCTION ACTIVITIES AND THE SITE HAS BEEN PERMANENTLY STABILIZED WITH STRUCTURAL AND/OR PERMANENT VEGETATIVE MEASURES. 6.CONTRACTOR SHALL PERFORM SITE INSPECTION AND MAINTENANCE ONCE EVERY SEVEN CALENDAR DAYS AND WITHIN 24 HOURS AFTER ANY STORM EVENT GREATER THAN 1/2 INCH OF RAIN PER 24 HOUR PERIOD. 7.ONCE PERMANENT STABILIZATION HAS OCCURRED, TEMPORARY SEDIMENT CONTROL MEASURES MAY BE REMOVED UPON APPROVAL FROM THE CITY. ANY AREAS DISTURBED BY THE REMOVAL OF EROSION CONTROL MEASURES SHALL BE RETURNED TO THE ORIGINAL, OR BETTER, CONDITION, THEN SEEDED, MULCHED, AND FERTILIZED. 8.THE NORTH CAROLINA SEDIMENTATION POLLUTION CONTROL ACT REQUIRES PEOPLE RESPONSIBLE FOR LAND DISTURBING ACTIVITIES TO INSPECT EROSION AND SEDIMENTATION CONTROL MEASURES AFTER EACH PHASE OF THE PROJECT UNTIL PERMANENT GROUND COVER IS ESTABLISHED. THE SELF INSPECTION PROGRAM IS SEPARATE FROM THE WEEKLY MONITORING PROGRAM OF THE NPDES STORMWATER PERMIT FOR CONSTRUCTION ACTIVITIES. THE FOCUS OF THE SELF-INSPECTION REPORT IS TO ENSURE THE INSTALLATION OF EROSION AND SEDIMENTATION CONTROL MEASURES ARE CONTINUALLY PERFORMING AS INTENDED. CONTROL OF WATER NOTES: 1.THE CONTRACTOR SHALL FURNISH AND INSTALL ALL EQUIPMENT, SUPPLIES, AND MATERIALS NECESSARY FOR THE CONTROL OF WATER, INCLUDING BUT NOT LIMITED TO: PUMPS, HOSE, SANDBAGS, DEWATERING DEVICES. 2.THE CONTRACTOR SHALL IMPLEMENT A CLEARWATER DIVERSION PLAN TO TEMPORARILY BYPASS FLOWS AROUND WORK AREAS. PUMPING MAY BE REQUIRED TO BYPASS FLOWS. 3.THE CONTRACTOR SHALL IMPLEMENT A WORK SITE DEWATERING PLAN TO DEWATER WORK AREAS AND TREAT WATER COLLECTED FROM DISTURBED AREAS. FLOWS COLLECTED FROM DISTURBED AREAS SHALL BE TREATED WITH AN APPROVED SEDIMENT CONTROL DEVICE PRIOR TO DISCHARGE. 4.ALL PUMPED FLOWS SHALL BE DISCHARGED IN A NON-EROSIVE MANNER TO A STABILIZED WATERCOURSE. 5.THE CONTRACTOR SHALL REMOVE OR MODIFY SANDBAG DIKES OR OTHER WATER CONTROL BARRIERS PRIOR TO FORECASTED RAIN EVENTS TO ALLOW FLOW THROUGH THE WATERCOURSE AS NEEDED TO MAINTAIN UPSTREAM FLOW WITHIN STREAM BANKS. 6.THE CONTRACTOR SHALL REMOVE CONSTRUCTION EQUIPMENT FROM THE WATERCOURSE AT THE END OF EACH WORK DAY AND PRIOR TO FORECASTED RAIN EVENTS. GG&CC IS NOT RESPONSIBLE FOR DAMAGE TO CONSTRUCTION EQUIPMENT. SEEDING NOTES: SEED BED PREPARATION 1.CONTRACTOR SHALL PREPARE ALL AREAS TO RECEIVE TEMPORARY OR PERMANENT SEEDING MEASURES PRIOR TO PLANTING. 2.TOPSOIL SHALL BE PLACED IN AREAS TO BE SEEDED AND ROUGHENED WITH TRACKED EQUIPMENT OR OTHER SUITABLE MEASURES. SLOPES STEEPER THAN 3:1 MAY BE ROUGHENED BY GROOVING, FURROWING, TRACKING, OR STAIRSTEP GRADING. SLOPES FLATTER THAN 3:1 SHOULD BE GROOVED BY DISKING, HARROWING, RAKING, OPERATING PLANTING EQUIPMENT ON THE CONTOUR. 3.SOIL AMENDMENTS INCLUDING, BUT NOT LIMITED TO, LIME AND FERTILIZER SHALL BE SPREAD AS NECESSARY, AND AT THE RATES SHOWN IN THE SEEDING SCHEDULE. SEEDING SHALL BE AS PER TYPE AND RATES SHOWN IN THE SEEDING SCHEDULE. SEED SHALL BE BROADCAST AS SOON AS POSSIBLE FOLLOWING ROUGHENING, BEFORE SURFACE HAS BEEN SEALED BY RAINFALL. MULCHING AND TACKING AGENTS 1.MULCH MUST COVER A MINIMUM OF 80 PERCENT OF THE SOIL SURFACE AND MUST BE SECURED BY TACKING, CRIMPING, OR NETTING. 2.WOOD CELLULOSE FIBER MULCH SHALL BE USED IN HYDROSEEDING GRASS SEED IN COMBINATION WITH FERTILIZERS AND OTHER APPROVED ADDITIONS. 3.NO NETTING WITH PLASTIC MESH AND / OR PLASTIC TWINE SHALL BE USED IN WETLAND AND RIPARIAN BUFFERS TO PROTECT SMALL ANIMALS. HYDROSEEDING 1.HYDROSEEDING SHALL BE CARRIED OUT IN THREE STEPS. STEP ONE SHALL CONSIST OF THE APPLICATION OF LIME. IN STEP TWO THE SEED MIXTURE SHALL BE MIXED WITH THE FERTILIZER, WOOD CELLULOSE FIBER MULCH, AND ANY REQUIRED INOCULANTS AND APPLIED TO THE SEED BED. STEP THREE SHALL CONSIST OF APPLICATION OF TOP DRESSING DURING THE FIRST SPRING OR FALL, WHICHEVER COMES FIRST, AFTER STEP TWO. 2.INGREDIENTS FOR THE MIXTURE AND STEPS SHOULD BE DUMPED INTO A TANK OF WATER AND THOROUGHLY MIXED TO A HOMOGENEOUS SLURRY AND SPRAYED OUT UNDER A MINIMUM OF 300-350 POUNDS PRESSURE, IN SUITABLE PROPORTIONS TO ACCOMMODATE THE TYPE AND CAPACITY OF THE HYDRAULIC MACHINE TO BE USED. APPLICATIONS SHALL BE EVENLY SPRAYED OVER THE GROUND SURFACE. THE CONTRACTOR SHALL FREE THE TOPSOIL OF STONES, ROOTS, RUBBISH AND OTHER DELETERIOUS MATERIALS AND DISPOSE OF SAME OFF THE SITE. THE BARE SOIL, EXCEPT EXISTING STEEP EMBANKMENT AREA, SHALL BE ROUGH RAKED TO REMOVE STONES, ROOTS, AND RUBBISH OVER 4-INCH IN SIZE, AND OTHER DELETERIOUS MATERIALS AND DISPOSE OF SAME OFF THE SITE. 3.NO SEEDING SHOULD BE UNDERTAKEN IN WINDY OR UNFAVORABLE WEATHER, WHEN THE GROUND IS TOO WET TO RAKE EASILY, WHEN IT IS IN A FROZEN CONDITIONS, OR TOO DRY. ANY BARE SPOTS SHOWN IN TWO TO THREE WEEKS SHALL BE RE-CULTIVATED, FERTILIZED AT HALF THE RATE, RAKED, SEEDED, AND MULCHED AGAIN BY MECHANICAL OR HAND BROADCAST METHOD ACCEPTABLE TO THE OWNER. SEQUENCE OF CONSTRUCTION PHASING (75% PLANS STAGE) PHASE 1 PHASE 1A (PRE-POSITIONING PRIOR TO 1/1/20) 1.CONDUCT PRE-CONSTRUCTION MEETING WITH CONTRACTOR, GG&CC PROJECT MANAGER, ENGINEER, AND AVERY COUNTY EROSION AND SEDIMENT CONTROL (ESC) INSPECTOR. 2.INSTALL STABILIZED CONSTRUCTION ENTRANCE (SCE) #1 AND PERIMETER SEDIMENT CONTROL DEVICES FOR STAGING AREA #1. 3.INSTALL SIPHON PIPING AND PUMPING. ESTIMATED CALENDAR DAYS: 30 DAYS PHASE 1B (EASTERN BANK EXCAVATION AT J-CLUSTER AND WESTERN LAKE PATH - CAN BEGIN PRIOR TO 1/1/20) 1.INSTALL SCE #3 AND ASSOCIATED PERIMETER SEDIMENT CONTROL FENCING 2.INSTALL WESTERN LAKE PATH IMPROVEMENTS. 3.INSTALL SCE #2 OFF OF CLUBHOUSE ACCESS ROAD, AND PERIMETER SEDIMENT CONTROL AND ACCESS PROTECTION INCLUDING SILT FENCE FOR TEMPORARY STOCKPILE AREA. 4.EXCAVATE FOR IMBRICATED ROCK WALL (IRW) #2 INSTALLATION ON LEFT (EAST) BANK DOWN TO, BUT NOT BELOW ORDINARY HIGH WATER. TEMPORARILY STABILIZE CUT BANK WITH COIR MATTING. 5.SEPARATE AND STOCKPILE ALL CLASS 1 AND 2 BOULDERS ON THE LEFT BANK ABOVE ORDINARY HIGHWATER FOR USE IN IRW CONSTRUCTION IN LATER PHASE. 6.TRUCK NON-BOULDER CUT MATERIAL TO TEMPORARY STOCKPILE AREA. ESTIMATED CALENDAR DAYS: 14 DAYS PHASE 1C (LOCH DEWATERING - CAN BEGIN 1/1/20) 1.DRAW LOCH DOWN APPROXIMATELY 8 FEET. MAINTAIN AT REDUCED DEPTH. ESTIMATED CALENDAR DAYS: 3 DAYS PHASE 1D (WEST CHANNEL DREDGE) 1.BLOCK ACCESS TO EXISTING PEDESTRIAN BRIDGES A, D, AND E. 2.INSTALL SCE #4 AND ASSOCIATED PERIMETER CONTROL DEVICES. 3.INSTALL FLOCCULANT TREATMENT IN OUTFALL CHANNEL AND TURBIDITY CURTAINS IN LOCH. 4.INSTALL DIVERSION #1 AND #2, TEMPORARILY DIVERTING LINVILLE RIVER THROUGH EASTERN (FAIRWAY 18) CHANNEL. MAINTAIN DIVERSION. 5.EXCAVATE WEST CHANNEL FROM UPSTREAM TO DOWNSTREAM (PUSHING MATEIAL DOWNSTREAM), TEMPORARILY STOCKPILING WET MATERIAL AS SHOWN. AVOID IMPACITNG ISLAND DRIVE BRIDGE AND ASSOCIATED WATERLINE. MOVE MATERIAL BENEATH BRIDGE F, KEEPING BRIDGE IN PLACE DURING THIS PHASE (ALTERNATIVELY, BRIDGE F REPLACEMENT WORK CAN BE COMPLETED AT THIS TIME; SEE PHASE 2B). GRADE AN INTERIM DRAINAGE CHANNEL APPROXIMATELY ALONG THE HISTORIC RIVER LOCATION THROUGH THIS AREA IN ANTICIPATION OF NEXT PHASE. ESTIMATED CALENDAR DAYS: 14 DAYS TOTAL PHASE 1 ESTIMATED CALENDAR DAYS STARTING 1/1/20: 17 DAYS PHASE 2 PHASE 2A (EAST CHANNEL DREDGE) 1.INSTALL DIVERSION #3 AND GRAVITY DIVERSION #1. 2.INSTALL DIVERSION #4 AND GRAVITY DIVERSION #2. 3.EXCAVATE EAST CHANNEL FROM UPSTREAM TO DOWNSTREAM (PUSHING MATERIAL DOWNSTREAM), TEMPORARILY STOCKPILING WET MATERIAL AND ACCEPTABLE SANDY-GRAVEL "DRY" MATERIAL AS SHOWN ON PLANS; SEPARATE OUT AND STOCKPILE ALL COBBLE MATERIAL SEPARATELY. ESTIMATED CALENDAR DAYS: 21 DAYS PHASE 2B (DEMOLITION AND NEW BRIDGE 4) 1.DEMO AND REMOVE FROM SITE BRIDGES A, B, C, D AND E INCLUDING ABUTMENTS, PIERS ETC PLUS OTHER DEMO ITEMS WITHIN THE LIMITS OF THIS PHASE. KEEP BRIDGES F AND G IN PLACE. 2.INSTALL TEMPORARY SANITARY BYPASS FOR BRIDGE E. 3.DEMO BRIDGE E AND ASSOCIATED SANITARY LINE. 4.INSTALL NEW SANITARY LINE AND NEW BRIDGE 4 WITH ABUTMENTS. 5.EXCAVATE EAST CHANNEL ESTIMATED CALENDAR DAYS: 14 DAYS PHASE 2C (ISLAND CREATION AND EVENT AREA GRADING) 1.UNDERCUT FOR ISLAND PERIMETER AND LOCHE WALLS AND INSTALL. 2.WASTE APPROVED AMOUNT OF WET MATERIAL WITHIN ISLAND FOOTPRINTS, FAIRWAY 18, AND EVENT LAWN AREA. 3.ROUGH GRADE ISLANDS WITH DRY MATERIAL. ROUGH GRADE FAIRWAY 18 FILL AND SHORELINE AREA, ISLAND DRIVE LAWN, AND CLUBHOUSE / EVENT LAWN AREA. ESTIMATED CALENDAR DAYS: 21 DAYS PHASE 2D (COMPLETE DREDGING) 1.COMPLETE REMAINDER OF DREDGING OPERATIONS PER FIELD DIRECTION BY THE ENGINEER. 2.REMOVE/MODIFY DIVERSIONS AS NECESSARY; DIVERSION 4 AND GRAVITY DIVERSION 2 TO REMAIN. 3.COMPLETE ISLAND GRADING WITH DRY MATERIAL AND CAP ISLANDS. COMPLETE FAIRWAY 18 FILL AND SHORELINE AREA GRADING, ISLAND DRIVE LAWN, GRADING AND CLUBHOUSE / EVENT LAWN AREA GRADING. ESTIMATED CALENDAR DAYS: 14 DAYS PHASE 2E (J-CLUSTER WALL INSTALLATION AND FAIRWAY 17 CROSSING) 1.INSTALL DIVERSION 5 AND GRAVITY DIVERSION 3. 2.HARVEST CLASS 1 AND 2 BOULDERS FROM FAIRWAY 17 STREAM CROSSING AND STOCKPILE FOR J-CLUSTER WALL USE AND BRIDGE 5 USE. 3.INSTALL GRADE CONTROL SILLS. 4.INSTALL IRW 1 AND 2. 5.GRADE FAIRWAY 17 CROSSING AREA UTILIZING REMAINING CUT FROM J-CLUSTER WORK. 6.REMOVE DIVERSION 5 AND GRAVITY DIVERSION 3. ESTIMATED CALENDAR DAYS: 21 DAYS PHASE 2F (SITE AMENITIES AND BRIDGE 5) 1.INSTALL NEW BRIDGES 1, 2 AND 3 INCLUDING ABUTMENTS. 2.INSTALL EVENT LAWN AMENITIES. 3.INSTALL TEMPORARY SANITARY BYPASS AT EXISTING BRIDGE G. 4.INSTALL NEW BRIDGE 5 WITH NEW SANITARY LINE AND MANHOLES; DEMOLISH BRIDGE G. 5.CONSTRUCT IRW #3. 6.REMOVE DIVERSION 4 AND GRAVITY DIVERSION 2. ESTIMATED CALENDAR DAYS: 21 DAYS PHASE 2G (LANDSCAPING AND DEMOBILIZATION) 1.INSTALL LANDSCAPING AMENITIES AS SHOWN ON PLAN SET. 2.REMOVE REMAINING SEDIMENT CONTROL FEATURES AND STABILIZE. ESTIMATED CALENDAR DAYS: 7 DAYS TOTAL PHASE 1 AND 2 ESTIMATED CALENDAR DAYS: 150 DAYS T. SCHUELER J. MCSWAIN J. MCSWAIN - - T. SCHUELER E000 EROSION & SEDIMENT CONTROL NOTES STABILIZATION TIMEFRAMES SITE AREA DESCRIPTION STABILIZATION TIMEFRAME EXCEPTIONS PERIMETER DIKES, SWALES, DITCHES, SLOPES 7 DAYS NONE HIGH QUALITY WATER (HQW) ZONES 7 DAYS NONE SLOPES STEEPER THAN 3:1 7 DAYS IF SLOPES ARE 10' OR LESS IN LENGTH AND ARE NOT STEEPER THAN 2:1, 14 DAYS ARE ALLOWED SLOPES 3:1 OR FLATTER 14 DAYS 7 DAYS FOR SLOPES GREATER THAN 50' IN LENGTH ALL OTHER AREAS WITH SLOPES FLATTER THAN 4:1 14 DAYS NONE, EXCEPT FOR PERIMETERS AND HQW ZONES TEMPORARY SEEDING SCHEDULE (SEASONAL) EARLY SUMMER SEASON FALL / WINTER SEASON SEEDING MIXTURE 40 LBS / ACRE OF GERMAN MILLET 80 LBS / ACRE OF TALL FESCUE 120 LBS / ACRE RYE (GRAIN) 80 LBS / ACRE TALL FESCUE SEEDING DATES MAY 1 - AUGUST 15 OCTOBER 25 - DECEMBER 30 REFERTILIZE IF GROWTH IS NOT FULLY ADEQUATE. BETWEEN DECEMBER 30 - FEBRUARY 15, ADD 50 LBS / ACRE OF ANNUAL KOBE LESPEDEZA. APPLY 4000 LBS / ACRE STRAW OR EQUIVALENT HYDROSEEDING. APPLY 4000 LBS / ACRE STRAW EQUIVALENT HYDROSEEDING. SEEDING AMENDMENTS APPLY LIME AND FERTILIZER PER SOIL TESTS OR 2000 LBS / ACRE LIMESTONE AND 750 LBS / ACRE 10-10-10 FERTILIZER. APPLY LIME AND FERTILIZER PER SOIL TESTS OR 2000 LBS / ACRE LIMESTONE AND 750 LBS / ACRE 10-10-10 FERTILIZER. SITE SUMMARY INFORMATION LIMITS OF DISTURBANCE (LOD):21.05 AC DRAINAGE AREA TO DAM:3.63 SQ MI EXISTING STREAM LENGTH:900 LF LENGTH OF STREAM IMPACTS:625 LF EXISTING OPEN WATERS:33.33 AC AREA OF OPEN WATER IMPACTS:11.39 AC AREA DISTURBED (EARTHEN):9.39 AC RECEIVING WATERS:LINVILLE RIVER (CLASS C; Tr) 00000000X XXXX00000000000000000000000000000000 0000 00000000 0000000000000000000000000000000000000000000000000000000 000000 00 000000000000000000000000000000000000000 000000000000000000000000000000000000000000000000000000000OOOOOOOOOOOOOOOOOOOOOO O OO O O O O O O O O X XXXXX XX W.E. 3787.9W.E. 3787.9W.E.: 3824.1ASPHALTA S P H A L TCREEK SOCC ER F I E L D BASKETBAL L COUR T GREENTRAPTRAPTRAPTRAP12" CMP10" CPP28" CPP24" CPPTELPEDNGS CM DAM N:865903.95E:1157252.32EL:3795.64OHE SSS S SSSS CREEKASPH A L T ROCK W A L LROCK WALLCONCRETESPILLWAYLINVILLE RIVERWEIR24" CMP(APPROXIMATE LOCATION)EX. WLEX.WLWOOD FENCEPSF S F SF SFSFSFTPATPATPATPATPATPATPATPATPATPATPATPATPATPATPATPATPATPATPAPSF PSFPSFPP PSFPSFTPFTP F TPFTPFPSFPSFPSFPSF PSF PSF PSF PSF PSF PSF PSF PSF PSF PSF PSF PSF PSF PSF PSFPSFPSFPSF P S F PS F PSF PS F PSF PSF PS F PSF SF SF SF SF SF SF SF SF SFSFSFSFSF S F SF SF SF SF SF SF SF SFPSFPSFPSFPSFPSFPSFPSFPSF PSFPSFPSFPSFSF S F SFSF SF SFSFSFSF SF SF SF S F SFSFSFS F P S F PSFPSFPS F PSF PSF PSF S F SFSF SF SF SF SF SF SF SF SF SF S F SFSFTC TCTC TCTCTCTCTCTCTCTCTCTCLODLODLODLODLODLO D LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLOD LODLODLODLOD LOD LOD LOD LODLOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODL O DLODLODLODLODLODLODLODLODLODL O D LO D LOD LOD L O D LODLODLODL O D LODLOD LODLOD LODLODLOD LOD LOD L O D L O D LODLOD LODLODLODLOD LODL O D LODLODLODLODLO D L O D LO D LOD LO D LODLODLODLODLODLO D LO D LOD LODLOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LODLODLODLODLODLODL O D LOD LOD LOD LOD LOD LODLODLODLODLODSCALE: 1" = 120' PLAN 60 1" = 120' 120 0 120'PLOT DATE: 8/14/2019 6:29 PM BY: SKANEFile: O:\32453-ATL\32453-002\CAD_BIM\ESC\E001 Saved by SKANE Save date: 8/12/2019 1:57 PM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 AUGUST 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. CHECKED BY: DRAWN BY: DESIGNED BY: LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 LANDSCAPE ARCHITECT: SUPPORTING ENGINEER: LI N V I L L E R I V E R HW Y 1 0 5 C L U B H O U S E D R . GR A S S Y C R E E K R D WO O D C H U C K R D IS L A N D D R CLUBHOUS E D R APPROXIMATE DRAWN DOWN ELEVATION = 3779.5 WEST CHANNE L EA S T C H A N N E L PRINCIPAL SPILLWAY WEIR BRIDGE STAGING AREA #1 PHASE 1A / 1C SIPHON / PUMP SYSTEM FOR TEMPORARILY DEWATERING LOCH DORNIE DIVERSION #1 PHASE 1A & 1C SCE #1 SCE #3 SCE #4 PEDESTRIAN SAFETY FENCE, TYP LIMITS OF DISTURBANCE, TYP FL O W LOCH DORNIE DRAWN DOWN APROXIMATELY 8 FEET FAIRWAY 18 CLUBHOUSE SCE #6 OFFICE BUILDING MAINTENANCE BUILDING CLIFTON PARK LOCH DORNIE NORMAL POOL ELEVATION = 3787.5 T. SCHUELER J. MCSWAIN J. MCSWAIN - - T. SCHUELER E001 EROSION & SEDIMENT CONTROL PHASE 1 OF 2 PHASE 1B DIVERSION #2 SCE #2 A B C E F D G INTERIM DRAINAGE CHANNEL CONSTRUCTION MAT ACCESS PATH SILT FENCE, TYP TEMPORARY WET MATERIAL STOCKPILE TEMPORARY DRY MATERIAL STOCKPILE PHASE 1B EASTERN BANK EXCAVATION AT J-CLUSTER PHASE 1B SITE ACCESS AND TEMPORARY STOCKPILE OF EXCAVATED MATERIAL PHASE 1D WEST CHANNEL DREDGE PHASE 1B PHASE 1D ENVIRONMENTAL RELEASE PIPE FLOW TO HAVE FLOCCULANT LOG TREATMENT IN OUTFALL CHANNEL LINVILLE RIVERTURBIDITY CURTAIN, TYP TURBIDITY CURTAIN, TYP 00000000X XXXX00000000000000000000000000000000 0000 00000000 000000000000000000000000000000000000000000000000000000 0 00000000000000000000000000000000000000000000000 000000000000000000000000000000000000000000000000000000000OOOOOOOOOOOOOOOOOOOOOO OOOO O O O O O O O X XXXXX XXASPHALTA SPH A L TCREEKTRAP TRAPTRAP12" CMP10" CPP28" CPP24" CPPTELPEDNGS CM DAM N:865903.95E:1157252.32EL:3795.64OHE SSS S SSSS CREEKAS PHA L T ROCK W A L LROCK WALLCONCRETESPILLWAYLINVILLE RIVERWEIR24" CMP(APPROXIMATE LOCATION)EX. WLEX.WLXXPSF S F S F SFSFSFTPATPATPATPATPATPATPATPATPATPATPATPATPATPATPATPATPATPATPAPSF PSFPSFPP PSFPSFTPFTP F TPFTPFPSFPSFPSFPSF PSF PSF PSF PSF PSF PSF PSF PSF PSF PSF PSF PSF PSF PSF PSFPSFPSFPSF P S F P S F PSF PS F PSF PSF PS F PSFSFSFSF S F SF SF SF SF SF SF SF SFPSFPSFPSFPSFPSFPSFPSFPSF PSFPSFPSFPSFP S F PSFPSFPS F PSF PSF PSF SF SF S F S F SF SF SF SF SF TC TCTC TCTCTCTCTCTCTCTCTCTCLODLODLODLODLODLO D LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLOD LODLODLODLOD LOD LOD LOD LODLOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODL O DLODLODLODLODLODLODLODLODLODL O D LO D LOD LOD L O D LODLODLODL O D LODLOD LODLOD LODLODLOD LOD LOD L O D L O D LOD LOD LODLODLODLOD LODL O D LODLODLODLODLO D L O D LO D LOD LO D LODLODLODLODLODLO D LO D LOD LODLOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LODLODLODLODLODLODL O D LOD LOD LOD LOD LOD LODLODLODLODLODSCALE: 1" = 120' PLAN 60 1" = 120' 120 0 120'PLOT DATE: 8/14/2019 6:30 PM BY: SKANEFile: O:\32453-ATL\32453-002\CAD_BIM\ESC\E002 Saved by SKANE Save date: 8/12/2019 2:42 PM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 AUGUST 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. CHECKED BY: DRAWN BY: DESIGNED BY: LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 LANDSCAPE ARCHITECT: SUPPORTING ENGINEER:LINV ILLE R IVERWEST CHANNE L EA S T C H A N N E L HW Y 1 0 5 C L U B H O U S E D R . GR A S S Y C R E E K R D W O O D C H U C K R D IS L A N D D R CLUBHOUS E D R FLOWGRAVITY DIVERSION #2 DIVERSION #3 APPROXIMATE DRAWN DOWN ELEVATION = 3779.5 LOCH DORNIE NORMAL POOL ELEVATION = 3787.5 FAIRWAY 18 CLUBHOUSE PHASE 2A OFFICE BUILDING MAINTENANCE BUILDING T. SCHUELER J. MCSWAIN J. MCSWAIN - - T. SCHUELER E002 EROSION & SEDIMENT CONTROL PHASE 2 OF 2 PHASE 2B PHASE 2C PHASE 2D PHASE 2E PHASE 2F GRAVITY DIVERSION #3 DIVERSION #4 DIVERSION #5 GRAVITY DIVERSION #1 PRINCIPAL SPILLWAY WEIR BRIDGE LOCH DORNIE DRAWN DOWN APROXIMATELY 8 FEET SCE #3 SCE #4 PEDESTRIAN SAFETY FENCE, TYP LIMITS OF DISTURBANCE, TYP DIVERSION #2 SCE #2 TEMPORARY WET MATERIAL STOCKPILELINVILLE RIVERSTAGING AREA #1 PHASE 1A / 1C SIPHON / PUMP SYSTEM FOR TEMPORARILY DEWATERING LOCH DORNIE PHASE 1A & 1C SCE #1 CLIFTON PARK SILT FENCE, TYP TURBIDITY CURTAIN, TYP ENVIRONMENTAL RELEASE PIPE FLOW TO HAVE FLOCCULANT TREATMENT (LOG OR BLOCK) IN OUTFALL CHANNEL TURBIDITY CURTAIN, TYP 3860385538503845384038403835383038 2 0 383538 2 0 3 8 1 5 3830381038153815 3832 3810381538203830 3835 3840 XBUILDING J BUILDING J CART PATHLINVILLE RIVERLINV ILLE R IVER CART PATHCART PATH FAIRWAY 17 2 0 " CM P 8 " D IP LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LODLODLODLODLODLODLODLODLODLODLODLODLODL O D LOD LOD LODLODLODLODLOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODXXXXXXXXXXX3814 3814 3816 3817 3818 3819 3820 3815 3816 3817 3818 3819 3820 3821 3822 382 43825 3821382238233810381538203825383038353815-0+001+00 2+003+00 4+00 5+00 PSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSF PSF PSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSF LODLODLODLOD LODLODLODPSFPSFPSFPSF15 1" = 30' 30 0 30'PLOT DATE: 8/14/2019 6:31 PM BY: SKANEFile: O:\32453-ATL\32453-002\CAD_BIM\ESC\E101 Saved by SKANE Save date: 8/12/2019 2:36 PM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 AUGUST 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. CHECKED BY: DRAWN BY: DESIGNED BY: LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 LANDSCAPE ARCHITECT: SUPPORTING ENGINEER: MATCH LINE - SEE DWG E102 SCALE: 1" = 30' PLAN T. SCHUELER S. KANE J. MCSWAIN - - T. SCHUELER E101 EROSION & SEDIMENT CONTROL PLAN AREA 1 1 2 4 3 5 6 7 7 GCS1 PHASE 1B POTENTIAL BOULDER HARVEST AREA; SEE NOTE 3 PHASE 2E IRW #2 PHASE 2E IRW #1 FOR IMBRICATED ROCK WALL (IRW) DESIGN INFORMATION SEE DWG C300 FOR GRADE CONTROL SILL (GCS) DESIGN INFORMATION SEE DWG C300 GCS2 GCS3 GCS 4 PEDESTRIAN SAFETY FENCE, TYP LIMITS OF DISTURBANCE, TYP CONSTRUCTION MAT ACCESS PATH, TYP SILT FENCE, TYP PHASE 1B EASTERN BANK EXCAVATION AT J-CLUSTER PHASE 2E GRAVITY DIVERSION #3 PHASE 2E DIVERSION #5 PHASE 1B TEMPORARY COIR MAT STABILIZATION FOR EASTERN BANK STABILIZATON NOTES: 1.THIS SHEET CONTAINS EROSION & SEDIMENT CONTROL MEASURES FOR MULTIPLE PHASES OF CONSTSRUCTION. 2.SEE DWG E000 FOR SEQUENCE OF CONSTRUCTON NOTES. 3.SEE DWGS E001-E002 FOR OVERALL PHASING PLANS THAT INCLUDE PHASING FOR WATER HANDLING, DREDGING, AND EARTHWORK. 4.SEE DWGS E201-E203 FOR SEDIMENT & EROSION CONTROL DETAILS. 5.EXISTING GIS CONTOURS USED FOR TOPOGRAPHY OUTSIDE OF SURVEY. 6.AERIAL IMAGERY WAS USED TO DETERMINE A PORTION OF THE GOLF CART PATH, GOLF CART BRIDGE, AND FAIRWAY BOUNDS. 7.BOULDER HARVEST AREA LIMITS TO BE DEFINED AT NEXT DESIGN STAGE SEE INSET 1 SCALE: 1" = 30' INSET 1 3788 3785 3786 37 8 8 37853790 3795 38003 8 1 5 3 8 2 0 38153810381038153820381538003795 3800381038153830383038353840384538503820 3815 381538203830 3835 3800 3795 3790 3805 3800 3795 3790 378538053 8 0 0 3 8 0 5 3 8 1 0 3810 3815 3 8 0 5 3 8 0 0 379037950000 0 0 0 0 00000000XXXXXXXXXXXXX0 00000000000000 00 00000 W.E.: 3824.1 BUILDING H BUILDING H BUILDING C 10" CPP 18 " C P P 24" CM P 18" CPPSSSSSSSS8" TRUSS(A)SSSS8" TRUSSSSSSSSSS8" TRUSS4" PV C 4" PVC8" TRUSS8" TRUSS 4" PVC8" TRUSS8" TRUSS 8" TR U S SLINVILLE RIVERCART PATHCART PATHCART PATH I S L A N D D R I V E BUILDING C UPP E R L O C H D O R NI E WES T C H A N N EL UPPER LOCH DORN IEEAST CHANNEL GREEN 17 TEE 18 TEE 18 TEE 18 TEE 18 FAIRWAY 17 15 " C P P LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODL O D L O D LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLOD LODLODL O D LODLODLOD LOD LODL O D L O D L O D LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LO DXXX378137833781378337873787378738113808 6+00 7+00 8+009+00 10+00 11+00 50+00 51+00 52+00 158.53°'103.02°'77.10°'TPFTPFTPFTPF PSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSF PSF PSF PSF PSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSF SF SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFPSFPSFPSFPSFPSF15 1" = 30' 30 0 30'PLOT DATE: 8/14/2019 6:32 PM BY: SKANEFile: O:\32453-ATL\32453-002\CAD_BIM\ESC\E102 Saved by JMCSWAIN Save date: 7/7/2019 5:39 PM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 AUGUST 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. CHECKED BY: DRAWN BY: DESIGNED BY: LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 LANDSCAPE ARCHITECT: SUPPORTING ENGINEER: MATCH LINE - SEE DWG E103 SCALE: 1" = 30' PLAN MATCH LINE -SEE DWG E104COBBLE DEPOSITION TO BE REMOVED AND REUSED FOR NEW ISLAND PROTECTION; FOREBAY POOL TO BE EXCAVATED SSMH TOP ELEV: 3811.33 8" DIP IN (SW) I.E.: 3808.21 4" HDPE IN (SE) I.E.: 3808.00 8" TRUSS IN (NE) I.E.: 3807.37 8" TRUSS OUT (NW) I.E: 3801.28 SSMH TOP ELEV: 3808.32 SSMH TOP ELEV: 3822.56 SSMH TOP ELEV: 3821.39 SSMH TOP ELEV: 3806.21 SSMH TOP ELEV: 3831.00 MATCH LINE - SEE DWG E101 T. SCHUELER S. KANE J. MCSWAIN - - T. SCHUELER E102 EROSION & SEDIMENT CONTROL PLAN AREA 2 1 2 4 3 5 6 7 7 FOR PROPOSED SANITARY SEWER WORK, SEE DWG C400 IRW #3 (0.8:1) FOR IMBRICATED ROCK WALL (IRW) DESIGN INFORMATION SEE DWG C300 FOR PROPOSED BRIDGE 5 WORK, SEE DWG B501 - B504 PHASE 2 GRAVITY DIVERSION #2 PHASE 2F DIVERSION #4 SILT FENCE, TYP PEDESTRIAN SAFETY FENCE, TYP LIMITS OF DISTURBANCE, TYP PHASE 1D DIVERSION #1 CONSTRUCTION MAT ACCESS PATH, TYP TIMBER MAT ACCESS PATH FROM SCE #4 NOTES: 1.THIS SHEET CONTAINS EROSION & SEDIMENT CONTROL MEASURES FOR MULTIPLE PHASES OF CONSTSRUCTION. 2.SEE DWG E000 FOR SEQUENCE OF CONSTRUCTON NOTES. 3.SEE DWGS E001-E002 FOR OVERALL PHASING PLANS THAT INCLUDE PHASING FOR WATER HANDLING, DREDGING, AND EARTHWORK. 4.SEE DWGS E201-E203 FOR SEDIMENT & EROSION CONTROL DETAILS. PHASE 1DIVER T F LOW THROUGHEAST CHANNE L PHAS E 2 DIVE R T F L O W T H R O U G H WEST C H A N N E L 37833 7 8 2 3790 3795 3785 3783 378637833850384538403835383038253820380037953785 378537953790379537903795379537903800 3 8 0 0 3 7 9 5 3 7 9 0 38 0 0 3 7 9 5 3805 38003790379537903 7 9 0 3 7 9 5000 0 0 0 0 00000000OO XXX0 00000000000 00 00000 000W.E. 3787.9 W.E. 3787.9 BUILDING BUILDING BUILDING BUILDING C BUILDING C BUILDING B BUILDING A BUILDING A BUILDING E BUILDING E BUILDING D BUILDING D BUILDING D 30" C M P 24" CM P 18" CMP 18" CPP6" P V C ( B )SSSS12" PVC 12" TRUSS(E)SSSSSS SSSSSSSSSSSS24" CPPUPPER LOCH DORNIEWEST CHANNEL8" TRUSS(A) BUILDING C UPPER LOCH DORNIEEAST CHANNELTEE 18 FAIRWAY 18UPPER LOCH DORN IEEAST CHANNEL ISLAND DRIV E ISLAND D R I V E LODLODLODLODL O D LOD LODLOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLO D LOD LOD LODLOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LODLODLODLODLODLODLODLODLOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LODLODLODLODLODLODLOD LO D L O D 3 7 8 2 378237813783378337873784378337853 7 8 7 3 7 8 5 3785378737833 7 9 03791 378437823 78 23783378337833 7 8 3 3790379137893785378511+00 12+00 13+00 14+00 15+00 16+00 52+00 53+00 54+00 55+00 56+00 57+00 PSFPSFPSFPSFPSFPSFSFSFSFSFSFSFSF SF PHASE 1DIVERT FLOW THROUGHEAST CHANNEL 15 1" = 30' 30 0 30'PLOT DATE: 8/14/2019 6:33 PM BY: SKANEFile: O:\32453-ATL\32453-002\CAD_BIM\ESC\E103 Saved by SKANE Save date: 8/12/2019 2:44 PM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 AUGUST 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. CHECKED BY: DRAWN BY: DESIGNED BY: LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 LANDSCAPE ARCHITECT: SUPPORTING ENGINEER: MATCH LINE - SEE DWG C202 MATCH LINE - SEE DWG E104MATCH LINE - SEE DWG E105 SCALE: 1" = 30' PLAN EX. ISLAND DRIVE BRIDGE SSMH TOP ELEV: 3811.80 SSMH TOP ELEV: 3803.20 SSMH TOP ELEV: 3802.74 SSMH TOP ELEV: 3811.38 T. SCHUELER S. KANE J. MCSWAIN - - T. SCHUELER E103 EROSION & SEDIMENT CONTROL PLAN AREA 3 1 2 4 3 5 6 7 7 PHASE 2DIVERT FLOW THROUGHWEST CHANNELLIMITS OF DISTURBANCE, TYP NOTES: 1.THIS SHEET CONTAINS EROSION & SEDIMENT CONTROL MEASURES FOR MULTIPLE PHASES OF CONSTSRUCTION. 2.SEE DWG E000 FOR SEQUENCE OF CONSTRUCTON NOTES. 3.SEE DWGS E001-E002 FOR OVERALL PHASING PLANS THAT INCLUDE PHASING FOR WATER HANDLING, DREDGING, AND EARTHWORK. 4.SEE DWGS E201-E203 FOR SEDIMENT & EROSION CONTROL DETAILS. SCE #4 PEDESTRIAN SAFETY FENCE, TYP CONSTRUCTION MAT ACCESS PATH, TYP SILT FENCE, TYP TEMPORARY STOCKPILE 3785 3785 37903792 37 9 5 3 8 0 0 3 8 0 5 3 8 0 5 380038 3 038253 8 2 0 381 500000000000000000000000000000 0 0 0 0 0 0 0 0 0 0 000000 000000000000000000 000000000000000000000000000000000000000000000000000000000000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0000 0 0XXXXXXXXXBUILDING BUILDING24" CPP24" CPP24" CPPC A R T P A T H C A R T P A T H A S P H A L T FAIRWAY 18 FAIRWAY 18 LOCH DORNIE LODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LODLODLO D L O D L O D LO D LOD LO D L O D L O D L O D L O D L O D L O D L O D L O D L O D L O D L O D L O D LOD L O D L O D L O D LO D LOD LOD LO D LO D LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODL O D L O D L O D L O D L O D L O D L O D L O D L O D L O D 37823781 3 7 9 3 3 7 9 1 3790 3787 3783 3785 3 7 9 0 PSF PSF PSF PSF PSF PSF PSF PSF PSF PSF PSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFPSFPSFPSFPSFPSFPSFPSFPSFP S F P S F P S F P S F P S F P S F P S F P S F P S F P S F P S F P S F P S F P S F P S F SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFTEMPO R A R Y STOCK P I L E 15 1" = 30' 30 0 30'PLOT DATE: 8/14/2019 6:34 PM BY: SKANEFile: O:\32453-ATL\32453-002\CAD_BIM\ESC\E104 Saved by JMCSWAIN Save date: 7/7/2019 12:53 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 AUGUST 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. CHECKED BY: DRAWN BY: DESIGNED BY: LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 LANDSCAPE ARCHITECT: SUPPORTING ENGINEER:MATCH LINE - SEE DWG E103MATCH LINE - SEE DWGS E105 & E106 SCALE: 1" = 30' PLAN PHASE 2C / 2D FAIRWAY 18 PROPOSED FILL AND SHORELINE STABILIZATION MATCH LINE - SEE DWG C202 T. SCHUELER S. KANE J. MCSWAIN - - T. SCHUELER E104 EROSION & SEDIMENT CONTROL PLAN AREA 4 1 2 4 3 5 6 7 7 4" CPP INV: 3791.38 4" CPP INV: 3788 PEDESTRIAN SAFETY FENCE, TYP LIMITS OF DISTURBANCE, TYP CONSTRUCTION MAT ACCESS PATH, TYP SILT FENCE, TYP PHASE 1B SITE ACCESS AND TEMPORARY STOCKPILE OF EXCAVATED MATERIAL NOTES: 1.THIS SHEET CONTAINS EROSION & SEDIMENT CONTROL MEASURES FOR MULTIPLE PHASES OF CONSTSRUCTION. 2.SEE DWG E000 FOR SEQUENCE OF CONSTRUCTON NOTES. 3.SEE DWGS E001-E002 FOR OVERALL PHASING PLANS THAT INCLUDE PHASING FOR WATER HANDLING, DREDGING, AND EARTHWORK. 4.SEE DWGS E201-E203 FOR SEDIMENT & EROSION CONTROL DETAILS. PHASE 2C / 2D 3D GEOMAT (ENKAMAT) SHORELINE STABILIZATION CONNECT 4" CPP TO EXISTING DRAIN PIPE AND EXTEND NEW LENGTH TO WATERS EDGE PH A S E 2 DIV E R T F L O W T H R O U G H WE S T C H A N N E L 378337843790 3795 3782 3790378537923785378037903785 3785 379537900000 0000000 0000000XX X X BUILDING BUILDING BUILDING BUILDING 6" CMP12" CMP4" CPP3 6 " C M P 1 2 " T R U S S ( F ) S S S S 6" PVC ( I ) 6" PV C( H)SS1 2 " TRUSS ( J )SSSSSS6" P V C SS SS 4" CIPSSSSSSSSSSSSSS1 2 " TRUSS (P )6" PVCSSLOC H D O R NI E D RI V E BUILDING E U P P E R L O C H D O R N I E W E S T C H A N N E L LOCH DORNIE LOCH DORNIE LOCH DORNIELODL O D L O D L O D LODLOD LOD LODLODLOD LOD LOD LOD LODLODLODLOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD3782 3 7 8 2 3781 3780 3780 3779377937803 780 3779 3783 3781 3781 37823 7 8 1 3781 3 7 9 1 3790 3785 3787 3783 3 7 8 5 3 7 8 7 3 7 9 03791 3 7 8 5 3 7 8 7 37893 7 8 4 37843 7 8 4 3 7 8 4 3 7 8 0 3782 37823 7 8 4 37933793379238003802379 6 3791379337933793 3790 379037943 7 9 03790378217+00 18+00 58+00 59+00 59+50 PSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFTP F TPF TPF TPF TPF TPF TPFTPFTPFTPF PSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFSF SF SFSFSF PH A S E 1 DIV E R T F L O W T H R O U G H EA S T C H A N N E L 15 1" = 30' 30 0 30'PLOT DATE: 8/14/2019 6:36 PM BY: SKANEFile: O:\32453-ATL\32453-002\CAD_BIM\ESC\E105 Saved by JMCSWAIN Save date: 7/6/2019 8:36 PM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 AUGUST 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. CHECKED BY: DRAWN BY: DESIGNED BY: LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 LANDSCAPE ARCHITECT: SUPPORTING ENGINEER: MATCH LINE - SEE DWG E103 MATCH LINE -SEE DWG E106SCALE: 1" = 30' PLAN MATCH LINE - SEE DWG E107 MATCH LINE - SEE DWG E104 PHASE 2C / 2D ISLAND CREATION; SEE DWG C300 FOR ISLAND PERIMETER BERM DETAIL PHASE 2C / 2D ISLAND DRIVE LAWN FILL AND SHORELINE STABILIZATION SSMH TOP ELEV: 3808.08 SSMH TOP ELEV: 3800.89 SSMH TOP ELEV: 3796.01 6" PVC IN I.E.: 3793.97 6" TRUSS(G) OUT I.E.: 3793.89 SSMH TOP ELEV: 3798.25 SSMH TOP ELEV: 3795.52 T. SCHUELER S. KANE J. MCSWAIN - - T. SCHUELER E105 EROSION & SEDIMENT CONTROL PLAN AREA 5 1 2 4 3 5 6 7 7 FOR PROPOSED BRIDGE 4 WORK, SEE DWG B401 - B404 FOR PROPOSED BRIDGE 3 WORK, SEE DWG B301 - B307 FOR PROPOSED SANITARY SEWER WORK, SEE DWG C400 DIVERSION #2 SCE #3 PHASE 2 GRAVITY DIVERSION #1 NOTES: 1.THIS SHEET CONTAINS EROSION & SEDIMENT CONTROL MEASURES FOR MULTIPLE PHASES OF CONSTSRUCTION. 2.SEE DWG E000 FOR SEQUENCE OF CONSTRUCTON NOTES. 3.SEE DWGS E001-E002 FOR OVERALL PHASING PLANS THAT INCLUDE PHASING FOR WATER HANDLING, DREDGING, AND EARTHWORK. 4.SEE DWGS E201-E203 FOR SEDIMENT & EROSION CONTROL DETAILS. TREE PROTECTION FENCE, TYP LIMITS OF DISTURBANCE, TYP PEDESTRIAN SAVETY FENCE, TYP PHASE 2C / 2D SHORELINE GRADING AND STABILIZATION WITH 3D GEOMAT (ENKAMAT) 3D GEOMAT (ENKAMAT), TYP PHASE 1A PATH IMPROVEMENTS PHASE 2 DIVERSION #3 PHASE 2 GRAVITY DIVERSION #1 SILT FENCE, TYP 37833790378537843 7 9 2 37 9 0 378 5 379237923785 3780 37803782 3785 3785 380538 1 5 3815380538003 7 9 5 3 7 9 03795 XXXXXXXXXBLDG BLDG BLDG BUILDING 1 8 " C P P 70" C P P A S P H A L T ASP H A L T LOCH DORNIE GREEN 18 FAIRWAY 18 LOCH DORNIE LOCH DORNIE LOCH DORNIE LO D LOD LOD LOD L O D L O D LO D LOD LODLODLODLODLODLODLODLODLODLODLOD LODLODLODLODLODL O D L O D LODLODLODLODLODLODLODLODLODLOD LO D LO D LOD LODLODLODLODLODLODLODLOD LODLODLODLODLODLODLODL O D L O D L O D LODLODLOD780 3780 3 7 7 9 3779377937803780 377937823 7 8 1 3781 3 7 91 3790 3785 3787 3783 3 78 3 3 7 8 0 37 8 0 3782 37823 7 7 53793379037943 7 9 037903782 3 7 9 3 3 7 9 3 3 7 8 1 3 7 8 1 3790 3 7 9 0 3 7 8 8 3 7 9 0 3 7 7 7 3795 3796 3797 3800 3802 17+00 18+00 19+00 20+00 21+00 22+00 23+00 24+00 24+06 TP F TPF TPFTPFTPFTPFTPFTPFTPFTPFTPFTPFTPFTPFPSFPSFPSFPSFPSFPSFPSFPSFPSFPSFP S F P S F P S F P S F P S F PSFPSFPSFSFSFSFSFSFSFSFSFSFSFSFSFSF SF SFSFSFSFSFSFSFSFSFSFSFSF SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFTC TCTCTCTCTC TC P H A S E 2 D I V E R T F L OW T H R O U G HWE S T C H A N N E L TEMPORARY STOCKPILE PLOT DATE: 8/14/2019 6:37 PM BY: SKANEFile: O:\32453-ATL\32453-002\CAD_BIM\ESC\E106 Saved by JMCSWAIN Save date: 7/6/2019 9:52 PM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 AUGUST 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. CHECKED BY: DRAWN BY: DESIGNED BY: LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 LANDSCAPE ARCHITECT: SUPPORTING ENGINEER: MATCH LINE - SEE DWG E104 MATCH LINE - SEE DWGS E105 & E106 MATCH LINE - SEE DWG E107 SCALE: 1" = 30' PLAN 15 1" = 30' 30 0 30' CLUBHOUSE SCE #2 RETAINING WALL, SEE DETAIL DWG W100 - W101 T. SCHUELER S. KANE J. MCSWAIN - - T. SCHUELER E106 EROSION & SEDIMENT CONTROL PLAN AREA 6 1 2 4 3 5 6 7 7 LARGE ISLAND SMALL ISLAND 4" CPP INV: 3788 NOTES: 1.THIS SHEET CONTAINS EROSION & SEDIMENT CONTROL MEASURES FOR MULTIPLE PHASES OF CONSTSRUCTION. 2.SEE DWG E000 FOR SEQUENCE OF CONSTRUCTON NOTES. 3.SEE DWGS E001-E002 FOR OVERALL PHASING PLANS THAT INCLUDE PHASING FOR WATER HANDLING, DREDGING, AND EARTHWORK. 4.SEE DWGS E201-E203 FOR SEDIMENT & EROSION CONTROL DETAILS. NOTES: 1.THIS SHEET CONTAINS EROSION & SEDIMENT CONTROL MEASURES FOR MULTIPLE PHASES OF CONSTSRUCTION. 2.SEE DWG E000 FOR SEQUENCE OF CONSTRUCTON NOTES. 3.SEE DWGS E001-E002 FOR OVERALL PHASING PLANS THAT INCLUDE PHASING FOR WATER HANDLING, DREDGING, AND EARTHWORK. 4.SEE DWGS E201-E203 FOR SEDIMENT & EROSION CONTROL DETAILS. NOTES: 1.THIS SHEET CONTAINS EROSION & SEDIMENT CONTROL MEASURES FOR MULTIPLE PHASES OF CONSTSRUCTION. 2.SEE DWG E000 FOR SEQUENCE OF CONSTRUCTON NOTES. 3.SEE DWGS E001-E002 FOR OVERALL PHASING PLANS THAT INCLUDE PHASING FOR WATER HANDLING, DREDGING, AND EARTHWORK. 4.SEE DWGS E201-E203 FOR SEDIMENT & EROSION CONTROL DETAILS. NOTES: 1.THIS SHEET CONTAINS EROSION & SEDIMENT CONTROL MEASURES FOR MULTIPLE PHASES OF CONSTSRUCTION. 2.SEE DWG E000 FOR SEQUENCE OF CONSTRUCTON NOTES. 3.SEE DWGS E001-E002 FOR OVERALL PHASING PLANS THAT INCLUDE PHASING FOR WATER HANDLING, DREDGING, AND EARTHWORK. 4.SEE DWGS E201-E203 FOR SEDIMENT & EROSION CONTROL DETAILS. 5.FOR PROPOSED BRIDGE WORK SEE DWGS B000-B504 PHASE 2C / 2D ISLAND CREATION; SEE DWG C300 FOR ISLAND PERIMETER BERM DETAIL DIVERSION #2 TREE PROTECTION FENCE, TYP PHASE 2C / 2D SHORELINE GRADING AND STABILIZATION WITH 3D GEOMAT (ENKAMAT) 3D GEOMAT (ENKAMAT), TYP TURBIDITY CURTAIN, TYP PEDESTRIAN SAFETY FENCE, TYP LIMITS OF DISTURBANCE, TYP CONSTRUCTION MAT ACCESS PATH, TYP SILT FENCE, TYP PHASE 2C / 2D PROPOSED EVENT LAWN GRADING PHASE 2 GRAVITY DIVERSION #1 LOCH DORNIE DRAWN DOWN APROXIMATELY 8 FEET 3795 3795379037953790BUILDING 36" CM P 24" CPP 24" CPP15" C M PSSSS SS SS 6" P V C 6" PVC12" TRUSS(S)SSSSSSSS6" PVCSS SS SS SS12" TRUSS(U)12" T R U S S ( T )12" TRUSS(R)12" TR U S S ( Q ) LOCH DORNIE EX. WL LODLODLODLODLODLOD L O D LOD LODLODLODLODLODLODLODLODLODLODLOD LOD LODLODLODLODLODLODLOD LOD LOD LO D LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD3 7 8 7 3 7 8 5 3785378 9 37 8 8 3 7 8 5 3 784 3790 37 9 3 37903787SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSF SF SF SF TC 3810 3805 3800 3795 37753820 3815 3810 3805 BUILDING 24" CPP 24" CP P 6" PVC 12" TRU S S( V)SSSS12" TRUSS(W)SSSSSS12" TRUSS(X)SSSSSSSSSS12" TRUSS(U)WOODCHUCK ROAD CLUB H O U S E D RI V E LOCH DORNIE EX. WL OHEWOOD FENCE 24" CMP LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LODLODLODLODLOD LOD LOD LOD LOD LODLODLODLODLOD37903793SFSFSFSFSFSFSFSFSFSF SF SF SF SF SFSFSFSFSFSFPLOT DATE: 8/14/2019 6:38 PM BY: SKANEFile: O:\32453-ATL\32453-002\CAD_BIM\ESC\E107 Saved by SKANE Save date: 8/12/2019 2:49 PM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 AUGUST 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. CHECKED BY: DRAWN BY: DESIGNED BY: LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 LANDSCAPE ARCHITECT: SUPPORTING ENGINEER: MATCH LINE - SEE THIS SHEET MATCH LINE - SEE THIS SHEETMATCH LINE - SEE DWG E105 SCALE: 1" = 30' PLAN MATCH LINE - SEE DWG E106 SSMH TOP ELEV: 3798.84 SSMH TOP ELEV: 3798.49 SSMH TOP ELEV: 3794.35 SSMH TOP ELEV: 3792.97 SSMH TOP ELEV: 3793.89 SSMH TOP ELEV: 3794.33 SSMH TOP ELEV: 3795.20 T. SCHUELER S. KANE J. MCSWAIN - - T. SCHUELER E107 EROSION & SEDIMENT CONTROL PLAN AREA 7 PHASE 1A WESTERN LAKE PATH IMPROVEMENTS SCALE: 1" = 30' PLAN 15 1" = 30' 30 0 30' 1 2 4 3 5 6 7 7 NOTES: 1.THIS SHEET CONTAINS EROSION & SEDIMENT CONTROL MEASURES FOR MULTIPLE PHASES OF CONSTSRUCTION. 2.SEE DWG E000 FOR SEQUENCE OF CONSTRUCTON NOTES. 3.SEE DWGS E001-E002 FOR OVERALL PHASING PLANS THAT INCLUDE PHASING FOR WATER HANDLING, DREDGING, AND EARTHWORK. 4.SEE DWGS E201-E203 FOR SEDIMENT & EROSION CONTROL DETAILS. PHASE 1A WESTERN LAKE PATH IMPROVEMENTS LOCH DORNIE DRAWN DOWN APROXIMATELY 8 FEET LIMITS OF DISTURBANCE, TYP SILT FENCE, TYP LIMITS OF DISTURBANCE, TYP SILT FENCE, TYP LOCH DORNIE DRAWN DOWN APROXIMATELY 8 FEET PLOT DATE: 8/14/2019 6:38 PM BY: SKANEFile: O:\32453-ATL\32453-002\CAD_BIM\ESC\E005 Saved by JMCSWAIN Save date: 7/3/2019 4:54 PM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 AUGUST 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. CHECKED BY: DRAWN BY: DESIGNED BY: LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 LANDSCAPE ARCHITECT: SUPPORTING ENGINEER: PAV E D S U R F A C E 6" MI N 2"-3" C L E A N WAS H E D S T O N E 12' MI N FILT E R F A B RI C *OR AS SHOWN ON PLAN* MAINTENANCE REQUIREMENTS: 1.MAINTAIN GRAVEL PAD IN A CONDITION TO PREVENT MUD OR SEDIMENT FORM LEAVING THE CONSTRUCTION SITE. PERIODIC TOPDRESSING WITH 2-INCH CLEAN, WASHED STONE IF NECESSARY. 2.INSPECT WEEKLY AND AFTER EACH RAINFALL PRODUCING 1 2 INCH OR MORE OF RAIN FOR ACCUMULATED SEDIMENT. REMOVE ANY ACCUMULATED SEDIMENT AS NECESSARY. 3.IMMEDIATELY REMOVE MATERIALS, SEDIMENT, AND/OR DEBRIS THAT HAS BEEN TRACKED ONTO ROADWAYS. 0257701R TEMPORARY GRAVEL CONSTRUCTION ENTRANCE / EXIT 50' M I N * POST-TO-POST 10' MAX SPACING ORANGE FENCING FABRIC EXISTING TREE GRADE EXISTING 2'4'METAL "T " POST 0227033R NOTES: 1.PLACE CONTINUOUS RUN OF FENCE MATERIAL ON BOTH SIDES OF IMMEDIATE WORK ZONE IN WOODED AREAS AS SHOWN ON THE PLANS. DO NOT ATTACH FENCE MATERIAL TO TREES. 2.TREE PROTECTION FENCING FABRIC TO BE PLACED AT THE DRIP LINE OF THE TREES THAT ARE TO BE PROTECTED. 3.FENCE SHALL BE PRE-CONSTRUCTED ORANGE BARRIER FENCE MEETING THE FOLLOWING REQUIREMENTS: 1. CONSTRUCTED OF HIGH STRENGTH POLYMER FABRIC 2. CONTAIN AN ULTRAVIOLET STABILIZER OR INHIBITOR 3. MESH OPENING: 1 1 2 " X 1 1 2" (MIN) 3" X 3" (MAX) 4. TENSILE STRENGTH: 180 LBS/FT (MIN) 5. 4' X 100' ROLL WEIGHT: 18 LBS (MIN) 4.SECURELY ATTACH A WARNING SIGN AT EACH END OF LINEAR FENCING AND 5O' ON CENTER THEREAFTER. 5.WARNING SIGNS TO BE MADE OF DURABLE, WEATHERPROOF MATERIAL. 6.LETTERS TO BE 3" HIGH MINIMUM AND CLEARLY, LEGIBLE, AND SPACED AS SHOWN. 7.MAINTAIN TREE PROTECTION / SAFETY FENCING THROUGHOUT DURATION OF PROJECT MAINTENANCE REQUIREMENTS: 1.INSPECT WEEKLY AND AFTER EACH RAINFALL PRODUCING 1/2 INCH OR MORE OF RAIN. 2.REPAIR OR RELACE DAMAGED FENCING IMMEDIATELY. 3.REPLACE ANY DAMAGED SIGNAGE IMMEDIATELY AS NEEDED. TREE PROTECTION / SAFETY BARRIER FENCE WARNING SIGN DETAIL 40"18"NO TRESPASSING TREE PROTECTION AREA PROHIBIDO ENTRAR ZONA PROTECTORA PARA LOS ARBOLES 3" 0227000R STEEL POST 3'-0" MINFILTER FABRIC3'-0" MINGRADE LINELINE WIRESBOTTOM STRAND TOP STRAND STAY WIRES MIN 8"MIN2'-0"MIN8"2'-2" MIN8'-0" MAX GALV WIRE FABRIC AND FILTER FABRIC. BURY TOE OF FILTER FABRIC A MIN OF 8" ELEVATION SILT FENCE SECTION SILT FENCE NOTES: 1.EXTRA STRENGTH FILTER FABRIC (AS APPROVED BY THE ENGINEER) WITH 6'-0" POST SPACING DOES NOT REQUIRE MESH SUPPORT FENCE. 2.FILTER FABRIC SHALL BE WIRED DIRECTLY TO THE POST. 3.WHERE DOUBLE SILT FENCE IS CALLED FOR ON THE DRAWINGS ADD SECOND SILT FENCE TO FACE OF FIRST SILT FENCE AND WIRE DIRECTLY TO POST. 4.WHERE TREE PROTECTION FENCE AND SILT FENCE ARE CO-LOCATED (TPF/SF), SILT FENCE MUST INCLUDE TREE CONSERVATION SIGNS. REFER TO DETAIL 0227033R MAINTENANCE REQUIREMENTS: 1.INSPECT WEEKLY AND AFTER EACH RAINFALL EVENT THAT PRODUCES 1/2 INCH OR MORE OF RAIN. REMOVE ANY ACCUMULATED SEDIMENT AND/OR WOODY DEBRIS. 2.FILTER FABRIC THAT HAS COLLAPSED, TORN, OR HAS IN ANY WAY HAS BECOME COMPROMISED SHALL BE REPAIRED OR REPLACED IMMEDIATELY. 3.REMOVE ANY SEDIMENT DEPOSITS AS NECESSARY TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAIN AND ALSO TO REDUCE PRESSURE ON THE FENCE. AVOID UNDERMINING THE FENCE DURING CLEANOUT. 4.REPLACE FILTER FABRIC THREE (3) MONTHS AFTER INITIAL INSTALLATION AND EVERY THREE (3) MONTHS THEREAFTER UNTIL CONSTRUCTION HAS COMPLETED AND CONTRIBUTING DRAINAGE AREA HAS BEEN PERMANENTLY STABILIZED. SILT FENCE 3' FILTER FABRIC ON GROUND STEEL FENCE POST WIRE FENCE HARDWARE CLOTH 1" DIAMETER WASHED STONE BURY 8" OF UPPER EDGE OF FILTER FABRIC IN TRENCH BURY WIRE FENCE AND HARDWARE CLOTH TOP OF SILT FENCE MUST BE AT LEAST 1' ABOVE THE TOP OF THE WASHED STONE SILT FENCE FRONT VIEW PROFILE VIEW STEEL FENCE POST SET MAX 2' APART MIN 18" INTO SOLID GROUND BURY WIRE FENCE, FILTER FABRIC, AND HARDWARE CLOTH IN TRENCH 4' MIN MAINTENANCE REQUIREMENTS: 1.INSPECT WEEKLY AND AFTER EACH RAINFALL EVENT THAT PRODUCES 1/2 INCH OR MORE OF RAIN. REMOVE SEDIMENT AND DEBRIS. TOPDRESSING WITH 1-INCH CLEAN, WASHED STONE AS NECESSARY. 2.REMOVE ACCUMULATED SEDIMENT. THE CONTRACTOR SHALL DISPOSE OF SEDIMENT OFF-SITE IN ACCORDANCE WITH ALL STATE AND LOCAL REGULATIONS. (DETAIL ADOPTED FROM THE TOWN OF HOLLY SPRINGS, NORTH CAROLINA - ENGINEERING DEPARTMENT). STABILIZED OUTLET FOR SILT FENCE 0227008 TIMBER MATTING DETAIL NTS 1.MINIMIZE SPACING BETWEEN PANELS OR PALLETS. CONNECT WITH QUICK LINKS OR OTHER HEAVY-DUTY CONNECTORS FOR EXTRA STABILITY. (SOME WOOD PALLETS ARE DESIGNED TO INTERCONNECT DURING INSTALLATION. 2.IF ADDITIONAL TRACTION IS NEEDED, USE EXPANDED METAL GRATING OR SIMILAR MATERIALS ON TOP OF THE WOOD PANELS OR PALLETS. 3.SIZE WOOD PANELS AND PALLETS TO MEET ANTICIPATED LOADS, SOIL STRENGTH, AND INSTALLATION EQUIPMENT. YOU MAY NEED ADDITIONAL SIZE ON VERY WEAK SOILS WITH LOW BEARING STRENGTH (E.G., MUCK OR PEAT) TO SPREAD WEIGHT OVER A LARGER AREA. 4.USE 3-INCH THICK BY 10-INCH WIDE BY 12-FEET LONG LUMBER FOR PLANKS. ALIGN PLANKS PARALLEL TO EACH OTHER. 5.NAIL 2 OR 3 BOARDS, EACH MEASURING 3 INCHES BY 10 INCHES BY 9 FEET, PERPENDICULAR TO THE PLANKS (USE RING-SHANK OR SPIRAL SPIKES). THESE ARE RUNNERS. 6.LEAVE A 1-INCH GAP BETWEEN THE PLANKS TO ALLOW WATER TO RUN THROUGH. USE AN AIR GUN OR COUNTERSUNK BOLTS TO REDUCE NAIL WITHDRAWAL DURING USE. 7.ADD EYE HOOKS AND LOOPED CABLES OR OTHER MATERIALS TO THE WOOD PANEL. THIS FACILITATES LIFTING AND INTERCONNECTION ONCE THEY ARE INSTALLED. 8.SMOOTH OUT HIGH SPOTS AND FILL RUTS. LEAVE ROOTS AND VEGETATION MATS IN PLACE TO ADD STABILITY. 9.COVER ENTIRE CROSSING AREA WITH NONWOVEN GEOTEXTILE. T. SCHUELER J. MCSWAIN J. MCSWAIN - - T. SCHUELER E201 ENTRANCE & PERIMETER CONTROL DETAILS CONSTRUCTION MAT DETAIL NTS PLOT DATE: 8/14/2019 6:39 PM BY: SKANEFile: O:\32453-ATL\32453-002\CAD_BIM\ESC\E006 Saved by JMCSWAIN Save date: 7/3/2019 4:54 PM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 AUGUST 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. CHECKED BY: DRAWN BY: DESIGNED BY: LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 LANDSCAPE ARCHITECT: SUPPORTING ENGINEER: STABLE VELOCITY DISSIPATOR CROSS SECTION OF SANDBAG DIKE PLAN VIEW P A SUMP-HOLE OR POOL (12" TO 18" DEEP 2' DIA.) INTAKE HOSE STREAM DIVERSION PUMPS P A DESCRIPTION: THE WORK SHOULD CONSIST OF INSTALLING A TEMPORARY PUMP AROUND AND SUPPORTING MEASURES TO DIVERT FLOW AROUND THE WORK AREA AND DEWATER WORK AREA. NOTES: 1.THE CONTRACTOR SHOULD STAY WITHIN THE LIMITS OF THE DISTURBANCE AS SHOWN ON THE PLANS AND MINIMIZE DISTURBANCE WITHIN THE WORK AREA WHENEVER POSSIBLE. 2.THE CONTRACTOR SHOULD ONLY BEGIN WORK IN AN AREA WHICH CAN BE COMPLETED BY THE END OF THE DAY. AT THE END OF EACH WORK DAY, THE WORK AREA MUST BE STABILIZED AND THE PUMP AROUND REMOVED. 3.SANDBAG DIKES SHOULD BE SITUATED AT THE ENDS OF THE WORK AREA AS SHOWN ON THE PLANS, AND CLEAN STREAM FLOW SHOULD BE PUMPED AROUND THE WORK AREA. THE PUMP SHOULD DISCHARGE ONTO A STABLE VELOCITY DISSIPATER MADE OF RIPRAP OR SANDBAGS. 4.WATER FROM THE WORK AREA SHOULD BE PUMPED TO A SEDIMENT FILTERING MEASURE SUCH AS A DEWATERING BASIN, SEDIMENT BAG, OR OTHER APPROVED SOURCE. THE MEASURE SHOULD BE LOCATED SUCH THAT THE WATER DRAINS DOWNSTREAM OF THE WORK AREA. 5.FOR STREAMWORK REPAIR PROJECTS LONGER THAN 4OO LINEAR FEET, MULTIPLE WORK AREAS SHALL BE ESTABLISHED IN SUCCESSION. ONCE AN AREA IS COMPLETED AND STABILIZED, THE CLEAN WATER DIKE SHOULD BE REMOVED. AFTER THE FIRST SEDIMENT FLUSH, A NEW CLEAN WATER DIKE WOULD BE ESTABLISHED FROM THE OLD SEDIMENT DIKE. FINALLY, UPON ESTABLISHMENT OF A NEW SEDIMENT DIKE BELOW THE OLD ONE, THE OLD SEDIMENT DIKE SHOULD BE REMOVED. 6.A PUMP AROUND MUST BE INSTALLED ON ANY TRIBUTARY OR STORM DRAIN OUTFALL WHICH CONTRIBUTES BASEFLOW TO THE WORK AREA. THIS SHOULD BE ACCOMPLISHED BY LOCATING A SANDBAG DIKE AT THE DOWNSTREAM END OF THE TRIBUTARY OR STORM DRAIN OUTFALL AND PUMPING THE STREAM FLOW AROUND THE WORK AREA. THIS WATER SHOULD DISCHARGE ONTO THE SAME VELOCITY DISSIPATER USED FOR THE MAIN STEM PUMP AROUND. 7.ALL SANDBAG DIVERSIONS TO BE BUILT TO EXISTING TOP OF BANK. PLAN VIEW SECTION A-A APPROVED DEWATERING DEVICE WORK AREA IMPERVIOUS SHEETING FLOW 2 YEAR WATER SURFACE ELVATION INTAKE HOSE DISTURBED AREA LENGTH NOT TO EXCEED THAT WHICH CAN BE STABILIZED IN ONE DAY DEWATERING PUMP DISCHARGE HOSE FLOW SANDBAG DIVERSION SEDIMENT DIKE CLEAN WATER DIKE PUMP AROUND DETAIL NTS CONSTRUCTION SPECIFICATIONS: 1.NO PLACEMENT OR REMOVAL OF CULVERTS SHALL OCCUR UNLESS ALL NECESSARY PERMIT APPROVALS HAVE BEEN ACQUIRED. 2.EXTEND THE CULVERT(S) A MINIMUM OF ONE FOOT BEYOND THE UPSTREAM AND DOWNSTREAM TOE OF THE AGGREGATE PLACED AROUND THE CULVERT. 3.PLACE NONWOVEN GEOTEXTILE ON THE STREAM BED AND STREAM BANKS PRIOR TO PLACEMENT OF THE CULVERT(S) AND AGGREAGE. COVER THE STREAM BED WITH THE GEOTEXTILE AND EXTEND IT A MINIMUM SIX INCHES AND A MAXIMUM OF ONE FOOT BEYOND THE END OF THE CULVERT AND BEDDING MATERIAL. USE NONWOVEN GEOTEXTILE AS SPECIFIED IN CONTRACT DOCUMENTS. 4.PLACE CULVERT(S) ON THE NATURAL STREAM BED GRADE TO MINIMIZE INTERFERENCE WITH FISH PASSAGE. 5.COVER THE CULVERT WITH A MINIMUM OF ONE FOOT OF WASHED AGGREGATE. FOR MULTIPLE CULVERTS, PROVIDE AT LEAST 12 INCHES OF COMPACTED AGGREGATE FILL BETWEEN CULVERTS. 6.STAIBLIZE ALL AREAS DISTURBED DURING CULVERT INSTALLATION WITHIN 24 HOURS OF THE DISTURBANCE IN ACCORDANCE WITH NC E&SC DESIGN MANUAL. 7.STABILIZE APPROACH TO CROSSING AND KEEP FREE OF EROSION. REPLACE DISPLACED STONE AND MAINTAIN HIGH FLOW AREAS. REMOVE DEBRIS TRAPPED BY CULVERT. REPLACE DAMAGED PIPES(S) . MAINTAIN AREAS ADJACENT TO CROSSING TO CONTINUOUSLY MEET REQUIREMENTS FOR ADEQUATE VEGETATIVE ESTABLISHMENT. 8.AFTER THE TEMPORARY CROSSING IS NO LONGER NEEDED, REMOVE IT WITHIN 14 CALENDAR DAYS. IF SUBJECT TO DESIGNATED USE RESTRICTIONS, REMOVE BY THE REQUIRED DATE OF THE CLOSURE PERIOD. PROTECT STREAM BANKS DURING CULVERT REMOVAL AND STABILIZE ALL AREAS WITH EROSION CONTROL MATTING. ACCOMPLISH REMOVAL OF THE CULVERT AND CLEAN UP OF THE AREA WITHOUT CONSTRUCTION EQUIPMENT WORKING IN THE WATERWAY CHANNEL. STORE ALL MATERIALS IN AN APPROVED STAGING AREA. TEMPORARY ACCESS CULVERT NTS SF SF SFSFSFSFSFSFSFSIDE VIEW TOP VIEWSFSFVARIABLE (10'-0" MINIMUM) TEMP SEDIMENT FILTER BAG 6" MIN 2'-0" MIN VARIES 10'-0" MIN VARIES WITH GROUND LINE SLOPE 2' MIN VARIES WITH GROUND LINE SLOPE TEMPORARY SEDIMENT FILTER BAG (14'-6" X 2'-0" X 13'-3") OPTIONAL LIFTING STRAPS 2' MIN 6" MIN EXIST GROUND LINE TEMP SILT FENCE (WITH BACKING)GEOTEXTILE LAYER POLYETHYLENE SHEETING USE #57 STONE TO LEVEL BAG FROM NATURAL GROUND LINE TEMP SILT FENCE (WITH BACKING) SEWN-IN CONNECTION SLEEVE FOR PUMP DISCHARGE HOSE TEMP SILT FENCE (WITH BACKING) COVER #57 STONE PAD WITH GEOTEXTILE (TYPE III EROSION CONTROL) POLYETHYLENE SHEETING (6 MIL MINIMUM) CONSTRUCTION SPECIFICATIONS: 1.CONTRACTOR SHALL EXERCISE CAUTION NOT TO BURST OR DAMAGE THE TEMPORARY SEDIMENT FILTER BAG WHEN PUMPING. 2.THE LENGTH AND WIDTH OF THE TEMPORARY SEDIMENT BAG SHOWN ON THIS DRAWING MAY VARY PER VENDOR SPECIFICATIONS. 3.TEMPORARY SEDIMENT FILTER BAGS SHALL BE EQUIPPED WITH A SEWN-IN SLEEVE OF SUFFICIENT SIZE TO ACCEPT A MINIMUM FOUR-INCH DIAMETER PUMP DISCHARGE HOSE. THE DISCHARGE HOSE SHOULD BE EXTENDED INTO THIS SLEEVE A MINIMUM OF SIX INCHES AND BE TIGHTLY SECURED WITH A HOSE CLAMP OR OTHER SUITABLE MEANS TO PREVENT LEAKAGE. HOSE CONNECTION THROUGH A SLIT IN THE BAG WILL NOT BE ACCEPTABLE. 4.THE PUMP DISCHARGE HOSE CONNECTION SLEEVE SHALL BE SECURELY TIED OFF DURING DISPOSAL OF THE TEMPORARY SEDIMENT FILTER BAG IN ORDER TO PREVENT LEAKAGE OF COLLECTED SEDIMENTS. 5.TEMPORARY SEDIMENT FILTER BAG SHALL BE REPLACED WHEN 6 INCHES OF SEDIMENT HAS ACCUMULATED OR IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. MAINTENANCE REQUIREMENTS: 1.INSPECT WEEKLY AND AFTER EACH RAINFALL EVENT PRODUCING 1 2 INCH OR MORE OF RAIN. ANY DAMAGE TO THE SEDIMENT FILTER BAG SHALL BE REPAIRED IMMEDIATELY. 2.TEMPORARY SEDIMENT FILTER BAG SHALL BE REPLACED WHEN 6 INCHES OF SEDIMENT HAS ACCUMULATED OR IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. 3.MONITOR SEDIMENT FILTER BAG REGULARLY FOR THE PRESENCE OF TURBID WATER BEING DISCHARGED. ANY TURBID WATER BEING DISCHARGED FROM THE BAG SHALL BE RESOLVED IMMEDIATELY. IF TEMPORARY BLOCKAGES ARE NOT FOUND, ASSUME THE BAG IS AT SEDIMENT CAPACITY AND REPLACE IMMEDIATELY. TEMPORARY SEDIMENT FILTER BAG NTSNTS TEMPORARY BARRIER DIVERSION PLAN SECTION SECURE PUMP LINE TO EXISTING GRADE, TYP TEMPORARY CLEAN WATER BY-PASS PUMPING STREAM BANK PLACE NON-WOVEN FILTER FABRIC UNDERNEATH ROCK ENERGY DISSIPATION STONE L3 L1 T L1 W1 SUNNY DAY BASE FLOW ROCK OUTLET PROTECTION (ROP) DETAIL NTS T. SCHUELER J. MCSWAIN J. MCSWAIN - - T. SCHUELER E202 ACCESS & FLOW DIVERSTION DETAILS PLOT DATE: 8/14/2019 6:39 PM BY: SKANEFile: O:\32453-ATL\32453-002\CAD_BIM\ESC\E007 Saved by JMCSWAIN Save date: 7/7/2019 2:52 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 AUGUST 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. CHECKED BY: DRAWN BY: DESIGNED BY: LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 LANDSCAPE ARCHITECT: SUPPORTING ENGINEER: T. SCHUELER J. MCSWAIN J. MCSWAIN - - T. SCHUELER E203 FINAL STABILIZATION & SEDIMENT CONTROL DETAILS THIS DRAWING REQUIRES SUPPORTING TECHNICAL DOCUMENTATION PRIOR TO USE AND MUST BE ADAPTED TO THE SPECIFIC SITE. GENERAL NOTES 1.COCONUT EROSION CONTROL BLANKET SHALL BE 'ROLANKA BIO-D 70' OR APPROVED EQUAL, ABLE TO WITHSTAND 12 FPS WATER VELOCITIES AND 4.5 PSF SHEAR STRESS. FABRIC EMBEDMENT 3.0 FT. 2.PREPARE SOIL BEFORE INSTALLING ROLLED EROSION CONTROL PRODUCTS (RECP), INCLUDING ANY NECESSARY APPLICATION OF LIME, FERTILIZER AND SEED. 3.BEGIN AT THE BOTTOM OF THE SLOPE, WORKING FROM DOWNSTREAM UP, AND ANCHOR FIBER MATTING IN A 12" DEEP INITIAL ANCHOR TRENCH. BACKFILL TRENCH AND TAMP EARTH FIRMLY. 4.OVERLAP EDGES OF ADJACENT PARALLEL ROLLS 12" AND ANCHOR AT 12" CENTERS WITH THE UPPER ROLL OVERLAPPING THE TOP OF THE LOWER ROLL. 5.WHEN FIBER MAT MUST BE SPLICED, PLACE END OVER END (SHINGLE STYLE IN DIRECTION OF FLOW) WITH 12" OVERLAP AND ANCHOR USING TWO STAGGERED ROWS OF STAKES AT 6" CENTERS. ADDITIONAL FASTENING MAY BE REQUIRED WHERE MATTING IS CUT TO INSTALL PLANTINGS. 6.LAY FIBER MAT LOOSELY AND ANCHOR SUFFICIENTLY TO MAINTAIN DIRECT CONTACT WITH THE SOIL - DO NOT STRETCH. 7.FOR SLOPES 2:1 AND STEEPER USE A MINIMUM OF (3) 18-INCH WOOD STAKES PER SQUARE YARD AND FOR SLOPES FLATTER THAN 2:1 USE A MINIMUM OF (2) 18-INCH WOOD STAKES PER SQUARE YARD. PROVIDE ADDITIONAL STAKING ALONG CHANNEL BOTTOM WHERE COIR MAT FORMS TOE OF SLOPE. 8.WOOD STAKES SHALL BE ANGLED SUCH THAT EXPOSED PORTION (2"-4") FACES UPSTREAM. 9.ANCHOR, FILL, AND COMPACT END OF FIBER MATTING IN 12"x6" TERMINAL ANCHOR TRENCH (MIRROR IMAGE OF INITIAL TRENCH). 10.ANCHORING DIMENSIONS TO BE REDUCED IN AREAS OF NATURAL RESOURCES TO BE PROTECTED. 11.EROSION CONTROL MATTING MAY BE EXTENDED UP STREAM BANK AS DIRECTED. STAKE FABRIC TO BOTTOM OF TRANSITION TRENCH, 1 STAKE PER 3 L.F. WOODEN STAKE WOVEN COIR FABRIC FILL KEY TRENCH WITH TOPSOIL AND COMPACT. EDGE OF FABRIC 4-INCHES MIN. FROM WOODEN STAKE PLAN VIEW FOLDING FABRIC AT BENDS FABRIC WRAP WOVEN COIR FABRIC 1'MINFILL KEY TRENCH WITH TOPSOIL AND COMPACT EDGE OF FABRIC 4-INCHES MIN. FROM WOODEN STAKE 1'MINTYPICAL DETAIL STAKE18" MINSAW A 2 X 4 DIAGONALLY TO PRODUCE 2 DEAD STOUT STAKES. TOP OF BANK FLOW TOE SLOPE PROTECTION TO BE PROVIDED AS IDENTIFIED ON DETAIL. UPSTREAM FABRIC OVERLAPS DOWNSTREAM FABRIC 1' (SEE OVERLAP DETAIL) UPSTREAM FABRIC DOWNSTREAM FABRIC 3.0' DOWNSTREAM FABRIC LAYER LAPS UNDER STAKE THROUGH BOTH FABRIC LAYERS STAKE THROUGH BOTTOM FABRIC LAYER UPSTREAM FABRIC LAYER LAPS OVER TOP UPSTREAM FABRIC OVERLAPS DOWNSTREAM FABRIC 1'1'MINSEE KEY TRENCH DETAIL ALL FABRIC FORMS WILL BE LAPPED IN AN UPSTREAM TO DOWNSTREAM DIRECTION. MAXIMUM ANGLE 15 DEGREES STAKES ON 3' CENTERS, TYP A A B B 1'MINPLAN VIEW KEY TRENCH DETAIL OVERLAP SECTION A OVERLAP SECTION B TOP OF BANK TOE OF SLOPE TRANSITION TRENCH DETAIL STAKE FABRIC TO BOTTOM OF TRANSITION TRENCH, 1 STAKE PER 3 L.F. WOODEN STAKE 1' FLOW FLOW 18" WOOD STAKE (EXPOSED PORTION TO FACE UPSTREAM) BANKFULL BASE FLOW TIE-IN MATTING (12" MIN) 12" * 1-FT MIN 6" MIN ** COIR FIBER MAT BACKFILL AND TRANSITION INTO STREAMBANK * ** PROPOSED SLOPE EXISTING GROUND TRIANGULAR WOOD STAKE STAKES THROUGH BOTTOM FABRIC LAYER STAKES THROUGH BOTH FABRIC LAYERS SEE TRANSITION TRENCH DETAIL TOE OF SLOPE KEY-IN VERTICAL EDGE AT UPSTREAM BOUNDARY LIMITS KEY-IN VERTICAL EDGE AT DOWNSTREAM BOUNDARY LIMITS COIR MAT TO OVERLAY STRAW, SEED AND 6 INCHES OF TOP SOIL COIR FIBER MATTING DETAIL NTS 3D GEOMAT (GM) DETAIL NTS NOTES: 1.PREPARE SOIL BEFORE INSTALLING 3D GEOMAT, INCLUDING ANY NECESSARY APPLICATION OF LIME, FERTILIZER AND SEED. 2.INSTALL 3D GEOMAT ABOVE AND BELOW WATERLINE FOLLOWING MANUFACTURER'S RECOMMENDATIONS. 3.WHEN USING MULTIPLE PANELS, OVERLAP EDGES A MINIMUM OF 12 INCHES; UPSLOPE OVER DOWNSLOPE AND UPSTREAM OVER DOWNSTREAM WHERE APPLICABLE. 4.EXTEND 3D GEOMAT TO COVER TRANSITIONAL RANGE WHERE SCOUR IS PREDICTED BASED ON TYPICAL WATER LEVEL FLUCTUATIONS AND WAVE LAP 5.PLACE STAPLES/ANCHORS IN APPROPRIATE PATTERN AND SPACING PER MANUFACTURER'S RECOMMENDATION. PERIMETER STAPLES CAN BE SHARED BETWEEN ADJACENT PANELS. 6.PLACE ONE STAPLE PER LINEAR FOOT ALONG THE TOP AND BOTTOM EDGES OF THE 3D GEOMAT. 7.BURY TOP AND BOTTOM EDGES OF 3D GEOMAT INTO A TRENCH A MINIMUM OF 12 INCHES DEEP. 3D GEOMAT WATERLINE 12" BOTTOM TRENCH 12" TOP TRENCH STAPLE/ANCHOR COBBLE TO BE PLACED IMMEDIATELY ABOVE AND BELOW WATERLINE; SEE ISLAND PERIMETER BERM DETAIL DWG C200 TURBIDITY CURTAIN DETAIL NTS 00000000X XXXX00000000000000000000000000000000 0000 00000000 000000000000000000000000000000000000000000000000000000 0 00000000000000000000000000000000000000000000000 000000000000000000000000000000000000000000000000000000000OOOOOOOOOOOOOOOOOOOOOO OOO O OO O O O O O X XXXXX XXASPHALTASPHA L TCREEKGREENTRAP TRAPTRAP12" CMP10" CPP28" CPP24" CPPTELPEDOHE SSS S SSSS CREEKAS PHA L T ROCK W A L LROCK WALLCONCRETESPILLWAYLINVILLE RIVERWEIR24" CMP(APPROXIMATE LOCATION)EX. WLEX.WLLODLODLODLODLODLO D LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLOD LODLODLODLOD LOD LOD LOD LODLOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODL O DLODLODLODLODLODLODLODLODLODL O D LO D LOD LOD L O D LODLODLODL O D LODLOD LODLOD LODLODLOD LOD LOD L O D L O D LOD LOD LODLODLODLOD LODL O D LODLODLODLODLO D L O D LO D LOD LO D LODLODLODLODLODLO D LO D LOD LODLOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LODLODLODLODLODLODL O D LOD LOD LOD LOD LOD LODLODLODLODLOD60 1" = 120' 120 0 120'PLOT DATE: 8/14/2019 6:40 PM BY: SKANEFile: O:\32453-ATL\32453-002\CAD_BIM\CIVIL\C100 Saved by SKANE Save date: 8/12/2019 2:56 PM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 AUGUST 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. CHECKED BY: DRAWN BY: DESIGNED BY: LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 LANDSCAPE ARCHITECT: SUPPORTING ENGINEER: EX COBBLE DEPOSITION EX. PEDESTRIAN BRIDGE, TYP EX ISLAND, TYP LOCH DORNIE NORMAL POOL ELEVATION = 3787.5 LI N V I L L E R I V E R HW Y 1 0 5 C L U B H O U S E D R . GR A S S Y C R E E K R D W O O D C H U C K R D IS L A N D D R EX ISLAND DRIVE BRIDGE EX PEDESTRIAN BRIDGE AND SANITARY PIPE CROSSING CLUBHOUS E D R PRINCIPAL SPILLWAY WEIR BRIDGE LINVILLE RIVEREX EDGE OF WATER WEST CHANNE L EA S T C H A N N E L CLUB HOUSE FAIRWAY 18 NOTES: 1.PLANS SHOW COMBINATION OF GIS, LIDAR, AND MAY 10, 2019 SURVEY DATA SCALE: 1" = 120' PLAN OFFICE BUILDING MAINTENANCE BUILDING CLIFTON PARK FAIRWAY 17 T. SCHUELER S. KANE J. MCSWAIN - - T. SCHUELER C100 EXISTING CONDITIONS & DEMO PLAN OVERALL A B C D E F W O O D C H U C K R D ISLAND D R G EX PEDESTRIAN BRIDGE AND SANITARY PIPE CROSSING 3860385538503845384038403835383038 2 03835 3 8 2 0 3 8 1 5 3830381038153815 3832 3810381538203830 3835 3840 XXXXXXXXBUILDING J BUILDING J CART PATHLINVILLE RIVERLINV ILLE R IVER CART PATHCART PATH FAIRWAY 17 2 0 " CM P 8 " D I P LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LODLODLODLODLODLODLODLODLODLODLODLODLODL O D LOD LOD LODLODLODLODLOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLINVILLE RIVERLODLODLODLOD LODLODLODNOTES: 1.EXISTING GIS CONTOURS USED FOR TOPOGRAPHY OUTSIDE OF SURVEY. 2.AERIAL IMAGERY WAS USED TO DETERMINE A PORTION OF THE GOLF CART PATH, GOLF CART BRIDGE, AND FAIRWAY BOUNDS. 15 1" = 30' 30 0 30'PLOT DATE: 8/14/2019 6:40 PM BY: SKANEFile: O:\32453-ATL\32453-002\CAD_BIM\CIVIL\C101 Saved by SKANE Save date: 8/12/2019 3:07 PM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 AUGUST 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. CHECKED BY: DRAWN BY: DESIGNED BY: LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 LANDSCAPE ARCHITECT: SUPPORTING ENGINEER: MATCH LINE - SEE DWG C102 SCALE: 1" = 30' PLAN SSMH TOP EL: 3822.56 T. SCHUELER S. KANE J. MCSWAIN - - T. SCHUELER C101 EXISTING CONDITIONS & DEMO PLAN AREA 1 1 2 4 3 5 6 7 7 NOTE: SURVEY FOR THIS AREA PENDING DEMO FENCE LI N V I L L E R I V E R SEE INSET 1 SCALE: 1"= 30' INSET 1 3788 3785 3786 37 8 8 37853790 3795 38003 8 1 5 3 8 2 0 38153810381038153820381538003795 3800381038153830383038353840384538503820 3815 381538203830 3835 3800 3795 3790 3805 3800 3795 3790 378538053 8 0 0 3 8 0 5 3 8 1 0 3810 3815 3 8 0 5 3 8 0 0 379037950000 0 0 0 0 00000000XXXXXXXXXXXXXX0 00000000000000 00 00000 W.E.: 3824.1 BUILDING H BUILDING H BUILDING C 10" CPP 18 " C P P 24" CM P 18" CPPSSSSSSSS8" TRUSS(A)SSSS8" TRUSSSSSSSSSS8" TRUSS4" PV C 4" PVC8" TRUSS8" TRUSS 4" PVC8" TRUSS8" TRUSS 8" TR U S SLINVILLE RIVERCART PATHCART PATHCART PATH I S L A N D D R I V E BUILDING C UPP E R L O C H D O R NI E WES T C H A N N EL UPPER LOCH DORN IEEAST CHANNEL GREEN 17 TEE 18 TEE 18 TEE 18 TEE 18 FAIRWAY 17 15 " C P P LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODL O D L O D LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLOD LODLODL O D LODLODLOD LOD LODL O D L O D L O D LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LO D 15 1" = 30' 30 0 30'PLOT DATE: 8/14/2019 6:41 PM BY: SKANEFile: O:\32453-ATL\32453-002\CAD_BIM\CIVIL\C102 Saved by JMCSWAIN Save date: 7/6/2019 10:55 PM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 AUGUST 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. CHECKED BY: DRAWN BY: DESIGNED BY: LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 LANDSCAPE ARCHITECT: SUPPORTING ENGINEER: MATCH LINE - SEE DWG C103 SCALE: 1" = 30' PLAN MATCH LINE -SEE DWG C104EX COBBLE DEPOSITIONLINVILLE RIVERDEMO PEDESTRIAN BRIDGE AND SANITARY PIPE CROSSING SEE DWG C400 FOR NEW SANITARY DESIGN SEE DWG B501-B504 FOR NEW BRIDGE DESIGN MATCH LINE - SEE DWG C101 SSMH TOP ELEV: 3811.33 8" DIP IN (SW) I.E.: 3808.21 4" HDPE IN (SE) I.E.: 3808.00 8" TRUSS IN (NE) I.E.: 3807.37 8" TRUSS OUT (NW) I.E: 3801.28 SSMH TOP EL: 3810.40 8" TRUSS IN (SE) I.E.: 3805.98 8" TRUSS IN (NW) I.E.: 3805.87 SSMH TOP ELEV: 3808.32 SSMH TOP ELEV: 3822.56 SSMH TOP ELEV: 3821.39 SSMH TOP ELEV: 3806.21 SSMH TOP ELEV: 3831.00 T. SCHUELER S. KANE J. MCSWAIN - - T. SCHUELER C102 EXISTING CONDITIONS & DEMO PLAN AREA 2 1 2 4 3 5 6 7 7 DEMO LANDSCAPE TIMBERS AND FENCING LIMITS OF EXISTING DRY STACK ROCK WALL 37833 7 8 2 3790 3795 3785 3783 378637833850384538403835383038253820380037953785 378537953790379537903795379537903800 3 8 0 0 3 7 9 5 3 7 9 0 38 0 0 3 7 9 5 3805 38003790379537903 7 9 0 3 7 9 5000 0 0 0 0 00000000OO XXX0 00000000000 00 00000 000W.E. 3787.9 W.E. 3787.9 BUILDING BUILDING BUILDING BUILDING C BUILDING C BUILDING B BUILDING A BUILDING A BUILDING E BUILDING E BUILDING D BUILDING D BUILDING D 30" C M P 24" CM P 18" CMP 18" CPP6" P V C ( B )SSSS12" PVC 12" TRUSS(E)SSSSSS SSSSSSSSSSSS24" CPPUPPER LOCH DORNIEWEST CHANNEL8" TRUSS(A) BUILDING C UPPER LOCH DORNIEEAST CHANNELTEE 18 FAIRWAY 18UPPER LOCH DORN IEEAST CHANNEL ISLAND DRIV E ISLAND D R I V E LODLODLODLODL O D LOD LODLOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLO D LOD LOD LODLOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LODLODLODLODLODLODLODLODLOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LODLODLODLODLODLODLOD LO D L O D 15 1" = 30' 30 0 30'PLOT DATE: 8/14/2019 6:42 PM BY: SKANEFile: O:\32453-ATL\32453-002\CAD_BIM\CIVIL\C103 Saved by SKANE Save date: 7/3/2019 1:33 PM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 AUGUST 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. CHECKED BY: DRAWN BY: DESIGNED BY: LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 LANDSCAPE ARCHITECT: SUPPORTING ENGINEER: MATCH LINE - SEE DWG C102 MATCH LINE - SEE DWG C104MATCH LINE - SEE DWG C105 SCALE: 1" = 30' PLAN EX ISLAND DRIVE BRIDGE EX EDGE OF WATER SSMH TOP ELEV: 3811.80 SSMH TOP ELEV: 3803.20 SSMH TOP ELEV: 3799.45 SSMH TOP ELEV: 3802.74 SSMH TOP ELEV: 3811.38 T. SCHUELER S. KANE J. MCSWAIN - - T. SCHUELER C103 EXISTING CONDITIONS & DEMO PLAN AREA 3 1 2 4 3 5 6 7 7 3785 3785 37903792 37 9 5 3 8 0 0 3 8 0 5 3 8 0 5 380038 3 038253 8 2 0 381 500000000000000000000000000000 0 0 0 0 0 0 0 0 0 00 00000 000000000000000000 000000000000000000000000000000000000000000000000000000000000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0000 0 0XXXXXXXXXBUILDING BUILDING24" CPP24" CPP24" CPPC A R T P A T H C A R T P A T H A S P H A L T FAIRWAY 18 FAIRWAY 18 LOCH DORNIE LODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LODLODLO D L O D L O D LO D LOD LO D L O D L O D L O D L O D L O D L O D L O D L O D L O D L O D L O D L O D LOD L O D L O D L O D LO D LOD LOD LO D LO D LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODL O D L O D L O D L O D L O D L O D L O D L O D L O D L O D 15 1" = 30' 30 0 30'PLOT DATE: 8/14/2019 6:42 PM BY: SKANEFile: O:\32453-ATL\32453-002\CAD_BIM\CIVIL\C104 Saved by JMCSWAIN Save date: 7/4/2019 7:37 PM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 AUGUST 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. CHECKED BY: DRAWN BY: DESIGNED BY: LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 LANDSCAPE ARCHITECT: SUPPORTING ENGINEER:MATCH LINE - SEE DWG C103MATCH LINE - SEE DWGS C105 & C106 SCALE: 1" = 30' PLAN MATCH LINE - SEE DWG C102 T. SCHUELER S. KANE J. MCSWAIN - - T. SCHUELER C104 EXISTING CONDITIONS & DEMO PLAN AREA 4 1 2 4 3 5 6 7 7 4" CPP INV: 3791.38 4" CPP INV: 3787.93 4" CPP TO BE EXTENDED SEE DWG C204 378337843790 3795 3782 3790378537923785378037903785 3785 379537900000 0000000 0000000XX X X BUILDING BUILDING BUILDING BUILDING 6" CMP12" CMP4" CPP12" CM P 3 6 " C M P 1 2 " T R U S S ( F ) S S S S 6" PVC ( I ) 6" PV C( H)SS1 2 " TRUSS ( J )SSSSSS6" P V C SS SS 4" CIPSSSSSSSSSSSSSS1 2 " TRUSS (P )6" PVCSSLOC H D O R NI E D RI V E BUILDING E U P P E R L O C H D O R N I E W E S T C H A N N E L LOCH DORNIE LOCH DORNIE LOCH DORNIELODL O D L O D L O D LODLODLOD LODLODLOD LOD LOD LOD LODLODLODLOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD 15 1" = 30' 30 0 30'PLOT DATE: 8/14/2019 6:43 PM BY: SKANEFile: O:\32453-ATL\32453-002\CAD_BIM\CIVIL\C105 Saved by JMCSWAIN Save date: 7/6/2019 11:15 PM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 AUGUST 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. CHECKED BY: DRAWN BY: DESIGNED BY: LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 LANDSCAPE ARCHITECT: SUPPORTING ENGINEER: MATCH LINE - SEE DWG C103 MATCH LINE - SEE DWG C106SCALE: 1" = 30' PLAN MATCH LINE - SEE DWG C107 MATCH LINE - SEE DWG C104 EX EDGE OF WATER PEDESTRIAN BRIDGE "F" DEMO TO BE COORDINATED WITH BRIDGE REPLACEMENT TO MAINTAIN SERVICE AND SUPPORT OF EXISTING SANITARY SEWER PIPE; FOR BRIDGE WORK, SEE DWG B401 - B404 DEMO PEDESTRIAN BRIDGE "D" DEMO PEDESTRIAN BRIDGE "E" SSMH TOP ELEV: 3808.08 SSMH TOP ELEV: 3800.89 SSMH TOP ELEV: 3796.01 6" PVC IN I.E.: 3793.97 6" TRUSS(G) OUT I.E.: 3793.89 SSMH TOP ELEV: 3798.25 SSMH TOP ELEV: 3795.52 T. SCHUELER S. KANE J. MCSWAIN - - T. SCHUELER C105 EXISTING CONDITIONS & DEMO PLAN AREA 5 1 2 4 3 5 6 7 7 ASPHALT DEMO REMOVE SANITARY LINE (MANHOLE TO MANHOLE); FOR SANITARY WORK, SEE DWG C400 37833790378537843 7 9 2 37 9 0 378 5 379237923785 3780 37803782 3785 3785 380538 1 5 3815380538003 7 9 5 3 7 9 03795 XXXXXXXXXBLDG BLDG BLDG BUILDING 10" CPP28" CPP24" CP P 1 8 " C P P 70" C P P A S P H A L T ASP H A L T ASPHALTLOCH DORNIE GREEN 18 FAIRWAY 18 LOCH DORNIE LOCH DORNIE LOCH DORNIE LO D LOD LOD LOD L O D L O D LO D LOD LODLODLODLODLODLODLODLODLODLODLOD LODLODLODLODLODL O D L O D LODLODLODLODLODLODLODLODLODLOD LO D LO D LOD LODLODLODLODLODLODLODLOD LODLODLODLODLODLODLODL O D L O D L O D LODLODLODPLOT DATE: 8/14/2019 6:44 PM BY: SKANEFile: O:\32453-ATL\32453-002\CAD_BIM\CIVIL\C106 Saved by JMCSWAIN Save date: 7/6/2019 6:25 PM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 AUGUST 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. CHECKED BY: DRAWN BY: DESIGNED BY: LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 LANDSCAPE ARCHITECT: SUPPORTING ENGINEER: MATCH LINE - SEE DWG C104 MATCH LINE - SEE DWG C105MATCH LINE - SEE DWG C107 SCALE: 1" = 30' PLAN 15 1" = 30' 30 0 30' LOCH DORNIE EXISTING ISLAND, TYP EX EDGE OF WATER DEMO PEDESTRIAN BRIDGE "D" DEMO PEDESTRIAN BRIDGE "E" DEMO PEDESTRIAN BRIDGE "C" DEMO PEDESTRIAN BRIDGE "B" DEMO PEDESTRIAN BRIDGE "A" EX ROCK WALL, TYP FLAG ISLAND PETE'S ISLAND T. SCHUELER S. KANE J. MCSWAIN - - T. SCHUELER C106 EXISTING CONDITIONS & DEMO PLAN AREA 6 1 2 4 3 5 6 7 7 THIS AREA NOT TO BE DISTURBED REMOVE AND SALVAGE FLAG POLE, LIGHTING AND ELECTRIC CONTROLS DEMO PATH, STORMWATER DRAINAGE SYSTEM, AND VEGETATION AROUND CLUBHOUSE THAT IS FLAGGED FOR REMOVAL 3795 3795379037953790BUILDING 36" CM P 24" CPP 24" CPP15" C M PSSSS SS SS 6" P V C 6" PVC12" TRUSS(S)SSSSSSSS6" PVCSS SS SS SS12" TRUSS(U)12" T R U S S ( T )12" TRUSS(R)12" TR U S S ( Q ) LOCH DORNIE EX. WL LODLODLODLODLODLOD L O D LOD LODLODLODLODLODLODLODLODLODLODLOD LOD LODLODLODLODLODLODLOD LOD LOD LO D LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD3810 3805 3800 3795 37753820 3815 3810 3805 BUILDING 24" CPP 24" CP P 6" PVC 12" TRU S S( V)SSSS12" TRUSS(W)SSSSSS12" TRUSS(X)SSSSSSSSSS12" TRUSS(U)WOODCHUCK ROAD CLUB H O U S E D RI V E LOCH DORNIE EX. WL OHEWOOD FENCE 24" CMP LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LODLODLODLODLOD LOD LOD LOD LOD LODLODLODLODLODPLOT DATE: 8/14/2019 6:44 PM BY: SKANEFile: O:\32453-ATL\32453-002\CAD_BIM\CIVIL\C107 Saved by AYOUNG Save date: 7/3/2019 3:47 PM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 AUGUST 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. CHECKED BY: DRAWN BY: DESIGNED BY: LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 LANDSCAPE ARCHITECT: SUPPORTING ENGINEER: MATCH LINE - SEE THIS SHEET MATCH LINE - SEE THIS SHEETMATCH LINE - SEE DWG C105 MATCH LINE -SEE DWG ####SCALE: 1" = 30' PLAN SCALE: 1" = 30' PLAN 15 1" = 30' 30 0 30' MATCH LINE - SEE DWG C106 EX EDGE OF WATER EX EDGE OF WATER SSMH TOP ELEV: 3798.84 SSMH TOP ELEV: 3798.49 SSMH TOP ELEV: 3794.35 SSMH TOP ELEV: 3792.97 SSMH TOP ELEV: 3793.89 SSMH TOP ELEV: 3794.33 SSMH TOP ELEV: 3795.20 EX GRASSED UTILITY ACCESS PATH EX GRASSED UTILITY ACCESS PATH T. SCHUELER S. KANE J. MCSWAIN - - T. SCHUELER C107 EXISTING CONDITIONS & DEMO PLAN AREA 7 1 2 4 3 5 6 7 7 00000000X XXXX00000000000000000000000000000000 0000 00000000 000000000000000000000000000000000000000000000000000000 000000000000000000000000000000000000000000000000 000000000000000000000000000000000000000000000000000000000OOOOOOOOOOOOOOOOOOOOOO O O O O O O O O O O O X XXXXX XX W.E. 3787.9W.E. 3787.9W.E.: 3824.1A SPH A L TCREEK SO C C E R F I E LD BASKETBA L L COUR T GREENTRAPTRAPTRAPTRAPTELPEDNGS CM DAM N:865903.95E:1157252.32EL:3795.64OHE SSS S SSSS CREEKROCK W A L LROCK WALLCONCRETESPILLWAYLINVILLE RIVERWEIR24" CMP(APPROXIMATE LOCATION)EX. WLEX.WLWOOD FENCELODLODLODLODLODLO D LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLOD LODLODLODLOD LOD LOD LOD LODLOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODL O DLODLODLODLODLODLODLODLODLODL O D LO D LOD LOD L O D LODLODLODL O D LODLOD LODLOD LODLODLOD LOD LOD L O D L O D LOD LOD LODLODLODLOD LODL O D LODLODLODLODLO D L O D LO D LOD LO D LODLODLODLODLODLO D LO D LOD LODLODLOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LODLODLODLODLODLODL O D LOD LOD LOD LOD LOD LODLODLODLODLODXXSCALE: 1" = 120' PLAN COBBLE DEPOSITION TO BE REMOVED AND REUSED FOR NEW ISLAND PROTECTION; FOREBAY POOL TO BE EXCAVATED LI N V I L L E R I V E R HW Y 1 0 5 C L U B H O U S E D R . GR A S S Y C R E E K R D WO O D C H U C K R D IS L A N D D R REMOVE ISLAND EX ISLAND DRIVE BRIDGE CLUBHOUS E D R PRINCIPAL SPILLWAY WEIR BRIDGE LINVILLE RIVERWEST CHANNE L EA S T C H A N N E L ISLAND DRIVE LAWN LOCH DORNIE NORMAL POOL ELEVATION = 3787.5 EX EDGE OF WATER 60 1" = 120' 120 0 120' NOTES: 1.PLANS SHOW COMBINATION OF GIS, LIDAR , AND MAY 10, 2019 SURVEY DATA CLUB HOUSE FAIRWAY 18 REMOVE ISLAND WESTERN SHORE PEDESTRIAN PATH LOCH DORNIE POINT LOCH DORNIE DREDGE FAIRWAY 18 FILL CLUBHOUSE / EVENT LAWN PLOT DATE: 8/14/2019 6:45 PM BY: SKANEFile: O:\32453-ATL\32453-002\CAD_BIM\CIVIL\C200 Saved by SKANE Save date: 8/12/2019 3:36 PM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 AUGUST 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. CHECKED BY: DRAWN BY: DESIGNED BY: LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 LANDSCAPE ARCHITECT: SUPPORTING ENGINEER: J-CLUSTER STREAM STABILIZATION AND BANK PROTECTION CLIFTON PARK BEACH AREA PARKING FAIRWAY 17 T. SCHUELER S. KANE J. MCSWAIN - - T. SCHUELER C200 GRADING & DREDGING PLAN OVERALL SMALL ISLAND LARGE ISLAND 38503845384038253835383038 3 538303820 3830 382538203860385538503845384038403835383038 2 0 383538 2 0 3 8 1 5 3830381038153815 3832 3810381538203830 3835 3840 XBUILDING J BUILDING J CART PATHLINVILLE RIVERLINV ILLE R IVER CART PATHCART PATH FAIRWAY 17 2 0 " CM P 8 " D IP XXXXXXXXXXX3814 3814 3816 3817 3818 3819 3820 3815 3816 3817 3818 3819 3820 3821 3822 382 43825 3821382238233810381538203825383038353815-0+001+00 2+003+00 4+00 5+000+005+004+003+002+001+00LINVILLE RIVER384015 1" = 30' 30 0 30'PLOT DATE: 8/14/2019 6:46 PM BY: SKANEFile: O:\32453-ATL\32453-002\CAD_BIM\CIVIL\C201 Saved by SKANE Save date: 8/12/2019 3:12 PM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 AUGUST 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. CHECKED BY: DRAWN BY: DESIGNED BY: LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 LANDSCAPE ARCHITECT: SUPPORTING ENGINEER: MATCH LINE - SEE DWG C202 SCALE: 1" = 30' PLAN NOTES: 1.EXISTING GIS CONTOURS USED FOR TOPOGRAPHY OUTSIDE OF SURVEY. 2.AERIAL IMAGERY WAS USED TO DETERMINE A PORTION OF THE GOLF CART PATH, GOLF CART BRIDGE, AND FAIRWAY BOUNDS. 3.BUILDER HARVEST AREA (TO BE DEFINED AT NEXT DESIGN STAGE). T. SCHUELER S. KANE J. MCSWAIN - - T. SCHUELER C201 GRADING & DREDGING PLAN AREA 1 1 2 4 3 5 6 7 7 GCS1 POTENTIAL BOULDER HARVEST AREA; SEE NOTE 3 IRW #2 (0.5:1)IRW #1 (1:1) FOR IMBRICATED ROCK WALL (IRW) DESIGN INFORMATION SEE DWG C300 FOR GRADE CONTROL SILL (GCS) DESIGN INFORMATION SEE DWG C300 GCS2 GCS3 GCS 4 300 LF SPLIT-RAIL FENCE REPLACEMENT; SEE DETAIL DWG C301 LINVILLE RIVER STATIONING 170 LF NEW SPLIT-RAIL FENCE; SEE DETAIL DWG C301 SEE INSET 1 SCALE: 1"= 30' INSET 1 3788 3785 3786 37 8 8 37853790 3795 38003 8 1 5 3 8 2 0 38153810381038153820381538003795 3800381038153830383038353840384538503820 3815 381538203830 3835 3800 3795 3790 3805 3800 3795 3790 378538053 8 0 0 3 8 0 5 3 8 1 0 3810 3815 3 8 0 5 3 8 0 0 379037950000 0 0 0 0 00000000XXXXXXXXXXXXX0 00000000000000 00 00000 W.E.: 3824.1 BUILDING H BUILDING H BUILDING C 10" CPP 18 " C P P 24" CM P 18" CPPSSSSSSSS8" TRUSS(A)SSSS8" TRUSSSSSSSSSS8" TRUSS4" PV C 4" PVC8" TRUSS8" TRUSS 4" PVC8" TRUSS8" TRUSS 8" TR U S SLINVILLE RIVERCART PATHCART PATHCART PATH I S L A N D D R I V E BUILDING C UPP E R L O C H D O R NI E WES T C H A N N EL UPPER LOCH DORN IEEAST CHANNEL GREEN 17 TEE 18 TEE 18 TEE 18 TEE 18 FAIRWAY 17 15 " C P P LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODL O D L O D LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLOD LODLODL O D LODLODLOD LOD LODL O D L O D L O D LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LO DXXX378137833781378337873787378738113808 6+00 7+00 8+009+00 10+00 11+00 50+00 51+00 52+00 1 0+ 0 050+006+007+008+009+0011+0051+0052+0015 1" = 30' 30 0 30'PLOT DATE: 8/14/2019 6:47 PM BY: SKANEFile: O:\32453-ATL\32453-002\CAD_BIM\CIVIL\C202 Saved by JMCSWAIN Save date: 7/8/2019 9:12 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 AUGUST 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. CHECKED BY: DRAWN BY: DESIGNED BY: LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 LANDSCAPE ARCHITECT: SUPPORTING ENGINEER: MATCH LINE - SEE DWG C203 SCALE: 1" = 30' PLAN MATCH LINE -SEE DWG C204COBBLE DEPOSITION TO BE REMOVED AND REUSED FOR NEW ISLAND PROTECTION; FOREBAY POOL TO BE EXCAVATED DREDGE BOTH UPPER LOCH DORNIE CHANNELS (EAST AND WEST) SSMH TOP ELEV: 3811.33 8" DIP IN (SW) I.E.: 3808.21 4" HDPE IN (SE) I.E.: 3808.00 8" TRUSS IN (NE) I.E.: 3807.37 8" TRUSS OUT (NW) I.E: 3801.28 SSMH TOP ELEV: 3808.32 SSMH TOP ELEV: 3822.56 SSMH TOP ELEV: 3821.39 SSMH TOP ELEV: 3806.21 SSMH TOP ELEV: 3831.00 MATCH LINE - SEE DWG C201 NOTES: 1.CONTRACTOR TO AVOID ALL EXISTING STRUCTURES INCLUDING DOCKS AND DECKING. 2.SEE DWGS E002-E203 FOR DETAILS AND PHASING FOR WATER HANDLING, DREDGING, AND EARTHWORK. T. SCHUELER S. KANE J. MCSWAIN - - T. SCHUELER C202 GRADING & DREDGING PLAN AREA 2 1 2 4 3 5 6 7 7 FOR PROPOSED SANITARY SEWER WORK, SEE DWG C400 IRW #3 (0.8:1) FOR IMBRICATED ROCK WALL (IRW) DESIGN INFORMATION SEE DWG C300 FOR PROPOSED BRIDGE 5 WORK, SEE DWG B501 - B504 LINVILLE RIVER STATIONING 37833 7 8 2 3790 3795 3785 3783 378637833850384538403835383038253820380037953785 378537953790379537903795379537903800 3 8 0 0 3 7 9 5 3 7 9 0 38 0 0 3 7 9 5 3805 38003790379537903 7 9 0 3 7 9 5000 0 0 0 0 00000000OO XXX0 00000000000 00 00000 000W.E. 3787.9 W.E. 3787.9 BUILDING BUILDING BUILDING BUILDING C BUILDING C BUILDING B BUILDING A BUILDING A BUILDING E BUILDING E BUILDING D BUILDING D BUILDING D 30" C M P 24" CM P 18" CMP 18" CPP6" P V C ( B )SSSS12" PVC 12" TRUSS(E)SSSSSS SSSSSSSSSSSS24" CPPUPPER LOCH DORNIEWEST CHANNEL8" TRUSS(A) BUILDING C UPPER LOCH DORNIEEAST CHANNELTEE 18 FAIRWAY 18UPPER LOCH DORN IEEAST CHANNEL ISLAND DRIV E ISLAND D R I V E LODLODLODLODL O D LOD LODLOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLO D LOD LOD LODLOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LODLODLODLODLODLODLODLODLOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LODLODLODLODLODLODLOD LO D L O D 3 7 8 2 378237813783378337873784378337853 7 8 7 3 7 8 5 3785378737833 7 9 03791 378437823 78 23783378337833 7 8 3 3790379137893785378511+00 12+00 13+00 14+00 15+00 16+0052+0053+0054+00 55+00 56+00 57+0057+0011+0052+0056+0055+0054+0053+0012+0013+0014+0015+0016+00NOTES: 1.CONTRACTOR TO AVOID ALL EXISTING STRUCTURES INCLUDING DOCKS AND DECKING. 2.SEE DWGS E002-E203 FOR DETAILS AND PHASING FOR WATER HANDLING, DREDGING, AND EARTHWORK. 15 1" = 30' 30 0 30'PLOT DATE: 8/14/2019 6:48 PM BY: SKANEFile: O:\32453-ATL\32453-002\CAD_BIM\CIVIL\C203 Saved by SKANE Save date: 8/12/2019 3:18 PM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 AUGUST 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. CHECKED BY: DRAWN BY: DESIGNED BY: LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 LANDSCAPE ARCHITECT: SUPPORTING ENGINEER: MATCH LINE - SEE DWG C202 MATCH LINE - SEE DWG C204MATCH LINE - SEE DWG C205 SCALE: 1" = 30' PLAN EX. ISLAND DRIVE BRIDGE DREDGE BOTH UPPER LOCH DORNIE CHANNELS (EAST AND WEST) SSMH TOP ELEV: 3811.80 SSMH TOP ELEV: 3803.20 SSMH TOP ELEV: 3802.74 SSMH TOP ELEV: 3811.38 T. SCHUELER S. KANE J. MCSWAIN - - T. SCHUELER C203 GRADING & DREDGING PLAN AREA 3 1 2 4 3 5 6 7 7 LINVILLE RIVER STATIONING PROPOSED FILL WITH DREDGE MATERIAL PROPOSED COBBLE SWALE 3785 3785 37903792 37 9 5 3 8 0 0 3 8 0 5 3 8 0 5 380038 3 038253 8 2 0 381 500000000000000000000000000000 0 0 0 0 0 0 0 0 0 0 0 00000 000000000000000000 000000000000000000000000000000000000000000000000000000000000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0000 0 0XXXXXXXXXBUILDING BUILDING24" CPP24" CPP24" CPPC A R T P A T H C A R T P A T H A S P H A L T FAIRWAY 18 FAIRWAY 18 LOCH DORNIE LODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LODLODLO D L O D L O D LO D LOD LO D L O D L O D L O D L O D L O D L O D L O D L O D L O D L O D L O D L O D LOD L O D L O D L O D LO D LOD LOD LO D LO D LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODL O D L O D L O D L O D L O D L O D L O D L O D L O D L O D 37823781 3 7 9 3 3 7 9 1 3790 3787 3783 3785 3 7 9 0 15 1" = 30' 30 0 30'PLOT DATE: 8/14/2019 6:49 PM BY: SKANEFile: O:\32453-ATL\32453-002\CAD_BIM\CIVIL\C204 Saved by JMCSWAIN Save date: 7/7/2019 12:14 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 AUGUST 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. CHECKED BY: DRAWN BY: DESIGNED BY: LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 LANDSCAPE ARCHITECT: SUPPORTING ENGINEER:MATCH LINE - SEE DWG C103MATCH LINE - SEE DWGS C205 & C206 SCALE: 1" = 30' PLAN MATCH LINE - SEE DWG C202 T. SCHUELER S. KANE J. MCSWAIN - - T. SCHUELER C204 GRADING & DREDGING PLAN AREA 4 1 2 4 3 5 6 7 7 4" CPP INV: 3791.38 4" CPP INV: 3788 FAIRWAY 18 PROPOSED FILL AND SHORELINE STABILIZATION CONNECT 4" CPP TO EXISTING DRAIN PIPE AND EXTEND NEW LENGTH TO WATERS EDGE 105 LF 4" CPP 378337843790 3795 3782 3790378537923785378037903785 3785 379537900000 0000000 0000000XX X X BUILDING BUILDING BUILDING BUILDING 6" CMP12" CMP4" CPP3 6 " C M P 1 2 " T R U S S ( F ) S S S S 6" PVC ( I ) 6" PV C( H)SS1 2 " TRUSS ( J )SSSSSS6" P V C SS SS 4" CIPSSSSSSSSSSSSSS1 2 " TRUSS (P )6" PVCSSLOC H D O R NI E D RI V E BUILDING E U P P E R L O C H D O R N I E W E S T C H A N N E L LOCH DORNIE LOCH DORNIE LOCH DORNIELODL O D L O D L O D LODLOD LOD LODLODLOD LOD LOD LOD LODLODLODLOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD3782 3 7 8 2 3781 3780 3780 3779377937803 780 3779 3783 3781 3781 37823 7 8 1 3781 3 7 9 1 3790 3785 3787 3783 3 7 8 5 3 7 8 7 3 7 9 03791 3 7 8 5 3 7 8 7 37893 7 8 4 37843 7 8 4 3 7 8 4 3 7 8 0 3782 37823 7 8 4 37933793379238003802379 6 3791379337933793 3790 379037943 7 9 03790378217+00 18+00 58+00 59+00 59+50 5 8 + 0 0 59 + 0 0 59 + 5 0 1 7 + 0 0 18 + 0 0 15 1" = 30' 30 0 30'PLOT DATE: 8/14/2019 6:50 PM BY: SKANEFile: O:\32453-ATL\32453-002\CAD_BIM\CIVIL\C205 Saved by JMCSWAIN Save date: 7/7/2019 12:53 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 AUGUST 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. CHECKED BY: DRAWN BY: DESIGNED BY: LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 LANDSCAPE ARCHITECT: SUPPORTING ENGINEER: MATCH LINE - SEE DWG C203 MATCH LINE -SEE DWG C206SCALE: 1" = 30' PLAN MATCH LINE - SEE DWG C207 MATCH LINE - SEE DWG C204 PROPOSED LARGE ISLAND WITH DREDGE MATERIAL AS FILL REMOVE ISLAND PROPOSED ISLAND DRIVE LAWN FILL AND SHORELINE STABILIZATION SSMH TOP ELEV: 3808.08 SSMH TOP ELEV: 3800.89 SSMH TOP ELEV: 3796.01 6" PVC IN I.E.: 3793.97 6" TRUSS(G) OUT I.E.: 3793.89 SSMH TOP ELEV: 3798.25 SSMH TOP ELEV: 3795.52 NOTES: 1.CONTRACTOR TO AVOID ALL EXISTING STRUCTURES INCLUDING DOCKS AND DECKING. 2.SEE DWGS E002-E203 FOR DETAILS AND PHASING FOR WATER HANDLING, DREDGING, AND EARTHWORK. BRIDGE ABUTMENT LOCATION, TYP PROPOSED WEST SHORE GRADING T. SCHUELER S. KANE J. MCSWAIN - - T. SCHUELER C205 GRADING & DREDGING PLAN AREA 5 1 2 4 3 5 6 7 7 FOR PROPOSED BRIDGE 4 WORK, SEE DWG B401 - B404 FOR PROPOSED BRIDGE 3 WORK, SEE DWG B301 - B307 FOR PROPOSED SANITARY SEWER WORK, SEE DWG C400 4" CPP INV: 3788 PROPOSED PATH IMPROVEMENTS LINVILLE RIVER STATIONING 37833790378537843 7 9 2 37 9 0 378 5 379237923785 3780 37803782 3785 3785 380538 1 5 3815380538003 7 9 5 3 7 9 03795 XXXXXXXXXBLDG BLDG BLDG BUILDING 1 8 " C P P 70" C P P A S P H A L T ASP H A L T LOCH DORNIE GREEN 18 FAIRWAY 18 LOCH DORNIE LOCH DORNIE LOCH DORNIE LO D LOD LOD LOD LO D L O D LO D LOD LODLODLODLODLODLODLODLODLODLODLOD LODLODLODLODLODL O D L O D LODLODLODLODLODLODLODLODLODLOD LO D LO D LOD LODLODLODLODLODLODLODLOD LODLODLODLODLODLODLODL O D L O D L O D LODLODLOD780 3780 3 7 7 9 3779377937803780 377937823 7 8 1 3781 3 7 9 1 3790 3785 3787 3783 3 78 3 3 7 8 0 37 8 0 3782 37823 7 7 53793379037943 7 9 037903782 3 7 9 3 3 7 9 3 3 7 8 1 3 7 8 1 3790 3 7 9 0 3 7 8 8 3 7 9 0 3 7 7 7 3795 3796 3797 3 800 3802 17+00 18+00 19+00 20+00 21+00 22+00 23+00 24+00 24+0624+001 7 + 0 0 18 + 0 0 1 9 + 0 0 2 0 + 0 0 2 1 + 0 0 2 2+ 0 0 23+00PLOT DATE: 8/14/2019 6:51 PM BY: SKANEFile: O:\32453-ATL\32453-002\CAD_BIM\CIVIL\C206 Saved by JMCSWAIN Save date: 7/7/2019 12:53 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 AUGUST 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. CHECKED BY: DRAWN BY: DESIGNED BY: LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 LANDSCAPE ARCHITECT: SUPPORTING ENGINEER: MATCH LINE - SEE DWG C204 MATCH LINE - SEE DWGS C205 & C206 MATCH LINE - SEE DWG C207 SCALE: 1" = 30' PLAN 15 1" = 30' 30 0 30' CLUBHOUSE PROPOSED LARGE ISLAND WITH DREDGE MATERIAL AS FILL BRIDGE ABUTMENT LOCATION, TYP EX ROCK WALL, TYP ROCK WALL RETAINING WALL, SEE DETAIL DWG W100 - W101 ISLAND REVETMENT, TYP SEE DETAIL DWG C300 NOTES: 1.CONTRACTOR TO AVOID ALL EXISTING STRUCTURES INCLUDING DOCKS AND DECKING. 2.SEE DWGS E002-E203 FOR DETAILS AND PHASING FOR WATER HANDLING, DREDGING, AND EARTHWORK. T. SCHUELER S. KANE J. MCSWAIN - - T. SCHUELER C206 GRADING & DREDGING PLAN AREA 6 1 2 4 3 5 6 7 7 LARGE ISLAND SMALL ISLAND FOR PROPOSED BRIDGE 1 WORK, SEE DWG B101 - B104 FOR PROPOSED BRIDGE 2 WORK, SEE DWG B201 - B204 FOR PROPOSED BRIDGE 3 WORK, SEE DWG B301 - B307 PROPOSED EVENT LAWN GRADING 4" CPP INV: 3788 REMOVE ISLAND REMOVE ISLAND LINVILLE RIVER STATIONING 3795 3795379037953790BUILDING 36" CM P 24" CPP 24" CPP15" C M PSSSS SS SS 6" P V C 6" PVC12" TRUSS(S)SSSSSSSS6" PVCSS SS SS SS12" TRUSS(U)12" T R U S S ( T )12" TRUSS(R)12" TR U S S ( Q ) LOCH DORNIE EX. WL LODLODLODLODLODLOD L O D LOD LODLODLODLODLODLODLODLODLODLODLOD LOD LODLODLODLODLODLODLOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD3 7 8 7 3 7 8 5 3785378 9 37 8 8 3 78 5 3 784 3790 379 3 379037873810 3805 3800 3795 37753820 3815 3810 3805 BUILDING 24" CPP24" CP P 6" PVC 12" TRU S S( V)SSSS12" TRUSS(W)SSSSSS12" TRUSS(X)SSSSSSSSSS12" TRUSS(U)WOODCHUCK ROAD CLUB H O U S E D RI V E LOCH DORNIE EX. WL OHEWOOD FENCE 24" CMP LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LODLODLODLODLOD LOD LOD LOD LOD LODLODLODLODLOD37903793PLOT DATE: 8/14/2019 6:52 PM BY: SKANEFile: O:\32453-ATL\32453-002\CAD_BIM\CIVIL\C207 Saved by SKANE Save date: 8/12/2019 3:20 PM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 AUGUST 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. CHECKED BY: DRAWN BY: DESIGNED BY: LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 LANDSCAPE ARCHITECT: SUPPORTING ENGINEER: MATCH LINE - SEE THIS SHEET MATCH LINE - SEE THIS SHEETMATCH LINE - SEE DWG C205 SCALE: 1" = 30' PLAN SCALE: 1" = 30' PLAN 15 1" = 30' 30 0 30' MATCH LINE - SEE DWG C206 SSMH TOP ELEV: 3798.84 SSMH TOP ELEV: 3798.49 SSMH TOP ELEV: 3794.35 SSMH TOP ELEV: 3792.97 SSMH TOP ELEV: 3793.89 SSMH TOP ELEV: 3794.33 SSMH TOP ELEV: 3795.20 PROPOSED PEDESTRIAN PATH GRADING PROPOSED PEDESTRIAN PATH GRADING T. SCHUELER S. KANE J. MCSWAIN - - T. SCHUELER C207 GRADING & DREDGING PLAN AREA 7 1 2 4 3 5 6 7 7 PROPOSED PATH PROPOSED PATH PROPOSED FILL WITH DREDGE MATERIAL PROPOSED FILL WITH DREDGE MATERIAL PROPOSED FILL WITH DREDGE MATERIAL 3787.5 3787.5 3787.5 X XXXXOOOOOOOOOOOOOOOOOOOOOOOO O O O O O O O O O X XXXXX XXASPHALTA SPH A L TCREEKGREENTRAP TRAPTRAPTELPEDNGS CM DAM N:865903.95E:1157252.32EL:3795.64OHE SSS S SSSS CREEKROCK W A L LROCK WALLCONCRETESPILLWAYLINVILLE RIVERWEIR24" CMP(APPROXIMATE LOCATION)EX. WLEX.WLLODLODLODLODLODLO D LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLOD LODLODLODLOD LOD LOD LOD LODLOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODL O DLODLODLODLODLODLODLODLODLODL O D LO D LOD LOD L O D LODLODLODL O D LODLOD LODLOD LODLODLOD LOD LOD L O D L O D LOD LOD LODLODLODLOD LODL O D LODLODLODLODLO D L O D LO D LOD LO D LODLODLODLODLODLO D LO D LOD LODLOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LODLODLODLODLODLODL O D LOD LOD LOD LOD LOD LODLODLODLODLODXX24+ 0 0 0+005+0 0 10+00 15 + 0 0 20+00 24+ 0 0 50+0055+ 0 0 59+50 3+133+804+413+133+804+418+398+399+409+40 11+4811+4812+8612+8615+1315+1318+0319+6820+4921+7723+8918+0320+4921+ 7 7 19+6823+8951+76 51+7653+1353+1354+9154+9156+9256+9258+2758+27L INV I L L ERIVER SCALE: 1" = 120' PLAN 120'0120 1" = 120' 60 PLOT DATE: 8/14/2019 6:53 PM BY: SKANEFile: O:\32453-ATL\32453-002\CAD_BIM\CIVIL\C220 Saved by SKANE Save date: 8/12/2019 3:38 PM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 AUGUST 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. CHECKED BY: DRAWN BY: DESIGNED BY: LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 LANDSCAPE ARCHITECT: SUPPORTING ENGINEER: T. SCHUELER S. KANE J. MCSWAIN - - T. SCHUELER C220 GRADING & DREDGING PROFILES OVERALL LOCH DORNIE NORMAL POOL ELEVATION = 3787.5 HW Y 1 0 5 C L U B H O U S E D R . GR A S S Y C R E E K R D W O O D C H U C K R D IS L A N D D R CLUBHOUS E D R LINVILLE RIVERWESTCHANNEL EA S T CH A N N E L CLUB HOUSE FAIRWAY 18 CLIFTON PARK FAIRWAY 17 A A LARGE ISLAND SMALL ISLAND NOTES: 1.ALL PROFILES FACING DOWNSTREAM STA 4+41 3800 3805 3810 3815 3820 3825 3830 3835 3840 3845 3800 3805 3810 3815 3820 3825 3830 3835 3840 3845 -0+75 0+00 0+60 STA 3+80 3800 3805 3810 3815 3820 3825 3830 3835 3840 3845 3800 3805 3810 3815 3820 3825 3830 3835 3840 3845 -0+75 0+00 0+50 STA 3+13 3800 3805 3810 3815 3820 3825 3830 3835 3840 3845 3800 3805 3810 3815 3820 3825 3830 3835 3840 3845 -1+00 0+00 0+50 PROP GRADE PROP GRADE EX GRADE PROP GRADE XXFAIRWAY 17 X100-YR ELEV: 3820.0 100-YR ELEV: 3818.2 100-YR ELEV: 3816.9XXXXX BASEFLOW ELEV: BASEFLOW ELEV2:10.5:17:1 100:1 100:10.5:17:1 8:1 2.4:11:11:1LEFT J-CLUSTER RIGHT EX SIDEWALK BUILDING LIMITS, TYP BASEFLOW ELEV: 6' 6' 6' 2' IRW #2 IRW #1 2' THICK 3"-4" STONE 6' 6' 2' IRW #2 IRW #1 6' THICK IMBRICATED ROCK WALL; SEE ROCK SIZING CHART DWG C300 FOR BOULDER SIZE 2' THICK 3"-4" STONE FAIRWAY 17 LEFT FAIRWAY 17 LEFT J-CLUSTER RIGHT J-CLUSTER RIGHT APPROVED FILL APPROVED FILL 6' 6'1.5:13:10.5:16' 2' IRW #2 6' 6' THICK IMBRICATED ROCK WALL; SEE ROCK SIZING CHART DWG C300 FOR BOULDER SIZE 2' THICK 3"-4" STONE 2' THICK 3"-4" STONE IRW #1 PROP FENCE, TYP EX FENCE, TYP PROP FENCE EX GRADE PROP FENCE EX FENCE EX SIDEWALK PROP FENCE PROP FENCE EX GRADE EX FENCE, TYP EX GRADE ELEV: 3826.00 ELEV: 3816.91 ELEV: 3810.92 ELEV: 3808.71 ELEV: 3816.70 ELEV: 3830.00 6' THICK IMBRICATED ROCK WALL; SEE ROCK SIZING CHART DWG C300 FOR BOULDER SIZE 6' THICK IMBRICATED ROCK WALL; SEE ROCK SIZING CHART DWG C300 FOR BOULDER SIZE ELEV: 3824.22 ELEV: 3814.09 ELEV: 3808.19ELEV: 3814.00ELEV: 3826.00 ELEV: 3803.78 100:1 6' THICK IMBRICATED ROCK WALL; SEE ROCK SIZING CHART DWG C300 FOR BOULDER SIZE 6' THICK IMBRICATED ROCK WALL; SEE ROCK SIZING CHART DWG C300 FOR BOULDER SIZE ELEV: 3823.93 ELEV: 3818.57 ELEV: 3818.53 ELEV: 3812.67 ELEV: 3823.40 ELEV: 3801.21 STA 0+79 3815 3820 3825 3830 3835 3840 3815 3820 3825 3830 3835 3840 -0+50 0+00 0+50 FAIRWAY 17 LEFT FAIRWAY 17 RIGHT PIPE PROTECTION; SEE DETAIL DWG C301 PROP GRADE EX GRADE EX 8" DIP SAN1:160:1 1:13 . 5 : 1 7: 1 2:10.5:1IRW #2 IRW #4 NOTES: 1.ALL PROFILES FACING DOWNSTREAM H:- V:1" = 5'1" = 20' PROFILE 0 VERTICAL SCALE: 1" = 5' 05 5 HORIZONTAL SCALE: 1" = 20' 20 10 20'PLOT DATE: 8/14/2019 6:54 PM BY: SKANEFile: O:\32453-ATL\32453-002\CAD_BIM\CIVIL\C221 Saved by SKANE Save date: 8/13/2019 9:53 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 AUGUST 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. CHECKED BY: DRAWN BY: DESIGNED BY: LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 LANDSCAPE ARCHITECT: SUPPORTING ENGINEER: T. SCHUELER S. KANE J. MCSWAIN - - T. SCHUELER C221 GRADING & DREDGING PROFILES (J-CLUSTER BANK STABILIZATION) STA 15+13 3775 3780 3785 3790 3795 3800 3775 3780 3785 3790 3795 3800 -0+60 0+00 0+40 STA 12+86 3775 3780 3785 3790 3795 3800 3775 3780 3785 3790 3795 3800 -0+50 0+00 0+90 STA 11+48 3775 3780 3785 3790 3795 3800 3805 3810 3815 3775 3780 3785 3790 3795 3800 3805 3810 3815 -0+50 0+00 0+50 STA 8+39 3775 3780 3785 3790 3795 3800 3805 3810 3815 3775 3780 3785 3790 3795 3800 3805 3810 3815 -0+50 0+00 0+60 STA 9+40 3775 3780 3785 3790 3795 3800 3805 3810 3815 3775 3780 3785 3790 3795 3800 3805 3810 3815 -0+70 0+00 1+00 EX GRADEEX GRADE EX GRADE EX GRADE EX GRADE PROP GRADE PROP GRADE PROP GRADE PROP GRADE8" TRESS8" TRESS X100-YR ELEV: 3795.9 100-YR ELEV: 3793.8 100-YR ELEV: 3793.5 100-YR ELEV: 3793.5 100-YR ELEV: 3793.4 BASEFLOW ELEV: 3788.1 EX 8" TRUSS EX 8" TRUSS2:10.8:16' IRW #3 2' THICK 3"-4" STONE 6' 2' PROP GRADE NORMAL POOL ELEV: 3787.9 COBBLE DEPOSITION TO BE REMOVED AND REUSED FOR NEW ISLAND PROTECTION; FOREBAY POOL TO BE EXCAVATED3.3:12.4 :1 NORMAL POOL ELEV: 3787.9 DREDGE 3:13: 1 NORMAL POOL ELEV: 3787.9 NORMAL POOL ELEV: 3787.9 DREDGE DREDGE 3.5:13 : 1 4 : 1 6' THICK IMBRICATED ROCK WALL; SEE ROCK SIZING CHART DWG C300 FOR BOULDER SIZE PROP FENCE ELEV: 3804.33 ELEV: 3778.25 WET FILL DRY FILLPROP GRADE 6:1 18:1 2.5:16:1 0 VERTICAL SCALE: 1" = 5' 05 5 HORIZONTAL SCALE: 1" = 20' 20 10 20'PLOT DATE: 8/14/2019 6:54 PM BY: SKANEFile: O:\32453-ATL\32453-002\CAD_BIM\CIVIL\C222 Saved by SKANE Save date: 8/13/2019 9:53 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 AUGUST 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. CHECKED BY: DRAWN BY: DESIGNED BY: LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 LANDSCAPE ARCHITECT: SUPPORTING ENGINEER: T. SCHUELER S. KANE J. MCSWAIN - - T. SCHUELER C222 GRADING & DREDGING PROFILES (IRW #3 & EAST CHANNEL) H:- V:1" = 5'1" = 20' PROFILE NOTES: 1.ALL PROFILES FACING DOWNSTREAM STA 19+68 3775 3780 3785 3790 3795 3800 3775 3780 3785 3790 3795 3800 -2+00 -1+00 0+00 1+00 2+00 3+00 4+004+10 STA 18+03 3775 3780 3785 3790 3795 3800 3775 3780 3785 3790 3795 3800 -1+95 -1+00 0+00 1+00 2+00 3+00 4+00 4+40 DRY FILL DREDGE PROP GRADE PROP GRADE LARGE ISLAND"PETE'S ISLAND" WET FILL LEGEND DREDGE / EXCAVATE DRY FILL ISLAND PERIMETER BERM 100-YR ELEV: 3793.4 100-YR ELEV: 3793.3 FAIRWAY 18 WET FILL 5' UNDERCUT WET FILL NORMAL POOL ELEV: 3787.9 PROP GRADE EX GRADE 2.5' TYPICAL WESTERN SHORE FAIRWAY 18 WESTERN SHORE DRY FILL DREDGE / EXCAVATE WET FILL NORMAL POOL ELEV: 3787.9 PROP GRADE EX GRADE EX GRADE DREDGE ISLAND PERIMETER BERM; SEE DETAIL DWG C300 UNDERCUT* 10 : 1 25:1 2.5 :1 14: 1 19:1 60:1 60:1 14: 1 7.5:12:13.6:120:1 2:1 40:1 17: 1 10:1 2:13:14:15:17:10.5:11:12.5 :1 10:1 8:1 17:1 30:1 3:16:115:1 15: 1 0.5:110 : 1 EX ROCK WALL 0 VERTICAL SCALE: 1" = 5' 05 5 HORIZONTAL SCALE: 1" = 30' 30 15 30'PLOT DATE: 8/14/2019 6:55 PM BY: SKANEFile: O:\32453-ATL\32453-002\CAD_BIM\CIVIL\C223 Saved by JMCSWAIN Save date: 7/7/2019 1:50 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 AUGUST 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. CHECKED BY: DRAWN BY: DESIGNED BY: LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 LANDSCAPE ARCHITECT: SUPPORTING ENGINEER: T. SCHUELER S. KANE J. MCSWAIN - - T. SCHUELER C223 GRADING & DREDGING PROFILES LOCH DORNIE H:- V:1" = 5'1" = 30' PROFILE NOTES: 1.ALL PROFILES FACING DOWNSTREAM STA 20+49 3775 3780 3785 3790 3795 3800 3775 3780 3785 3790 3795 3800 -1+65 -1+00 0+00 1+00 2+00 3+00 4+00 4+70 STA 21+77 3770 3775 3780 3785 3790 3795 3800 3770 3775 3780 3785 3790 3795 3800 0+00 1+00 2+00 3+00 4+00 5+00 6+00 6+30 PROP GRADE PROP GRADE 100-YR ELEV: 3793.3 100-YR ELEV: 3793.3 18 GREEN SMALL ISLAND WESTERN SHORE LARGE ISLAND WESTERN SHORE 5' UNDERCUT 5' UNDERCUT EX GRADE EX GRADE WET FILL LEGEND DREDGE / EXCAVATE DRY FILL ISLAND PERIMETER BERM UNDERCUT* EXISTING ISLANDFAIRWAY 18 DRY FILL WET FILL DREDGE DREDGE / EXCAVATE DRY FILL DREDGE NORMAL POOL ELEV: 3787.9 NORMAL POOL ELEV: 3787.96.5:130:1 EX ROCK WALL 30:1 30:1 7.5:13:13:16:130:1 100:1 4 . 5 : 1 2:1 10 : 1 20:1 20:1 6:12:14:130:1 10:1 2:13:12:12.5:110 : 1 2:13:1 60:11:11:110 : 1 100:1 20:1 30:1 6.5:12.5:110:1 20:1 ISLAND PERIMETER BERM; SEE DETAIL DWG C300 ISLAND PERIMETER BERM; SEE DETAIL DWG C300 0 VERTICAL SCALE: 1" = 5' 05 5 HORIZONTAL SCALE: 1" = 30' 30 15 30'PLOT DATE: 8/14/2019 6:56 PM BY: SKANEFile: O:\32453-ATL\32453-002\CAD_BIM\CIVIL\C224 Saved by JMCSWAIN Save date: 7/7/2019 1:50 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 AUGUST 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. CHECKED BY: DRAWN BY: DESIGNED BY: LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 LANDSCAPE ARCHITECT: SUPPORTING ENGINEER: T. SCHUELER S. KANE J. MCSWAIN - - T. SCHUELER C224 GRADING & DREDGING PROFILES (LOCH DORNIE) H:- V:1" = 5'1" = 30' PROFILE NOTES: 1.ALL PROFILES FACING DOWNSTREAM STA 51+76 3780 3785 3790 3795 3800 3805 3810 3780 3785 3790 3795 3800 3805 3810 -0+30 0+00 0+60 STA 23+89 3770 3775 3780 3785 3790 3795 3800 3805 3770 3775 3780 3785 3790 3795 3800 3805 0+00 1+00 2+00 3+00 3+10 STA 53+13 3780 3785 3790 3795 3800 3805 3810 3815 3780 3785 3790 3795 3800 3805 3810 3815 -0+45 0+00 0+80 STA 54+91 3780 3785 3790 3795 3800 3780 3785 3790 3795 3800 -0+45 0+00 0+40 XXX DRY FILL PROP GRADE 8" TRUSS 8" TRUSS100-YR ELEV: 3793.3 100-YR ELEV: 3793.8 100-YR ELEV: 3793.5 100-YR ELEV: 3793.4 EVENT LAWN EX 8" TRUSS EX GRADE EX GRADE EX GRADE EX GRADE WET FILL PROP WALL; FOR WALL DESIGN INFORMATION, SEE DWG W100-101 NORMAL POOL ELEV: 3787.9 100:1 60:1 16:1 10:1 0.3:12.5 :1 PROP GRADE NORMAL POOL ELEV: 3787.9 DREDGE PROP GRADE DREDGE 1.5:12:1 DREDGE 3:13 : 1 NORMAL POOL ELEV: 3787.9 2:12:1EX 8" TRUSS NORMAL POOL ELEV: 3787.9 0 VERTICAL SCALE: 1" = 5' 05 5 HORIZONTAL SCALE: 1" = 20' 20 10 20'PLOT DATE: 8/14/2019 6:56 PM BY: SKANEFile: O:\32453-ATL\32453-002\CAD_BIM\CIVIL\C225 Saved by JMCSWAIN Save date: 7/7/2019 1:50 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 AUGUST 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. CHECKED BY: DRAWN BY: DESIGNED BY: LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 LANDSCAPE ARCHITECT: SUPPORTING ENGINEER: T. SCHUELER S. KANE J. MCSWAIN - - T. SCHUELER C225 GRADING & DREDGING PROFILES (WESTERN CHANNEL AND EVENT LAWN) H:- V:1" = 5'1" = 20' PROFILE NOTES: 1.ALL PROFILES FACING DOWNSTREAM A-A 3780 3785 3790 3795 3800 3805 3780 3785 3790 3795 3800 3805 0+00 1+00 2+00 2+75 STA 56+92 3780 3785 3790 3795 3800 3805 3780 3785 3790 3795 3800 3805 -2+20 -2+00 -1+00 0+00 0+40 STA 58+27 3780 3785 3790 3795 3800 3805 3810 3780 3785 3790 3795 3800 3805 3810 -0+50 0+00 0+80 DREDGE PROP GRADE PROP GRADE 12" TRUSSWET FILL PROP GRADE 100-YR ELEV: 3793.4 100-YR ELEV: 3793.3 100-YR ELEV: 3793.3 EX GRADE EX GRADE EX GRADE NORMAL POOL ELEV: 3787.9 DREDGE 16:1 3 . 5 : 1 3:1NORMAL POOL ELEV: 3787.9 NORMAL POOL ELEV: 3787.9 NORMAL POOL ELEV: 3787.9 ISLAND DRIVE WESTERN SHORE 40:1 EX 12" TRUSS DRY FILL DREDGE 20:1 40:1 7.5:1 30:1 H:- V:1" = 3'1" = 30' PROFILE 0 VERTICAL SCALE: 1" = 5' 05 5 HORIZONTAL SCALE: 1" = 20' 20 10 20'PLOT DATE: 8/14/2019 6:57 PM BY: SKANEFile: O:\32453-ATL\32453-002\CAD_BIM\CIVIL\C226 Saved by JMCSWAIN Save date: 7/7/2019 1:50 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 AUGUST 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. CHECKED BY: DRAWN BY: DESIGNED BY: LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 LANDSCAPE ARCHITECT: SUPPORTING ENGINEER: T. SCHUELER S. KANE J. MCSWAIN - - T. SCHUELER C226 GRADING & DREDGING PROFILES NOTES: 1.ALL PROFILES FACING DOWNSTREAM PLOT DATE: 8/14/2019 6:57 PM BY: SKANEFile: O:\32453-ATL\32453-002\CAD_BIM\DETAILS\D1 Saved by JMCSWAIN Save date: 7/7/2019 1:59 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 AUGUST 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. CHECKED BY: DRAWN BY: DESIGNED BY: LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 LANDSCAPE ARCHITECT: SUPPORTING ENGINEER: T. SCHUELER S. KANE J. MCSWAIN - - T. SCHUELER C300 REVETMENT DETAILS B U R Y E N D S O F W A L L 2 R O C K L E N G T H S (6 F T M I N I M U M ) BANKFULL BASE FLOW PLAN VIEW TYPICAL SECTIONISOMETRIC VIEW FILL GAPS BETWEEN STONES AS NEEDED TO TRANSITION INTO SLOPE ABOVE PROPOSED TOP OF SLOPE (SEE PLANS) SEE PLAN FOR DETAILS ON SEEDING, EROSION CONTROL PLACEMENT PLANTING, AND SLOPE LEADING AND TAILING ENDS OF WALL TAPERED 15°-30° AND BURIED INTO BANK 2 ROCK LENGTHS (MIN) BANKFULL FLOW ELEVATION 6" (MIN)CAMBERPROPOSED COMPACTED FILL AND COIR MAT AT TERMINAL ENDS TO MATCH EXISTING SLOPE STREAM CHANNEL INVERT AT STREAMBANK COIR COVER MAT PROTECTED BACKFILL UNLESS NOTED OTHERWISE TIE IN EROSION CONTROL MATTING (PER COIR FIBER MATTING DETAIL) UNLESS NOTED OTHERWISE STABILIZED VEGETATION UNLESS NOTED OTHERWISE OVERLAP EROSION CONTROL MATTING 12" BEHIND FILTER FABRIC FILTER FABRIC (NON-WOVEN) EXISTING SUBSOIL OR STREAMBED MATERIAL #57 STONE BEDDING SUPPORT (12" MIN THICK) OVER FILTER FABRIC (BI 216) FOOTER ROCK WIDTH 6"APPROVED FILL COMPOST AND TOPSOIL (6" MIN) STREAM BANK CHANNEL CL IMBRICATED ROCK WALL (IRW) DETAIL NTS FOOTER ROCK/BOULDER (TYP) BOULDER (STACKED IMBRICATED) PER TABLE (BI 215) Df H BOTTOM ELEV FOOTER ROCK/BOULDER PLACED BELOW STREAM INVERT (SET ROCK/BOULDER PERPENDICULAR TO FLOW), SEE Df VALUE IN TABLE FOOTER STONES PLACED BELOW STREAM INVERT SEE Df VALUE IN TABLE (SET STONES PERPENDICULAR TO FLOW) TOP ELEV V 2 SURFACE FOOTER STONES REQUIRED. ADDITIONAL SUBSURFACE FOOTERS MAY BE REQUIRED, SEE Df VALUE IN TABLE UPSTREAM STA DOWNSTREAM STA STREAM F L O W FOOTER TOE* SEE TABLE BASE FLOW ELEVATION STREAM CHANNEL INVERT 15-30°6 1 STACK IMBRICATED RIPRAP SO THAT TOP SURFACE OF ROCK IS AT A 6:1 (H:V) ANGLE FROM THE HORIZONTAL PLANE ISLAND PERIMETER BERM (PB) DETAIL NTS NOTES: 1.GEOTECHNICAL CONSULTANT TO BE ONSITE DURING CONSTRUCTION TO DETERMINE DEPTH NEEDED FOR UNDERCUT 2.3D GEOMAT TO BE ENKAMAT (OR APPOVED EQUIVALENT); SEE 3D GEOMAT DETAIL FOR INSTALLATION INSTRUCTIONS APPROVED FILL BROUGHT UP IN 12" LIFTS COMPACTED TO 95% "LOCH" SIDE "ISLAND" SIDE 2:1 1 : 1 ISLAND PERIMETER TYPICAL SECTION (STEP 1) 5' UNDERCUT AS NEEDED 20'10'10'10' 5'5' FINAL "CAP" GRADING PER SITE PLANS COMPACTED TO 95% "LOCH" SIDE "ISLAND" SIDE 2:1 1:1ISLAND PERIMETER TYPICAL SECTION (STEP 2) APPROX. 7' DRY MATERIAL COMPACTED TO 90% APPROVED FILL TO 95% PLACE 2'-3' WET MATERIAL 3D GEOMAT THICK LAYER OF FIELD HARVESTED COBBLE NORMAL POOL ELEVATION APPROVED FILL TO 95% NOTES: 1.FOR ROCK SIZE, SEE ROCK SIZING CHART. 2.STONES SHALL BE OVERLAIN IN THE DOWNSTREAM DIRECTION AT A 6 TO 1 SLOPE (9.5 DEGREES) 3.FILTER CLOTH SHALL BE PLACED ON THE UPSTREAM FACE OF THE SILL. STREAM BED MATERIAL (SBM) SHALL BE PLACED AS NECESSARY BETWEEN THE CLOTH AND THE PLACED STONES AND SBM SHALL BE USED TO FILL ALL VOIDS. GRADE CONTROL SILL (GCS) DETAIL NTS GRADE CONTROL SILL (GCS) SCHEDULE AREA STRUCTURE ID STA APEX (LOC = X) X OFFSET FROM CL (FT) STA APEX (LOC = Y) Y OFFSET FROM CL (FT) L (FT) Df (FT) ELEV X ELEV Y NOTES J-CLUSTER GCS1 3+07 5.0 2+72 43.0 60 6 3814.0 3816.0 J-CLUSTER GCS2 3+65 2.0 3+50 42.0 50 6 3810.0 3812.0 J-CLUSTER GCS3 4+28 6.0 4+14 38.0 50 6 3808.0 3810.0 J-CLUSTER GCS4 4+87 10.0 4+85 20.0 30 6 3806.0 3808.0 ROCK SIZING CHART - LINVILLE RIVER / LOCH DORNIE TYPE OF REVETMENT SUBCOMPONENT PURPOSE MATERIAL MIN AXIS (INCHES)NCDOT CLASS NOTES DETAIL REFERENCE GRADING TOLERANCE IMBRICATED ROCK WALL (IRW) WALL STONE (IRW#1)BANK PROTECTION RIP RAP 36 CLASS 2+FLAT, STACKABLE STREAM DETAILS DWG D-200 1.0' +/- HOR; 0.2' +/- VERT WALL STONE (IRW#2 AND 3) BANK PROTECTION RIP RAP 24 CLASS 2+FLAT, STACKABLE SUPPORT STONE SUPPORT AND DRAINAGE STONE 3 #4 STONE RAILROAD BALLAST FOOTER STONE GRADE CONTROL RIP RAP 48 CLASS 2+FLAT, STACKABLE GRADE CONTROL SILL (GCS)SILL STONE GRADE CONTROL RIPRAP 36 CLASS 2+FLAT, STACKABLE STREAM DETAILS DWG D-200 0.5' +/- HOR; 0.2' +/- VERT HARVESTED COBBLES ISLAND PROTECTION BANK PROTECTION COBBLES AND SMALL BOULDERS 4 CLASS A 4 TO 12 INCH ACCEPTABLE NA NA IMBRICATED ROCK WALL (IRW) SCHEDULE ** STRUCTURE # UPSTREAM STA UPSTREAM OFFSET AT FOOTER TOE * (FT) TOP ELEV (UPSTREAM) BOTTOM ELEV * (UPSTREAM) DOWNSTREAM STA DOWNSTREAM OFFSET AT FOOTER TOE * (FT) TOP ELEV (DOWNSTREAM) BOTTOM ELEV * (DOWNSTREAM) LENGTH BOTTOM WALL* (FT) LENGTH TOP WALL* (FT) WALL SLOPE (H:V) FOOTER TOE WIDTH (FT) FOOTER DEPTH Df (FT)NOTES IRW-1 2+65; 2+90 27; 1 3830.0 3815.0 4+95 8.0 3810.0 3807.0 208.0 190.0 1 TO 1 6.0 6.0 WALL SLOPE MAY VARY (BE PLACED LESS STEEP THAN DESIGN BUT STILL WITHIN FOOTPRINT); WALL TO BE LAIN ON 2-FOOT-THICK LAYER OF 3-4" STONE IRW-2 (ADDITIONAL INFO) 3+50 NA 3829.0 3811.0 NA NA NA NA NA NA NA NA NA IRW-2 1+67 18.0 3829.0 3828.0 5+02 32.0 3822.0 3821.0 320.0 320.0 0.5 TO 1 6.0 6.0 IRW-2 (ADDITIONAL INFO) 3+80 NA 3824.0 3814.0 NA NA NA NA NA NA NA NA NA IRW-3 8+08 14.0 3807.0 3790.0 8+72 17.0 3803.0 3787.0 80.0 65.0 0.5 TO 1 6.0 6.0 * OFFSET, ELEVATION AND LENGTH MEASURED AT TOE OF FOOTER STONE (SEE TYPICAL SECTION) ** SEE ROCK SIZING CHART FOR STONE SIZE PLOT DATE: 8/14/2019 6:57 PM BY: SKANEFile: O:\32453-ATL\32453-002\CAD_BIM\DETAILS\D2 Saved by JMCSWAIN Save date: 7/4/2019 5:39 PM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 AUGUST 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. CHECKED BY: DRAWN BY: DESIGNED BY: LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 LANDSCAPE ARCHITECT: SUPPORTING ENGINEER: T. SCHUELER S. KANE J. MCSWAIN - - T. SCHUELER C301 STANDARD DETAILS STANDARD SPLIT-RAIL FENCE DETAIL NTS NOTES: 1.ALL WOOD FOR SPLIT RAIL FENCE TO BE PRESSURE TREATED 2.END POST SHALL BE TERMINAL POST 3.ALL POSTS SHALL BE EMBEDDED 2 FT AND ENCASED IN CONCRETE XXXXXSSSSSSSSSSSSLODLODLODLODLODLODLODLODLODLODLODLODLOD LODLOD LOD LOD LODLODLODLODLODLODLODLOD LODXXXXX158.53°'103.02°'77.10°'3784 3785 3790 3795 3800 3805 3810 3815 3784 3785 3790 3795 3800 3805 3810 3815 -0+15 0+00 1+00 1+15SSMH-2INV OUT: 3806.14 (RJ DIP)STA 1+05.3RIM: 3812.06DEPTH: 5.92STA: 0+14.00BEGIN PIPE INSULATIONSTA: 0+75.00END PIPE INSULATIONSSMH-1INV IN: 3805.09 (RJ DIP) INV IN: 3803.15 (TRUSS) INV OUT: 3803.11 (TRUSS)STA 0+00.0RIM: 3808.81DEPTH: 5.70100-YR ELEV: 3796.04STA: 0+04.91BEGIN PIPE CASINGSTA: 0+05.91END PIPE CASINGSTA: 0+85.91BEGIN PIPE CASINGSTA: 0+86.91END PIPE CASING105 LF 8" DIP @ 1.00%XSSSSSSSS SS SS SS SS SS SS LODLODLOD LOD LOD LOD LOD NOTES: 1.SSMH-1 SHALL BE A DOGHOUSE MANHOLE. SEE DETAILS C-33-0601 AND C-33-0602 THIS SHEET. 2.SSMH-1 SHALL BE FLUSH WITH PROPOSED GRADING BY STEWART, INC. 3.RJ DIP SHALL BE INSULATED ON AERIAL CROSSING BETWEEN STATIONING AS SHOWN ON PLANS ACCORDING TO INSUL-TEK DUCTILE IRON SYSTEM SPECIFICATIONS OR EQUIVALENT. 4.RJ DIP SHALL BE CASED WITHIN ABUTMENTS WITH STEEL CASING. SEE DETAIL 2 ON B402 AND B502. 5.SEE B401 FOR BRIDGE 4 CONSTRUCTION SEQUENCE. CONSTRUCTION SEQUENCE BRIDGE 5 1.INSTALL SCAFFOLDING AS REQUIRED FOR BRIDGE INSTALLATION. 2.CONSTRUCT PROPOSED BRIDGE AND RJ DIP SEWER HANGING FROM BRIDGE. 3.INSTALL DOGHOUSE SSMH-1 AND CONNECT EXISTING 8" TRUSS PIPE. CUT AND REMOVE PIPE WITHIN MANHOLE. CONNECT PROPOSED 8" RJ DIP TO SSMH-1. 4.PLUG 8" TRUSS AT EXISTING SSMH UPSTREAM FROM PROPOSED SSMH-2. 5.INSTALL SSMH-2 AS SHOWN AND REMOVE EXISTING 8" TRUSS PIPE AS NECESSARY FOR INSTALLATION. 6.CONNECT PROPOSED 8" RJ DIP TO SSMH-2. REMOVE WATERTIGHT PLUG AT EXISTING UPSTREAM SSMH. 7.REMOVE EXISTING BRIDGE AND EXISTING 8" TRUSS PIPE BETWEEN EX-SSMH-1 AND SSMH-2. PLUG EX-SSMH-1 AFTER REMOVING EXISTING 8" TRUSS PIPE. SCALE: 1" = 10' PLAN H:- V:1" = 3'1" = 10' PROFILE PLOT DATE: 8/14/2019 6:58 PM BY: SKANEFile: O:\32453-ATL\32453-002\CAD_BIM\CIVIL\C400 Saved by MBATE Save date: 7/9/2019 5:05 PM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 AUGUST 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. CHECKED BY: DRAWN BY: DESIGNED BY: LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 LANDSCAPE ARCHITECT: SUPPORTING ENGINEER: PROPOSED 105 LF 8" C L A S S 3 5 0 R J D I P ( E P O X Y - L I N E D ) @ 1 . 0 0 % SSMH-2 (4'Ø) RIM: 3812.06 8" TRUSS IN (SE) I.E.: 3806.24 8" RJ DIP OUT (NW) I.E.:3806.14 8" TR U S S P I P E 8" TRUSS PIPE8" TRUSS PIPE4" PVC PIPE96 LF 8" TRUS S P I P E T O B E R E M O V E D 4" PV C PI P E 4" CPP SSMH-1 (4'Ø) TOP EL: 3808.81 8" RJ DIP IN (SE) I.E.: 3805.09 8" TRUSS IN (NE) I.E.: 3803.15 8" TRUSS OUT (SW) I.E.: 3803.11 SEE NOTE 1 EXISTING SSMH RIM: 3808.32 4" PVC IN (E) I.E.:3806.42 8" (DROP) TRUSS IN (SE) I.E.: 3805.60 (UPPER) 8" (DROP) TRUSS IN (SE) I.E.: 3804.6' (LOWER) 4" PVC IN (NW) I.E.: 3805.02 8" TRUSS IN (NE) I.E.: 3803.60 8" TRUSS OUT (SE) I.E.: 3803.20 REMOVE EXISTING SSMH RIM: 3810.40 WM WATERTIGHT PLUG PEDESTRIAN BR I D G E T O B E D E M O L I S H E D WATERTIGHT FRAME AND COVER FLUSH WITH GRADE WATERTIGHT FRAME AND COVER FLUSH WITH GRADE, SEE NOTE 2 8" TRUSS IN (SE) I.E.: 3805.98 8" TRUSS OUT (NW) I.E.: 3805.87 + 6" MINPIPE OD 2R =RFLOOR SLAB.12" MIN8" THICK MIN CRUSHED #57 STONE BASE DIAMETER OF MANHOLE BASE. GREATER THAN OUTSIDE SLAB, SIDE LENGTH 12" CLASS "A" CONCRETE SQUARE 4" MIN IN CONCRETE SUCH THAT IT IS EMBEDDED PLACE MH BASE SECTION DOGHOUSE PRECAST MANHOLES C-33-0602 NOTES: 1.CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN OF THE BOTTOM SLAB. 2.THIS DETAIL SHALL BE USED FOR STORMWATER STRUCTURES ONLY. DOGHOUSE TYPE MANHOLES SHALL NOT BE USED FOR PROCESS STRUCTURES. 3.FILL ANNULAR SPACE BETWEEN OUTSIDE OF PIPE AND MH WITH CONCRETE OR MASONRY TO INSURE WATERTIGHTNESS. CLASS 'B' CONCRETE FILL MANHOLE STEPS AT 16" OC GROUT AS REQUIRED SEE MANHOLE SCHEDULE 8"TYPSLOPE 1/2" PER FT SST CLAMP MANHOLE SECTION 12" C-33-0601 COMPACTED #57 CRUSHED STONE MANHOLE COVER AND FRAME (SEE SPECS) GRADE RING AS REQUIRED 4" THICK MAX (2) PER MANHOLE. FLOW CHANNEL BENCH FLEXIBLE RUBBER SLEEVE BOOT FLOW CHANNEL T. SCHUELER M.BATE M. BATE - - T. SCHUELER C400 SANITARY SEWER PLAN, PROFILE, & DETAIL NOTE: PIPE HUNG FROM PROPOSED BRIDGE 5, SEE DWG B501 FOR DETAIL CIVIL STRUCTURES - SANITARY ID AREA TYPE DIAMETER STANDARD STATION TOP ELEV LOWEST ELEV OUT SSMH-1 BRIDGE 5 DOGHOUSE 48 INCH C-33-0602 0+00.0 3808.8100 3803.1100 SSMH-2 BRIDGE 5 WATERTIGHT 48 INCH C-33-0601 1+05.3 3812.0600 3806.1400 PIPE SCHEDULE AREA USE FROM TO SIZE TYPE CLASS LENGTH BRIDGE 5 SANITARY SSMH-2 SSMH-1 8 INCH DIP 350 105 LF BRIDGE 4 SANITARY EX-SSMH-3 EX-SSMH-4 6 INCH DIP 350 137.3 LF SCALE: 1" = 10' PLAN REMOVE SECTION OF 8" PIPE WITHIN MANHOLE EXIS T I N G U P S T R E A M S S M H APP R O X . 1 4 8 L F F R O M S S M H - 2 PROP O S E D 1 3 7 L F O F 6 " R J DI P ( G ) ( E P O X Y - LI N E D ) @ 1. 7 6 % EX-SSMH-3 RIM: 3800.89 6" PVC IN (I) I.E.: 3795.97 6" RJ DIP IN (G) I.E.: 3797.48 12" TRUSS IN (F) I.E.: 3791.44 6" PVC IN (H) I.E.: 3791.41 12" TRUSS OUT (J) I.E.: 3791.14 EX-SSMH-4 RIM: 3796.01 6" PVC IN I.E.: 3793.97 6" TRUSS OUT I.E.:3793.89 137 LF 6" TRUSS PIPE TO BE REMOVED EX-SSMH-2EX-SSMH-1 PEDE S T RI A N B RI D G E T O B E D E M O LI S H E D A N D R E P L A C E D 12" TRUSS (F)6" P V C ( H )6" PVC (I)12" TRUSS (J)0 0 VERTICAL SCALE: 1" = 1' 1 1' HORIZONTAL SCALE: 1" = 10' 10 5 10' LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODL O D L O D LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLOD LODLODLOD LOD LODLODLOD LODLODLOD LODLODL O D L O D LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD L O D LO D BRIDGE 5 ALL B501 BUILDING H BUILDING H EXISTING EDGE OF WATER BUILDING CBUILDING C TEE 18 TEE 18 TEE 18 TEE 18CART PATH PA PA PA SANITARY SEWER WORK BY OTHERS, SEE SHEET C400 PROPOSED CONCRETE PAVING 6 L500 WORK BY OTHERS, SEE SHEET C202 PLOT DATE: 7/4/2019 8:41 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-L100 SITE PLAN Saved by CLANDOLL Save date: 7/4/2019 7:48 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: N/A 15 1" = 30' 30 0 30' SCALE: 1"=30' PLAN 1 2 43 5 6 7 7 AMENITIES WORK *NO AMENITIES WORK *NO AMENITIES WORK *NO PROPOSED BRIDGE LIMITS OF DISTURBANCE PROPOSED PLANTING AREA SITE LEGEND: LOD SITE PLAN AREA 2 2 C. LANDOLL J. WARNER J. WARNER C. LANDOLL NOTE: SEE GRADING & DREDGING PLANS FOR ALL DREDGING-RELATED GRADING, AND THE AMENITIES GRADING & STORMWATER PLAN FOR ALL AMENITIES GRADING. PA AMENITIES AREA 3 (NO AMENITIES WORK) AREA 1 (NO AMENITIES WORK) L102 LODL O D L O D L O D LODLOD LOD LO D LODLOD LOD LOD LOD LODLODLODLODLODLODLODLOD LOD LOD LODLODLODLODLODLODLODLODLODLODLOD LOD LODLODLODLODLODLODLODLODLODLODLODLOD LOD LODLODLODLODLODLODLODPA PA PA PA PA PA PROPOSED LARGE ISLAND BRIDGE 4, PROPOSED PROPOSED RIVER ROCK APRON UNDER BRIDGE, TYP. RELOCATED EXISTING BOULDERS (2) PROPOSED BOULDER, TYP. BRIDGE 3, PROPOSED PROPOSED LAWN BUILDING E BUILDING BUILDING BUILDING 5 L500 ALL B301 1 L501 BUILDING PA PA PA PA PROPOSED ASPHALT PATH 2 L500 ALL B401 PROPOSED BRIDGE ABUTMENT, TYP. ALL B002 PROPOSED STONE SCREENINGS PATH 4 L500 PROPOSED STONE SCREENINGS PATH 4 L500 PA PLOT DATE: 7/4/2019 8:41 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-L100 SITE PLAN Saved by CLANDOLL Save date: 7/4/2019 7:48 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: N/A 15 1" = 30' 30 0 30' SCALE: 1"=30' PLAN MATCH LINE - SEE L106MATCH LINE - SEE L107 1 2 43 5 6 7 7 AMENITIES WORK *NO AMENITIES WORK *NO AMENITIES WORK *NO PROPOSED BRIDGES PROPOSED STONE SCREENINGS TRAIL PROPOSED ROCK APRON PROPOSED BOULDER LIMITS OF DISTURBANCE PROPOSED PLANTING AREA SITE LEGEND: LOD 5 C. LANDOLL J. WARNER J. WARNER C. LANDOLL NOTE: SEE GRADING & DREDGING PLANS FOR ALL DREDGING-RELATED GRADING, AND THE AMENITIES GRADING & STORMWATER PLAN FOR ALL AMENITIES GRADING. SITE PLAN AREA 5 AMENITIES PA L105 LOD LOD LOD LO D L O D LO D LOD LODLODLODLODLOD LODLODLODLODLODLOD LOD LODLODLODLODLODL O D L O D LODLODLODLODLODLODLODLODLODLOD LO D LO D LOD LODLODLODLODLODLODLODLOD LODLODLODLODLODLODLODL O D L O D L O D LODLODLODEX. TREE TO REMAIN PROPOSED LAWN PROPOSED LAWN PA PA BRIDGE 1, PROPOSED PROPOSED STONE SCREENINGS PATH, TYP. PROPOSED LAWN PA PA PA PA PROPOSED LARGE ISLAND BRIDGE 2, PROPOSED PROPOSED BRIDGE ABUTMENT PROPOSED ROCK APRON UNDER BRIDGE, TYP. PROPOSED SHORE LINE, TYP. PROPOSED RIVER ROCK APRON UNDER BRIDGE, TYP. RELOCATED EXISTING BOULDERS (2) PROPOSED BOULDER, TYP. PA BRIDGE 3, PROPOSED PROPOSED LAWN PROPOSED SMALL ISLAND EX. GOLF COURSE EX. CLUB HOUSE EX. CLUB HOUSE PATIO EX. CROQUET COURT ALL B002 ALL B201 ALL B101 5 L500 ALL B301 1 L501 PROPOSED CONCRETE WALL W/ MANUFACTURED STONE VENEER 3 W100 PROPOSED CONCRETE WALL W/ MANUFACTURED STONE VENEER 2 W100 PROPOSED STEEL HANDRAIL, TYP. 1 L501 PROPOSED ASPHALT PATH 1 L500 ADA ACCESSIBLE ROUTE PROPOSED STONE STAIR, TYP. 3 L501 PROPOSED STEEL HANDRAIL, TYP. 2 L501 PA BUILDING PROPOSED BOULDER, TYP. 1 L501 PARKING AREA FOR EVENT ACCESS PROPOSED STEEL HANDRAIL, TYP. PROPOSED SWALE, SEE STORMDRAIN PLAN 2 L501 PROPOSED STONE SCREENINGS PATH 4 L500 2 W100 1 W100 3 W100 PA PA PA PA PA PA PA PA PA PA PA PA PA PA PA 5 C900 4 L500 PROPOSED CONCRETE WALL W/ MORTARED FIELD RUBBLE VENEER 1 W100 PLOT DATE: 7/4/2019 8:42 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-L100 SITE PLAN Saved by CLANDOLL Save date: 7/4/2019 7:48 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: PA N/A 15 1" = 30' 30 0 30' SCALE: 1"=30' PLANMATCH LINE - SEE L105MATCH LINE - SEE L107 PROPOSED ASPHALT PATH PROPOSED STONE PAVING PROPOSED STONE SCREENINGS TRAIL PROPOSED ROCK APRON PROPOSED WALLS PROPOSED BOULDER PROPOSED BRIDGES PROPOSED PLANTING AREA LIMITS OF DISTURBANCE ADA ACCESSIBLE ROUTE SITE LEGEND: LOD 1 2 43 5 6 7 7 AMENITIES WORK *NO AMENITIES WORK *NO AMENITIES WORK *NO 6 C. LANDOLL J. WARNER J. WARNER C. LANDOLL SITE PLAN AREA 6 AMENITIES NOTE: SEE GRADING & DREDGING PLANS FOR ALL DREDGING-RELATED GRADING, AND THE AMENITIES GRADING & STORMWATER PLAN FOR ALL AMENITIES GRADING. L106 LODLODLODLODLOD LODLODLODLODLODLODLODLODLOD LOD LOD LODLODLODLODLODLODLODLODL O D L O D LODLODLODLODLODLODLODLODLODLODLOD LO D LO D LO D LODLOD LODLODLODLODLODLODLODLODLODLODEX. TREE TO REMAIN PROPOSED LAWN PROPOSED LAWN PA PA EX. CLUB HOUSE EX. CLUB HOUSE PATIO EX. CROQUET COURT PROPOSED CONCRETE WALL W/ MANUFACTURED STONE VENEER 3 W100 PROPOSED CONCRETE WALL W/ MANUFACTURED STONE VENEER 2 W100 PROPOSED STEEL HANDRAIL, TYP. 1 L501 1 L500 ADA ACCESSIBLE ROUTE PROPOSED STONE STAIR, TYP. 3 L501 PROPOSED STEEL HANDRAIL, TYP. 2 L501 BUILDING PROPOSED BOULDER, TYP. 1 L501 PARKING AREA FOR EVENT ACCESS PROPOSED STEEL HANDRAIL, TYP. PROPOSED SWALE, SEE STORMDRAIN PLAN 2 L501 2 W100 1 W100 3 W100 PA PA PA PA PA PROPOSED ASPHALT PATH PROPOSED CONCRETE WALL W/ MORTARED FIELD RUBBLE VENEER 1 W100 BRIDGE 1, PROPOSED 1 L501 PLOT DATE: 7/4/2019 8:42 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-L100 SITE PLAN Saved by CLANDOLL Save date: 7/4/2019 7:48 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: R. MASSEY 10 20'020 1" = 20' SCALE: 1"=20' PLANMATCH LINE - SEE DWG L105MATCH LINE - SEE DWG L107 PROPOSED ASPHALT PATH PROPOSED STONE PAVING PROPOSED STONE SCREENINGS TRAIL PROPOSED ROCK APRON PROPOSED WALLS PROPOSED BOULDER PROPOSED BRIDGES PROPOSED PLANTING AREA LIMITS OF DISTURBANCE ADA ACCESSIBLE ROUTE SITE LEGEND: LOD 1 2 43 5 6 7 7 AMENITIES WORK *NO AMENITIES WORK *NO AMENITIES WORK *NO PA 6 C. LANDOLL J. WARNER J. WARNER C. LANDOLL SITE PLAN AREA 6 ENLARGEMENT AMENITIES L106.1 LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLO D LO D LOD LOD LOD LOD LOD L O D LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD PROPOSED STONE SCREENINGS PATH, TYP. 4 L500 EXISTING WETLAND TO REMAIN AND BE PROTECTED DURING CONSTRUCTION LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLO D L O D LODLODLODLODLODLOD LODLODLODLOD LOD LOD LOD LOD LODLODLODLODLODPROPOSED STONE SCREENINGS PATH, TYP. 4 L500 EXISTING WETLAND TO REMAIN AND BE PROTECTED DURING CONSTRUCTION PA PA PLOT DATE: 7/4/2019 8:42 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-L100 SITE PLAN Saved by CLANDOLL Save date: 7/4/2019 7:48 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: N/A PROPOSED STONE SCREENINGS TRAIL PROPOSED BOULDER LIMITS OF DISTURBANCE PROPOSED PLANTING AREA SITE LEGEND: 15 1" = 30' 30 0 30' SCALE: 1"=30' PLAN MATCH LINE - SEE DWG L105 MATCH LINE - SEE THIS SHEET MATCH LINE - SEE THIS SHEET 1 2 43 5 6 7 7 AMENITIES WORK *NO AMENITIES WORK *NO AMENITIES WORK *NO LOD 7 C. LANDOLL J. WARNER J. WARNER C. LANDOLL 7 SITE PLAN AREA 7 AMENITIES PA NOTE: SEE GRADING & DREDGING PLANS FOR ALL DREDGING-RELATED GRADING, AND THE AMENITIES GRADING & STORMWATER PLAN FOR ALL AMENITIES GRADING. L107 37813785378437853784378337813 7 8 4 3783378537873787 378737853784378437843784 378 53785 3784LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODL O D L O D LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLOD LODLODLOD LOD LODLODLOD LODLODLOD LODLODL O D L O D LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD L O D LO D 3 8 1 1 3 8 1 0 3809 3808 38073808 ALL B501 BRIDGE 5 REALIGN SEWER LINE SEE SEWER PLANS PLOT DATE: 7/4/2019 8:44 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-C500 STORMWATER PLAN Saved by CLANDOLL Save date: 7/4/2019 7:48 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: L202 1 2 43 5 6 7 7 AMENITIES WORK *NO AMENITIES WORK *NO AMENITIES WORK *NO 15 1" = 30' 30 0 30' PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR PROPOSED STORM DRAINAGE PROPOSED AREA DRAIN FLOW DIRECTION LIMITS OF DISTURBANCE 200 200 GRADING LEGEND: LOD 1.CONTRACTOR SHALL REPORT ANY GRADE DISCREPANCIES TO THE OWNER'S REPRESENTATIVE PRIOR TO BEGINNING CONSTRUCTION OPERATIONS. 2.THE MAXIMUM SLOPE ALONG ANY HANDICAP ACCESSIBLE PATHWAY SHALL NOT EXCEED 5.0% AND SHALL NOT EXCEED A 2.0% CROSS SLOPE. HANDICAP RAMPS INDICATED ON PLANS SHALL BE A MAXIMUM OF 1/12 SLOPES WITH A MAXIMUM RISE OF 30” BETWEEN LANDINGS. NON-CURB CUT RAMPS SHALL HAVE HANDRAILS AND GUARDS PER DETAILS WITH 5' LANDINGS AT THE BOTTOM AND TOP OF RAMP. 3.ALL PROPOSED ELEVATIONS SHOWN ARE EDGE OF PAVEMENT ELEVATIONS UNLESS OTHERWISE SPECIFIED. 4.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING THAT ALL NEWLY CONSTRUCTED STORM DRAINAGE IMPROVEMENTS AND RECEIVING STORM DRAINAGE SYSTEMS REMAIN CLEAN OF SEDIMENT AND DEBRIS. PRIOR TO OWNER ACCEPTANCE OF SYSTEM, THE CONTRACTOR SHALL COORDINATE AND PROVIDE A VISUAL OBSERVATION VIDEO OF ALL STORM DRAINAGE IMPROVEMENTS 12" AND LARGER. THE VISUAL OBSERVATION SHALL BE PERFORMED IN THE PRESENCE OF THE OWNER'S REPRESENTATIVE. THE CONTRACTOR SHALL PROVIDE TWO (2) DVD COPIES OF THE ENTIRE DRAINAGE VISUAL OBSERVATION. 5.PRIOR TO ISSUANCE OF A BUILDING CERTIFICATE OF OCCUPANCY THE CONTRACTOR SHALL PROVIDE THE OWNER WITH THE VIDEO INSPECTION OF THE STORM SEWER SYSTEM. (BOTH PUBLIC AND PRIVATE). THIS SUBMITTAL MAY NEED TO BE REVIEWED AND ACCEPTED BY THE LOCAL JURISDICTION PRIOR TO THE ISSUANCE OF THE BUILDING CO. 6.REFER TO THE EROSION CONTROL DETAILS SHEET FOR THE SEQUENCE OF CONSTRUCTION 7.INTERIM GRADING SHALL BE PROVIDED THAT ENSURES THE PROTECTION OF STRUCTURES, UTILITIES, SIDEWALKS, PAVEMENTS, AND OTHER FACILITIES FROM DAMAGE CAUSED BY SETTLEMENT, LATERAL MOVEMENT, UNDERMINING, AND WASHOUT. 8.INTERIM GRADING SHALL BE PROVIDED TO DIRECT WATER AWAY FROM BUILDINGS AND PREVENT PONDING. 9.TIE ROOF LEADERS WHERE POSSIBLE TO UNDERGROUND STORM SYSTEM. CONTRACTOR TO FIELD VERIFY LOCATE AND INSTALL WHERE POSSIBLE OR AS SHOWN ON PLANS. WHERE ROOF LEADERS DAYLIGHT AT GRADE A SPLASH BLOCK APPROVED BY THE OWNER'S REPRESENTATIVE SHALL BE INSTALLED. 10.MAXIMUM SLOPE ACROSS ANY HANDICAPPED PARKING SPACE AND AISLE SHALL NOT EXCEED 2% IN ANY DIRECTION. 11.PROPOSED CONTOURS ARE APPROXIMATE. SPOT ELEVATIONS AND ROADWAY PROFILES SHALL BE USED IN CASE OF DISCREPANCY. 12.PLACE BACKFILL AND FILL MATERIALS IN LAYER NOT MORE THAN 8 INCHES IN LOOSE DEPTH FOR MATERIAL COMPACTED BY HEAVY COMPACTION EQUIPMENT, AND NOT MORE THAN 4 INCHES IN LOOSE DEPTH FOR MATERIAL COMPACTED BY HAND-OPERATED TAMPERS. PLACE BACKFILL AND FILL MATERIALS EVENLY ON ALL SIDES TO REQUIRED ELEVATIONS, AND UNIFORMLY ALONG THE FULL LENGTH OF EACH STRUCTURE. COMPACT SOIL TO NOT LESS THAN 95 PERCENT OF MAXIMUM DRY UNIT WEIGHT ACCORDING TO ASTM D 698 FOR EACH LAYER OF BACKFILL OR FILL MATERIAL UP TO TWO FEET OF FINISHED GRADE. COMPACT SOIL TO NOT LESS THAN 98 PERCENT OF MAXIMUM DRY UNIT WEIGHT ACCORDING TO ASTM D 698 FOR EACH LAYER OF BACKFILL OR FILL MATERIAL FOR THE FINAL TWO FEET. 13.SITE GRADING IMMEDIATELY ADJACENT TO FOUNDATION OF BUILDING SHALL SLOPE NOT LESS THAN 1/20 AWAY FOR MINIMUM DISTANCE OF 10 FEET. ALTERNATIVE METHOD SHALL BE PROVIDED TO DIVERT WATER AWAY FROM FOUNDATION VIA SWALES SLOPED AT A MINIMUM OF 2% OR IMPERVIOUS SURFACES SLOPED AWAY A MINIMUM OF 2% AWAY FROM BUILDING. 14.CONTRACTOR SHALL ADJUST RIM ELEVATIONS OF EXISTING MANHOLES, METERS, VALVES, ETC. AS REQUIRED TO MEET NEW FINISHED GRADES. 15.CONTRACTOR SHALL SLOPE GRADES TO ASSURE POSITIVE STORMWATER FLOW TO KEEP WATER FROM POOLING ALONG CURBS AND WALLS. 16.TOP OF WALL ELEVATIONS INDICATE THE ELEVATION AT THE TOP OF THE CAP, UNLESS OTHERWISE NOTED. 17.BOTTOM OF WALL ELEVATIONS INDICATE THE ELEVATION OF THE FINISHED GRADE. GRADING AND STORM DRAINAGE NOTES: APPLIES TO SHEETS L202-L207TYPE CODE: AD = AREA DRAIN UPSTREAM GRD. ELEV. DOWNSTREAM GRD. ELEV. DOWNSTREAM STRC STORM DRAINAGE NETWORK UPSTREAM STRC FLOW UPSTREAM INVERT DOWNSTREAM INVERT 2 AMENITIES GRADING & STORMWATER PLAN AREA 2 AREA 3 (NO AMENITIES WORK) AREA 1 (NO AMENITIES WORK) R. MASSEY N/A J. WARNER J. WARNER R. MASSEY 3782 3 7 8 2 3781 3780 3780 3779377937803780 3779 3783 3781 3781 37823 7 8 1 3781 3 7 9 1 3790 3785 3787 3783 3 7 8 5 3 7 8 7 3 7 9 03791 3 7 8 5 3 7 8 7 3 7 893 7 8 4 37843 7 8 4 3 7 8 4 3 7 8 0 3782 37823 7 8 4 3 7 9 1 37 91 378837 9 0 37 8 8 37 9 3380037 9 5 3802LODL O D L O D L O D LODLOD LOD LO D LODLOD LOD LOD LOD LODLODLODLODLODLODLODLOD LOD LOD LODLODLODLODLODLODLODLODLODLODLOD LOD LODLODLODLODLODLODLODLODLODLODLODLOD LOD LODLODLODLODLODLODLOD3793379437953796379716 LF 12" HDPE @ 1.54% +HP 3794.70 + 3793.60 + 3793.30 + 3793.10 Structure - (25) RIM ELEV = 3792.80 INV OUT = 3790.25 Structure - (24) RIM ELEV = 3792.55 INV IN = 3790.00 (Structure - (25)) 16 LF 12" HDPE @ 1.54% BUILDING INV. OUT = 3790.00INV.IN = 3790.25 BRIDGE 4 ALL B401 ALL B301BRIDGE 3 PLOT DATE: 7/4/2019 8:44 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-C500 STORMWATER PLAN Saved by CLANDOLL Save date: 7/4/2019 7:48 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR PROPOSED STORM DRAINAGE PROPOSED AREA DRAIN FLOW DIRECTION LIMITS OF DISTURBANCE 200 200 GRADING LEGEND: L205 SCALE: 1" = 30' PLAN MATCH LINE - SEE DWG L206MATCH LINE - SEE DWG L207 15 1" = 30' 30 0 30' 1 2 43 5 6 7 7 AMENITIES WORK *NO AMENITIES WORK *NO AMENITIES WORK *NO LOD 5 AMENITIES GRADING & STORMWATER PLAN AREA 5 R. MASSEY N/A C. CROSBY C. CROSBY R. MASSEY AREA 3 (NO AMENITIES WORK)AREA 4 (NO AMENITIES WORK) 780 3780 3 7 7 9 3779377937803780 377937823 7 8 1 3781 3 7 9 1 3790 3785 3787 3783 3 78 3 3 7 8 0 37 8 0 3782 37823 7 7 5 37 9 0 37 8 8 37 9 3 3 7 9 3 3 7 9 0 3 7 8 8 37883790LOD LOD LOD LO D L O D LO D LOD LODLODLODLODLOD LODLODLODLODLODLOD LOD LODLODLODLODLODL O D L O D LODLODLODLODLODLODLODLODLODLOD LO D LO D LOD LODLODLODLODLODLODLODLOD LODLODLODLODLODLODLODL O D L O D L O D LODLODLOD3790379437953796 3797 3798 3799 3800 3801 38023803 38033802380138003799379837 9 1 101-AD RIM ELEV = 3797.65 INV IN = 3791.40 INV OUT = 3790.90 111-AD (NDS) RIM ELEV = 3799.28 INV OUT = 3791.37 68 LF 8" HDPE @ 0.54% +HP 3794.70 + 3793.60 + 3793.30 + 3793.10 + 3793.10 + 3793.50 + 3793.10 + 3793.05 Structure - (24) RIM ELEV = 3792.55 INV IN = 3790.00 (Structure - (25)) 108-AD RIM ELEV = 3798.39 INV OUT = 3794.39 107-AD RIM ELEV = 3796.50 INV IN = 3793.73 (108-AD) INV OUT = 3792.50 105-AD RIM ELEV = 3794.37 INV OUT = 3790.30 106-AD RIM ELEV = 3792.87 INV IN = 3788.63 (105-AD) INV IN = 3791.63 (107-AD) INV IN = 3788.87 () 16 LF 12" HDPE @ 1.54% 49 LF 12" HDPE @ 3.43% 73 LF 12" HDPE @ 1.19% 39 LF 12" HDPE @ 1.67% 104-AD RIM ELEV = 3794.40 INV OUT = 3785.45 17 LF 12" @ 12.02% INV. OUT = 3790.00 ALL B301BRIDGE 3 ALL B201BRIDGE 2 ALL B101 BRIDGE 1 INV OUT = 3789.61 UNDERDRAINS TO CONNECT TO NEAREST STORM STRUCTURE INV OUT = 3790.14 TOP OF WALL ELEVATIONS, SEE ENLARGEMENT, SHEET L206.1 13 LF 12" HDPE @ 13.01% 59 LF 24" HDPE @ 8.71% 72 LF 30" HDPE @ 2.62% CONCRETE RETAINING WALL 2 W100 CONCRETE RETAINING WALL 1 W100 CONTRACTOR TO FIELD VERIFY PIPE DRAINAGE DIRECTION AND INFORMATION. CONTRACTOR TO CONTACT ENGINEER FOR DESIGN DIRECTION. CONCRETE RETAINING WALL 3 W100 PLOT DATE: 7/4/2019 8:44 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-C500 STORMWATER PLAN Saved by CLANDOLL Save date: 7/4/2019 7:48 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: L206 SCALE: 1" = 30' PLAN BUILDING MATCH LINE - SEE DWG L207 15 1" = 30' 30 0 30'MATCH LINE - SEE DWG L2051 2 43 5 6 7 7 AMENITIES WORK *NO AMENITIES WORK *NO AMENITIES WORK *NO PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR PROPOSED STORM DRAINAGE PROPOSED AREA DRAIN FLOW DIRECTION LIMITS OF DISTURBANCE 200 200 GRADING LEGEND: LOD 6 AMENITIES GRADING & STORMWATER PLAN AREA 6 AREA 4 (NO AMENITIES WORK) R. MASSEY N/A C. CROSBY C. CROSBY R. MASSEY 37883790LODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLO D LO D LO D LO D LO D LO D LODLOD LOD LOD LODLODLODLODLODLODLODLODLODLOD3790379437953796 3797 3798 3799 3800 3801 3802 38033802380138003799379837 9 1 (379 2 ) (379 3 ) (3794) (3795 ) ( 3 7 9 6 ) ( 3 7 9 7 )(3798)(3799 )(3800)TW 3794 BW 3790.40 TW 3794 BW 3790.90 TW 3794 TW 3795.50 BW 3791.15 TW 3796.50 BW 3791.45 TW 3797.50 BW 3791.75 TW 3798.50 BW 3791.95 TW 3799.50 BW 3793.15 TW 3800.50 BW 3794.20 TW 3802.50 BW 3798.75 TW 3801.50 BW 3795.75 TW 3803.67 TW 3802.17 TW 3802.02 TW 3800.52 TW 3800.37 TW 3799.87 TW 3799.02 BW 3797.35 TW 3799.17 TW 3799.67 TW 3799.77 TW 3801.77 TW 3800.77 PLOT DATE: 7/4/2019 8:44 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-C500 STORMWATER PLAN Saved by CLANDOLL Save date: 7/4/2019 7:48 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: SCALE: 1" = 10' PLAN 5 1" = 10' 10 0 10' 1 2 43 5 6 7 7 AMENITIES WORK *NO AMENITIES WORK *NO AMENITIES WORK *NO PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR PROPOSED STORM DRAINAGE PROPOSED AREA DRAIN FLOW DIRECTION LIMITS OF DISTURBANCE 200 200 GRADING LEGEND: LOD 6 AMENITIES GRADING & STORMWATER PLAN AREA 6 ENLARGEMENT L206.1 R. MASSEY N/A J. WARNER J. WARNER R. MASSEY LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLO D LO D LOD LOD LOD LOD LOD L O D LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD 3793 PROVIDE 2% CROSS SLOPE ON ALL TRIALS 2%2%37903793LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLO D L O D LODLODLODLODLODLOD LODLODLODLOD LOD LOD LOD LOD LODLODLODLODLOD379437913792PROVIDE 2% CROSS SLOPE ON ALL TRIALS 2%PLOT DATE: 7/4/2019 8:45 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-C500 STORMWATER PLAN Saved by CLANDOLL Save date: 7/4/2019 7:48 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: L207 15 1" = 30' 30 0 30' SCALE: 1"=30' PLAN MATCH LINE - SEE DWG L205 MATCH LINE - SEE THIS SHEET MATCH LINE - SEE THIS SHEET 1 2 43 5 6 7 7 AMENITIES WORK *NO AMENITIES WORK *NO AMENITIES WORK *NO PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR PROPOSED STORM DRAINAGE PROPOSED AREA DRAIN FLOW DIRECTION LIMITS OF DISTURBANCE 200 200 GRADING LEGEND: LOD 7 7 AMENITIES GRADING & STORMWATER PLAN AREA 7 R. MASSEY N/A J. WARNER J. WARNER R. MASSEY TRAILS TRAILS LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODL O D L O D LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLOD LODLODLOD LOD LODLODLOD LODLODLOD LODLODL O D L O D LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD L O D LO D 4'-8"10'-7"88°BRIDGE 5 ALL B501 PLOT DATE: 7/4/2019 8:46 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-L300 LAYOUT PLAN Saved by CLANDOLL Save date: 7/4/2019 7:49 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: N/A C. LANDOLL J. WARNER J. WARNER C. LANDOLL 15 1" = 30' 30 0 30' SCALE: 1"=30' PLAN 1 2 43 5 6 7 7 AMENITIES WORK *NO AMENITIES WORK *NO AMENITIES WORK *NO 2 LAYOUT PLAN AREA 2 AMENITIES AREA 3 (NO AMENITIES WORK) AREA 1 (NO AMENITIES WORK) L302 LODL O D L O D L O D LODLOD LOD LO D LODLOD LOD LOD LOD LODLODLODLODLODLODLODLOD LOD LOD LODLODLODLODLODLODLODLODLODLODLOD LOD LODLODLODLODLODLODLODLODLODLODLODLOD LOD LODLODLODLODLODLODLODR42.6'R49.5' 5' R30.5' 6' R97.0' R59.0' R278.0' R22.0' R97.0' R17.0'R28.0' 6' R22.2' BRIDGE 4 BUILDING BRIDGE 3 R3.0' R3.0'R20.0'R5.5'6'-6"BUILDING BUILDING BUILDING CONTRACTOR TO FIELD LOCATE PATH ALIGNMENT FOR REVIEW BY LANDSCAPE ARCHITECT PRIOR TO INSTALLATION R4.0' 5' R34.3' R133.0' ALL B401 ALL B301 PLOT DATE: 7/4/2019 8:46 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-L300 LAYOUT PLAN Saved by CLANDOLL Save date: 7/4/2019 7:49 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: N/A C. LANDOLL J. WARNER J. WARNER C. LANDOLL 15 1" = 30' 30 0 30' SCALE: 1"=30' PLAN MATCH LINE - SEE DWG L307MATCH LINE - SEE DWG L3061 2 43 5 6 7 7 AMENITIES WORK *NO AMENITIES WORK *NO AMENITIES WORK *NO 5 LAYOUT PLAN AREA 5 AMENITIES AREA 3 (NO AMENITIES WORK)AREA 4 (NO AMENITIES WORK) L305 LOD LOD LOD LO D L O D LO D LOD LODLODLODLODLOD LODLODLODLODLODLOD LOD LODLODLODLODLODL O D L O D LODLODLODLODLODLODLODLODLODLOD LO D LO D LOD LODLODLODLODLODLODLODLOD LODLODLODLODLODLODLODL O D L O D L O D LODLODLODR22.2' 6'-6" BRIDGE 3 6'-6"BRIDGE 2 R40.0' R23.3' EX. CLUB HOUSE R34.3' R133.0' ALL B301 ALL B201 CONCRETE RETAINING WALL 2 W100 1 W100 CONCRETE RETAINING WALL 3 W100 CONCRETE RETAINING WALL EVENT LAWN DIMENSIONS, SEE ENLARGEMENT, SHEET L306.1 PLOT DATE: 7/4/2019 8:46 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-L300 LAYOUT PLAN Saved by CLANDOLL Save date: 7/4/2019 7:49 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: R. MASSEY C. LANDOLL J. WARNER J. WARNER C. LANDOLL 15 1" = 30' 30 0 30' SCALE: 1"=30' PLAN MATCH LINE - SEE DWG L307MATCH LINE - SEE DWG L3051 2 43 5 6 7 7 AMENITIES WORK *NO AMENITIES WORK *NO AMENITIES WORK *NO 6 LAYOUT PLAN AREA 6 AMENITIES AREA 4 (NO AMENITIES WORK) L306 LODLODLODLODLOD LODLODLODLODLODLODLODLODLOD LOD LOD LODLODLODLODLODLODLODLODL O D L O D LODLODLODLODLODLODLODLODLODLODLOD LO D LO D LO D LODLOD LODLODLODLODLODLODLODLODLODLODR56.0'R9.0'4'-11"R21.3' R64.0' R49.8' R 5 5 . 3 '4'8'R41.0' R69.0' R99.0' R12.3'27'-4"43'17'-112"5'-312"R10.0'8'-512"8' - 3 "R40.0'12'6'R2 8 . 0 ' R1.0' R1.0' R1.0' R6.2' 7' 1' 6' 8'6'-112"R43.0' 11'-7"6'3'-5 1 2 "R43.0'2'-2" 4'-111 2"R98.9'1'-2" R43. 0' R37.0'4'-9"6'-6"23'-1112"84'-51 2" TO BLDG POINT A 22'-10"TO BLDGPOINT AEVENT LAWN CNTR POINT 1 BLDG POINT A R 2 5 . 0 ' BLDG POINT B 38'-71 2" TO BLDG POINT B 1012" TO BLDGPOINT B21'-9" TO WALL2 CNTR POINT 112'-2" TO WALL 2 CNTR POINT 1 EVENT LAWN CNTR POINT 2 8'-1112"103'-11 2" TO WALL 2 CNTR POINT 1 16' TO WALL 2CNTR POINT 1WALL 2 CNTR POINT 2 WALL 1 CNTR POINT 2 WALL 1 CNTR POINT 1 83'-8" TO BLDG POINT A 27'-112" TOBLDG POINT A167' TO WALL 1 CNTR POINT 2 18'-2" TO WALL 1CNTR POINT 248'-512" TO BLDG POINT A3'-9" TO BLDG POINT A WALL 2 CNTR POINT 316°130° 51° WALL 2 CNTR POINT 1 77°60°96°WALL 3 CNTR POINT 19'-5" TO BLDG POINT B 5'-2" TO BLDGPOINT B7'PLOT DATE: 7/4/2019 8:46 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-L300 LAYOUT PLAN Saved by CLANDOLL Save date: 7/4/2019 7:49 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: R. MASSEY C. LANDOLL J. WARNER J. WARNER C. LANDOLL 10 20'020 1" = 20' SCALE: 1"=20' PLAN MATCH LINE - SEE DWG L307MATCH LINE - SEE DWG L3051 2 43 5 6 7 7 AMENITIES WORK *NO AMENITIES WORK *NO AMENITIES WORK *NO 6 LAYOUT PLAN AREA 6 ENLARGMENT AMENITIES AREA 4 (NO AMENITIES WORK) L306.1 LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLO D LO D LOD LOD LOD LOD LOD L O D LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD 6' WIDE PATH (TYP.) PATH FOLLOWS EXISTING GRASS PATH LOCATION, CONTRACTOR TO FIELD LOCATE PATH ALIGNMENT FOR REVIEW BY LANDSCAPE ARCHITECT PRIOR TO INSTALLATION LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLO D L O D LODLODLODLODLODLOD LODLODLODLOD LOD LOD LOD LOD LODLODLODLODLOD6' WIDE PATH (TYP.) 6' PATH FOLLOWS EXISTING GRASS PATH LOCATION, CONTRACTOR TO FIELD LOCATE PATH ALIGNMENT FOR REVIEW BY LANDSCAPE ARCHITECT PRIOR TO INSTALLATION BUILDING PLOT DATE: 7/4/2019 8:47 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-L300 LAYOUT PLAN Saved by CLANDOLL Save date: 7/4/2019 7:49 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: R. MASSEY C. LANDOLL J. WARNER J. WARNER C. LANDOLL 15 1" = 30' 30 0 30' SCALE: 1"=30' PLAN 1 2 43 5 6 7 7 AMENITIES WORK *NO AMENITIES WORK *NO AMENITIES WORK *NO MATCH LINE - SEE DWG L305 MATCH LINE - SEE THIS SHEET MATCH LINE - SEE THIS SHEET 7 LAYOUT PLAN AREA 7 AMENITIES L307 PLOT DATE: 7/4/2019 8:48 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-L400 PLANTING PLAN Saved by JWARNER Save date: 7/3/2019 5:41 PM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: TREES CODE QTY BOTANICAL / COMMON NAME CONT HEIGHT REMARKS AMLA 5 Amelanchier laevis Allegheny Serviceberry b & b 5` MIN.Multi-trunk COFL 3 Cornus florida Eastern Dogwood b & b 6` MIN. SHRUBS CODE QTY BOTANICAL / COMMON NAME CONT REMARKS ARAR 71 Aronia arbutifolia Red Chokeberry 5 gal CAFL 53 Calycanthus floridus Sweet Shrub 5 gal CEAM 56 Ceanothus americanus New Jersey Tea 5 gal ILGS 46 Ilex glabra `Shamrock` Inkberry 5 gal LEFR 79 Leucothoe fontanesiana `Rainbow` Rainbow Leucothoe 3 gal RHMA 13 Rhododendron maximum `Roseum` Rhododendron 5 gal SACA 50 Sambucus canadensis `Adams` Adams Elder 5 gal 36-48" HT GRASSES CODE QTY BOTANICAL / COMMON NAME CONT SPACING REMARKS ANVI 260 Andropogon virginicus Broomsedge Bluestem 18 per tray 36" o.c.18s liners available from Hoffman Nursery. SCSB 443 Schizachyrium scoparium `Blue Heaven` Blue Heaven Little Bluestem 18 per tray 36" o.c.18s liners available from Hoffman Nursery. Alternate varieties must be approved by landscape architect; variety must remain consistent within each planting zone. SONU 223 Sorghastrum nutans Indian Grass 18 per tray 36" o.c.18s liners available from Hoffman Nursery. Species preferred, varieties `Sioux Blue` and `Indian Steel` may be added. Variety should remain consistent within each planting area. PERENNIALS CODE QTY BOTANICAL / COMMON NAME CONT SPACING REMARKS ACRA 165 Actaea racemosa Black Cohosh 1 gal 24" o.c. ASIN 198 Asclepias incarnata Swamp Milkweed 1 gal 24" o.c. ASTU 149 Asclepias tuberosa Butterfly Milkweed 1 gal 18" o.c. CHGL 191 Chelone glabra White Turtle-head 1 gal 24" o.c. EUFI 252 Eupatorium fistolosum Joe Pye Weed 1 gal 36" o.c. GEMA 281 Geranium maculatum Spotted Geranium 1 quart 18" o.c.Species preferred, `Espresso` variety acceptable. HEAU 190 Helenium autumnale Sneezeweed 1 gal 24" o.c. HEHE 40 Heliopsis helianthoides False Sunflower 1 gal 36" o.c. HEAM 101 Heuchera americana American Alumroot 1 gal 18" o.c.Species preferred. `Green Spice` variety acceptable. LOCA 66 Lobelia cardinalis Cardinal Flower 1 gal 24" o.c. LOSI 230 Lobelia siphilitica Great Lobelia 1 gal 24" o.c. OEFR 172 Oenothera fruticosa Golden Sundrops 1 quart 18" o.c. PYMU 376 Pycnanthemum muticum Clustered Mountainmint 1 gal 24" o.c. SORF 299 Solidago rugosa `Fireworks` Wrinkleleaf Goldenrod 1 gal 24" o.c. SYNA 154 Symphyotrichum novae-angliae New England Aster 1 gal 24" o.c. PLANT SCHEDULE 1.VERIFY ALL QUANTITIES AND REPORT ANY DISCREPANCIES OR INACCURACIES IN THE PLANS TO THE OWNER'S REPRESENTATIVE PRIOR TO PLANTING. 2.LANDSCAPE WORK SHALL INCLUDE THE FURNISHING, INSTALLATION, AND WARRANTY OF ALL PLANTING MATERIALS WITHIN THE PROJECT AREA. 3.THE LANDSCAPE CONTRACTOR SHALL ASCERTAIN THE LOCATION OF ALL EXISTING AND NEW UNDERGROUND UTILITIES PRIOR TO EXCAVATION FOR PLANTING. DAMAGES TO UTILITIES CAUSED BY THE LANDSCAPE OPERATION SHALL BE CORRECTED BY THE LANDSCAPE CONTRACTOR AT NO COST TO THE OWNER. 4.LANDSCAPING SHALL REMAIN CLEAR FROM ANY FIRE HYDRANTS ON THE SITE. 5.ALL TREES TO BE A MINIMUM OF 2" IN CALIPER AND MUST MEET THE AMERICAN STANDARD FOR NURSERY STOCK. 6.TREE PROTECTION NOTE: TREE PROTECTION FENCING MUST BE IN PLACE PRIOR TO ANY DEMOLITION, LAND DISTURBANCE OR ISSUANCE OF A GRADING PERMIT AND SHALL INCLUDE WARNING SIGNS POSTED IN BOTH ENGLISH AND SPANISH, AS FOLLOWS: "NO TRESPASSING/TREE PROTECTION AREA/PROHIBIDO ENTRAR / ZONA PROTECTORA PARA LOS ÁRBOLES." 7.PROTECTION OF EXISTING VEGETATION: AT THE START OF GRADING INVOLVING THE LOWERING OF EXISTING GRADE AROUND A TREE OR STRIPPING OF TOPSOIL, A CLEAN, SHARP, VERTICAL CUT SHALL BE MADE AT THE EDGE OF THE TREE SAVE AREA AT THE SAME TIME AS OTHER EROSION CONTROL MEASURES ARE INSTALLED. THE TREE PROTECTION FENCING SHALL BE INSTALLED ON THE SIDE OF THE CUT FARTHEST AWAY FROM THE TREE TRUNK AND SHALL REMAIN IN PLACE UNTIL ALL CONSTRUCTION IN THE VICINITY OF THE TREES IS COMPLETE. NO STORAGE OF MATERIALS, FILL, OR EQUIPMENT AND NO TRESPASSING SHALL BE ALLOWED WITHIN THE BOUNDARY OF THE PROTECTED AREA. 8.ROOT ZONE PROTECTION AREA: VARIES BASED ON LOCAL JURISDICTION HAVING AUTHORITY. CONTRACTOR SHALL COMPLY WITH LOCAL JURISDICTIONAL REQUIREMENTS. NO DISTURBANCE ALLOWED WITHIN THIS AREA. AREA MUST BE PROTECTED WITH BOTH TREE PROTECTION FENCING AND WARNING SIGNS. 9.SEED BED PREPARATION: ALL AREAS TO BE SEEDED ARE TO BE RECEIVE A MINIMUM OF 2" OF APPROVED TOPSOIL. ALL DEBRIS, ROCKS, ETC. LARGER THAN .5" ARE TO BE REMOVED. ALL LARGE CONCENTRATIONS OF GRAVEL & DEBRIS REGARDLESS OF SIZE ARE TO BE REMOVED PRIOR TO SEEDING OR PLANTING. 10.ALL PLANT BED AREAS ARE TO RECEIVE A MINIMUM OF 6" OF APPROVED TOPSOIL. 11.SOIL SHOULD BE TESTED AND AMENDED WITH LIME AND FERTILIZER FOR HARDWOOD TREES ACCORDING TO NCDA PROCEDURES. SCARIFY PLANT PIT WALLS. CONSULT LANDSCAPE ARCHITECT FOR ALTERNATE COMPLIANCE. 12.SHREDDED HARDWOOD MULCH 3" DEEP EXCEPT AT CROWN OF PLANT UNLESS OTHERWISE NOTED. FLARE AT CROWN SHOULD BE REVEALED. BACKFILL CONSISTS OF THOROUGHLY BROKEN UP NATIVE SOIL. TOTAL VOLUME OF BACKFILL SHOULD BE AMENDED WITH UP TO ONE THIRD PINE BARK MULCH. PIECES SHOULD BE NO LARGER THAN WHAT PASSES THROUGH A ONE INCH SCREEN. IF ADDITIONAL SOIL IS REQUIRED FOR BACKFILL DUE TO DETRIMENTAL SUBSOIL DRAINAGE CONDITIONS, USE SOIL SIMILAR TO EXISTING NATIVE SOIL. ADDITIONAL SOIL TO BE APPROVED BY LANDSCAPE ARCHITECT. MAXIMUM SAUCER HEIGHT IS 6 INCHES. 13.CONTRACTOR IS RESPONSIBLE FOR KEEPING THE TREE UPRIGHT AND PLUMB THROUGHOUT THE WARRANTY PERIOD. IF STABILIZATION IS NECESSARY SEE STAKING IN TREE DETAIL, ORANGE FLAGGING TAPE SHOULD BE ATTACHED TO SUPPORT WIRE. STAKING SHOULD BE REMOVED BY CONTRACTOR AT END OF ONE YEAR WARRANTY PERIOD OR AS DIRECTED BY GROUNDS MANAGEMENT. 14.USE "BIO-BARRIER" OR EQUIVALENT ACCORDING TO MANUFACTURER'S RECOMMENDATION FOR TREES THAT WILL BE PLANTED WITHIN 10' OF PAVEMENT 15.LANDSCAPING/C.O. STANDARDS NOTE: ALL LANDSCAPING MUST BE IN PLACE PRIOR TO REQUEST FOR A CERTIFICATE OF COMPLIANCE. PLAN NOTES: L400 1.DO NOT STAKE TREES EXCEPT WHERE SPECIFIED BY LANDSCAPE ARCHITECT. STAKING IS REQUIRED FOR TREES PLANTED ON SLOPES. 2.WHERE SEVERAL TREES WILL BE PLANTED CLOSE TOGETHER SUCH THAT THEY WILL LIKELY SHARE ROOT SPACE, TILL IN SOIL AMENDMENTS TO A DEPTH OF 4-6" OVER THE ENTIRE AREA. 3.FOR CONTAINER GROWN TREES, USE FINGERS OR SMALL HAND TOOLS TO PULL THE ROOTS OUT OF THE OUTER LAYER OF POTTING SOIL; THEN CUT OR PULL APART ANY ROOTS CIRCLING THE PERIMETER OF THE CONTAINER. 4.FOR FIELD GROWN TREES, CUT BURLAP, ROPE AND WIRE BASKET AWAY FROM TOP AND SIDES OF ROOT BALL. 5.THOROUGHLY SOAK THE TREE ROOT BALL AND ADJACENT PREPARED SOIL SEVERAL TIMES DURING THE FIRST MONTH AFTER PLANTING AND REGULARLY THROUGHOUT THE FOLLOWING TWO SUMMERS. 6.THE PLANTING PROCESS IS SIMILAR FOR DECIDUOUS AND EVERGREEN TREES. 7.DO NOT WRAP TRUNK; MARK NORTH SIDE OF TREE IN THE NURSERY AND LOCATE TO THE NORTH IN THE FIELD. 8.WIDTH OF PLANTING HOLE IS 3X ROOT BALL AT THE SURFACE, SLOPING TO 2X THE ROOT BALL DIAMETER AT THE DEPTH OF THE ROOT BALL. 9.TOP OF ROOTBALL TO BE RAISED 2-3 INCHES ABOVE EXISTING GRADE. 10.FOR B&B PLANTS, NATURAL FIBER BURLAP SHOULD BE TURNED DOWN BY 1/3 TOTAL HEIGHT OF ROOT BALL. PLASTIC FIBER BURLAP AND WIRE BASKETS SHOULD BE REMOVED TO 2/3'S OF TOTAL HEIGHT OF ROOT BALL. 11.BEFORE PLANTING, ADD 3-4" OF WELL COMPOSTED LEAVES, RECYCLED YARD WASTE OR OTHER COMPOST AND TILL INTO TOP 6" OF PREPARED SOIL. ADD COMPOST AT 20-35% BY VOLUME TO BACKFILL. 12.PERFORM PERCOLATION TEST FOR EACH TREE PIT TO CONFIRM THAT WATER DRAINS OUT OF THE SOIL. PROVIDE GRAVEL SUMP FILTER FABRIC & VENT PIPE IF DRAINAGE DOES NOT OCCUR WITHIN 24 HOURS. INCLUDE ALL SUMPS IN BASE BID. SHOULD SUMPS NOT BE NECESSARY AFTER PERCOLATION TEST, PROVIDE CHANGE ORDER DEDUCT TO OWNER. 13.IF PLANTING HOLES ARE DUG WITH A LARGE AUGER BREAKING DOWN THE SIDES WITH A SHOVEL CAN ELIMINATE GLAZING AND CREATE THE PREFERRED SLOPING SIDE. 14.UNLESS OTHERWISE SPECIFIED, TREES SHALL HAVE SINGLE LEADERS. TREES WITH 2 LEADERS WILL BE REJECTED. 15.DO NOT PLACE MULCH IN CONTACT WITH TRUNK. 16.USE STANDARD "GATOR" BAGS FOR WATERING TREES IN AREAS NOT UNDER IRRIGATION. INCORPORATE TERRA-SORB (OR EQUAL) AS PER MANUFACTURERS RECOMMENDATIONS, FOR AREAS NOT UNDER IRRIGATION. PLANTING NOTES: N/A C. LANDOLL J. WARNER J. WARNER C. LANDOLL PLANTING PLAN PLANT SCHEDULE & GENERAL NOTES AMENITIES LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODL O D L O D LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLOD LODLODLOD LOD LODLODLOD LODLODLOD LODLODL O D L O D LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD L O D LO D 3 8 1 1 3 8 1 0 3809 3808 38073808 38103 8 0 5 38003795379037883788380738083809381038113806380538003798(6) RHMA (6) RHMA PLOT DATE: 7/4/2019 8:48 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-L400 PLANTING PLAN Saved by JWARNER Save date: 7/3/2019 5:41 PM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: L402 15 1" = 30' 30 0 30' 1 2 43 5 6 7 7 AMENITIES WORK *NO AMENITIES WORK *NO AMENITIES WORK *NO SCALE: 1"=30' PLAN 2 N/A C. LANDOLL J. WARNER J. WARNER C. LANDOLL PLANTING PLAN AREA 2 AMENITIES 3 7 9 1 37 91 378837 9 0 37 8 8 37 9 3380037 9 5 3802LODL O D L O D L O D LODLOD LOD LO D LODLOD LOD LOD LOD LODLODLODLODLODLODLODLOD LOD LOD LODLODLODLODLODLODLODLODLODLODLOD LOD LODLODLODLODLODLODLODLODLODLODLODLOD LOD LODLODLODLODLODLODLOD379337943795379637973785379037953784378637873788378937913792379337943796378537903783378437863787378837893791 3792 378 5 378 4 37 9 5 37 9 0 37 8 8 37 9 5 3 7 9 0 3 7 8 8 38003 7 9 1 3 7 9 2 3 7 9 3 37 8 9 37 9 0 37 9 1 379 2 3793 379 43795 37 9 1 37 9 2 37 9 3 37 9 4 37 9 6 37 9 7 37 9 83799 379 0 3 7 9 5 3 8 0 0 378 8 37 8 9 3791379237933 7 9 4 3 7 9 6 3 7 9 7 3 7 9 8 3 7 9 9 380 1 38 0 2 3 8 0 3380538 0 1 380238033804379 0 3795 379137923793 3794 (8) CEAM (35) SORF (20) GEMA (13) SORF (13) SORF (10) GEMA (9) CEAM (2) EUFI (3) EUFI (26) GEMA (23) GEMA (39) ASTU (18) SCSB (34) HEAU (44) ASIN (86) SCSB (16) ANVI (70) HEAU (39) ANVI (86) OEFR (9) SACA (17) ARAR (5) AMLA (189) PYMU (63) SYNA (91) SYNA (4) CHGL (10) CHGL (29) EUFI (97) SCSB (35) SONU (8) CAFL (13) LEFR (10) ARAR (3) SACA (14) ASTU (33) CHGL (10) LOSI (31) ANVI (27) LOCA PLOT DATE: 7/4/2019 8:48 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-L400 PLANTING PLAN Saved by JWARNER Save date: 7/3/2019 5:41 PM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: MATCH LINE - SEE SHEET L407 MATCH LINE - SEE SHEET L406L405L405 15 1" = 30' 30 0 30' 1 2 43 5 6 7 7 AMENITIES WORK *NO AMENITIES WORK *NO AMENITIES WORK *NO SCALE: 1"=30' PLAN 5 N/A C. LANDOLL J. WARNER J. WARNER C. LANDOLL PLANTING PLAN AREA 5 AMENITIES 37 9 0 37 8 8 37 9 3 3 7 9 3 3 7 9 0 3 7 8 8 37883790LOD LOD LOD LO D L O D LO D LOD LODLODLODLODLOD LODLODLODLODLODLOD LOD LODLODLODLODLODL O D L O D LODLODLODLODLODLODLODLODLODLOD LO D LO D LOD LODLODLODLODLODLODLODLOD LODLODLODLODLODLODLODL O D L O D L O D LODLODLOD3790379437953796 3797 3798 3799 3800 3801 38023803 38033802380138003799379837 9 1 37 8 5 3790 3786 3787 3788 3789 3791 3792 379 3 3 7 8 5 3 7 9 0 3 7 8 4 3 7 8 6 37 8 7 3 7 8 8 3 7 8 9378537903783378437863787378837893791 3792 378 5 379 0 378 4 3786 3787 3788 3789 3791 3785 3790 3786 3787 378837893791 379 4 379537963797379837993 8 0 5 3810381538 0 6 3 8 0 7 3 8 0 8 3809381138123813381437853790379538003784378637873788378937913792379337943796379737983799380138023803380437 9 5 3 8 0 0 3 8 0 5 381038 1 5 37943 7 96 3 7 9 7 3 7 9 8 3 7 9 9 3801380238 0 3 38 0 4 380 6 3 8 0 7 38 08380 9 381138123813381438 1 6 (42) ILGS (4) CEAM (4) ILGS (3) CEAM (53) SORF (5) CAFL (15) HEHE (29) CHGL (43) GEMA (5) CEAM (1) SACA (5) ARAR (19) GEMA (1) COFL (11) CEAM (8) GEMA (11) GEMA (1) SACA (6) ARAR (6) CEAM (7) LEFR (20) EUFI (34) OEFR (1) RHMA (41) ACRA (31) HEAU (21) SCSB (42) PYMU (10) HEHE (27) LOSI (9) EUFI (13) ASIN (32) SCSB (28) CHGL (7) HEAM (33) CHGL (21) HEAM (33) HEAU (10) LEFR (19) EUFI (52) PYMU (50) HEAM (53) GEMA (98) ACRA (17) ACRA (23) HEAM (19) OEFR (15) OEFR (3) CEAM (35) SORF (7) CEAM (2) SACA (9) GEMA (23) ASIN (3) EUFI (21) LOSI (24) SORF (21) LOSI (18) OEFR (15) GEMA (11) EUFI (31) ASIN (26) CHGL (20) PYMU (1) COFL (9) ACRA (5) LEFR (1) SACA (11) SCSB (22) HEAU (32) PYMU (11) HEHE (23) LOSI (10) EUFI (12) ASIN (28) CHGL (41) PYMU (63) LOSI (1) COFL (2) SACA (7) ARAR (9) SCSB (23) ANVI (6) ARAR (5) CAFL (13) LOSI (13) SORF (12) ASTU (12) ASTU (13) LEFR (4) ARAR (7) EUFI (1) SACA (39) ANVI (22) SCSB (15) SORF (9) CAFL (3) SACA (5) LEFR (7) ANVI (13) SONU (15) LOSI (10) LOSI (3) SACA (10) ARAR (7) SACA (5) CAFL (46) SONU (37) EUFI (19) SCSB (16) SCSB (17) SONU (38) ASTU (22) SORF (39) ASTU (18) SCSB (34) HEAU (70) HEAU (39) ANVI (86) OEFR (12) ANVI (3) SACA (19) ASIN (22) LOSI (13) LEFR (3) SACA (5) LOSI (43) EUFI (43) ANVI (26) ASIN (8) SACA (6) CAFL (9) CAFL (50) ANVI (30) ASIN (55) SORF (51) SCSB (21) SORF (34) ASTU (37) SCSB (39) LOCA (9) SACA (17) ARAR (5) AMLA (189) PYMU (53) EUFI (70) SONU(63) SYNA (91) SYNA (4) CHGL (10) CHGL (29) EUFI (97) SCSB (35) SONU (8) CAFL (13) LEFR (10) ARAR (3) SACA (14) ASTU (33) CHGL (10) LOSI (31) ANVI (27) LOCA (17) GEMA (6) ARAR (28) CHGL (42) SONU (6) EUFI (7) LEFR (6) LEFR PLOT DATE: 7/4/2019 8:48 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-L400 PLANTING PLAN Saved by JWARNER Save date: 7/3/2019 5:41 PM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT:MATCH LINE - SEE SHEET L405MATCH LINE - SEE SHEET L407 L406 15 1" = 30' 30 0 30' 1 2 43 5 6 7 7 AMENITIES WORK *NO AMENITIES WORK *NO AMENITIES WORK *NO SCALE: 1"=30' PLAN 6 N/A C. LANDOLL J. WARNER J. WARNER C. LANDOLL PLANTING PLAN AREA 6 AMENITIES LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLO D LO D LOD LOD LOD LOD LOD L O D LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD 3793 37813790379537873788378937913792379337943796 3793 37 9 4 3 7 9 5 37 9 6 37 9 7 3 7 9 8 379 2 3791 3790 3789 3 7 8 8 3787378637 8 5379037883789379137923793 37903793LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLO D L O D LODLODLODLODLODLOD LODLODLODLOD LOD LOD LOD LOD LODLODLODLODLOD3794379137923782378337843785 37903786378737883789379137803785379037883791379237933794379537963792379337943795 (11) SCSB (5) SCSB (8) SCSB (4) HEHE PLOT DATE: 7/4/2019 8:49 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-L400 PLANTING PLAN Saved by JWARNER Save date: 7/3/2019 5:41 PM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: MATCH LINE - SEE SHEET L405 MATCH LINE - THIS SHEET MATCH LINE - THIS SHEET L407L407 15 1" = 30' 30 0 30' 1 2 43 5 6 7 7 AMENITIES WORK *NO AMENITIES WORK *NO AMENITIES WORK *NO SCALE: 1"=30' PLAN 7 7 N/A C. LANDOLL J. WARNER J. WARNER C. LANDOLL PLANTING PLAN AREA 7 AMENITIES FINISH COURSE ASPHALT. CABC, NO.7 TYP. COMPACTED SUBGRADE TYP. 2" 6" FLAGSTONE, PATTERN AND SIZING TO PATCH EXISTING PATIO CIP CONCRETE SLAB COMPACTED AGGREGATE BASE COURSE 1/4" MORTARED JOINT COMPACTED SUBGRADE.1 - 1 12"MORTAR SETTING BED34"4"6"2"FINISH COURSE ASPHALT. BASE COURSE ASPHALT. CABC, NO.7 TYP. COMPACTED SUBGRADE TYP. 8" 212" 1" 12" ALUMINUM STAKES TO LOCK INTO PERFORATED LOOPS ON THE EDGING 4" THICK GRANITE SCREENINGS 4" COMPACTED AGGREGATED BASE COURSE COMPACTED SUBGRADE. 6" ALUMINUM EDGING COMPACTED SUBGRADE 4,500 PSI CONCRETE WITH SAWCUT JOINTS, BROOM FINISH. PAVING JOINTS (TYP.), SEE ENLARGEMENTS 5" 4" 4" COMPACTED ABC BASE COBBLE, SALVAGED ON-SITE, AVG. 18" DEPTH ISLAND SLOPE GEOTEXTILE COMPACTED SUBGRADE. NOTES: 1.REFER TO L302 FOR LAYOUT AND SPACING OF JOINTS. 2.EXPANSION JOINTS SHALL OCCUR AT ALL AREAS WHERE PAVEMENT MEETS WALLS / VERTICAL SURFACE AND AT ALL COLD JOINTS. SAWCUT EXISTING CONCRETE PAVING, SEE PLAN PREMOLDED ASPHALT IMPREGNATED FIBER, FULL DEPTH WITH BACKER ROD AND JOINT SEALANT. (RECESSED 1 4") 1 4" W @ 4" CONCRETE 1 2" W @ 8" CONCRETE EXPANSION JOINT CABC BASE (TYP.) COMPACTED SUBGRADE (TYP.) 6" SQ. GREASED PLATE DOWEL @ 24" O.C. EQ. EQ. CONCRETE PAVING 1/8" WIDE CONTROL JOINT, SAWCUT (SEE PLANS FOR LOCATIONS). JOINT DEPTH EQUAL TO 1 4 OF THE DEPTH OF CONCRETE. PAVING JOINT PJ1 CABC BASE COMPACTED SUBGRADE CONCRETE PAVING PLOT DATE: 7/4/2019 8:50 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-L500 SITE DETAILS Saved by CLANDOLL Save date: 7/4/2019 8:29 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: SECTION ASPHALT PAVING - HEAVY DUTY = 1'-0"3 4"ASPHALT PAVING - LIGHT DUTY MORTARED STONE PAVING STONE SCREENING SECTION SECTION SECTION = 1'-0"3 4"= 1'-0"1 12" = 1'-0"1 12" 2 3 4 N/A C. LANDOLL J. WARNER M. LIN C. LANDOLL L500 SECTION CONCRETE PAVING = 1'-0"3 4"6RIVER ROCK APRON SECTION = 1'-0"1 12"5 SITE DETAILS AMENITIES 1 = 1'-0"3"EXPANSION JOINT:= 1'-0"3"CONTROL JOINT: ALIGN TOP OF RAIL AND POST AND PROVIDE CONTINUOUS WELD (TYP.) GRIND SMOOTH NOTES: 1.SEE MATERIALS AND FURNISHINGS MATCH EXISTING STEEL HANDRAIL 2.3" SQ. ESCUTCHEON PLATE TO BE INSTALLED AT BASE OF EACH RAILING POST. INSTALL USING BASE PLATE AND SET SCREWS. COLOR, MATERIAL, AND FINISH TO MATCH RAILING. 3.EMBEDDED MOUNT (TYP.) 4.ALIGN TOP OF RAIL AND POST AND PROVIDE CONTINUOUS WELD (TYP.) GRIND SMOOTH CONTRACTOR TO PROVIDE SHOP DRAWINGS OF EMBED DEPTH. DECORATIVE STEEL TOPRAIL, CONTINUOUS FINISH TO MATCH EXISTING 4' TYP. CONTRACTOR FIELD VERIFY 3'2'1'2" SQ. TUBE STEEL POST, FINISH TO MATCH EXISTING 3'4' TYP. STEEL HANDRAIL EXPANSION JOINT, TYP. COMPACTED SUBGRADE 6" DIA.SLEEVE & NON-SHRINK GROUT. MIN. 2FT. DEPTH, TYP. 6X6X6 6 W.W.W. (2)#4 CONTINOUS, TYP. #4 @ 16" O.C., YTP. STONE PAVERS, SEE L500 SEE STAIR ENLARGEMENT 8"14"20"6"CONCRETE WALL W/ STONE VENEER, LOCATIONS VARY, SEE PLAN. SEE STRUCTURAL SHEETS FOR DETAILS. 1'-1" 1" OVERHANG, TYP. STONE RISER, HONED FINISH, SEE MATERIAL SHEET NATURAL STONE TREAD, SEE MATERIAL SHEET 3" STAINLESS STEEL DOWEL 1/4" BULLNOSE EDGE6"NOTES: CONTRACTOR TO COORDINATE WITH LANDSCAPE ARCHITECT PRIOR TO CONSTRUCTION FOR BOULDER SELECTION AND PLACEMENT COMPACT SUBGRADE NATURAL STONE BOULDER 18"-36" TYP.36"-60" TYP. BURIED 13 DEPTH PLOT DATE: 7/4/2019 8:50 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-L500 SITE DETAILS Saved by CLANDOLL Save date: 7/4/2019 8:29 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: SECTION STEEL HANDRAIL = 1'-0"3 4" 2 N/A C. LANDOLL J. WARNER M. LIN C. LANDOLL L501 = 1'-0"3 4" ELEVATION = 1'-0"3" STONE STAIR SECTION = 1'-0"3 4"3 SITE DETAILS AMENITIES SECTION:ELEVATION: , ENLARGEMENT: SECTION BOULDER = 1'-0"3 4"1 PLOT DATE: 7/4/2019 8:50 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-L600 STORMWATER DETAILS Saved by CLANDOLL Save date: 7/4/2019 7:53 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: SECTION CONCRETE DROP INLET DETAIL NTS DROP INLET FRAME AND GRATE DETAIL DRAINAGE STRUCTURE STEPS FLEXIBLE PIPE INSTALLATION DETAIL ELEVATION ELEVATION SECTION NTS = 1'-0"3 4" NTS 1 2 3 4 R. MASSEY N/A C. CROSBY C. CROSBY R. MASSEY L600 STORMWATER DETAILS AMENITIES PLOT DATE: 7/4/2019 8:50 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-L600 STORMWATER DETAILS Saved by CLANDOLL Save date: 7/4/2019 7:53 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: R. MASSEY C. LANDOLL J. WARNER J. WARNER C. LANDOLL L601 STORMWATER DETAILS AMENITIES1.50' PLANTING SOILGEOTEXTILE 1.00' MINFREE DRAINING ANGULAR WASHED STONE 3 4" - 2" DIAMETER INSTALLED AT MINIMUM COMPACTION OF 95% PLANTING SOIL 2 TYPICAL UNDERDRAIN CLEANOUT NTS SECTION 4" PVC FINISHED GRADEWATER TIGHT CLEAN OUT WITH BRASS CAP FLUSH WITH FINISHED GRADE 1.0' EXTENSION WITH PERMANENT PLUG CAP COMBINATION LONG TURN PATTERN Y AND 1 8" BEND BARREL OF PIPE TO REST ON WASHED #57 STONE 6" PERFORATED HDPE UNDERDRAIN @0.50% SLOPE WITH 3 8" HOLES 6" ON CENTER EVERY 90 DEGREES. 1 LAWN UNDERDRAIN DETAIL NTS TURN REINFORCEMENT GEOTEXTILE COMPACTED SUBGRADEADVANEDGE END OUTLET OR SIMILAR (BY OTHERS) 6" PERFORATED PVC, SEE DETAIL THIS SHEET 8" HDPE SOLID WALL UNDER DRAIN COLLECTOR NON WOOVEN FILTER FABRIC TRUNK CALIPER SHALL MEET ANSI Z60 CURRENT EDITION FOR ROOT BALL SIZE. MODIFIED SOIL. DEPTH VARIES. (SEE PLANT SOIL PLAN). FINISHED GRADE. BOTTOM OF ROOT BALL RESTS ON EXISTING OR RECOMPACTED SOIL. CENTRAL LEADER. (SEE CROWN OBSERVATIONS DETAIL). ROUND-TOPPED SOIL BERM 4" HIGH X 8" WIDE ABOVE ROOT BALL SURFACE SHALL BE CONSTRUCTED AROUND THE ROOT BALL. BERM SHALL BEGIN AT ROOT BALL PERIPHERY. TOP OF ROOT BALL SHALL BE FLUSH WITH FINISHED GRADE. PRIOR TO MULCHING, LIGHTLY TAMP SOIL AROUND THE ROOT BALL IN 6" LIFTS TO BRACE TREE. DO NOT OVER COMPACT. WHEN THE PLANTING HOLE HAS BEEN BACKFILLED, POUR WATER AROUND THE ROOT BALL TO SETTLE THE SOIL. 3" LAYER OF SETTLED MULCH. NO MORE THAN 1" OF MULCH ON TOP OF ROOT BALL. (SEE SPECIFICATIONS FOR MULCH). SCARIFIED SOIL. EQUAL EQUALEQUAL ROOT BALL MODIFIED AS REQUIRED (SEE SPECIFICATIONS). 4" Ø SOCK DRAIN CONTINUOUS AROUND BASE OF TREE. INSTALL 4" - 6" DEEPER THAN ROOT BALL FOR LOWERED PLANTING HOLE AS NEEDED WITH POOR DRAINAGE (SEE PLANTING PIT/BED DRAIN DETAIL). TRUNK CALIPER SHALL MEET ANSI Z60 CURRENT EDITION FOR ROOT BALL SIZE. ROUND-TOPPED SOIL BERM 4" HIGH X 8" WIDE ABOVE ROOT BALL SURFACE ON THE DOWNHILL SIDE OF THE ROOT BALL. BERM SHALL DIE INTO SLOPE. FINISHED GRADE (MAX SLOPE SHALL BE 3:1). BOTTOM OF ROOT BALL RESTS ON EXISTING OR RECOMPACTED SOIL (SEE NOTE 8). CENTRAL LEADER. (SEE CROWN OBSERVATIONS DETAIL). FINISHED SLOPE SHOULD PASS THROUGH THE POINT WHERE THE TRUNK BASE MEETS SUBSTRATE/SOIL. 3" LAYER OF SETTLED MULCH. NO MORE THAN 1" OF MULCH ON TOP OF ROOT BALL. (SEE SPECIFICATIONS FOR MULCH). MODIFIED SOIL. DEPTH VARIES. (SEE SOIL PREPARATION PLAN). ROOT BALL MODIFIED AS REQUIRED (SEE SPECIFICATIONS). PRIOR TO MULCHING, LIGHTLY TAMP SOIL AROUND THE ROOT BALL IN 6" LIFTS TO BRACE TREE. DO NOT OVER COMPACT. WHEN THE PLANTING HOLE HAS BEEN BACKFILLED, POUR WATER AROUND THE ROOT BALL TO SETTLE THE SOIL. EQUAL EQUALEQUAL 4" Ø SOCK DRAIN CONTINUOUS AROUND BASE OF TREE. INSTALL 4" - 6" DEEPER THAN ROOT BALL FOR LOWERED PLANTING HOLE AS NEEDED WITH POOR DRAINAGE (SEE PLANTING PIT/BED DRAIN DETAIL). MODIFIED SOIL. DEPTH VARIES. (SEE PLANTING SOIL PLAN). 4" HIGH X 8" WIDE ROUND - TOPPED SOIL BERM ABOVE ROOT BALL SURFACE SHALL BE CONSTRUCTED AROUND THE ROOT BALL. BERM SHALL BEGIN AT ROOT BALL PERIPHERY. PRIOR TO MULCHING, LIGHTLY TAMP SOIL AROUND THE ROOT BALL IN 6" LIFTS TO BRACE SHRUB. DO NOT OVER COMPACT. WHEN THE PLANTING HOLE HAS BEEN BACKFILLED, POUR WATER AROUND THE ROOT BALL TO SETTLE THE SOIL. 3" LAYER OF SETTLED MULCH. NO MORE THAN 1" OF MULCH ON TOP OF ROOT BALL. (SEE SPECIFICATIONS FOR MULCH). ROOT BALL RESTS ON EXISTING OR RECOMPACTED SOIL. SCARIFIED SOIL. FINISHED GRADE. ROOT BALL 3" LAYER OF SETTLED MULCH. NO MORE THAN 1" OF MULCH ON TOP OF ROOT BALL. (SEE SPECIFICATIONS FOR MULCH). PRIOR TO MULCHING, LIGHTLY TAMP SOIL AROUND THE ROOT BALL IN 6" LIFTS TO BRACE SHRUB. DO NOT OVER COMPACT. WHEN THE PLANTING HOLE HAS BEEN BACKFILLED, POUR WATER AROUND THE ROOT BALL TO SETTLE THE SOIL. ORIGINAL SLOPE SHOULD PASS THROUGH THE POINT WHERE THE TRUNK MEETS SUBSTRATE/SOIL. MODIFIED SOIL. DEPTH VARIES. (SEE PLANTING SOIL PLAN). BOTTOM OF ROOT BALL RESTS ON EXISTING OR RECOMPACTED SOIL. SCARIFIED SOIL. ROOT BALL SECTION VIEW PAVEMENT. MULCH. GROUNDCOVER PLANTS TO BE TRIANGULARLY SPACED. SCARIFIED SOIL. 6" - 8" MODIFIED SOIL. DEPTH VARIES. (SEE SPECIFICATIONS FOR SOIL MODIFICATION). 3" LAYER OF SETTLED MULCH. FINISHED GRADE. EQ U A L EQUAL CURB OR EDGE OF PAVEMENT. INDIVIDUAL PLANT SPACING 'X'. REFER TO PLANT LIST FOR SPACING EXCEPT WHERE NOTED MASSES TO USE TRIANGULAR ALL SHRUBS AND GROUNDCOVER NOTE: PLANT TYPES. BETWEEN DIFFERENT PROVIDE MIN. 18" SPACING 'X' 'X''X'12"6"18"MIN24"18"SETBACK FOR 36" O.C. SETBACK FOR 24" O.C. SETBACK FOR 48" - 60" O.C. SETBACK FOR 6" O.C. NOTES: 1.SEE PLANTING LEGEND FOR GROUNDCOVER SPECIES, SIZE AND SPACING DIMENSION. 2.SMALL ROOTS (14" OR LESS) THAT GROW AROUND, UP OR DOWN THE ROOT BALL PERIPHERY ARE CONSIDERED A NORMAL CONDITION IN CONTAINER PRODUCTION AND ARE ACCEPTABLE, HOWEVER THEY SHOULD BE ELIMINATED AT THE TIME OF PLANTING. ROOTS ON THE PERIPHERY CAN BE REMOVED AT THE TIME OF PLANTING (SEE ROOT BALL SHAVING DETAIL). 3.SETTLE SOIL AROUND ROOT BALL OF EACH GROUNCOVER PRIOR TO MULCHING. 4.WHEN GROUNDCOVER PLANTINGS ARE USED IN MASSES, ENTIRE BED SHALL BE EXCAVATED AND TILLED WITH SOIL AMENDMENTS PER SPECIFICATIONS. 5.CONTRACTORS SHALL ASSURE PERCOLATION OF A ALL PLANTING PITS PRIOR TO INSTALLATION.PLOT DATE: 7/4/2019 8:51 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-L900 PLANTING & SOILS DETAILS Saved by CLANDOLL Save date: 7/4/2019 7:51 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: SECTION TREE (TYPICAL)NTS TREE ON SLOPE (TYPICAL)SHRUB (TYPICAL) GROUNDCOVER PLANTING (TYPICAL)SHRUB ON SLOPE (TYPICAL) SECTION SECTION SECTION PLAN NTS NTS NTS 1 2 3 4 6 NTSSHRUB AND GROUNDCOVER SPACING SECTION NTS5 L700 N/A C. LANDOLL J. WARNER J. WARNER C. LANDOLL PLANTING DETAILS AMENITIES PLOT DATE: 7/4/2019 8:51 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-L900 PLANTING & SOILS DETAILS Saved by CLANDOLL Save date: 7/4/2019 7:51 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: SECTION TREE STAKING - LODGE POLES NTS TREE STAKING ON SLOPE PERENNIAL PLANTING (TYPICAL) SECTION SECTION NTS NTS123 L701 32" LONG NON-ABRASIVE RUBBER TIES. PLAN VIEW - (3) LODGE POLES PLAN VIEW - (2) LODGE POLES 6'-0"2'-0"THREE (3") OR THREE (2") LODGE POLE STAKES. INSTALL APPROXIMATELY 2" AWAY FROM THE EDGE OF THE ROOT BALL. STAKE LOCATION SHALL NOT INTERFERE WITH PERMANENT BRANCHES. REMOVE NURSERY STAKE. IF CENTRAL LEADER NEEDS TO BE STRAIGHTENED OR HELD ERECT, IT IS ACCEPTABLE TO ATTACH A 12" x 8' BAMBOO POLE TO CENTRAL LEADER AND TRUNK. LODGE POLES RUBBER TREE TIES NOTES: 1.3 STAKES REQUIRED FOR 3" CALIPER OR LARGER TREE. 2.2 STAKES REQUIRED FOR 12' (HEIGHT) OR SMALLER. PERENNIAL PLANTINGS 4" TALL SOIL BERM NOTES: 1. FOR PERENNIAL BEDS, TILL TO A MINIMUM DEPTH OF 6". 2. CONTRACTOR SHALL ASSURE PERCOLATION OF ALL PLANTING PITS PRIOR TO INSTALLATION. 3. WHEN PERENNIALS ARE USED IN MASSES, ENTIRE BED SHALL BE EXCAVATED AND TILLED WITH SOIL AMENDMENTS PER SPECIFICATIONS.SUBSOIL PLANTING SOIL PLAN VIEW 1" x 9' SINGLE METAL STAKE WITH METAL ARM BAR SECURED TO STAKE AND RUBBER STRAP AROUND TRUNK. 1" x 9' SINGLE METAL STAKE. INSTALL PER MANUFACTURER'S SPECIFICATIONS AND RECOMMENDATIONS. STAKE LOCATION SHALL NOT INTERFERE WITH BRANCHES. REMOVE NURSERY STAKE. IF CENTRAL LEADER NEEDS TO BE STRAIGHTENED OR HELD ERECT, IT IS ACCEPTABLE TO ATTACH A 12" x 8' BAMBOO POLE TO THE CENTRAL LEADER AND TRUNK. PREVAILING WIND.7'2' 4 - 7'HEIGHT OF ARM BAR SHALL VARY PER TREE. CONTRACTOR TO ADJUST AS NEEDED TO HOLD TREE ERECT. N/A C. LANDOLL J. WARNER J. WARNER C. LANDOLL PLANTING DETAILS AMENITIES PLOT DATE: 7/4/2019 8:51 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-B100 BRIDGE PLANS Saved by CLANDOLL Save date: 7/4/2019 8:04 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: D. RUGGLES N/A V. CHUNG V. CHUNG D. RUGGLES B000 TYPICAL SECTIONS AND GENERAL NOTES BRIDGES PLOT DATE: 7/4/2019 8:51 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-B100 BRIDGE PLANS Saved by CLANDOLL Save date: 7/4/2019 8:04 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: B001 APPROACH AND RAIL DETAILS BRIDGESD. RUGGLES N/A V. CHUNG V. CHUNG D. RUGGLES PLOT DATE: 7/4/2019 8:52 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-B100 BRIDGE PLANS Saved by CLANDOLL Save date: 7/4/2019 8:04 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: B101 BRIDGE 1 - GENERAL BRIDGESD. RUGGLES N/A V. CHUNG V. CHUNG D. RUGGLES PLOT DATE: 7/4/2019 8:52 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-B100 BRIDGE PLANS Saved by CLANDOLL Save date: 7/4/2019 8:04 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: D. RUGGLES N/A V. CHUNG V. CHUNG D. RUGGLES B102 BRIDGE 1 - ABUTMENT 1 BRIDGES PLOT DATE: 7/4/2019 8:52 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-B100 BRIDGE PLANS Saved by CLANDOLL Save date: 7/4/2019 8:04 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: B103 BRIDGE 1 - ABUTMENT 2 BRIDGESD. RUGGLES N/A V. CHUNG V. CHUNG D. RUGGLES PLOT DATE: 7/4/2019 8:52 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-B100 BRIDGE PLANS Saved by CLANDOLL Save date: 7/4/2019 8:04 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: B104 BRIDGE 1 - ABUTMENT DETAILS BRIDGESD. RUGGLES N/A V. CHUNG V. CHUNG D. RUGGLES B201 PLOT DATE: 7/4/2019 8:52 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-B100 BRIDGE PLANS Saved by CLANDOLL Save date: 7/4/2019 8:04 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: B201 BRIDGE 2 - GENERAL BRIDGESD. RUGGLES N/A V. CHUNG V. CHUNG D. RUGGLES PLOT DATE: 7/4/2019 8:52 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-B100 BRIDGE PLANS Saved by CLANDOLL Save date: 7/4/2019 8:04 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: B202 BRIDGE 2 - ABUTMENT 1 BRIDGESD. RUGGLES N/A V. CHUNG V. CHUNG D. RUGGLES PLOT DATE: 7/4/2019 8:52 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-B100 BRIDGE PLANS Saved by CLANDOLL Save date: 7/4/2019 8:04 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: B203 BRIDGE 2 - ABUTMENT 2 BRIDGESD. RUGGLES N/A V. CHUNG V. CHUNG D. RUGGLES PLOT DATE: 7/4/2019 8:52 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-B100 BRIDGE PLANS Saved by CLANDOLL Save date: 7/4/2019 8:04 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: B204 BRIDGE 2 - ABUTMENT DETAILS BRIDGESD. RUGGLES N/A V. CHUNG V. CHUNG D. RUGGLES B301 PLOT DATE: 7/4/2019 8:52 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-B100 BRIDGE PLANS Saved by CLANDOLL Save date: 7/4/2019 8:04 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: B301 BRIDGE 3 - GENERAL BRIDGESD. RUGGLES N/A V. CHUNG V. CHUNG D. RUGGLES PLOT DATE: 7/4/2019 8:52 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-B100 BRIDGE PLANS Saved by CLANDOLL Save date: 7/4/2019 8:04 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: B302 BRIDGE 3 - ABUTMENT 1 BRIDGESD. RUGGLES N/A V. CHUNG V. CHUNG D. RUGGLES PLOT DATE: 7/4/2019 8:52 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-B100 BRIDGE PLANS Saved by CLANDOLL Save date: 7/4/2019 8:04 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: B303 BRIDGE 3 - ABUTMENT 3 BRIDGESD. RUGGLES N/A V. CHUNG V. CHUNG D. RUGGLES PLOT DATE: 7/4/2019 8:52 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-B100 BRIDGE PLANS Saved by CLANDOLL Save date: 7/4/2019 8:04 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: B304 BRIDGE 3 - ABUTMENT DETAILS BRIDGESD. RUGGLES N/A V. CHUNG V. CHUNG D. RUGGLES PLOT DATE: 7/4/2019 8:53 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-B100 BRIDGE PLANS Saved by CLANDOLL Save date: 7/4/2019 8:04 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: B305 BRIDGE 3 - TYPICAL PIER BRIDGESD. RUGGLES N/A V. CHUNG V. CHUNG D. RUGGLES PLOT DATE: 7/4/2019 8:53 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-B100 BRIDGE PLANS Saved by CLANDOLL Save date: 7/4/2019 8:04 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: B306 BRIDGE 3 - ALTERNATE PIER BRIDGESD. RUGGLES N/A V. CHUNG V. CHUNG D. RUGGLES PLOT DATE: 7/4/2019 8:53 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-B100 BRIDGE PLANS Saved by CLANDOLL Save date: 7/4/2019 8:04 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: B307 BRIDGE 3 - ALTERNATE CONCRETE PIER DETAILS AND BILL OF MATERIAL BRIDGESR. MASSEY J. MCSWAIN J. WARNER J. WARNER C. LANDOLL B401 PLOT DATE: 7/4/2019 8:53 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-B100 BRIDGE PLANS Saved by CLANDOLL Save date: 7/4/2019 8:04 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: B401 BRIDGE 4 - GENERAL BRIDGESD. RUGGLES N/A V. CHUNG V. CHUNG D. RUGGLES PLOT DATE: 7/4/2019 8:53 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-B100 BRIDGE PLANS Saved by CLANDOLL Save date: 7/4/2019 8:04 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: B402 BRIDGE 4 - ABUTMENT 1 BRIDGESD. RUGGLES N/A V. CHUNG V. CHUNG D. RUGGLES PLOT DATE: 7/4/2019 8:53 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-B100 BRIDGE PLANS Saved by CLANDOLL Save date: 7/4/2019 8:04 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: B403 BRIDGE 4 - ABUTMENT 2 BRIDGESD. RUGGLES N/A V. CHUNG V. CHUNG D. RUGGLES PLOT DATE: 7/4/2019 8:53 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-B100 BRIDGE PLANS Saved by CLANDOLL Save date: 7/4/2019 8:04 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: B404 BRIDGE 4 - ABUTMENT DETAILS BRIDGESD. RUGGLES N/A V. CHUNG V. CHUNG D. RUGGLES PLOT DATE: 7/4/2019 8:53 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-B100 BRIDGE PLANS Saved by CLANDOLL Save date: 7/4/2019 8:04 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: B501 BRIDGE 5 - GENERAL BRIDGESD. RUGGLES J. MCSWAIN V. CHUNG V. CHUNG D. RUGGLES PLOT DATE: 7/4/2019 8:53 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-B100 BRIDGE PLANS Saved by CLANDOLL Save date: 7/4/2019 8:04 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: B502 BRIDGE 5 - ABUTMENT 1 BRIDGESD. RUGGLES N/A V. CHUNG V. CHUNG D. RUGGLES PLOT DATE: 7/4/2019 8:53 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-B100 BRIDGE PLANS Saved by CLANDOLL Save date: 7/4/2019 8:04 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: B503 BRIDGE 5 - ABUTMENT 2 BRIDGESD. RUGGLES N/A V. CHUNG V. CHUNG D. RUGGLES PLOT DATE: 7/4/2019 8:53 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-B100 BRIDGE PLANS Saved by CLANDOLL Save date: 7/4/2019 8:04 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: B504 BRIDGE 5 - ABUTMENT DETAILS BRIDGESD. RUGGLES N/A V. CHUNG V. CHUNG D. RUGGLES PLOT DATE: 7/4/2019 8:54 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-W100 STRUCTURAL PLANS Saved by CLANDOLL Save date: 7/4/2019 8:30 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: C. LEWIS N/A C. LEWIS O. CANO C. LEWIS W000 GENERAL NOTES AND ABBREVIATIONS WALLS PLOT DATE: 7/4/2019 8:54 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-W100 STRUCTURAL PLANS Saved by CLANDOLL Save date: 7/4/2019 8:30 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: W001 XXX XXX XXX XXX XXX STATEMENT OF SPECIAL INSPECTIONS WALLS PLOT DATE: 7/4/2019 8:54 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-W100 STRUCTURAL PLANS Saved by CLANDOLL Save date: 7/4/2019 8:30 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: W100 XXX XXX XXX XXX XXX TYPICAL WALL SECTIONS WALLS PLOT DATE: 7/4/2019 8:54 AM BY: CLANDOLLFile: L:\PROJECTS\2019\L19013 - GRANDFATHER MOUNTAIN LAKE MASTER PLAN\DWGS\1 - DESIGN\SHEETS\L19013-W100 STRUCTURAL PLANS Saved by CLANDOLL Save date: 7/4/2019 8:30 AM75% DESIGN DO NOT USE FOR CONSTRUCTION HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 LOCH DORNIE DREDGING & SITE ENHANCEMENTS GRANDFATHER GOLF & COUNTRY CLUB LINVILLE, NORTH CAROLINA 32453-002 L19013 JULY 2019 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE. LEAD ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" STEWART NO.: HAZEN NO.: DATE: DRAWING NUMBER:STEWART 223 S. WEST STREET, SUITE 1100 RALEIGH, NORTH CAROLINA 27603 LICENSE NO.: C-1051 CHECKED BY: DRAWN BY: DESIGNED BY: LANDSCAPE ARCHITECT: W101 XXX XXX XXX XXX XXX FOUNDATION DETAILS WALLS