HomeMy WebLinkAboutWQ0011765_Compliance Evaluation Inspection_20190115ROY COOPER
Governor
MICHAEL S. REGAN
Secretary
LINDA CULPEPPER
Director
Mr. Curt Beeman via Email
9200 Perth Court
Concord, North Carolina 28027
Dear Mr. Beeman:
NORTH CAROLINA
Environmental Quality
January 15, 2019
Subject: Non -Discharge Permit Inspection
Wastewater Surface Irrigation System
Permit #WQ0011756
Cabarrus County
Staff of the Mooresville Regional Office (MRO) conducted a compliance inspection on January
8th 2019. The MRO would like to thank you for your time during the inspection. Per
conversation and observation, the treatment system and application fields appear maintained in
accordance with the permit, at the time of inspection.
Please note the following comments to maintain overall program compliance:
• All tanks should be assessed annually for residuals and scum layers and pumped as
needed.
• The application field requires routine maintenance for removal of saplings, downed
trees, etc. as noted in the report.
• This permit is currently in the renewal process with our central office permitting staff.
You may contact Ranveer.Katyal(aD_ncdenr.gov with specific questions related to the
renewal.
• For future reference, all forms may be located on our web -site at:
https:Hdeg. nc.gov/about/divisions/water-resources/water-resources-permits/wastewater-
branch/non-discharge-permitting-unit/application. Scroll the page to the "Single Family
Residence" systems section. A copy of the Ownership/Name Change Form is attached
for convenience, but only needs completion should the property change hands prior to
the next permit renewal.
D Q North Carolina Department of Environmental Quality I Division of Water Resources
Mooresville Regional Office 1 610 East Center Avenue, Suite 301 1 Mooresville, North Carolina 28115
NORTH CAROHNA �
o.namremor �w.c�giuuei� /`� 704.663.1699
The inspection report should be self-explanatory; however, please contact Maria Schutte by
phone (704-235-2184) or email (maria.schutte(a)ncdenr.gov) with questions.
Sincerely,
EA
DocuSigned by:
*-.� H P44414
F161 FB69A2D84A3...
Andrew H. Pitner, P.G., Assistant Regional Supervisor
Mooresville Regional Office
Water Quality Regional Operations Section
Division of Water Resources, NCDEQ
Attachments: WQ0017507 Inspection Report
Ownership/Name Change Form NDPONC
Compliance Inspection Report
Permit: WQ0011765 Effective: 05/01/14 Expiration: 04/30/19 owner: Curt P Beeman
SOC: Effective: Expiration: Facility: 9200 Perth Ct. SFR
County: Cabarrus 9200 Perth Ct
Region: Mooresville
Concord NC 28027
Contact Person: Curt P Beeman Title: Phone: 704-787-8872
Directions to Facility:
System Classifications:
Primary ORC:
Secondary ORC(s):
On -Site Representative(s):
Related Permits:
Inspection Date: 01/08/2019
Primary Inspector: Maria Schutte
Secondary Inspector(s):
Certification:
Phone:
Entry Time: 09:30AM Exit Time: 11:35AM
Phone: 704-663-1699
Reason for Inspection: Routine Inspection Type: Compliance Evaluation
Permit Inspection Type: Single -Family Residence Wastewater Irrigation
Facility Status: Compliant Not Compliant
Question Areas:
Miscellaneous Questions Permit Status Sand Filter/Treatment Pods
Disinfection UV Pump Tank Drip or Irrigation
General
(See attachment summary)
Page: 1
Permit: WQ0011765 Owner - Facility: Curt P Beeman
Inspection Date: 01/08/2019 Inspection Type : Compliance Evaluation Reason for Visit: Routine
Inspection Summary:
System appears to be operating adequately. The field site conditions were better than anticipated, given considerably wet
weather conditions for past several months. As noted in comments, the field sites need routine maintenance for removal of
undergrowth/small saplings.
Owner is knowledgeable of system, performs most maintenance himself and keeps an excellent inspection and
maintenance spreadsheet.
Page: 2
Permit: WQ0011765 Owner - Facility: Curt P Beeman
Inspection Date: 01/08/2019 Inspection Type : Compliance Evaluation
Permit Status
# Is the current resident in the home the Permittee?
# If not, does the resident rent from the Permittee?
Change of Ownership form needed? (Mail the form with the inspection letter)
# Is there an inspection and maintenance agreement with a contractor?
If YES, who is the contractor (include contact info)?
Permittee maintains the system and contacts manufacturer as needed.
Comment: Chanqe of ownership was not discussed, but form was included with the ins
Sand Filter/Treatment Pods
*** Accessible sand filter surfaces shall be raked/leveled every 6 months and vegetative growth shall be
removed manually. ***
# Is system something other than a sand filter?
# If YES, what kind? (examples - Peat, Textile or brand name - Advantex, etc.)
# Does the permittee know where the sandfilter is located?
Does the sandfilter require maintenance?
If maintenace is required, explain:
Sand filter appeared well maintained. Former permittee created a roof to reduce weather impact and
vegetation growth. An insulated cover is in place to prevent freezing, which may alter spray pattern, but also
eliminates unwanted vegetation.
Comment: NA. See comment above
Disinfection UV
*** UV unit shall be checked weekly. Lamps/sleeves should be cleaned/replaced as needed to ensure
proper disinfection. ***
Is UV working?
Has the UV Unit been serviced and bulbs cleaned?
Reason for Visit: Routine
report.
# Who completes the weekly check for the UV? ( Non -Discharge)
Comment: UV unit was recently replaced and upgrade includes a viewing window for easy inspection.
Pump Tank
*** All pump and alarm sytems shall be inspected monthly. (Non -Discharge) ***
Is the pump working?
Is the audible and visual high water alarm operational?
# Does the permittee know how to check the pump & high water alarm?
# Last functional test:
Yes No NA NE
Yes No NA NE
❑■❑❑
NA - Sand Filter
Yes No NA NE
❑ ❑ ❑
❑ ❑ ❑
Owner
Yes No NA NE
■❑❑❑
Sept 2018 by
manufacturer
representative.
Comment: There are only two adults currently occupying the residence. Per permittee, the tank levels were
assessed in Sept 2018 by system manufacturer during site visit for a minor repair. Tank
residuals were NOT in need of pumping. Annual assessment is recommended.
Page: 3
Permit: WQ0011765 Owner - Facility: Curt P Beeman
Inspection Date: 01/08/2019 Inspection Type : Compliance Evaluation Reason for Visit: Routine
Drip or Irrigation Yes No NA NE
*** Irrigation sysetm shall be inspected monthly to ensure system is free of leaks and equipment is operating
as designed. ***
# Type of system (DRIP or IRRIGATION): Drip
# If IRRIGATION, number of sprinkler heads: NA
Are buffers and setbacks adequate? 0 ❑ ❑ ❑
Is the site free of ponding and runoff? 0 ❑ ❑ ❑
Does the application equipment appear to be working properly? ❑ ❑ ❑
Is there a minimum two wire fence surrounding the entire irrigation area? ❑ 0 ❑ ❑
Comment: Field zones were walked. but aDDlication eauiDment was not reauested to be oDerated due to
recent weather conditions. Two -wire fence is complete on sides that face adjoining properties,
but open on side facing the owner's property.
General Yes No NA NE
# Are the treatment units locked and/or secured? ❑ ❑ ❑
# Has resident had any sewage problems? ❑ ❑ ❑
If YES, explain:
Unit(s) is not locked, but heavy concrete cover is in place
Does the system match the permit description? ❑ ❑ ❑
If NO, explain:
Is the system compliant? ❑ ❑ ❑
Is the system failing? (If yes, take pictures if possible) ❑ ❑ ❑
If system is failing, describe any exposures to people/animals or environmental risks.
NA.
Comment: The application field(s) are in a wooded area which needs typical maintenance for wire -fencing,
removal of small saplings and downed trees and fill dirt for depressions.
This is and older system and does not have a rain -sensor. so Dermittee must monitor system
during inclement weather. There was a small area within Zone 3 that exhibited slight ponding, at
the time of inspection. The application fields appeared in good order given the unusually wet
weather conditions over the past several months. The field sites are slightly upslope from the
owner's yard, which was soft -to -wet, and could be contributing some drainage to that area, but
there was no obvious sign of run-off, at the time of inspection.
Page: 4