Loading...
HomeMy WebLinkAboutWQ0018007_Staff Report_20190207 State of North Carolina Division of Water Resources Water Quality Regional Operations Section Environmental Staff Report Quality To: ❑NPDES Unit®Non-Dischar eg Unit Application No.: W00018007 Attn: Troy Doby,RCO Facility: Town of Broadway RLAP Class B Wastewater Residuals From: Thomas McKinney,RRO Renewal Application County: Lee Note: This form has been adapted from the non-discharge facility staff report to document the review of both non- discharge and NPDES permit applications and/or renewals. Please complete all sections as they are applicable. I. GENERAL AND SITE VISIT INFORMATION 1. Was a site visit conducted?®Yes or❑No a. Date of site visit: 02/04/2019 b. Site visit conducted by: T.McKinney c. Inspection report attached? ❑ Yes or®No d. Contacted: W.Craig Buchanan(919)258-9922 e. Hwy 1 to Sanford, from Sanford bypass, exit Hwy 42 east to Broadway, north on Buckhorn to Bradley Rd. 2. Discharge Point(s):NA non-discharge Latitude: Longitude: Latitude: Longitude: 3. Receiving stream or affected surface waters:NA Classification:NA River Basin and Sub-basin No.NA Describe receiving stream features and pertinent downstream uses:NA 111. EXISTING FACILITIES: RENEWAL APPLICATION Are there appropriately certified Operators in Charge(ORCs)for the facility?❑ Yes ❑No ®N/A ORC: W. Craig Buchanan for RLAP Class B: Certificate#: LA 17572 Backup: George Watson for RLAP Class B: Certificate#: LA 23353 1. Are the design, maintenance and operation of the treatment facilities adequate for the type of waste and disposal system? ®Yes or❑No FORM:WQROSSR04-14 Page I of 2. Explain anything observed during the site visit that needs to be addressed by the permit, or that may be important for the permit writer to know. No changes needed. 3. Are the site conditions (e.g., soils,topography, depth to water table,etc.)maintained appropriately and adequately assimilating the waste? ®Yes or❑No If no,please explain: 4. Has the site changed in any way that may affect the permit(e.g., drainage added,new wells inside the compliance boundary,new development, etc.)? ❑ Yes or®No If yes,please explain: 5. Is the residuals management plan adequate? ®Yes or❑No If no,please explain: 6. Are the existing application rates(e.g., hydraulic,nutrient)still acceptable? ®Yes or❑No If no,please explain: 7. Is the existing groundwater monitoring program adequate? ❑Yes ❑No ®N/A If no, explain and recommend any changes to the groundwater monitoring program: 8. Are there any setback conflicts for existing treatment, storage and disposal sites? ❑Yes or®No If yes, attach a map showing conflict areas. 9. Is the description of the facilities as written in the existing permit correct? ®.Yes or❑No If no,please explain: 10. Monitoring wells properly constructed and located? ❑Yes ❑No ®N/A If no;please explain: FORM:WQROSSR 04-14 Page 2 of 4 M.REGIONAL OFFICE RECOMMENDATIONS 1. Do you foresee any problems with issuance/renewal of this permit? ❑ Yes or®No No violations or problems indicated in BIMS database. 2. List any items that you would like the NPDES Unit or Non-Discharge Unit Central Office to obtain through an additional information request: Item Reason 3. List specific permit conditions recommended to be removed from the permit when issued: Condition Reason 4. List specific special conditions or compliance schedules recommended to be included in the permit when issued: Condition Reason S. Recommendation: ❑ Hold, pending receipt and review of additional information by regional office ❑Hold,pending review of draft permit by regional office ❑ Issue upon receipt of needed additional information ®Issue ❑Deny(Please state reasons: 6. Signature of report preparer: T�"- Signature of regional supervisor: Date: FORM: WQROSSR 04-14 Page 3 of 4 IV.ADDITIONAL REGIONAL STAFF REVIEW HEMS 1. There have been no changes to the five land application fields(01, 03A, 03B, 04,and 05) specified in Attachment B of the current permit. 2. The facility maintains the required records of land application events for the Class B residuals as required by permit condition IV.7. 3. As specified in permit condition IV.8.,the facility has been submitting annual reports with proper analysis for metals&nutrients,non-hazardous determination, and pathogen&vector attraction reduction.The non-hazardous determination is now required only once per permit cycle. FORM:WQROSSR04-14 Page 4of4