HomeMy WebLinkAboutWM0501352_More Information (Received)_20190507From:Katie Hackney
To:Byers, Brion N
Subject:[External] RE: NCDOT Site No. 11 - Monitoring Well Permit Application - Additional information Needed
Date:Tuesday, May 07, 2019 5:27:04 PM
Attachments:image001.png
CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an
attachment to report.spam@nc.gov
Hey Brion! Yes, it’s been busy and 6 months? Really? Time files! Below are my answers to yourquestions. 1) We do not plan to inject anything in these wells. I just listed any permit numbersthat exist for the site as the permit requests. The purpose of the two monitoringwell are horizontal definition of the plume.2) Anticipated construction (may vary depending on lithology encountered duringdrilling, but gravel pack typically 3 feet above screen, and 2 to 3 feet of bentoniteseal, then grout to land surface:11-MW17: 7 feet casing, 13 feet screen, gravel pack 10-20’ BLS, bentonite 8-10’BLS, grout 0-8’ BLS11-MW17D: 40 feet casing, 10 feet screen, gravel pack 37’ – 50’ BLS, bentonite5’-37’ BLS, grout 0’-5’ BLS3) I do not know of any other sources of possible contamination within 500’ of the site.All properties are on town sewer, and I do not know or any agricultural or industrialcontamination sites within 500 feet. Please let me know if you require further information. Thanks! Sincerely,Katie T. Hackney, P.G.
Senior Hydrogeologist
Groundwater Management Associates, Inc.
4300 Sapphire Court, Suite 100
Greenville, North Carolina 27834
Phone (252) 758-3310
www.gma-nc.com
From: Byers, Brion N [mailto:brion.byers@ncdenr.gov]
Sent: Thursday, May 02, 2019 1:45 PM
To: katie@gma-nc.com
Subject: NCDOT Site No. 11 - Monitoring Well Permit Application - Additional information Needed
Hi Katie,
I hope things have been going well for you, hard to believe it has been six months since I left GMA.
I have briefly looked over the monitoring well application that you submitted, I additional
information for a couple of things:
- We will need the original copy with the “wet” signature of the applicant, without the ”wet”
signature we cannot issue the permit.
- I need additional information on the proposed well construction, including interval for the
gravel pack, bentonite seal and grout.
- Also under the “Additional Information” Section e. of the permit, let me know if any of these
sources are present within 500 feet.
Please feel free to call me if you have any questions.
Thank you,
Brion
Brion N. Byers, P.G.
Hydrogeologist
Division of Water Resources – Raleigh Regional Office
Department of Environmental Quality
(919) 791-4237 office
brion.byers@ncdenr.gov
Physical: 3800 Barrett Drive, Raleigh, NC 27609
Mailing: 1628 Mail Service Center, Raleigh, NC 27699-1628
Email correspondence to and from this address is subject to the
North Carolina Public Records Law and may be disclosed to third parties