HomeMy WebLinkAboutSW3190505_Suppliment EZ Form_20190607SUPPLEMENT-EZ COVER PAGE
FORMS LOADED
PROJECT INFORMATION
1 Project Name n...,R - _ r_.`-
1 COURTYARDS ON LAWYERS ROAD
2 Project Area (ac) 50.337
4 1 Surface Water Area ac
5 Is this project High or Low Density?
6 Does this project use an off -site SCM?
0
0.93
High
No
:.COMPLIANCE WITH 02H .1003(4)
7 Width of vegetated setbacks provided (feet) 100
_ 4--
8 Will the vegetated setback remain vegetated? Yes
9 Is BUA other that as listed in .1003(4)(c-d) out -of the setback? Yes
10 Is streambank stabilization proposed on this project? No
!NUMBER AND TYPE OF SCMs:
11 Infiltration System _ 0
12 Bioretention Cell 0
13
Wet Pond
2
14
Stormwater Wetland
0
15
Permeable Pavement
0
16
Sand Filter
0
17
Rainwater Harvesting RWH
0
18
Green Roof
0
19
Level Spreader -Filter Strip LS-FS
0
20
Disconnected Impervious Surface (DIS)
0
21
Treatment Swale
0
22
Dry Pond
0
23
StormFilter
0
24
Silva Cell
0
25 JBayfilter
0
26
Filterra
0
FORMS LOADED
1ESIGNER CERTIFICATION
27 Name and Title:
28 Organization: _
29 ,Street address:
30 ICity, S
31 JPhone
32 Email:
V
PE
PO BOX 1198
PIN_ EVILLE, NC, 28134
_ 704-556-1990
VINCEK@Y-WH.COM
INC.
Certification Statement:
I certify, under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or
supervision; that the information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete; and
that the engineering plans, specifications, operation and maintenance agreements and other supporting information are consistent
with the information provided here.
64*1N#ryJ
\� CAR
11637
4",44
WET POND
1 jDrainage area number t 2
2 Design volume of SCM (cu ft) 400750 cf 129200 of
:GENERAL MDr FROM 02H .1050
3
Is the SCM sized to treat the SW from all surfaces at build -out?
Yes
Yes
4
Is the SCM located away from contaminated soils?
Yes
Yes
5
What are the side slopes of the SCM (H:V)?
3:1
3:1
6
Does the SCM have retaining walls, gabion walls or other engineered
side slopes?
No
No
7
Are the inlets, outlets, and receiving stream protected from erosion
(10-year storm)?
Yes
Yes
8
Is there an overflow or bypass for inflow volume in excess of the
1 design volume?
Yes
Yes
9
What is the method for dewatering the SCM for maintenance?
Pump (preferred)
Pump (preferred)
10
If applicable, will the SCM be cleaned out after construction?
Yes
Yes
11
Does the maintenance access comply with General MDC (8)?
Yes
Yes
12
Does the drainage easement comply with General MDC (9)?
Yes
Yes
13
If the SCM is on a single family lot, does (will?) the plat comply with
General MDC (10)?
Yes
Yes
14
Is there an O&M Agreement that complies with General MDC (11)?
Yes
Yes
15
Is there an O&M Plan that complies with General MDC (12)?
Yes
Yes
16
Does the SCM follow the device specific MDC?
Yes
Yes
17 1 Was the SCM designed by an NC licensed professional?
WET POND MDC FROM 02H .1053
18 1 Method used
Yes
SA/DA
Yes
SA/DA
19
Has a stage/storage table been provided in the calculations?
Yes
Yes
20
Elevation of the excavated main pool depth (bottom of sediment
removal) (fmsl)
651.50
651.00
21
Elevation of the main pool bottom -(top of sediment removal) (fmsl)
652.50
652.00
22
Elevation of the bottom of the vegetated shelf (fmsl)
660.00
662.00
23
Elevation of the permanent pool (fmsl)
660.50
662.50
24
Elevation of the top of the vegetated shelf (fmsl)
661.00
663.00
25
Elevation of the temporary pool (fmsl)
667.97
669.78
26
Surface area of the main permanent pool (square feet)
29000
8000
27
Volume of the main permanent pool (cubic feet)
151250 of
38775 cf
28
Average depth of the main pool (feet)
6.20 ft
6.10 ft
29
Average depth equation used
Equation 3
Equation 3
30
If using equation 3, main pool perimeter (feet)
915.1 ft
363.3 ft
31
If using equation 3, width of submerged veg. shelf (feet)
5.0 ft
5.0 ft
32
Volume of the forebay (cubic feet)
31500 cf
9665 cf
33
Is this 15-20% of the volume in the main pool?
No
No
34
Clean -out depth for forebay (inches)
48 in
63 in
351
Design volume of SCM (cu ft)
400750 cf
129200 cf
36
Is the outlet an orifice or a weir?
Orifice
Orifice
37
If orifice, orifice diameter (inches)
18 in
24 in
38
If weir, weir height (inches)
39
If weir, weir length (inches)
40
Drawdown time for the temporary pool (days)
2
2
41
Are the inlet(s) and outlet located in a manner that avoids short-
circuiting?
Yes
Yes
42
Are berms or baffles provided to improve the flow path?
No
No
43
Depth of forebay at entrance (inches)
116 in
146 in
44
Depth of forebay at exit (inches)
96 in
126 in
45
Does water flow out of the forebay in anon -erosive manner?
Yes
Yes
46
Width of the vegetated shelf (feet)
loft
loft
47
Slope of vegetated shelf (H:V)
10:1
10:1
48,
Does the orifice drawdown from below the top surface of the
permanent pool?
Yes
Yes
49
Does the pond minimize impacts to the receiving channel from the 1-
yr, 24-hr storm?
Yes
Yes
50
Are fountains proposed? (If Y, please provide documentation that
MDC(9) is met.)
No
No
51
Is a trash rack or other device provided to protect the outlet system?
Yes
Yes
52 Are the dam and embankment planted in non -clumping turf grass? I
53 Species of turfthat will be used on the dam and embankment
( 541Has a planting plan been provided for the vegetated shelf?
'ADDITIONAL INFORMATION
Please use this space to provide any additional information about the
55 wet pond(s):
Yes
Yes
BERMUDA
BERMUDA
Yes Yes
Wet Pond 1 8:36 AM 5/2/2019