Loading...
HomeMy WebLinkAboutNC0049662_Compliance Evaluation Inspection_20190201ROY COOPER '� —• '� r` „a,� rr-6 •, wr MECH;1EL S. F,I=Gr1N r • �� LINDA CULPEPPER � � • Envir�nmeirtal Quvlrry February 1, 2019 MR. SHANNON V. BECKER — PRESIDENT AQUA NORTH CAROLINA, INC. 202 MACKENAN COURT CARY, NORTH CAROLINA 27511 Subject: Compliance Evaluation Inspection NPDES Permit No. NC0049662 Hawthorne Subdivision kVWTP Wake County Dear ivIr. Becker: 1 On December 19, 2018, Cory Larsen with Wake County Department of Environmental Services, on behalf of the Division of Water Resources, performed a compliance evaluation inspection of the subject wastewater treatment system to evaluate compliance with the subject permit to discharge wastewater. Roger Tupps and Rob Boone (ORC) provided their assistance for the inspection which was appreciated. Please refer to the attached inspection report for full results. On the day of the inspection, the plant was operating normally and producing clear effluent through trains 3-4. The plant has been upgraded to better handle surge flows and denitrify to meet more stringent nutrient effluent limitations, and no compliance issues were found during the inspection. If you have any questions regarding this inspection or ever require assistance maintaining compliance with your permit, please contact Cory Larsen at 919-480-9998 / cory.larsenGZwakei-,ov.com or me at (919) 791-4200. Sincerely, Rick Bolich, L.G., Assistant Regional Supervisor Division of Water Resources, Water Quality Regional Operations Section Enclosure: DWR Inspection Report cc: Wake County Department of Environmental Services File RRO File Do,: Mz ^ `it.r'h �ar,tlir:a `:)• p:Ir! >;a'tt! rIf kir'.ir :n r eo ,d f; .�6!, r? ui':V stCr' e: utcn EM� Central Files NPDES Permitting Unit Roger Tupps - Aqua NC, Inc. (202 IvlacKenan Ct. Cary, NC 27511) L'iled States Environtnentai Prwechen Agency Form Approved EPA Wasningtcn 0 : 20a60 OMB No 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A. National Data System Coding (i e , PCS) Transaction Code NPDES yr,mo,day nspect.c- Type Inspector Fac Type .1 IN 1 2 1s 1 3 NCO049662 '11 12 18112r19 LJ 17 i B l 9 t 191 c I 20I uI LJ 21Ill I 6 Inspection Work Days Factl ly Self -Monitoring Evaluation Rating B 1 OA —Reserved 67 70 I_j 71 u 72 L f 73 Lr 174 751 I I I I 1 I 180 Section B Facility Data Name and Location of Facility Inspected %For Industrial Users d'scharging to POT.Aj also ndude ntry Time/Date Permit Effective Date P07VI name and NPDES Permit Number. 11 COAM 1a-1214 la:03.01 Hawthorne Subdivision VWVrP N Hawthcme Way Exit TimelDate Permit Exp ration Date Raleigh NC2760' t230PM 1a'12119 23:01,31 Names) of Onsite Representativeysi;Titles(s:.Phone and Fax Number..s, t , Faality Data P1 Robert P. BonneVORC!! Name, Address of Responsible Of vali7itle.Phone and Fax Number Timothy Glenn Thomas P919.467-8712'9194661583 Contacted No Section C. Areas Evaluated During Inspection (Check only those areas evaluated) Permit 0 Flow Measurement a Operations & Maintenance ■ RecordslReports Self-Moniloring Program M Sludge Handling Disposal M Facility Site Review M Effluent/Receiving Waters Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Names) and Signature(s) of Inspecter(s) AgencylOfficelPhcne and Fax Numbers Date Cor/ Larsen RRO MP919-856-7443. grrw;<I-L --1--- 01/31/2019jjji Signature of Management O A Reviewer AgencylOfficelPhene and Fax Numbers ate EPA Form 3560-1 (Rev 4-94) Previous editions are obsolete, NPOES yr-mWday In c-tion Typm 31 NC0049662 11 12 18/52119 17 18 ICI LJ Section D Summary of Finding/Comments (Attach additional sheets of narrative and checkiists as necessary} WCES inspected the WWTP on 12/18/18 with the assistance of Roger Tupps and Ron Boone' (ORC). Trains 3 and 4 were in operation and producing good quality effluent. Upgrades are mostly complete and equalization is available to prevent surge through the plant which had passed solids in the past. No compliance issues were observed for followup. WCESrCL. Pam# Permit., NCO049662 Owner - Facility. Hatvthome Su@divir1on VNNTP Inspection Dale: 1211912018 Inspection Type: Ccmpliance Evaluatian Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? M ❑ ❑ ❑ Does the facility analyze process control parameters. for ex. NILSS NICRT Settleable ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Plant has been refurbished in the last year and all 4 trains are available. Two of four utilized no 3 and no 4 - largest) Permit Yes No NA NE (If the present permit expires in 6 months or less) Has the permittee submitted anew 0 ❑ ❑ ❑ application? Is the facility as described in the permit? M ❑ ❑ ❑ # Are there any special conditions for the permit? 0 ❑ ❑ ❑ Is access to the plant site restricted to the general public? ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? ❑ ❑ ❑ Comment: Permit was renewed in 2018 W/VTP secured with fencing. Record Keening Yes No NA NE Are records kept and maintained as required by the permit? ❑ ❑ ❑ Is all required information readily available, complete and current? ❑ ❑ ❑ Are all records ma nta'ned for 3 years (lab. reg. required 5 years;? ❑ ❑ ❑ Are analytical results consistent w th data reported on DNIRs? , ❑ ❑ ❑ Is the chain -of -custody complete? ■ ❑ ❑ ❑ Dates times and location of sampl.ng ❑ Name of indiv'dual performing the sampling ❑ Results of analysis and calibration ❑ Dates of analysis ❑ Name of person performing analyses ❑ Transported COCs ❑ Are DN1Rs complete: do they include all permit parameters'? 0 ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DVVQ? 0 ❑ ❑ ❑ (If the facility is = or a 5 N1GD permitted flow; Do they operate 2417 with a certTed operas--r ❑ ❑ a ❑ on each shift? Is the ORC vis.tation log available and current? ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility class fcat on? ❑ ❑ ❑ Pagr-# 3 owner - Facility: Hmvthorne S6bd141SIOn wWr? Permit: NCO049662 Inspection Type Ccmpliance £valuawn Inspection Date: 1211912018 Yes No NA NE Record Keepincl � ❑ ❑ ❑ Is the backup operator certified at one grade tens or greater than the facility dassifcation ■ ❑ ❑ ❑ Is a copy of the current NPDES permit available on site'? ❑ ❑ ■ ❑ Facility has copy of previous year's Annual Report on file for review? Comment: Records were reviewed and looked complete._ ORC I)q, bench sheet ermitlab certification all resent. Re orted concentraions on QMRs matched lab sheets. Yes No NA NE Effluent Ripe Is right of way to the outfall properly maintained? Are the receiving water free of foam other than trace amounts and other debr s? Q if effluent (diffuser pipes are required) are they operating properly? Comment: Effluent pipe dischar es to ri ra aeration ad. No foamin or evidence of solids in creek. Yes No NA NE Flow Measurement • Effluent ❑ ❑ ❑ # is flow meter used for reporting? ❑ ❑ ❑ is flow meter calibrated annually? a ❑ ❑ ❑ Is the now meter operational? ❑ ❑ ❑ (if units are separated) Does the chart recorder matnh the flow mete? 1118 flow meter was calibrated S12b Horizon Comment: 1SCO 4210 ultrasonic measurement En Berincl. Prior da flow was 133,11 a GPO_ Yes No NA NE Aerobic Digester 13 ❑ ❑ ❑ Is the capacity adequate? a ❑ ❑ ❑ Is the mixing adequate? M ❑ ❑ ❑ Is the site free of excessive foaming in the tank 7 M ❑ ❑ ❑ # Is the odor acceptable? IM ❑ ❑ ❑ # Is tankage available for properly waste sludge? train has di ester tank. Both in use were aerated and acce table odor. Comment: Each Yes No NA NE Chemical Feed 13 ❑ ❑ ❑ is containment adequate? 13 ❑ ❑ ❑ Is storage adequate? ❑ ❑ ❑ Are backup pumps available? Page# 4 Permit: NC0049662 Owner - Facility: Hawthorne Subdivision WWTP Inspection Date: 12H9l2018 Inspection Type: Compliance Evaluation Chemical Feed Yes No NA NE Is the site free of excessive leaking? ■ 11 ❑ Comment: Sodium aluminate fed to EQ (pH and TP control Bar Screens Type of bar screen Yes No NA NE a.Manual b.Mechanical Are the bars adequately screening debris? S Is the screen free of excessive debris? Is disposal of screening in compliance? Is the unit in good condition? El El El Comment: Flow enters a mechanical static screen screw lift to remove solids screened to a Waste Industries dum ster. Equalization Basins Yes No NA NE Is the basin aerated? C-1 ❑ 11 Is the basin free of bypass lines or structures to the natural environment? Is the basin free of excessive grease? ❑ Are all pumps present? ❑ Are all pumps operable? Are float controls operable? Are audible and visual alarms operable? ❑ # Is basin sizelvolume adequate? Comment: EQ basin has been refurbished with new blowers and control. Two lift stations provide influent. Pump 1 and 2. hi h level alarm. telemet tested and worked -normally. Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? ff Is the site free of excessive buildup of solids in center well of circular clarifier? 0 El 0 El Are weirs level? i E3 ❑ El Is the site free of weir blockage? 0 ❑ ❑ Is the site free of evidence of short-circuiting? , El ❑ ❑ Is scum removal adequate? V El ❑ ❑ Is the site free of excessive floating sludge? 0 Page# 5 owner - Facility• Hawthorne 5ubdivis on 'JIMM Permit: NCO049662 Inspection Type Compliance cvoluacan Inspection DaW 121191201 B Yes No NA NE SecondarY Clarifier ❑ ❑ 0 ❑ Is the drive unit operational? Is the return rate acceptable (low turbulence)? M El 0 El Is the overflow clear of excessive solids/pin floc , ❑ ❑ ❑ (Approximately 1/4 of the sidwall depth) Is the sludge blanket Vevey acceptable? (App Y Comment: Clarifier 3 - aine needles affect skimmer efficient _ Some o u slud e. column but not out of limits. Clarifier 4 - algae in weir. some nine solids noted in water if blanket depth exceeds Sludge blanket sensors being installed and will noti o erator set oint e. . 5 ft. Effluent over weir was clear. Post aeration was workin well. Effluent TSS meter no longer utlized. Yes No NA NE Aeration Basins Ext. Air M--de of operation Diffused Type of aeration system Is the basin free of dead spots? ❑ ❑ ❑ Are surface aerators and mixers operationai7 ❑ Are the diffusers operational? Is the foam the proper color for the treatment proceas? 0 ❑ ❑ ❑ Does the foam cover less than 25% of the basin's s irfa--e Is the DO level acceptable? 11 El Is the DO level acceptable?(1.0 to 3.0 m911) Comment. Aeration basins were med. brown color with little foam. Anoxic zone at head with rec cle rate to denitrify. DO no. 3 = 1.32 m /L DO no. 4 = 1.49 m /L. Kaeser blower motors have variable fre-luency drives to provide consistent DO concentraion in basin. Lange trains 3-4 redone with roundwater drains to revent floatation. Yes No NA NE Disinfection - UV Are extra UV bulbs available on site? M ❑ ❑ ❑ Are UV bulbs clean? i ❑ ❑ ❑ Is UV intensity adequate? 0 ❑ ❑ Cl Is transmittance at or above designed level? M ❑ ❑ ❑ Is there a backup system on site? e ❑ ❑ ❑ Is effluent clear and free of solids? Page# 6 f Permit: N00049662 Owner • Facility: Hawthorne Subdivssion toWVTP Inspection Date: 12: 19:201 B Inspection Type: Compliance Evaluation Disinfection - UV Yes No NA NE Comment: UV consists of 4 banks with 4 lamRs each. All were lit. Bulbs replaced annually and as needed Standby Power Is automatically activated standby power available'? Is the generator tested by interrupting primary power source? Is the generator tested under load? Was generator tested & operational during the inspection? Do the generator(s) have adequate capacity to operate the entire wastewater site? Is there an emergency agreement w!th a fuel vendor for extended run on back-up power? Is the generator fuel level monitored? Comment. Generator was transferred electrical load and cut on properly. Effluent Sampling Is composite sampling Flow proportional? Is sample collected below all treatment units? Is proper volume collected? Is the tubing clean? # Is proper temperature set for sample storage (kept at less than rr equal to 6 0 degrees Celsius)? Is the facility sampling performed as required by the permit (frequency. sampling type representative)? Comment: ISCO oom osite sampler 5800 operated and was cold. Upstream / Downstream Sampling Is the facility sampling performed as required by the permit tfrequency sampr�ng type and sampling location)? Comment: US/DS saMpli-nq Performed properlV. Yes No NA NE ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ 19 ❑ ❑ ❑ ® ❑ ❑ ❑ ®❑ ❑ ❑ a❑ ❑❑ Yes No NA NE ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ OWN Yes No NA NE ■ ❑ ❑ ❑ Pager 7 I t T