Loading...
HomeMy WebLinkAbout20190622 Ver 1_SF-030217_HYD_SMPv2.07_20180531_20190510I-lighway North Carolina Department of Transportation Stot'tnYt✓afet Highway Stormwater Program \ STORMWATER MANAGEMENT PLAN (Version 2.07; Released October 2016) FOR NCDOT PROJECTS WBS Element: 17BP.10.R.140 TIP No.: SF-030217 County(ies): ANSON Page 1 of 1 General Project Information WBS Element: 178P.10.R.140 ITIP Number: SF-030217 Project Type: Bridge Replacement Date: 5/31/2018 NCDOT Contact: Marc T Shown Contractor / Desi ner: STV Engineers, Inc. / Shirshant Sharma Address: 1020 Birch Ridge Drive Raleigh, NC 27610 Address: 900 West Trade Street, Ste. 715 Charlotte, NC 28202 Phone: 919 707 6751 Phone: 704 816-2556 Email: mshown ncdot. ov Email: Shirshant.Sharma stvinc.com Cit (Town: Wadesboro Count ies : Anson River Basins : Yadkin -Pee Dee ICAMA County? I No Wetlands within Project Limits? No Project Description Project Length (lin. miles or feet): 0.08 Surrounding Land Use: IRural, wooded, agricultural Proposed Project Existing Site Project Built -Upon Area ac. 0.3 ac. 0.2 ac. Typical Cross Section Description: Roadway: Two 10' lanes, paved shoulders Bridge: Two 10' lanes, no shoulders Approach: Two 10' lanes, 4' shoulders Annual Avg Daily Traffic (veh/hr/day): Design/Future: 190 Year: 2025 Existing: 190 Year: 2013 General Project Narrative: (Description of Minimization of Water Quality Impacts) STV Engineers, Inc. is providing engineering services for the bridge replacement project on SR 1654 (Morton Road) over Lanes Creek. The existing bridge is a 135.3'(1 @45'2", 2@45'1") triple -span bridge with a steel plank deck on I -beams and mass concrete abutments and interior bents. The proposed structure will be a 170' long bridge with a span arrangement of 1 @50' (21" cored slab), 1 @70' (24" cored slab) and 1 @50' (21" cored slab). The proposed roadway alignment over the bridge is the same as the existing bridge alignment. Overall drainage patterns will be maintained. There are roadside ditches that flow towards the bridge on either side of the structure. The drainage pattern of the ditches are being maintained and the drainage from the bridge is being discharged into the ditches. Deck drains will be needed for the proposed structure to prevent spreading inside the travel lane. The deck drains will not discharge directly to the jurisdictional stream. Deck drains will be located over the floodplain bench area as shown in the BSR. Impervious dikes with special stilling basins shall be used to contain the sediment laden water and prevent it from being discharged into the stream. Waterbody Information Surface Water Body (1): Lanes Creek NCDWR Stream Index No.: 13-17-40-(12) NCDWR Surface Water Classification for Water Body Primary Classification: Class C Supplemental Classification: None Other Stream Classification: None Impairments: None Aquatic T&E Species? No Comments: NRTR Stream ID: Buffer Rules in Effect: N/A Project Includes Bridge Spanning Water Body? Yes Deck Drains Discharge Over Buffer? INo Dissipator Pads Provided in Buffer? N/A Deck Drains Discharge Over Water Body? INo (If yes, provide justification in the General Project Narrative) (If yes, describe in the General Project Narrative; if no, justify in the General Project Narrative) (If yes, provide justification in the General Project Narrative)