Loading...
HomeMy WebLinkAboutNC0076066_Compliance Evaluation Inspection_20190103 a IV ROY COOPER NORTH CAROLINA Governor - Environmental Quality MICHAEL S.REGAN secretary LINDA CULPEPPER Interim Director --_January 3-2019- -------- --- Mr. Tommy Spicer Wilkes County Schools 613 Cherry St. - North Wilkesboro, NC 28659 Subject: Compliance Evaluation Inspection North Wilkes High School WWTP NPDES Permit# NC0076066 Wilkes County Dear Spicer: A Compliance Evaluation Inspection was performed by Division of Water Resources, Winston Salem Regional Office, staff person Justin Henderson, on December 19, 2018. Mr. Tommy Spicer, Operator in Responsible Charge (ORC), was present for this inspection. This type of inspection consists of two basic parts: an in-office review of the facility files and self-monitoring data and an on-site inspection of the facility While this inspection mostly reflects compliance with Permit No. NC0076066, the following concerns requires your attention and action: 1) Significant holes were observed in two laterals in separate sand filters, resulting in uneven distribution and ponding of effluent upon system dosing. Several remaining laterals appeared to be unlevel containing high and low spots, which also was contributing to uneven distribution and ponding of effluent. Observation of system dosing should immediately be incorporated in the routine maintenance procedures and performed at a frequency that will allow prevention of unevenly distribution and/or ponding of effluent, as well as timely repair of damaged laterals within the sand filters. 2) There were no de-chlorination tablets present in the de-chlorination equipment at the time of this inspection. Failure to properly maintain the dechlorination equipment and to adequately replace tablets may result in effluent parameter violations. It is recommended that weekly monitoring of dechlorination equipment be included in routine maintenance procedures with monitoring frequencies increasing before and after high rainfall events or high-water usage events. 3) Rust and corrosion was observed inside the effluent pump station control panel, indicating that the pump station control panel no longer appeared to be weather-proof. While, the control panel appeared to be operational at the time of this inspection, it is strongly recommended that this panel be repaired or replaced with a weather-proof panel box to ensure the integrity and reliably of the internal components, and to prevent potential interruption of operations. fab `d( T I e"A.<t'hF ae 33nry1»rtmn/of EnNrmnmenti311llaQ North Carolina Department of Environmental Quality I Division of Water Resources Winston-Salem Regional Office 1450 Hanes Mill Road,Suite 300 Winston-Salem,North Carolina 27103 336 776 980 0 4) Post-calibration records for portable meters were unavailable for review at time of this inspection. Post-calibration of portable meters, utilized for effluent parameter analyses, must be performed and documented, and records made available upon request. All calibration records must be maintained for a period of at least 3 years per Permit Condition Part II. Section D. (6.). Please refer to the enclosed compliance inspection report form for additional observations and comments. If you have any questions regarding this correspondence, please contact Justin Henderson or me at (336) 776-9800. Sin erely 41, S -rri V. Knight, P.E. Regional Supervisor Water Quality Regional Operations Divisions of Water Resources enc: BIMS Inspection Report cc: WSRO Central Files c NPDES Unit • • D_E NA7.1tF rfiiCl't.d Departmmtnl£m1tmITBnta1 mauty North Carolina Department of Environmental Quality I Division of Water Resources Winston-Salem Regional Office 1450 Hanes Mill Road,Suite 300 t Winston-Salem.North Carolina 27103 336.776.9800 ` 1 United States Environmental Protection Agency Form Approved EPA Washington,D C 20460 OMB No 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A:National Data System Coding(i.e,PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 2 IS I, 3 I NC0076066 111 121 18/12/19 117 181,.E 19I s I 20I 21I1II I I I I I III ' I I I 1 I I I I I I I I I I I I I I I I I I I I I I I I I r6 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA Reserved 67I I 70 LJI I 711 I 72 731 I 174 751 I I I I I I I80 Section B:Facility Data IL—JJ Name and Location of Facility Inspected(For Industrial Users discharging to POTW,also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 09 OOAM 18/12/19 13/12/01 North Wilkes High School WWTP Exit Time/Date Permit Expiration Date 2986 Traphill Rd 11 45AM 16/12/19 18/09/30 Hays NC 28635 Name(s)of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data /// Thomas J Spicer/ORC/336-651-4010/ Name,Address of Responsible OfficiaVTitle/Phone and Fax Number Contacted Bergie Speaks,613 Cherry St North Wilkesboro NC No 28659//336-667-2021/3366679688 Section C Areas Evaluated During Inspection(Check only those areas evaluated) El Permit • Flow Measurement • Operations&Maintenance II Records/Reports • Self-Monitoring Program 111 Sludge Handling Disposal II Facility Site Review Effluent/Receiving Waters Il Laboratory Section D Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s)and Signature(s)of Inspector(s) Agency/Office/Phone and Fax Numbers Date Justin L Henderson WSRO WQ//336-776-9701/ I / rre. I jeAA Signa ure of M`j agement iii A eviewer Agency/Office/Phone and Fax Numbers Date wy.f 1/17/ EPA Form 3560-3(Rev 9-94)Previous editions are obsolete Page# 1 ,I NPDES yr/mo/day Inspection Type (Cont.) 1 31 NCoo76o66 111 121 10/12/19 117 18 i i Section D Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) The following items of concern requiring your attention and action were identified during this inspection 1) Significant holes were observed in two laterals in separate sand filters, resulting in uneven distribution and ponding of effluent upon system dosing. Several remaining laterals appeared to be unlevel containing high and low spots,which also was contributing to uneven distribution and ponding of effluent. Observation of system dosing should immediately be incorporated in the routine maintenance procedures and performed at a frequency that will allow prevention of unevenly distribution and/or ponding of effluent, as well as timely repair of damaged laterals within the sand filters. 2) There were no de-chlorination tablets present in the de-chlorination equipment at the time of this inspection. Failure to properly maintain the dechlonnation equipment and to adequately replace tablets may result in effluent parameter violations. It is recommended that weekly monitoring of dechlorination equipment be included in routine maintenance procedures with monitoring frequencies increasing before and after high rainfall events or high-water usage events 3) Rust and corrosion was observed inside the effluent pump station control panel, indicating that the pump station control panel no longer appeared to be weather-proof. While, the control panel appeared to be operational at the time of this inspection, it is strongly recommended that this panel be repaired or replaced with a weather-proof panel box to ensure the integrity and reliably of the internal components, and to prevent potential interruption of operations 4) Post-calibration records for portable meters were unavailable for review at time of this inspection Post-calibration of portable meters, utilized for effluent parameter analyses, must be performed and documented, and records made available upon request.All calibration records must be maintained for a period of at least 3 years per Permit Condition Part II.Section D. (6.). Page# 2 r a Permit. NC0076066 Owner-Facility: North Wilkes High School WWTP Inspection Date: 12/19/2018 Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping'? 1. 0 0 ❑ Does the facility analyze process control parameters, for ex MLSS, MCRT, Settleable ❑ 0 • ❑ Solids, pH, DO, Sludge Judge, and other that are applicable'? . Comment Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ • ❑ application? Is the facility as described in the permit'? 0 0 0 #Are there any special conditions for the permit'? 00110 Is access to the plant site restricted to the general public'? • ❑ 0 ❑ Is the inspector granted access to all areas for inspection'? • 0 ❑ 0 Comment De-chlorination Yes No NA NE Type of system'? Tablet Is the feed ratio proportional to chlorine amount(1 to 1)? ❑ • ❑ ❑ Is storage appropriate for cylinders'? • 0 0 ❑ #Is de-chlorination substance stored away from chlorine containers'? III 0 ❑ ❑ Are the tablets the proper size and type? • ❑ ❑ 0 Comment The tablet dechlorinator was empty at time of this inspection. Montiorinq frequencies should be increased before and after high rainfall events and/or high water usage events to ensure an adequate supply of tablets are maintained Are tablet de-chlorinators operational'? • 0 ❑ ❑ Number of tubes in use'? 0 Comment: The tubes were empy and in need of refilling at time of this inspection. Septic Tank Yes No NA NE (If pumps are used) Is an audible and visual alarm operational'? ❑ ❑ II ❑ Is septic tank pumped on a schedule'? • ❑ El Are pumps or syphons operating properly'? III ❑ ❑ ❑ Are high and low water alarms operating properly'? ❑ ❑ I ❑ Comment Page# 3 Permit: NC0076066 Owner-Facility: North Wilkes High School wwTP Inspection Date: 12/19/2018 Inspection Type: Compliance Evaluation Sand Filters (Low rate) Yes No NA NE (If pumps are used)Is an audible and visible alarm Present and operational'? 0 ❑ E ❑ Is the distribution box level and watertight'? • ❑ ❑ ❑ Is sand filter free of ponding? ❑ • 0 ❑ , • Is the sand filter effluent re-circulated at a valid ratio'? ❑ 0 • ❑ #Is the sand filter surface free of algae or excessive vegetation'? • ❑ 0 ❑ #Is the sand filter effluent re-circulated at a valid ratio'?(Approximately 3 to 1) ❑ ❑ • ❑ Comment Significant pipe failures of two laterals was observed in separate sand filters at time of inspection.These failure were resulting in uneven effluent distribution and ponding within the sand filters. Laterals shall be repaired immediately. Routine maintenace procedures shall included observation of system dosing at frequencies sufficient to prevent uneven distribution, ponding, and allow for timely repair of damaged laterals. Disinfection-Tablet Yes No NA NE Are tablet chlorinators operational? • 0 ❑ ❑ Are the tablets the proper size and type'? • ❑ ❑ ❑ Number of tubes in use'? 2 Is the level of chlorine residual acceptable'? • ❑ ❑ 0 Is the contact chamber free of growth, or sludge buildup'? M ❑ ❑ ❑ Is there chlorine residual prior to de-chlorination'? • 0 ❑ ❑ Comment' Effluent Sampling Yes No NA NE Is composite sampling flow proportional'? ❑ 0 E ❑ Is sample collected below all treatment units? • ❑ 0 ❑ Is proper volume collected'? • ❑ 0 ❑' Is the tubing clean'? 0 0 II ❑ #Is proper temperature set for sample storage(kept at less than or equal to 6.0 degrees ❑ 0 • ❑ Celsius)? Is the facility sampling performed as required by the permit(frequency,sampling type M 0 ❑ ❑ representative)? Comment. Page# 4