Loading...
HomeMy WebLinkAboutNCS000294_COMPLIANCE_20090909_-STORMWATERTDIVISION-CODING-SHEET'--'� PERMIT NO. DOC TYPE ❑ FINAL PERMIT ❑ MONITORING INFO ❑ APPLICATION P COMPLIANCE ❑ OTHER DOC DATE 00109 YYYYM M DD NCDERR .�. North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Governor Director Mr. David Bissette Southern States Cooperative, Inc. 2089 Sam Moss Road Creedmoor, NC 27522 Subject: Compliance Evaluation Inspection Stormwater NPDES Permit NCS000294 Southern States Cooperative Creedmoor, NC Granville County Dear Mr. Bissette: On September 3, 2008, Dave Parnell of the Raleigh Regional Office of the Division of Water Quality, performed a compliance evaluation inspection (CEI) at Southern States' fertilizer mixing and loading facility. Your assistance was appreciated. This inspection was conducted to determine the facility's compliance with its NPDES stormwater permit. Observations during the inspection are as follows: Dee Freeman Secretary 1. Although you stated there had been no significant spills in the last three years, there was no list of significant spills contained within the Stormwater Pollution Prevention Plan (SP3) as required by your permit. Please include a section tab and list of significant spills within the SP3. 2. The SP3 had not been reviewed and updated during the calendar year as required. The site map had not been updated to reflect the change from three (3) stormwater discharge outfalls (SDO) to two (2) SDO, which was agreed upon during the January Ib, 2008 CEI. Please update the Stormwater Pollution Prevention Plan during the current calendar year. 3. Documented records of employee training were contained within the SP3, as required by the permit. 4. Qualitative and analytical monitoring are required semi-annually by the permit. We discussed and you have documented, the difficulty in meeting the analytical monitoring requirements set forth by the permit. When the rainfall conditions have been present, and the timing of sampling and lab scheduling met, the monitoring requirements were achieved. However; sample results show total phosphorous levels to be above the'allowable benchmark. Implement an effort to reduce dust, reduce the deposits of fertilizer on equipment and tires and any other housekeeping measures, arp' ra urat; North Carolina Division of Water Quality Raleigh Regional Office Surface Water Protection Phone (919) 791-4200 Customer Service lntemet: www,ntwaterqualily,org 1628 Mail Service Center Raleigh, NC 27699-1628 FAX (919) 571-4718 1-877-623-6748 An Equal CpportunilylAOlrrnative Action Employer— 50% Recycled110% Post Consumer Paper w southern States Cooperative, Inc. • Page 2 in an attempt to decrease the total phosphorous levels. Failure to conduct the fall 2008 qualitative monitoring was discussed with you during the inspection. You have shown that this was an oversight by conducting the required periodic inspection in 2009. 5. All Stormwater Discharge Outfalls (SDO) were inspected, as was secondary containment. All were found to be in compliance. This facility is considered to be neither compliant nor non -compliant at this time. Please provide a written response to this letter, within 30 days of the receipt of this letter, detailing the facility's compliance efforts with respect to the bold items in #1, #2, and #4. If you have any questions regarding the attached report or any of the findings, please contact me at: (919) 791-4200 (or email: david.parnell(ci)ncmail.net). Sincerely, z At,� Dave Parnell Environmental Specialist Surface Water Protection Section Enclosure: August 3, 2009 Compliance Evaluation Inspection cc: RRO/SWP files Water Quality Central Files Compliance Inspection Report Permit: NCS000294 Effective: 03/01/06 Expiration: 02/28/10 Owner: Southern States Cooperative Inc SOC: Effective: Expiration: Facility: Southern States Coop-Creedmoo County: Granville 2089 Sam Moss Rd Region: Raleigh Creedmoor NC 27522 Contact Person: David Bissette Title: Phone: 919-528-1516 Directions to Facility: System Classlficatlons: Primary ORC: Certiflcatlon: Phone: Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 09/03/2009 Entry Time: -10:45 AM Exit Time: 12:00 PM Primary Inspector: David R Parnell Phone: 919-791-4260 Secondary Inspector(s): Reason for Inspection: Routine Permit Inspection Type: Stormwater Discharge, Individual Facility Status: ❑ Compliant ❑ Not Compliant Question Areas: 0 Storm Water (See attachment summary) Inspection Type: Compliance Evaluation u Page: 1 4 Permit: NCS000294 Owner - Facility: Southern States Cooperative Inc Inspection Date: 09/0312009 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: Page: 2 Permit: NCS000294 Owner - Facility: Southern States Cooperative Inc Inspection Date: 09/03/2009 Inspection Type: Compliance Evaluation Reason for visit: Routine Stormwater Pollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan? ■ ❑ ❑ ❑ # Does the Plan include a General Location (USGS) map? ■ ❑ ❑ ❑ # Does the Plan include a "Narrative Description of Practices"? ■ ❑ ❑ ❑ # Does the Plan include a detailed site map including outfall locations and drainage areas? ■ Cl ❑ ❑ # Does the Plan include a list of significant spills occurring during the past 3 years? ❑ ❑ ❑ ■ # Has the facility evaluated feasible alternatives to current practices? ■ ❑ ❑ ❑ # Does the facility provide all necessary secondary containment? ■ ❑ ❑ ❑ # Does the Plan include a BMP summary? ■ ❑ ❑ ❑ # Does the Plan include a Spill Prevention and Response Plan (SPRP)? ■ ❑ ❑ ❑ # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? ■ ❑ ❑ ❑ # Does the facility provide and document Employee Training? ■ ❑ ❑ ❑ # Does the Plan include a list of Responsible Party(s)? ■ ❑ ❑ ❑ # Is the Plan reviewed and updated annually? ❑ ■ ❑ ❑ # Does the Plan include a Stormwater Facility Inspection Program? ■ ❑ ❑ ❑ Has the Stormwater Pollution Prevention Plan been implemented? ❑ ❑ ❑ ❑ Comment: Include in SP3 the list of significant spills, although none were reported verbally, the Division suggests. that a list be a part of the plan, in order to be readily available. The SP3 should be reviewed and updated annually, the site plan should reflect the fact that only 2 SDOs are now being evaluated rather than 3. This change was made January 16, 2008 by Myrl Nisely. Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring semi-annually? ■ ❑ ❑ ❑ Comment: Neglected to conduct the Fall '08 required qualitative monitoring. Analytical Monitoring Yes No NA WE Has the facility conducted its Analytical monitoring? 00013 # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? ❑ ❑ ■ ❑ Comment: David Bissete is having difficulty with "the rules, parameters and tab schedules, and the timing and frequency of rainfall events" and therefore has been unable to meet the requirements in taking the proper sample. The sample reports that he did have were evaluated during the inspection. Total Phosphorus readings were elevated: 22.8, Benchmark = 2. Permit and Outfalls Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? 0000 Page: 3 • 0 Permit: NCS000294 Owner -Facility, Southern States Cooperative Inc Inspection Date: 09/03/2009 Inspection Type: Compliance Evaluation Reason for Visit: Routine # Were all outfalls observed during the inspection? ■ ❑ ❑ ❑ # If the facility has representative outfall status, is it properly documented by the Division? ❑ ■ ❑ ❑ # Has the facility evaluated all illicit (non stormwater) discharges? ■ ❑ ❑ ❑ Comment: Page: 4 xon�,� f?" 9 its{ Lro '� If+r'11 a `- Sslf��� R��sr� i' raja � ^b� ��i✓ c7 t�t'tf '� �r`�l� ���1� ''� � L�J� i J � l r� �� � � �'I • t, .j`'U�.}.. r !J � '-�1 � • 0 of �� I r • �:i,r - �;i)1lJ/1�� ,�� �i'7(r i;� '//'/�',,f�i � � _5'r}' 2 .� ��' r ��//ff � irk � � U"d dam/ }�� 'I �levvPro (r ,rya . ti 1 a }��€I 2i� ll"F �/ ' rr � f � ll r gr�--Op� I ke-v"Y?�� g, 7--q- ��A - * -6W A-6 9 �' 7 yi rnwv°�r - 0-/-! 0 jo 46 0• •! 00 00 Ja6q. -�j -,2-OzI File 301 /1. SY r. /2 751Q-2. 2,q) Ral I O-A ell k Wry\,e-i d- of WAIF, i r0� PGi� r 7 � Q 'C Mr. David Bissette, Southern States Cooperative 2089 Sam Moss Rd. Creedmoor, NC 27522 00 January 18, 2008 Michael F. Easley, Governor William G. Ross, Jr., Secretary North Carolina Department of Environment and Natural Resources 1 SUBJECT: , Compliance Evaluation Inspection Report Southern States Cooperative Stormwater NPDES Permit NCS000294 Creedmoor, NC Granville County Dear Mr, Bissette: Coleen H. Sullins, Director Division of Water Quality On January 16, 2008 I (Myr] Nisely) made a compliance inspection of the Southern States warehouse facility with your help. It was a pleasure meeting you. The fertilizer mixing and loading facility was in compliance. Please see the attached inspection checklist. Below are a few highlights from our discussion. 1. The Stormwater Pollution Prevention Plan (SP3) was current except for evidence of employee training. The home office of Southern States has oversight of the program, including revisions to the an at. However, you are urged to document an annual update of the SP3, as well. 2. _ Wk>. e not a requirement from DWQ, placing the SP3 and documents created from sampling, qualitative inspections and employee training into a 3-ring binder would provide a central repository of information. A manual organized in that way usually helps a permittee carry out the permit requirements more completely and also expedites our inspections. These records are to be kept for five years, as stated in the permit. 3. Employee training has been covering spill response, but stormwater awareness should be added. Browsing through topics on http://www.ncstormwater.orgZpages/sitemappa eg html may be helpful. Speaking points for training sessions are offered at http://-www.ncstortnwater.org pages/sitemappage.html. 4. Sampling is now required twice a year in your latest permit on a specific schedule. Because of the drought in 2007, the only sampling was done in May. Near year's end, you had provided proper notification to our Central Office explaining the absence of a second round of sampling. The May results for all outfalls were below the benchmark levels stated in the pen -nit. 5. Observations of conditions around the loading areas and the good analytical indicators mentioned above indicate that measures taken after the last inspection to reduce dust and other handling losses of fertilizer are effective. One N,,ppr hCaro ina North Carolina Division of Water Quality Raleigh Regional Office Surface Water Protection Phone (919) 791-4200 Customer Service Internet www.ncwalerqualitv.ore 1628 Mail Service Center Raleigh, NC 27699-1628 FAX (919) 788-7159 1-877-623-6748 An Equal OpportunitylANirmative Action Employer— 50% Recycled110% Post Consumer Paper Southern States Coop CEI, January 16,2008 Page 2 02 6. pH is measured at the contra4c aboratory, so is not measured whin a0minute hold time. To be done correctly, pH is a field measurement made when the samples are collected. Information on a variety of pH meters may be found by searching "ph meter" online. The meter should be capable of automatic temperature compensation. In addition to the pH, temperature is to be recorded, too. Before use on a given day, the meter should be calibrated using buffer solutions. The calibration is to be documented as part of the analytical report for that sampling round. Finally, to keep the probe operational the next time a pH is needed, proper storage of the probe in a �41XICIPYImmend � solution must be done. Otherwise, the probe will dry out and fail to function the next time. 7. The flow of rainwater to "Outfall 2" spreads into a wide grassy area as sheet flow. No further sampling at this location will be required. If you have questions or comments about this inspection, please contact me at 919-791-4255. Sincerely, Myrl X Nisely Environmental Chemist Raleigh Regional Surface Water Quality cc: RRO/SWP files Central Files • • V • Compliance Inspection Report Permit: NCS000294 Effective: 03/01/06 Expiration: 02/28/10 Owner: Southern States Cooperative Inc SOC: Effective: Expiration: Facility: Southern States Coop-Creedmoo County: Granville 2089 Sam Moss Rd Region: Raleigh Creedmoor NC 27522 5 Contact Person: David Bissette Title: Phone: 919-528-1516 Directions to Facility: System Classifications: Primary ORC: Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 01116/2008 Primary Inspector: Myra Nisely Secondary Inspector(s): Entry Time: 01:35 PM Reason for Inspection: Routine Permit Inspection Type: Stormwaler Discharge, Individual Facility Status: ❑ Compliant ❑ Not Compliant Question Areas: E Storm Water (See attachment summary) Certification: Phone: Exit Time: 03:00 PM Phone: 919-791-4200 Inspection Type: Compliance Evaluation Page: 1 00 00 I Permit: NCS000294 Owner - Facility: Southem States Cooperative Inc Inspection Date: 01/16/2008 Inspection Type: Compliance Evaluation Reason for Visit: Routine Stormwater Pollution Prevention Plan Yes No NA NE i Does the site have a Stormwater Pollution Prevention Plan? ■ ❑ 1113 # Does the Plan include a General Location (USGS) map? ■ ❑ ❑ ❑ # Does the Plan include a "Narrative Description of Practices"? ■ ❑ ❑ ❑ # Does the Plan include a detailed site map including outfall locations and drainage areas? ■ ❑ ❑ ❑ # Does the Plan include a list of significant spills occurring during the past 3 years? ■ ❑ ❑ ❑ # Has the facility evaluated feasible alternatives to current practices? ■ ❑ ❑ ❑ # Does the facility provide all necessary secondary containment? ■ ❑ ❑ ❑ # Does the Plan include a BMP summary? ■ ❑ ❑ ❑ # Does the Plan include a Spill Prevention and Response Plan (SPRP)? ■ ❑ ❑ ❑ # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? ■ ❑ ❑ ❑ # Does the facility provide and document Employee Training? ❑ ■ ❑ ❑ # Does the Plan include a list of Responsible Party(s)? ■ ❑ ❑ ❑ # Is the Plan reviewed and updated annually? ■ ❑ ❑ ❑ # Does the Plan include a Stormwater Facility Inspection Program? ■ ❑ ❑ ❑ Has the Stormwater Pollution Prevention Plan been implemented? ■ ❑ ❑ ❑ Comment: Employees receive spill response training, but not stormwater specific training. The inspector was asked to identify training aids for future employee training. Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring semi-annually? ■ ❑ ❑ ❑ Comment: Analytical Monitoring Yes No NA NE Has the facility conducted its Analytical monitoring? ■ ❑ ❑ ❑ # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? ■ ❑ ❑ ❑ Comment: Because of drought conditions, only one sampling round was possible in 2007, in May. Values for all three outfalis were less than benchmark values. There is a need to be able to measure pH in the field within the 15 minute hold time. Permit and Outfalls Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? ■ ❑ ❑ ❑ # Were all outfalls observed during the inspection? ■ ❑ ❑ ❑ # If the facility has representative outfall status, is it properly documented by the Division? ❑ ❑ ■ ❑ # Has the facility evaluated all illicit (non stormwater) discharges? ■ ❑ ❑ ❑ . Page: 3 t ti 00 Permit: NCS000294 Owner -Facility: Southern States Cooperative Inc Inspection pate: 01/16/2008 Inspection Type: Compliance Evaluation Reason for Visit: Routine Comment: Outfali #2 serves a small watershed, and the flow spreads before it runs into dense grass as sheet flow. This outfall can be removed from the stormwater plan. Page: 4 F W A TF Michael F, Easley, Governor 0 ApG William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Raleigh Regional Office -i p Y Alan W. Klimek, P.E. Director Division of Water Quality November 22, 2005 Mr. David Bissette Southern States P.O. Box 582 Creedmoor, NC 27522 Subject: Inspection Report Southern States — Creedmoor NCS000294 Granville County Dear Mr. Bissette: On Thursday, November 10, 2005, I conducted a compliance evaluation inspection at the subject facility. This visit was conducted in conjunction with the review of your application for continued coverage under individual stormwater permit number NCS000294. Your assistance during the inspection was very helpful and was appreciated. Below are the findings and recommendations from the site visit. The site is a fertilizer distribution center. No manufacturing takes place on site. All products are stored inside a building (except for one lime pile). 2. A review of the facility's records was conducted. The facility has records of all analytical and qualitative monitoring conducted for the last five years. Several readings for ammonia and nitrates were notably high from outfall 001 and outfall 003. Outfall 001 drains the west side of the fertilizer building and the south side of the building where bulk fertilizer is brought in and transferred into the building. Outfall 003 drains the east side of the fertilizer storage building including the area where fertilizer is loaded onto delivery trucks. 3. General housekeeping around most of the property was good. Some fertilizer residue was noted around the area where bulk fertilizer is brought in and loaded into the storage area. Pictures of this area are attached for reference, This is likely the cause of the elevated nitrogen readings from outfall 001. We discussed Southern States evaluating ways to reduce the nitrogen loss from that area including covering the loading conveyer system. Raleigh Regional Office 1628 Mail Service Center phone (919) 571-4700 Customer Service Water Quality Section Raleigh, NC 27699-1628 facsimile (919) 571-4718 1-877-623-6748 +ram. As*� ,lqcbE- R R • i t�. Southern States NCS000294 November 28, 2005 Page 2 of 2 4. Some fertilizer dust was being blown onto the grounds in the breezy conditions as a truck was being loaded for delivery. Southern States agreed to evaluate the use of some kind of synthetic "sock" or other device on the end of the conveyer belt that loads delivery trucks to prevent dust from and fertilizer from escaping onto the property. 5. The facility's new permit will contain "benchmark values" which will give you an idea of when you need to check the effectiveness of your BMP's and/or review and update your Stormwater pollution prevention plan. Please respond within 30 days of your receipt of this letter with information detailing your evaluation ways to reduce the nutrient loss from the areas surrounding the incoming and outgoing fertilizer load areas. If you have any questions or if I can be of any assistance please feel free to call me at (919) 791-4200. ySincerelon Langley 14 Environmental Specialist H Cc: RRO Files Central Niles Bethany Georgoulias ,r 0 0 Southern States S000294 November 28, 2005 Page 3 of 3 Area where fertilizer is brought in and loaded into the storage building. Note some fertilizer 1 / 10/2005 Relation of loading area to storm drain leading to outfall 001, NCS000294 11/10/2005