HomeMy WebLinkAboutNC0003760_Corrective Action Plan_20190401 - . 4 OUpoNT DuPont Kinston Plant ' 4693 Hwy. 11 North Grifton,NC 28530 April 1,2019 CERTIFIED MAIL: 7016 2710 0000 0959 4986 RETURN RECEIPT REQUESTED �NRI�WR2019 NC Division of Water Resources Ar NPDES Complex Permitting Unit RECE%JE�U d 1 - 1617 Mail Service Center Water Resources Raleigh,NC 27699-1617 p®rm►t'.k►9 Section Re: Permit No.NC0003760: A. (13) Schedule of Compliance Total Copper, Total Lead, Total Silver, and Total Zinc Outfalls 002& 003 Year 2 Summary Report& CAP. The following compliance aspects were addressed during the second year of the 5-year compliance schedule. a) Document any identified sources of the Total Copper, Total Lead, Total Silver, and Total Zinc: Since the plant is not manufacturing any chemicals or using any raw materials with heavy metals,the site's investigation focused on the infrastructure of the site. The site started manufacturing polyester fibers,polyethylene terephthalate(PET) in 1953 and 66 years later,the site continues to manufacture poly trimethylene terephthalate (PTT) a polyester polymer. The site's large infrastructure is constructed of materials that contain zinc, lead, and copper and many of these buildings have deteriorated. A major effort and significant investment for demolition and removal (D&R)of obsolete equipment,piping, tanks and buildings was initiated 2 years ago and continues through 2019. In addition to the D&R work at the site,most of the remaining galvanized steel buildings have been painted to inhibit additional corrosion. b) Submit a report summarizing the identified pollutant sources and source reduction alternatives that were investigated: The site's age and infrastructure is contributing to the sources of zinc, copper and lead. Outfall 002 receives waters from the heart of the manufacturing area, where two main stormwater trunks direct water down from buildings (roofing, siding, downspouts) piping, and tanks through the outfall. The catch basins contributing to outfall 002,will be cleaned out(CAP task)to remove accumulated material. A walk-through audit of outfall 002 identified 4-galvinized steel culverts that are corroded through at the bottom and being washed out from erosion. A capital project was funded to have all 4 culverts removed from the outfall; eliminating this potential source of zinc. This project will be completed by mid-year 2019. A grassed swale was constructed for outfall 004 several years ago to address zinc containing runoff from the aging warehouses near that outfall. After the grassed swale was installed the warehouses (over 100,000 square feet)were D&R'd. The site would propose a grassed swale BMP be installed at outfall 002 as part of the site's CAP (see Figure 1, CAP). Outfall 003, collects stormwater flows from the front of the site is not impacted by our manufacturing of PTT. Roofing, siding, downspouts, and other infrastructure materials contribute to the metals in the stormwater runoff. DuPont Industrial Biosciences USA,LLC Page 1 of 2 j r The catch basins contributing to outfall 003, will be cleaned out(CAP task)to remove accumulated material. To collect a more representative sample at outfall 003,the site proposes to move the monitoring location to a new location further downstream of the current monitoring location(see Figure 2 CAP). c) Submit a Corrective Action Plan (CAP): See Attached. As the site closes out year two of the five-year compliance schedule, we will continue study our stormwater as we work to achieve each milestone in our CAP over the next three years. If you have any questions,please contact Jon Carpenter, Environmental Manager at 252-522-6255 Sincerely, orge en is Plant Mana er DuPont Kinston Plant E.I.DuPont de Nemours and Company Page 2 of 2 r DUPONT 4693 Hwy 11 N NPDES Permit No. NC0003760 Grifton, NC 28530 DuPont Industrial Biosciences USA, LLC April 1, 2019 STORMWATER CORRECTIVE ACTION PLAN (CAP) This Stormwater Corrective Action Plan (Table 1) has been developed in conjunction with A. (13) Schedule of Compliance Total Copper, Total Lead, Total Silver, and Total Zinc for Outfalls 002&003 to address compliance with the new lower limits for metals copper, lead,silver, and zinc for the two (Outfalls 002 &003) combined process/stormwater discharges at DuPont—Kinston Facility, National Pollutant Discharge Elimination System Permit No. NC0003760.The schedule included in this Plan provides a means for NCDEQ to assess the progress being made on each milestone. Table 1: Overall Schedule TASK MILESTONES COMPLETION DATES NCDEQ ACTION Phase 1 (Year 1&2) Review new permit May 2017 Issued NPDES permit limits and effective on April 1, requirements and 2017 develop the CAP Review and update, as Audit Tradewaste Lab July 2017 needed,the sampling procedures and sample techniques used by methods ORC. Confirm with outside, Confirmed December 2017 certified lab on their Environment 1, sample handling Incorporated is techniques certified to handle all our stormwater sampling requirements Verify Smoking Policy Confirmed site policy is March 2018 for DuPont at the written in the Sorona Kinston Site Safety Manual,Section 2, Item 200, Rule#2 Select additional Collect samples near May 2017 sampling locations buildings and process above the actual and compile the monitoring point for additional data outfalls 002 &003 Submit summary Summarize year 1 April 1, 2018 Certified Mail signed report to Div. of Water schedule of compliance return receipt for the Resources A. (13.) summary letter. (March 27, 2018) Sampling events March 2019 April 1, 2018 throughout year 1 and year 2 Page 1 of 4 OUPONT! 4693 Hwy 11 N NPDES Permit No. NC0003760 Grifton, NC 28530 TASK MILESTONES COMPLETION DATE NCDEQ ACTION Summarize findings Provide summary with April 2019 and conditions letter and CAP to Div. contributing metals to of Water Resources outfalls 002 &003 Confirm cooling chilled, ChemTreat SDS: No January 2019 and Boiler water metals listed in any of treatment chemicals the treatment don't contain metals chemicals Research possible Based on data,select March 2019 BMPs BMP(s)to improve water quality Meet with Kinston site Staff meeting March March 26, 2019 Leadership to present 26, 2019 led by Plant data and Manager recommendations for improvements Submit summary Certified mail cover April 1, 2019 report (with CAP)to letter and CAP Div. of Water according to A. (13.) Resources Year 2 Phase 2(Year 3&4) Pending approval of Receive CAP approval Corrective Action Plan from Div. of Water (CAP)from NCDEQ, Div. Resources of Water Resources Clean out any Complete basin sentiment found in the cleanout project by End stormwater catch of Summer 2019 basins along the flow of outfalls 002&003 Consult with Supplier Seek supplier data on and test for impact of impact of water water treatment treatment chemicals chemicals on the and sample treated infrastructure water for metals Continue sampling Sample during the fall Outfalls 002 &003 of 2019 above the above sample location monitoring point for after cleaning out of each outfall stormwater catch basins Request Engineering to Receive engineered Request Engineering to design Grassy Swale plan to construct design Grassy Swale BMP for Outfall 002 Grassy Swale BMP BMP for Outfall 002 (see Figure 1.) (see Figure 1.) Page 2 of 4 0UPON1! 4693 Hwy 11 N NPDES Permit No. NC0003760 Grifton, NC 28530 TASK MILESTONES COMPLETION DATE NCDEQ ACTION Develop SOC for new SOC Complete monitoring point for Outfall 002 (see Figure 2.) Develop Scope of Work Scope of Work to establish new complete monitoring point for Outfall 003 Seek Funding to move Funding approved for monitoring point to new monitoring point new location at Outfall for Outfall 003 003 Select Contractor& PO issued to contactor Request Purchase to construct new Order(PO)to construct monitoring location for the new monitoring Outfall 003 point on Outfall 003 Submit summary Summarize year 3 Due by April 1 2020 report to Div. of Water schedule of compliance Resources A. (13.) Construct Grassy Swale Complete Construction BMP at Outfall 002 Project Install new Monitoring Complete Installation Point at Outfall 003 Project Submit summary Summarize year 4 Due by April 1,2021 report to Div. of Water schedule of compliance Resources A. (13.) Phase 3(Year 5) Prepare separate Submittal of NPDES Due no later than NPDES Permit Permit application September 30,2021 application (180 days prior to expiring) Prepare separate Submittal of Due no later than Stormwater Permit Stormwater Permit September 30, 2021 application application (180 days prior to expiring) NPDES Permit review Receive approval of TBD (Permit expires at Pending issuance of and approval by NC new NPDES Permit midnight March 31, new NPDES Permit Div. of Water 2022) Resources-NPDES Stormwater Permit Receive approval of TBD(Permit expires at Pending issuance of review and approval by new Stormwater midnight March 31, new Stormwater DEMLR Stormwater Permit 2022) permit Page 3 of 4 1 4OUPONT! 4693 Hwy 11N NPDES Permit No. NC0003760 Grifton, NC 28530 Submit summary Summarize year 5 Due by April 1, 2022 report to Div.of Water schedule of compliance Resources A.(13.) Figure 1: Proposed BMP: Grassed Swale Cooling Tower \e Dismantled Goa and Removed ayyed \\p0� (2018) G , c Ea J 00e O ed 0613 • Figure 2: Proposed site for new sampling location. Proposed New Sampling P P 9 Location Outfall 003 Sampling Location Google Page 4 of 4