HomeMy WebLinkAboutWQCS00060_NOV-2019-DV-0318 Response_20190821old"M" WOW4 DEPARTMENT OF PUBLIC UTILITIES POST OFFICE BOX 2263 SMITHFIELD, N.C. 27577 (919)989-5075 August 21, 2019 Mr. Rick Bolich Raleigh Regional Office NCDEQ DWR 1628 Mail Service Center Raleigh, NC 27699-1628 Re: Response to NOV-2019-DV-0318 Permit No. WQC500060 - Johnston County Collection System Dear Mr. Bolich: NC Dept OfFnvironmental Quality AUIG 21 2919 Ralcigh RcgionaI Office In response to incident number 201901093 (101 NC Hwy 210, Smithfield), Johnston County offer the following information: • The spill was caused by an air release valve (ARV) saddle failure, which appeared to be due to corrosion from contact with the concrete cradle in the base of the manhole. See attached detail from the original construction drawings. • The failed ARV is located on a 20" force main that receives flow from eight wastewater pump stations. A portion of the wastewater flow from the eight wastewater pump stations was diverted into the existing parallel 12" force main, pumper trucks were used to pump and haul wastewater at several stations and the equalization basin and old aeration basin at Grifols were used to hold effluent flow while the force main was shut -down to complete the repair. In addition, some flow from Grifols was diverted into the Town of Clayton wastewater collection system while the 20" force main was shut -down for repair. The County utilized all means necessary in order to minimize the initial SSO and prevent additional potential SSOs while the 20" force main was shut -down for the repair. • The repair required removal of the concrete cradle that was originally poured with the initial ARV manhole installation. Once the concrete cradle was removed, a stone base was installed under the force main, the saddle was replaced and ARV re -installed. In addition to County staff, the County had two contractors on -site to assist with the repair. • The spill occurred for approximately 5 hours. • The County utilized a gas powered sewer pump to divert flow from the failed ARV into a nearby Town of Smithfield manhole, in order to drain the line to make the repair and to minimize the initial SSO, while the line was being shut -down and tributary wastewater pump stations were diverted or shut -down for pump and haul. • All necessary material, personnel and equipment were available for clean-up and to repair the ARV. At the SSO site, County staff vacuumed the sewer overflow from the spill area and lightly limed the area. • The County is working with a contractor to design and install a retrofit on all existing ARVs along this force main, in order to prevent additional future saddle failures. Furthermore, the ARVs are Printed on recycled paper Page 2 Mr. Bolich August 21, 2019 being routinely monitored and inspected until the retrofit is installed for the ARVs on this force main. In addition, we have prepared our department to respond quickly to pipe and appurtenance failures by maintaining an in-house supply of repair materials for all pipe sizes and implementing a detailed protocol for emergency response. Furthermore, the County maintains a close working relationship with several local contractors who provide emergency response repairs, as needed. Johnston County works aggressively to prevent sanitary sewer overflows and help protect the waters of our area. Please contact me at (919) 209-8333 or chandra.farmer@ioh,nstonnc.com if you have any questions or need additional information regarding this issue. Sincerely, cj��� C. ou�� Chandra C. Farmer, PE Director of Utilities cc: Rick J. Hester, County Manager Eric Narron Mitchell Hayes, Raleigh Regional Office C c� c FLEXIBLE SEAL ' MIN, 10 LF FORCE MAIN a . a CD 1V CENTERED ON MANHOLE �• w NOTES: a C i e' DIAR. PRECAST 0 c�D 1. FORCE MAIN PIPE SHALL BE CENTERED ACROSS MANHOLE. 2. CONTRACTOR TO INSTALL FORCE MAIN AT DEPTH REQUIRED TO FACILITATE INSTALLATION OF AIR RELEASE MANHOLE AT HIGH POINT OF LINE. 3. SEE PLANS FOR FORCE MAIN MATERIAL. 4. WHERE DUC nLE IRON PIPE IS SHOWN ON THE PLANS, DELETE THE CONCRETE BASE AND COAT THE OUTSIDE OF THE PIPE THE SAME AS THE INSIDE OF THE MANHOLE. 5' DIA. PRECAST CONCRETE MANHOLE WITH FLAT TOP ONC ETE MANHOLE WITH FLAT TOP 2,000 PSI CONCRETE BINATION AIR/VACUUM AIR RELEASE VALVE 2" 0 DRAIN HOLE IN CONCRETE (SLOPE FLOOR TO DRAIN) (TYP OF 2) LOCKABLE 24' RING do COVER NCDOT TRAFFIC RATED W/ 1" DRILLED VENT HOLE USE STAINLESS STEEL HEXHEAO BOLTS FLUSH WITH FINISHED GRADE 12" MIN. MANHOLE STEPS SHALL BE PLACED 16" O.C. WHEN 5' MIN, DEPTH OF MANHOLE EXCEEDS V. 1 BACK FLUSH ATTACHMENT WITH QUICK COUPLER 24" MAX. 1 /2 PIPE DIA, APPLY LUBRICANT TO EXTERIOR OF PVC PIPE TO PREVENT BOND TAPPING SADDLE 2" COMBINATION AIR/VACUUM AND AIR RELEASE VALVE 2" ISOLATION VALVE At .` _ r6-SCH INLET PIPING SHALL BE '''4 40 SS 316 INSIDE OF ARV MANHOLE SHALL BE FACTORY EPDXY COATED MIN. 50 MIL MIN 12" #57 STONE SURFACE DRY. EPDXY SEALER ON2,000 P51 CONCRETEPRIME COATING AND FINISHCOATING SHALL BE 2" !�!EClnl AIN HOLE NSP 100 AND NSP 120. (rfP OF 2) COMBINATION AIR/VACUUM AND AIR RELEASE MANHOLE FOR FORCE MAIN NOT TO SCALE ADDENDUM NO. 1 PAGE Dopa&nwA of PLok Won CD