Loading...
HomeMy WebLinkAboutSW6190504_014_C7.3_Details_7/22/2019WASHED BERMUDA SOD SIDES AND BOTTOM OF INFILTRATION BASIN. SOD SHOULD BE GROWN IN SANDY SOILS. CURB CUT AND FLUME ELEV. = 248.62 SECTION A -A EROSION CONTROL BLANKET ON SPILLWAY BIONETSC15OBN EXTENDED —TERM BIODEGRADABLE DOUBLE —NET STRAW/COCONUT BLANKET STORM ELEVATIONS: TOP OF DAM — 1—YR: 247.77 ELEV. = 249.50 2—YR: 247.85 10—YR: 247.93 ROOF DRAIN LEADER 100—YR: 248.07 OUTLET: ±248.50 1" DESIGN STORM: 248.06 J11VV I L4J J I=1 I I=1 11I SCALE 1" = 5' (V) SCALE 1" = 10' (H) WASHED BERMUDA SOD SIDES AND BOTTOM OF INFILTRATION BASIN. SOD SHOULD BE GROWN IN SANDY SOILS. 15 FT WIDE SPILL WAY ELEVATION = 248,50 EROSION CONTROL BLANKET ON SPILLWAY BIONET SC15OBN EXTENDED —TERM BIODEGRADABLE DOUBLE —NET STRAW/COCONUT BLANKET RIP —RAP OUTLET 1 18'W X 91 X 18"D CLASS B 0 I< l' I.. I I l I I i I' I I ( I L I I I cq L. I I � I I [ I I I L ( L � \ I I \ 249. % 248 248.0 d INFILTRATION BASIN 1 PLAN SCALE 1" = 20' 1I I I� WASHED BERMUDA SOD ...... — SIDES AND BOTTOM OF — INFILTRATION BASIN. SOD SHOULD BE GROWN IN I SIDE SLOPE — 3:1 MAX. SANDY SOILS. — —_ SHWT:_ EXISTING SOIL —III— 'TURN' IN —SITU SOIL TO REDUCE COMPACTION TEST INFILTRATION BEFORE AND AFTER INSTALLATION OF SOD. MINIMUM INFILTRATION 2.0 IN/HR. TYPICAL INFILTRATION BASIN (ABOVE SURFACE STORAGE) SECTION NTS RIP —RAP OUTLET 5 2'W X 61 X 30"D — CLASS B RIP —RAP OUTLET 2 18'W X 91 X 18"D — CLASS B RIP —RAP OUTLET ROOF DRAIN 2'W X 61 X 18"D — CLASS B (TYP. ALL ROOF DRAIN OUTLETS) RIP —RAP OUTLET 3 18'W X 91 X 18"D — CLASS B 15" RCP OVERFLOW PIPE APPROVED FOR CONSTRUCTION THESE PLANS WERE USED FOR PERMITTING AND DO NOT REFLECT CHANGE ORDERS OR MODIFICATIONS MADE DURING CONSTRUCTION. WASHED BERMUDA SOD SIDES AND BOTTOM OF INFILTRATION BASIN. SOD SHOULD BE GROWN IN SANDY SOILS. STORM ELEVATIC" 1 —YR: 247.29 2—YR: 247,37 10—YR: 247.47 100—YR: 247.6: 1 " DESIGN STOP BORINGS IN THIS LOCATION, WHICH WENT TO 5 FEET, DID NOT SHOW SIGNS OF A SHWT FLARED END SECTION CURB AND GUTTER 15" RCP OVERFLOW PIPE SECTION B-B SCALE 1" = 5' (V) SCALE 1" = 10' (H) CALL BEFORE YOU DIG! NORTH CAROLINA LAW REQUIRES NOTIFICATION OF THE UNDERGROUND FACILITY OWNER NOT LESS THAN TWO (2) BUT NO MORE THAN TEN (10) WORKING DAYS PRIOR TO EXCAVATION OR DEMOLITION 4RTH CARO N www.nc811.org811 1-800-632-4949 North Carolina One -Call Center, Inc. ,11 10 20 40 .1 REVISIONS No. DATE DESCRIPTION REV. BY Q 9 JULY 1 cl UPDATE TITLEBLOCK, ADD SCM SECTIONS A 0 0 W Q' W U) W Of cn F— C9 J J Q U Z Z) m z C7 U) w 0 m m 0 m rn 0 N O 0 a 0 0 CD Z 0 ov J ry J U tD Q Z O U w � Q O WJ W� � (D �U Q ao 0 w ao m ww O 'it < �of (o 0�