HomeMy WebLinkAbout310670_Plan of Action_20181001PLAN OF ACTION(Poa) FOR HIGH FREEBOARD AT ANIMAL FACILITIES
Facility Number: 31-670
Facility Name:
Quail Run
County: Duplin
Certified Operator Name: Joe Szaloky Operator Number:
AWA999328
1. Current liquid level(s) in inches as measured from the current liquid level in the lagoon to the
lowest point on the top of the dam for lagoons without spillways; and from the current liquid level
in the lagoon to the bottom of -the spillway for lagoons with spillways.
Lagoon Name/ID
Spillway(Y or N):
Level(inches):
Lagoon 1 Lagoon 2 Lagoon 3 Lagoon 4 Lagoon 5
L1 L2
N N
15 16
2. Check all applicable items -
Liquid level is within the designed structural freeboard.elevations of one or more structures.
Five and 30 day Plans of Action are attached. Hydraulic and agronomic balances are
within acceptable ranges.
X Liquid level is within the 25 year 24 hour storm elevations for one or more structures. A
30 day Plan of Action is attached. Agronomic balance is within acceptable range.
Waste is to be pumped and hauled to off site locations. Bolume and PAN content of waste
to be pumped and hauled is reflected in section III tables. Included within this plan is a list
of the proposed sites with related facility numbers, number of acres and receiving crop
information. Contact and secure approval from the DWQ prior to transfer of waste to a site
not covered in the facility's CAWMP.
Operation will be partially or fully depopulated.
*Attach a complete schedule with corresponding animal units and dates fro depopulation
*if animals are to be moved to another permitted facility, provide facility number, lagoon
freeboard levels and herd population for the receiving facility
3. Earliest possible date to begin land application of waste: as conditions permit
I hereby certify that I have reviewed the information listed above and included within the
attached Plan of Action, and to -the best of my knowledge -and ability, the information is
accurate and correct.
Advantage Farms LLC Phone: 910-293-3434
Facility Owner/Manager (print)
op_ ` Date: 9/9/2018
Facility Owner/Manage signature)
f
I
lu
II. TOTAL POUNDS OF PAN STORED WITHIN STRUCTURAL FREEBOARD AND/OR'25 YR./24
HR. STORM STORAGE ELEVATIONS IN ALL WASTE
STRUCTURES FOR FACILITY
1.
Structure ID* 4208
line m =
1561.7 lb PAN
2.
Structure ID- 4209
line m =
1296.8 lb PAN
3
Structure ID:
line m =
lb PAN
4.
Structure ID:
line m =
lb PAN .
5.
Structure ID:
line m =
lb PAN
6.
Structure ID:
line m =
lb PAN
n.lines 1+2+3+4+5+6= 2858.5lbPAN
III. TOTAL PAN BALANCE REMAINING FOR AVAILABLE CROPS DURING 30 DAY DRAW DOWN
PERIOD. DO NOT LIST FIELDS TO WHICH PAN CANNOT RF APPI IFD DIIRIN(; THIS An r)AY PFRIOn
o. tract #
p. field #
q. crop
r. acres
s. remaining IRR
2 PAN balance
(lb/acre)
t. TOTAL PAN
BALANCE FOR
FIELD (Ibs.)
column r x s
u. application window'
QR
1
Wheat
4.29
125.40
538.0
Sept -April
QR
2
Wheat
4.31
125.40
540.5
Sept -April
QR
3
Wheat
3.35
125.40
420.1
Sept -April
QR
4
Wheat
5.16
125.40
647.1
Sept -April
QR
5
Wheat
4.48
123.31
552.4
Sept -April
QR
6
Wheat
4.03
123.31
496.9
Sept -April
'State current crop ending application date or next crop application beginning date for available
receiving crops during 30 day draw down period.
v. Total PAN available for all fields (sum of column t) = 3195.0 lb. PAN
IV. FACILITY'S PoA OVERALL PAN BALANCE
w. Total PAN to be land applied (line n from section II) = 2858.5 lb. PAN
PoA (30 Day) 2/21/00
x. Crop's remaining PAN balance (tine v from section Ill) = 3195.0 lb. PAN
y. Overall PAN balance (w - x) _ -336 lb. PAN
Line y must show as a deficit. If line y does not show as a deficit, list course of action here including pump and
haul, depopulation, herd reduction, -etc. For pump & haul and herd reduction options, recalculate new PAN
based on new information. If new fields are to be included as an option for lowering lagoon level, add these
fields to the PAN balance table and recalculate the overall PAN balance. If animal waste is to be hauled to
another permitted facility, provide information regarding the herd population and lagoon freeboard levels at the
regeiving facility.
NARRATIVE:
Irrigation onto existing spray fields will continue as weather and field conditions permit. Additional land is
available for pumping if needed. Josh Gaddy has written an extension for application to the corn crop thru July
21 st. A waste sample has been taken and results producer is waiting for results.
PoA (30 Day) 2/21/00
J
PLAN OF ACTION (PoA) FOR HIGH FREEBOARD AT ANIMAL FACILITIES
30 DAY DRAW DOWN PERIOD
I. TOTAL PAN TO BE LAND APPLIED PER WASTE STRUCTURE
1. Structure Name/Identifier (ID): 4208
2. Current liquid volume in 25 yr./24 hr. storm storage & structural freeboard
a current liquid level according to marker
b. designed 25 yr./24 hr. storm & structural freeboard
c. line b - line a (inches in red zone) =
d. top of dike surface area according to design
(area at below structural freeboard elevation)
e. line c/12 x line d x 7.48 gallons/ft3
3. Projected volume of waste liquid produced during draw down period
15.0 inches
19.5 inches
4.5 inches
1198801 ft2
336263 gallons
f. temporary storage period according to structural design 180 days
g. volume of waste produced according to structural design 161410.9 ft3
h. current herd #F 4896 certified herd #1 4896
actual waste produced = current herd # x line g = 161411 ft'j
certified herd #
i. volume of wash water according to structural design
j. excess rainfall over evaporation according to design
k. (lines h + i + j) x 7.48 x 30 days/line f=
4. Total -PAN to be land applied during draw down period
I. current waste analysis dated 6/8/2018
m. ((lines e + k)/1000) x line I =
REPEAT SECTION I FOR EACH WASTE STRUCTURE ON SITE.
(Click on the next Structure tab shown below)
PoA (30 Day) 2/21/00
01ft3
69930 ft3
288405 gallons
2.50 lbs/1000 gal.
1561.7 lbs. PAN
P
PLAN OF ACTION (PoA) FOR HIGH FREEBOARD AT ANIMAL FACILITIES
30 DAY DRAW DOWN PERIOD
I. TOTAL PAN TO BE LAND APPLIED PER WASTE STRUCTURE
1. Structure Name/Identifier (ID): 14209
2. Current liquid volume in 25 yr./24 hr. storm storage & structural freeboard
a. current liquid level according to marker 16.0 inches
b. designed 25 yr./24 hr. storm & structural freeboard 19.0 inches
c. line b - line a (inches in red zone) = 3.0 inches
d top of dike surface area according to design
(area at below structural freeboard elevation) 119880 ft2
e. line c/12 x line d x 7.48 gallons/W 224176 gallons
3. Projected volume of waste liquid produced during draw down period
f. temporary storage period according to structural design 180 days
g volume of waste produced according to structural design 161410.9 ft3
h. current herd # 4896 certified herd # 4896
actual waste produced = current herd # x line g = 161411 ft3
certified herd #
i. volume of wash water according to structural design 01ft3
j excess rainfall over evaporation according to design 69930 ft3
k. (lines h + i + j) x 7.48 x 30 days/line f= 288405 gallons
4. Total PAN to be land applied during draw down period
I. current waste analysis dated 6/8/2018 2.53 Ibs/1000 gal.
M. ((lines e + k)/1000) x line 1 = 1296.8 lbs. PAN
REPEAT SECTION I FOR EACH WASTE STRUCTURE ON SITE.
(Click on the next Structure tab shown below)
PoA (30 Day) 2121/00