HomeMy WebLinkAboutWQ0019095_NOD-2018-PC-0184_20180605Compliance Inspection Report
Permit:WQ0019095 Effective:05/01/15 Expiration:04/30/20 Owner :Colfax Furniture of Greensboro Inc
SOC:
Contact Person:
Region:
County:
Directions to Facility:
Guilford
Winston-Salem
Jackie Landreth
Effective:Expiration:Facility:Colfax Furniture
2361 Campground Rd
Greensboro NC 27406
Title:Phone:336-852-3053President
From WSRO, take I-40 east to High Point Rd. exit (217). Turn rt. at top of ramp onto High Point Road. Turn left on Holden Rd. After
crossing over I-85, turn rt. onto Campground Road. Turn left onto Viewmount Road. Colfax Furniture Warehouse on left.
Secondary ORC(s):
Phone:Certification:Primary ORC:
SI,System Classifications:
On-Site Representative(s):
Related Permits:
Secondary Inspector(s):
Primary Inspector:
Inspection Date:Exit Time:Entry Time:
Phone:
05/01/2018 03:04PM 05:30PM
Rebecca D Chandler 336-776-9692
Facility Status:
Permit Inspection Type:
Reason for Inspection:Inspection Type:
Not CompliantCompliant
Routine
Wastewater Irrigation
Compliance Evaluation
Question Areas:
Treatment Flow Measurement-Effluent Treatment Flow Measurement-Influent Miscellaneous Questions
Treatment Flow Measurement-Water
Use Records
Treatment Treatment Filters
Record Keeping Treatment Lagoons Treatment Sludge Storage/Treatment
End Use-Irrigation Treatment Influent Pump Station Treatment Clarifiers
Treatment Disinfection Treatment Flow Measurement Treatment Return pumps
(See attachment summary)
Page:1
Inspection Date:
Permit:
Inspection Type :
Owner - Facility:
Reason for Visit:
WQ0019095
05/01/2018 Compliance Evaluation
Colfax Furniture of Greensboro Inc
Routine
Inspection Summary:
An annual compliance evaluation was completed on 05/01/2018 by DWR staff person Rebecca Chandler. DWR staff
completed the inspection with Mr. Fred Thomen, ORC of the subject facility.
Residuals in septic tank were noted high and pumping of the septic tank is recommended.
Current ORC (Fred Thomen) is not listed in DWR’s system as the facility’s ORC. DWR staff provided ORC designation form
and asked that a back-up ORC certified for wastewater drip irrigation be designated as well ASAP.
NDMR/NDAR self-monitoring data from 01/2017 and 01/2018 was not received by DWR. It was provided during the
inspection.
DWR staff was to check with front office for an O&M plan and Spill plan but ran out of time during the inspection. Check next
visit, and check for design specs for the stream crossing pipe-work.
A direct discharge to surface waters was observed during the inspection. The discharge originated at the stream crossing
coming from the rip-rap covering on the hill-slope. DWR staff noted an odor prior to observing the wastewater discharge.
ORC immediately uncovered the suspected leak from rip-rap material. Discharge was determined to be from a split elbow
pipe fitting. The system was running due to prior testing of the floats and alarm system as a part of the compliance
inspection. It was unclear how long the problem had existed. There was some algal growth in the stream, but live fish were
observed downstream. It is estimated that the system pumps over to the irrigation station (and thus through the stream
crossing piping) 2 to 3 times a day, approximately 166 gallons/day total, with about 50-75% of the water going all the way to
the storage tank for irrigation. The system was turned off immediately and locked out from being turned back on until repairs
could be made. ORC made temporary repairs the night of the inspection, and completed the repairs the following day when
proper materials could be purchased. ORC provided thorough information, photos, and updates as repairs were made to
DWR staff. DWR staff suggested finding a way to test the rest of the system to prevent future discharges (i.e. pressure
testing).
DWR staff observed irrigation system, sand filter, and zone 3 dosing. No leaks were noted in irrigation field, and sand filter
was well maintained.
Page:2
Inspection Date:
Permit:
Inspection Type :
Owner - Facility:
Reason for Visit:
WQ0019095
05/01/2018 Compliance Evaluation
Colfax Furniture of Greensboro Inc
Routine
Type Yes No NA NE
Single Family Spray, LR
Recycle/Reuse
Single Family Drip
Activated Sludge Spray, LR
Reuse (Quality)
Activated Sludge Spray, HR
Lagoon Spray, LR
Infiltration System
Activated Sludge Drip, LR
Treatment Yes No NA NE
Are Treatment facilities consistent with those outlined in the current permit?
Do all treatment units appear to be operational? (if no, note below.)
See inspection summary.Comment:
Treatment Influent Pump Station Yes No NA NE
Is the pump station free of bypass lines or structures?
Is the general housekeeping acceptable?
Are all pumps present?
Are all pumps operable?
Are floats/controls operable?
Are audio and visual alarms available?
Are audio and visual alarms operational?
# Are SCADA/Telemetry alarms required?
Are SCADA/Telemetry available?
Are SCADA/Telemetry operational?
See inspection summary.Comment:
Treatment Flow Measurement-Influent Yes No NA NE
Is flowmeter calibrated annually?
Is flowmeter operating properly?
Does flowmeter monitor continuously?
Does flowmeter record flow?
Does flowmeter appear to monitor accurately?
Comment:
Treatment Flow Measurement-Water Use Records Yes No NA NE
Page:3
Inspection Date:
Permit:
Inspection Type :
Owner - Facility:
Reason for Visit:
WQ0019095
05/01/2018 Compliance Evaluation
Colfax Furniture of Greensboro Inc
Routine
Is water use metered?
Are the daily average values properly calculated?
Comment:
Treatment Flow Measurement-Effluent Yes No NA NE
Is flowmeter calibrated annually?
Is flowmeter operating properly?
Does flowmeter monitor continuously?
Does flowmeter record flow?
Does flowmeter appear to monitor accurately?
Comment:
Treatment Clarifiers Yes No NA NE
Are the weirs level?
Are the weirs free of solids and algae?
Is the scum removal system operational?
Is the scum removal system accessible?
Is the sludge blanket at an acceptable level?
Is the effluent from the clarifier free of excessive solids?
Comment:
Treatment Return pumps Yes No NA NE
Are they in place?
Are they operational?
Comment:
Treatment Filters Yes No NA NE
Is the filter media present?
Is the filter media the correct size and type?
Is the air scour operational?
Is the scouring acceptable?
Is the clear well free of excessive solids?
Is the mud well free of excessive solids and filter media?
Does backwashing frequency appear adequate?
Comment:
Treatment Sludge Storage/Treatment Yes No NA NE
Is the aeration operational?
Is the aeration pattern even?
If required, are Sanitary "Ts" present in tankage?
Page:4
Inspection Date:
Permit:
Inspection Type :
Owner - Facility:
Reason for Visit:
WQ0019095
05/01/2018 Compliance Evaluation
Colfax Furniture of Greensboro Inc
Routine
Comment:
Treatment Disinfection Yes No NA NE
Is the system working?
Do the fecal coliform results indicate proper disinfection?
Is there adequate detention time (>=30 minutes)?
Is the system properly maintained?
If gas, does the cylinder storage appear safe?
Is the fan in the chlorine feed room and storage area operable?
Is the chlorinator accessible?
If tablets, are tablets present?
Are the tablets the proper size and type?
Is contact chamber free of sludge, solids, and growth?
If UV, are extra UV bulbs available?
If UV, is the UV intensity adequate?
# Is it a dual feed system?
Does the Stationary Source have more than 2500 lbs of Chlorine (CAS No. 7782-50-5)?
If yes, then is there a Risk Management Plan on site?
If yes, then what is the EPA twelve digit ID Number? (1000-____-____)
If yes, then when was the RMP last updated?
Comment:
Record Keeping Yes No NA NE
Is a copy of current permit available?
Are monitoring reports present: NDMR?
NDAR?
Are flow rates less than of permitted flow?
Are flow rates less than of permitted flow?
Are application rates adhered to?
Is GW monitoring being conducted, if required (GW-59s submitted)?
Are all samples analyzed for all required parameters?
Are there any 2L GW quality violations?
Is GW-59A certification form completed for facility?
Is effluent sampled for same parameters as GW?
Do effluent concentrations exceed GW standards?
Are annual soil reports available?
# Are PAN records required?
# Did last soil report indicate a need for lime?
Page:5
Inspection Date:
Permit:
Inspection Type :
Owner - Facility:
Reason for Visit:
WQ0019095
05/01/2018 Compliance Evaluation
Colfax Furniture of Greensboro Inc
Routine
If so, has it been applied?
Are operational logs present?
Are lab sheets available for review?
Do lab sheets support data reported on NDMR?
Do lab sheets support data reported on GW-59s?
Are Operational and Maintenance records present?
Were Operational and Maintenance records complete?
Has permittee been free of public complaints in last 12 months?
Is a copy of the SOC readily available?
No treatment units bypassed since last inspection?
See inspection summary.Comment:
End Use-Irrigation Yes No NA NE
Are buffers adequate?
Is the cover crop type specified in permit?
Is the crop cover acceptable?
Is the site condition adequate?
Is the site free of runoff / ponding?
Is the acreage specified in the permit being utilized?
Is the application equipment present?
Is the application equipment operational?
Is the disposal field free of limiting slopes?
Is access restricted and/or signs posted during active site use?
Are any supply wells within the CB?
Are any supply wells within 250' of the CB?
How close is the closest water supply well?
Is municipal water available in the area?
# Info only: Does the permit call for monitoring wells?
Are GW monitoring wells located properly w/ respect to RB and CB?
Are GW monitoring wells properly constructed, including screened interval?
Are monitoring wells damaged?
Comment:
Page:6