Loading...
HomeMy WebLinkAboutWQCS00149_NOV-2019-DV-0060 Response_20190211RECEIVEDINCOENROWR FEB 11 2019 WQROS MOORESVILLE REGIONAL OFFICE FOR n.,,. l2c COUNTY OF LINCOLN, NORTH CAROLINA TH CAR°V 115 WEST MAIN STREET, 2NO FLOOR CITIZENS CENTER, LINCOLNTON, NORTH CAROLINA 28092 DEPARTMENT OF PUBLIC WORKS PHONE (704) 736-8497 FAX (704)736-8499 NCDEQ Water Resources Water Quality Regional Operations Section Attn: W. Corey Basinger Regional Supervisor 610 East Center Avenue, Suite 301 Mooresville, NC 28115 Ref: Notice of Violation & Intent to Issue Civil Penalty Tracking No.: NOV-2019-DV-0060 Dear Mr. Basinger, I am writing in response to the Notice of Violation & Intent to Issue a Civil Penalty (NOV-2019- DV-0060). The SSO at Pump Station #12, 2460 NC Hwy 16 North Business, that occurred on September 10, 2018 was a result of a pump malfunction, electrical shorting of several wires and tripping the control breaker, which resulted in a loss of power on the 110 volt circuit for control power. The Auto Dialer was connected to the 110 volt circuit and failed to identify the problem and contact Lincoln County Public Works (LCPW). The Pump Station #12 was last checked (weekly check) on September 5, 2018 and was operating normally at that time. Once LCPW was notified that there was an SSO, Lincoln County Staff arrived on -scene, identified the problem, replaced the shorted wires, and reset the breaker; this allowed Pump 41 to operate and the SSO was stopped immediately. LCPW then installed a spare pump from inventory and cleaned up any sewage that was pooled on the ground. The Auto Dialer was also replaced and tested with no issues. Lincoln County Public Works will continue to work diligently to fully comply with our NCDEQ Permit #WQCS00149. We also ask that you would consider the following: 1. The spill did not reach any surface water. 2. Public Works Staff worked quickly to stop the SSO. 3. There was no impact to Public Health. 4. There were no fish kills. 5. No recreational areas were closed as a result of the SSO. J2`o�LT�- a COUNTY OF LINCOLN, NORTH CAROLINA ry 'CAAa�� 1 1 S WEST MAIN STREET, 2ND FLOOR CITIZENS CENTER, LINCOLNTON, NORTH CAROLINA 28092 DEPARTMENT OF PUBLIC WORKS PHONE (704)736-8497 FAX (704) 736-8499 6. The spill was a result of a mechanical failure. 7. Quick Response by Public Works Staff and reporting to Mooresville NCDEQ staff. The attached SSO Report and the above details are offered for your consideration in this important matter. Cordially, Donald V. Chamblee Director of Public Works 115 W. Main St. Lincolnton NC 28092 dchamblee@lincolncounty.org CERTIFIED MAIL: 7016 1370 0000 2596 0672 RETURN RECEIPT REQUESTED January 25, 2019 Donald Chamblee, Director Public Works of Lincoln County 115 W Main St Lincolnton, NC 28092 SUBJECT: NOTICE OF VIOLATION & INTENT TO ISSUE CIVIL PENALTY Tracking No.: NOV-2019-DV-0060 Sanitary Sewer Overflows - September 2018 Collection System Permit No. WQCS00149 E Lincoln County Collection System Lincoln County Dear Mr. Chamblee: A review has been conducted of the self -reported Sanitary Sewer Overflows (SSO's) 5-Day Report/s submitted by Lincoln County. The Division's Mooresville Regional Office concludes that the Lincoln County violated Permit Condition I (2) of Permit No. WQCS00149 by failing to effectively manage, maintain, and operate their collection system so that there is no SSO (Sanitary Sewer Overflow) to the land or surface waters and the SSO constituted making an outlet to waters of the State for purposes of G.S. 143-215.1(a)(1), for which a permit is required by G.S. 143-215.1. The Mooresville Regional Office is providing the Lincoln County an opportunity to provide evidence and justification as to why the Lincoln County should not be assessed a civil penalty for the violation(s) that are summarized below: Total Vol Total Surface Incident Start Duration Vol Water Number Date (Mins) Location Cause (Gals) (Gals) DWR Action 201801450 9/10/2018 42 2460 Hwy 16 N Pump station 3,000 0 Notice of Violation equipment failure w/ Intent to Enforce '�iartNCGroinftHPtRmentufEgihmmantYQuMar'I g17tYpnofW�tM1':4iqutep; MaonaviNFtKion}(Olra I �10 E�fR'C`MntarAirne�,$uke>1o11�M9ofn+.ilMi,NatlbGroinw,�81�¢ io��3-1894 This Notice of Violation / Notice of Intent to Enforce (NOV/NOI) is being issued for the noted violation. Pursuant to G.S. 143-215.6A, a civil penalty of not more than twenty-five thousand dollars ($25,000.00) may be assessed against any person who violates or fails to act in accordance with the terms, conditions, or requirements of any permit issued pursuant to G.S. 143-215.1. This office requests that you respond to this Notice, in writing, within 30 business days of its receipt. In your response, you should address the causes of non-compliance, remedial actions, and all other actions taken to prevent the recurrence of similar situations. The response to this correspondence will be considered in this process. Enforcement decisions will also be based on volume spilled, volume reaching surface waters, duration and gravity, impacts to public health, fish kills or recreational area closures. Other factors considered in determining the amount of the civil penalty are the violator's history of non-compliance, the cost of rectifying the damage, whether the spill was intentional and whether money was saved by non-compliance. If you have any questions, please do not hesitate to contact W. Corey Basinger with the Water Quality Section in the Mooresville Regional Office at 704-663-1699 or via email at corey.basinger@ncdenr.gov. Sincerely, DocuSigned by: A14CC681AF27425... W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Mooresville Regional Office Division of Water Resources, NCDEQ Cc: Mooresville Regional Office - WQS File Central Files, Water Quality Section 6ftlidituinsDp4rlw}enta(Eo�imroeoulquHiy O"rkofWKr0"00p; -' .... ..Aloon;vil.Asjlan}i.Gl�a<I��oEI���'ants�lwnuli�it.�ltil�tAdorssYqftr�loilaGSoYn.281d8 State of North Carolina DWR Department of Environment and Natural Resources Division of Water Resources Divlslon of Water Resources Collection System Sanitary Sewer Overflow Reporting Form Form CS-SSO PART I: This form shall be submitted to the appropriate DWR Regional Office within five business days of the first knowledge of the sanitary sewer overflow (SSO). Permit Number: WQCS00149 (WQCS# if active, otherwise use WQCSD#) Facility: Lincoln County Sewer System Incident #: Owner: Lincoln County Region: Mooresville City: Denver County: Lincoln Source of SSO (check applicable): ® Sanitary Sewer ® Pump Station / Lift Station SPECIFIC location of the SSO (be consistent in description from past reports or documentation - i.e. Pump Station 6, Manhole at Westall & Bragg Street, etc.): Lift Station #12 Manhole #: Latitude (degrees/minute/second): 35 30' 27.4" Longitude (degrees/minute/second): 81 00' 8.9" Incident Started Dt: 09-10-2018 Time: 9:33am Incident End Dt: 9-10-2018 Time: 10:15am (mm-dd-yyyy) (hh:mm) AM/PM (mm-dd-yyyy) (hh:mm) AM/PM Estimated volume of the SSO: 3000 gallons Estimated Duration (round to nearest hour): 1 h0ur(s) Describe how the volume was determined: Visual observation of the amount of flow mulitpied by the time Weather conditions during the SSO event: clear Did the SSO reach surface waters? ❑ Yes ® No ❑ Unknown Volume reaching surface waters: gallons Surface water name: Did the SSO result in a fish kill? ❑ Yes ® No ❑ Unknown If Yes, what is the estimated number of fish killed? SPECIFIC cause(s) of the SSO: ❑Severe Natural Conditions ❑ Grease []Roots ❑Inflow, & Infiltration ®Pump Station Equipment Failure ❑ Power Outage ❑Vandalism ❑ Debris in line ❑Pipe Failure (Break) ❑Other (Please explain in Part ll) 24-hour verbal notification (name of person contacted): Lon Snider ®DWR []Emergency Management Date (mm-dd-yyy): 9-10-2018 Time: (hh:mm AM/PM): 11:20anr Per G.S. 143-215.1 C(b), the owner or operator of any wastewater collection system shall: In the event of a discharge of 1,000 gallons or more of untreated wastewater to the surface waters of the State, issue a press release to all print and electronic news media that provide general coverage in the county where the discharge occurred setting out the details of the discharge. The press release shall be issued within 24 hours after the owner or operator has determined that the discharge has reached surface waters of the State. In the event of a discharge of 15,000 gallons or more of untreated wastewater to the surface waters of the State, publish a notice of the discharge in a newspaper having general circulation in the county in which the discharge occurs and in each county downstream from the point of discharge that is significantly affected by the discharge. The Regional Office shall determine which counties are significantly affected by the discharge and shall approve the form and content of the notice and the newspapers in which the notice is published. WHETHER OF NOT PART 11 IS COMPLETED, A SIGNATURE IS REQUIRED SEE PAGE 13 Form CS-SSO Page 1 In order to submit a claim for justification of an SSO, you must use PartII of form CS-SSO with additional documentation as necessary. DWR staff will review the justification claim and determine if enforcement action is appropriate. VAK1 u: ANSWER THE FOLLOWING QUESTIONS FOR EACH RELATED CAUSE CHECKED IN PART I OF THIS FORM AND INCLUDE THE APPROPRIATE DOCUMENTATION AS REQUIRED OR DESIRED COMPLETE ONLY THOSE SECTONS PERTAINING TO THE CAUSE OF THE SSO AS CHECKED IN PART I (In the check boxes below, NA = Not Applicable and NE = Not Evaluated) A HARDCOPY OF THIS FORM SHOULD BE SUBMITTED TO THE APPROPRIATE DWR REGIONAL OFFICE UNLESS IS HAS BEEN SUBMITTED ELECTRONICALLY THROUGH THE ONLINE REPORTING SYSTEM Form CS-SSO page 2 Pump Station Equipment Failure (Documentation of testing records etc should be provided upon request) What kind of notification/alarm systems are present? Auto-dialer/telemetry (one-way communication) ® Yes Audible ® Yes Visual ® Yes SCADA (two-way communication) ❑ Yes Emergency Contact Signage ® Yes Other ❑ Yes If Yes, explain: Describe the equipment that failed: Pump #2 malfuntioned, several wires throught the control panel burnt up, and the control panel breaker tripped What kind of situations trigger an alarm condition at this station (i.e. pump failure, power failure, high water, etc.)? Were notification/alarm systems operable? ❑ Yes ® No ❑NA ❑ NE In no, explain: When the breaker tripped it disabled the Dialer If a pump failed, when was the last maintenance and/or inspection performed? 9-05-2018 What specifically was checked/maintained? Pump operation, alarm operation, generator operation, cleanliness, and security. If a valve failed, when was it last exercised? Were all pumps set to alternate? ® Yes ❑ No Did any pump show above normal run times prior to and during the SSO event? ❑ Yes ® No Were adequate spare parts on hand to fix the equipment ® Yes ❑ No ❑NA ❑ NE ❑NA ❑ NE ❑NA ❑ NE Was a spare or portable pump immediately available? ® Yes ❑ No ❑NA ❑ NE If a float problem, when were the floats last tested? How? If an auto -dialer or SCADA, when was the system last tested? How? 9.05-2018 an alarm is triggered and staff recieves an alert Comments: Form CS-SSO Page 7 System Visitation ORC ® Yes Backup ❑ Yes Name: Michael Paul Simmons Certification Number: 997855 Date visited: 9-10-2018 Time visited: 10:50am How was the SSO remediated (i./e. Stopped and cleaned up)? Burnt wires were replaced and the breaker was reset, this allowed pump one to operate and the SSO immediately stopped. A pumper truck was used to clean up sewage that was pooled up on the ground. Pump #2 was replaced with a spare pump we keep on hand. The dialer was also replaced. As a representative for the responsible party, I certify that the information contained in this report is true and accurate to the best of my knowledge Person submitting claim: Michael P. Simmons Date: 9-13-2018 Signature: /� �'� .�� Title: Ojoeryl'.-ons S�krinkAAA(-" J Telephone Number: 704-736-8497 Any additional information desired to be submitted should be sent to the appropriate Division Regional Office within five business days of first knowledge of the SSO with reference to the incident number (the incident number is only generated when electronic entry of this form is completed, if used). Form CS-SSO Page 13