Loading...
HomeMy WebLinkAboutSW5190702_SCM Supplemental Form_7/12/2019SUPPLEMENT-EZ COVER PAGE FORMS LOADED FORMS LOADED Certification Statement: I certify, under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision; that the information provided in the form is, to the hest of my knowledge and belief, true, accurate, and complete; and that the engineering plans, specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here. 1�•;'stE ifg+�R+0arst0"P� �`�' Ph c, I -0-0 m' Date I IF DRAINAGE AREAS 1 Is this a high density project? Yes 2 If so, number of drainage areas/SCMs 2 SCMs 1 3 Is all/part of this project subject to previous rule versions? No FORMS LOADED DRAINAGE AREA INFORMATION Entire Site 1 2 4 Type of SCM Sand Filter Sand Filter 5 Total BUA in project (sq ft 267420 sf 107956 sf 148392 sf 6permitting) New BUA on subdivided lots (subject to s ft 7permitting) New BUA outside of subdivided lots (subject to sf 267420 sf 107956 sf 148392 sf 8 JOffsite - total area (sq ft 9 Offsite BUA (sq ft 10 Breakdown of new BUA outside subdivided lots: Parking (sq ft 108359 sf 40447 sf 58635 sf Sidewalk (sq ft 41416 sf 18864 sf 20757 sf Roof (sq ft 117645 sf 48645 sf 69000 sf Roadway s ft Future (sq ft Other, please specify in the comment box below (sq ft 11 New infiltrating permeable pavement on subdivided lots (sq ft 12 New infiltrating permeable pavement outside of isubdivided lots (sq ft 13permitting) Exisitng BUA that will remain (not subject to s ft 14 Existing BUA that is already permitted (sq ft 15 Existing BUA that will be removed (sq ft 16 Percent BUA 33% 60% 63% 17 Design storm inches 1 in 1 in 1 in 18 1 Design volume of SCM cu ft 6635 cf 9093 cf 19 lCalculation method for design volume Simple Simple Simple DDITIONAL INFORMATION 20 Please use this space to provide any additional information about the drainage area(s): The site was analyzed at one point of discharge and there are two sub - basins, one for each SCM. SAND FILTER 18 SHWT elevation (fmsl) N/A N/A 19 Type of sand filter (open or closed) Closed Closed 20 If closed, will the filter will be pre -cast or pour -in -place? Pre Cast Pre Cast 21 If closed, top of grate elevation (fmsl) 436.5 435.6 22 Is this sand filter designed to attenuate peak flows? No No Sediment Chamber 23 Volume that can be retained in the sediment chamber (cubic feet) 3360 cf 4725 cf 24 Will there be a permanent pool in the sediment chamber? Yes Yes 25 Bottom of the sediment chamber (fmsl) 428.00 426.10 26 Area of the sediment chamber (square feet) 840 sf 945 sf 27 Physical depth of the sediment chamber (inches) 96 in 108 in 28 Ponding depth in the sediment chamber, above any permanent pool (inches) 63 in 75 in 29 Elevation of top of weir between chambers (fmsl) 430.75 428.85 Sand Chamber 30 Volume that can be retained in the sand chamber (cubic feet) Bottom of the sand chamber (fmsl) 3360 cf 4725 cf 31 428.00 426.10 32 Area of the sand chamber (square feet) 840 sf 945 sf 33 Physical depth of the sand chamber (inches) 18 in 18 in 34 Ponding depth in the sand chamber, above any permanent pool (inches) 48 in 60 in 35 Elevation of the bypass device (fmsl) 434.75 433.85 36 Type of bypass device Weir Weir 37 Mechanism for distributing flow over the sand surface 38 Sand specification for sand chamber ASTM C33 ASTM C33 39 Depth above underdrain pipe (inches) 25 in 25 in Will the media be maintained to drain at least two inches per hour at thesandsurface? Yes Yes L14 Is at least one clean -out pipe provided at the low point of each underdrain line? Yes Yes Will clean -out pipes be capped? Yes Yes Sand Filter 1 5:31 PM 7/9/2019