Pump & Haul Request Cover Letter
Mr. Ori Tuvia,
AUC
MOORFSViLLe Rf OIONAL OFFIC'
Corvid Technologies is constructing its new Headquarters in Mooresville, NC and would like to
request for a Pump and Haul permit in order to occupy the building while the remainder of the
utility work is complete. All of these utilities will be taken over by the Town of Mooresville
upon completion. A quick summary of the project and related calculations for usage is below.
Please let me know if you have any further questions or need any additional information.
Project
Corvid Technologies Headquarter Building & Data Center
153 & 169 Langtree Campus Drive
Mooresville NC — 28117 (Note, this address is not yet in Google Maps)
The HQ building is 4 floors and approximately 88,000 SF. The Data Center is 1 floor and
25,000 SF. The Corvid site work and building construction began in June of 2018 and we
anticipate beginning to move into the new space in mid/late August with 155 employees. Note,
only the 41h and half of the 3`d floor will be fully built out day 1 so we will not be occupying all 4
floors until we lease out the remaining space to tenants. The Langtree Campus Drive (new road
being built to connect the building to Transco Rd) Public Bid process was delayed several
months for a myriad of reasons but it is on track to be complete in mid/late August, however, the
full Force Main install likely will not be fully complete until October. The roadwork, gravity
sewer and waterline will be complete in mid/late August, so we will be able to get our Certificate
of Occupancy at that time. We only anticipate needing the Pump and Haul permit for a couple of
months, Le, mid -late August to mid/late October.
Flow Rate Calcs From Bloc Design:
NCDEQ Wastewater Design Flow Rate for the two buildings would be:
General business and office facilities (25 gal/employee/shift) average daily flow
For the 155 employees anticipated for the first 6 months, you are looking at 3,875 gpd average
sanitary sewer flow.
(k—
Matt Hurley
Corvid Technologies
CORVID TECHNOLOGIES
145 Overhill Drive, Mooresville, IA.C;. 28117
Phone 704.799.6944 Fax 704.799.7974
www.corvidtechnologies.com
RECE(VED1NC[)EMR1r)W
J " Town of Mooresville
Development Services Department
Post Office Box 878
Mooresville, North Carolina 28115
July 8, 2019
Mr. Matt Hurley
Corvid Technologies, LLC.
153 Langtree Campus Drive
Mooresville, NC 28117
Subject: Corvid Technologies Headquarters Building & Data Center
153 & 169 Langtree Campus Drive
Mooresville, North Carolina
Mr. Hurley:
AUG 8
WQROS
MOORESVILLE REGIONAL OFFICE
The Town of Mooresville will accept wastewater at its Rocky River Wastewater Treatment Plant
(RRWWTP) via a temporary pump and haul for the above referenced project. We will accept
this discharge only at the headworks of the RRWWTP, located at 369 Johnson Dairy Road. No
discharge may be made at any other location within the collection system.
This approval extends to the following parameters only:
Approved Project: Corvid Technologies Headquarters Building & Data Center
Approved Duration: 6 months from commencement
Approved Discharge: Domestic
Approved Volume: 3,875 gallons
Approved Discharge Times: 8:00 a.m. — 5:00 p.m. Monday - Friday
Please contact Jamie Levis, WWTP Manager at 704-663-2840 or jlevis(2mooresvillencgov to
coordinate this process.
Thank you,
Jonathan Young
Engineering Services Director
CC: Jamie Levis
Allison Kraft
9 14 "Vila
SEPTIC TANK SERVICE
Lentz Septic Tank Service, Inc. Mr. Matt Hurley
410 Lentz Rd Corvid Technologies LLC.
Statesville, NC 28625 153 Langtree Campus Dr.
(704)876-1834 Date: July 15,2019 Mooresville NC 28117
Dear Mr. Hurley,
Lentz Septic Tank Service, Inc. agrees to pump and haul as needed, the wastewater
from a holding tank for the buildings located at 153 & 169 Langtree Campus Drive,
Mooresville North Carolina. The sewage pumped will be transported and disposed of
at the headworks of the RRWWTP, located at 369 Johnson Dairy, Mooresville, NC.
We will charge 18 cents per gallon, with a minimum of 3500 gallons. This does not
cover a charge per gallon at the Rocky River WWTP, Our state license number is
NCS00147
Keith Lentz — President
Lentz Septic Tank Service, Inc.
Office:704.876.1834 www.Ientzseptic.com Fax:704.876.1837
State of North Carolina
Department of Environmental Quality
Division of Water Resources
15A NCAC 02T .0200 —WASTEWATER PUMP AND HAUL SYSTEMS
"Division of Water Resources INSTRUCTIONS FOR FORM P&H 01-16 & SUPPORTING DOCUMENTATION
Documents shall be prepared in accordance with 15A NCAC 02T .0100, 15A NCAC 02T .0200, and Division policies. Failure to submit
all required items will necessitate additional processing and review time. For more information, visit the Wastewater Branch's
website or contact the Regional Office serving your county.
General — This permit application applies to all pump and haul activities of wastewater under the authority of the Division on Water
Resources. Permit coverage is required for the system producing the wastewater. This permit does not apply to the transport of
animal waste from an animal waste management systems, not the transport of wastewater residuals or biosolids.
NOTE: Pump and haul permits are not acceptable long term domestic wastewater treatment alternatives and shall only be issued
in cases of environmental emergencies, nuisance conditions, health problems, or for unavoidable delays in construction of system
previously permitted by the Division.
The Applicant shall submit one original and one copy of the application and supporting documentation.
A. Pre -submittal Contact & Cover Letter
® Contact the appropriate Regional Office prior to submittal
® Submit a cover letter explaining the circumstances associated with this pump and haul permit request
B. Application Fee (Domestic Wastewater Only)
® Submit a check made payable to: North Carolina Department of Environmental Quality (NCDEQ)
➢ The appropriate application fee is: $810.00 for flows < 10,000 GPD and $1,310.00 for flows > 10000 GPD
C. Wastewater Pump and Haul (FORM: P&H 01-16) Application:
® Submit the completed and appropriately executed Wastewater Pump and Haul (FORM: P&H 01-16) application. Any
unauthorized content changes to this form shall result in the application package being returned. If necessary for clarity or
due to space restrictions, attachments to the application may be made, as long as the attachments are numbered to
correspond to the section and item to which they refer
D. Receiving Facility Letter:
® Submit a letter from the owner/authority of the receivingwastewater treatment facility, as required by 15A NCAC 02T .0204
(b), stating that the pumped and hauled wastewater will be accepted and specifying the volume and type of wastewater that
will be accepted. The letter should be signed by an authorized signing official in accordance with 15A NCAC 02T .0106(b)
E. Contract Hauler Letter:
® Submit a letter from the hauler stating their capability and willingness to perform the pump and haul activity
® Letter shall include: Owner/Company; Name, Contact Information, & Hauling Volume of Vehicle(s)
F. Certifications:
® The Applicant's Certification on Page 4 of the application shall be signed in accordance with 15A NCAC 02T .0106(b). Per 15A
NCAC 02T .0106(c), an alternate person may be designated as the signing official if a delegation letter is provided from a
person who meets the criteria in 15A NCAC 02T .0106(b)
❑ The Professional Engineer's Certification on Page 5 of the application shall be signed, sealed and dated by a North Carolina
licensed Professional Engineer (if required)
G. Plans and Specifications (Required for activities that result in the Practice of Engineering per G.S. 89C-3):
❑ Submit two sets of plans and specifications (signed, sealed and dated by a N.C. Licensed Professional Engineer)
❑ Plans must include:
➢ A general location map
➢ Diagram of the components associated with the pump and haul activity (drains, piping, tanks, pumps, etc)
➢ Tank Details that indicate high water alarm
➢ Other items as required
INSTRUCTIONS FOR APPLICATION P&H 01-16 Page 1 of 5
I. PRESUBMITTAL INFORMATION: A (), 0 0 y) &q
1. Contacted representative from regional office (Pre -submittal)?: ® Yes ❑ No
2. Contact name (For Regional Office): Ori Tuvia
II. APPLICANT INFORMATION:
RI"CSIVEDA+ICDENR/DWR
AUG S n
WQROS
MOORESVILLE REGIONAL OFFICE
1. Applicant's name (Municipality, Individual, Corporation, etc): Corvid Technologies, LLC
2. Applicant type: ❑ Municipal ❑ State ❑ Privately -Owned Public Utility
❑ County ❑ Other: LLC
3. Origin of Wastewater:
❑ Residential Subdivision
❑ Retail (Stores, Shopping Centers) Domestic:
❑ Apartments/Condominiums
❑ Institution Commercial
❑ Mobile Home Park
❑ Hospital Industrial:
❑ School
❑ Church Other:
❑ Restaurant
❑ Nursing Home
® Office
❑ Other (specify)
4. Signature authority's name: Matthew Hurley per 15A NCAC 02T .0106(b)
Title: Operations Manager
5. Applicant's mailing address: 145 Overhill Dr
City: Mooresville State: NC
Zip: 28117-
6. Applicant's contact information:
Phone number: (703) 731-5325 Email: matt. hurleygcorvidtec.com
III. CONTACT/CONSULTANT INFORMATION:
1. Contact name: Not Applicable
Title/Affiliation:
2. Contact's information:
Phone number: (_) = Email:
IV. RECEIVING FACILITY INFORMATION:
100
If more than 1 facility has agreed to accept the wastewater, please list all the owners, facility names, and permit
numbers as a separate attachment)
1. Owner: Town of Mooresville
2. Facility name: Rocky River Wastewater Treatment Plant
3. Facility permit number: WQCS0043 (Collection System Number
4. WWTF permit number: NCO046728
5. WWTF contact name: Jamie Levis
Title/Affiliation: Manager
6. WWTF contact information:
Phone number: (704) 663-2840
Email: jlevis e,mooresvillenc
APPLICATION P&H 01-16 Page 3 of 5
THE ENGINEER'S CERTFICATION IS REQUIRED FOR ACTIVITIES THAT RESULT IN THE PRACTICE OF ENGINEERING PER G.S. 89C-3.
ENGINEERING DOCUMENTS MUST BE COMPLETED PRIOR TO SUBMITTAL. IF CERTIFICATION BY AND ENGINEER IS REQUIRED,
THIS PAGE IS NOT NECESSARY.
Professional Engineer's Certification: (Signature of Design Engineer and Project Name)
I, David S. Klausman ,attest that this application for Corvid Technologies, LLC has been reviewed by me and is
accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting
documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been
prepared in accordance with all the applicable regulations. Although other professionals may have developed certain portions
of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material
and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and
143_...__•• 215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be
guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per
violation.
David S. Klausman
Professional Engineer Name
itil1e lP
Bloc Design, PLLC
Engineering Firm .R
SEAL * ::
2923 South Tryon Street - Suite 320 _ 35711
Mailing Address
Charlotte 2e. NC 2f. 28203••,.
City State Zip 1. "+rir1941101, x
7.9f/.9
803-513-4734 2h. N/A 2i. dklausman@bloc-nc.com
Telephone Facsimile E-mail NC PE Seal, Signature &Date
APPLICATION P&H 01-I6 Page 5 of 5
IIII
we
V§ $
• 1�� -
d
aLGa
S
1`
i�d pa�
IIIIr,
cE
8si
§
N
N
Ru
®
—2a
f�!
�llE�
t
i
gy$y$y yy
��
33�3