Loading...
HomeMy WebLinkAboutDEQ-CFW_00088293DuPont Automotive - Fayetteville Works Fayetteville, North Carolina El-17026 TABLE 2-2 TEST RESULTS SUMMARY DMF SCRUBBER MAY 1999 INLET OUTLET Run No. Flow Rate (DSCFM) DMF (ppmvd) Emission Rate (lb/hr) Flow Rate (DSCFM) DMF (ppmvd) Emission Rate (lb/hr) Removal Efficiency N 1 12,222 115.2 16.0 12,390 1.02 0.144 99.1 2 11,707 96.8 12.9 11,880 3.24 0.439 96.6 3 12,016 96.7 13.2 12,195 3.53 0.490 96.3 Average 1 11,982 102.9 14.0 12,155 2.60 0.358 97.3 TABLE 2-3 TEST RESULTS SUMMARY PROCESS AND SCRUBBER OPERATING CONDITIONS MAY 1999 Water Flow Air Flow Process Process Run No. to Nozzles to Nozzles Bandwidth* Speed* (gpm) (scfm) (inches) (ft/min) Nozzle 1 - 6.0 Nozzle 1 - 62 1 Nozzle 2 - 6.0 Nozzle 2 - 62 8.50 170 Nozzle 3 - 6.0 Nozzle 3 - 62 Nozzle 1 - 6.0 Nozzle 1 - 63 2 Nozzle 2 - 6.0 Nozzle 2 - 62 7.25 170 Nozzle 3 - 6.0 Nozzle 3 - 63 Nozzle 1 - 6.0 Nozzle 1 - 65 3 Nozzle 2 - 6.0 Nozzle 2 - 64 7.25 170 Nozzle 3 - 6.0 Nozzle 3 - 65 Average 1 6.0 63 NA NA The process bandwidth and speed values are representative normal operating conditions as required by the General Provisions for MACT standard performance tests per §63.7(e). 2-2 DEQ-CFW 00088293