Form D: Process Information (Page 1 of 2) Facility ID# 0900009
• North Carolina Department of Environment and Natural Resources
Division of Air Quality
Calendar 2000 Air Pollutant Point Source Emissions Inventory
1. Source ID No. (same as in permit) BS-1 (BS-A in Title V)
2. Process Description: Butyraldehyde Storage Tank
4, Maximum Process Rate: 4. CY 2000 Process Throughput:
(Ex: gal/hr, mmcf/hr) Confidential (Ex: lb, gal) Confidential
include units
5. Normal Operating Schedule:
Hours per Days per
Day Week
6. Typical Start & End Times For Process:
Start
Weeks
per Year
Continuous
include units
Hours per
Year Confidential
End:
7. Percentage Annual Throughput:
Dec -Feb 25 Mar -May 25 June -Aug 25 Sept -Nov 25
100%
8. Capture Efficiency (% of Emissions from this Process Vented Through Control Device):
9. Control Device Descriptions Primary Brine Cooled Condenser BCD-1 (Title V BCD -A)
•
Secondary: Closed -loop Loading Procedure
10. Combined (Net) Control Device Efficiency (%): PM
(Control efficiency is pollutant specific)
PM-10
PM-2.5
SO2
NOx
VOC 93%
11. ANNUAL FUEL USAGE For This Process Coal, oil, wood, natural as, etc. -Use additional sheets as needed.
Type of Fuel Used in This Process/Source
Amount (gal, tons, mmcf/year)
% Sulfur
% Ash
f you do not provide annual throuchout vour inventory will be deemed incomplete and returned to you
review instructions or get a new copy, go to web page: httn://daa.state.nc.us/Offices/Planning/Attainment/est.html or
Information on Form D cannot be held confidential.
DEQ-CFW 00088150
Form D: Process Information (Page 2 of 2)
CY 2000 Facility ID# 0900009 Source ID# BS-1
Is
E
Actual Emissions Per Pollutant Listed for Source/Process Identified Above:
Attach calculations and documentation of emission factors or other estimation methods used.
"Per Ton" Pollutant:
PM
PM-10
PM-2.5
S02
NOX
VOC
CO
Actual Emissions: Tons/year
1.17
***All Other HAPs/TAPs Per Instructions (use additional sheets if necessary)***
Pollutant
CAS #
Emitted
lbs./ r.
Comments
Chlorine
7782-50-5
Fluorine
7782-41-4
Hydrazine
302-01-2
Hydrogen Chloride (As weight of HCl in solutions)
7647-01-0
Hydrogen Fluoride (As weight of HF in solutions)
7664-39-3
Hydrogen Sulfide
7783-06-4
Lead (As metal or compounds -mass of total)
LEADCPDS
Methyl Chloroform (Not a VOC, by rule)
71-55-6
Methylene Chloride (Not a VOC, by rule)
75-09-2
Ozone (Not expected as a facility emission)
10028-15-6
Perchloroethylene (Not a VOC, by rule)
127-18-4
Phosphine
7803-51-2
List all other HAP/TAPs below IN ALPHABETICAL
ORDER, Per Instructions. Use more sheets, as needed
Information on Form D cannot be held confidential.
DEQ-CFW 00088151
•
•
11
2000 AIR EMISSIONS INVENTORY
BUTYRALDEHYDE STORAGE TANK
(BS-1)
EMISSIONS SUMMARY
PROCESS EMISSIONS:
VOC EMISSIONS
VOC
EMISSIONS
(lb/year)
P
BA Condenser
751
0.38
VOC
VOC
VOC
EMISSIONS
EMISSIONS
EMISSIONS
worst case
with 67%
with 67%
FUGITIVE EMISSIONS:
scenario based
reduction for
reduction for
on AP-42
"Good" control
"Good" control
(lb/year)
(lb/year)
(TPY)
Unloading System
2,750
908
0.45
Recirculation System
126
42
0.02
BA Storage Tank
1917
633
0.32
TOTAL EMISSIONS:
2,334
1.17
DEQ-CFW 00088152
•
2000 AIR EMISSIONS INVENTORY
BUTYRALDEHYDE STORAGE TANK
(BS-1)
EMISSIONS DETERMINATION
Butyraldehyde (BA) emissions from Storage Tank Condenser (BCD-1):
BA (breathing losses) to condenser = 2,482 lb/yr
BA Vapor Pressure at 71.37 °F = 1.844 psi
BA Vapor Pressure at 32 °F = 0.558 psi
0 lb (O.558psi) lb
BA emissions from condenser = 2,482 n X 1.844 psi = 751-
(See information from Title V - Form D6 on following pages)
Butyraldehyde (BA) fugitive emissions from BA Storage Tank:
(See information on following pages)
DEQ-CFW 00088153
BA Fugitive Emissions
Page 1 of 2
20
00 BUTYRALDEHYDE
FUGITIVE EMISSIONS CALCULATIONS
i. FIXED LOSSES
A. Unloading System
Leak rate = (pump losses + liquid valve losses + gas valve losses + flange losses) x
(weight fraction BA) x (total hours)
= [(1)(0.109) + (9)(0.016) + (1)(0.012)+ (27)(0.0018)] (1.0) (8760 hrs.)
= [0.109 + 0.144 + 0.012 + 0.0491] (1.0) (8760)
= (0.314 lbs./hr) (8760 hrs/yr.)
= 2,750lbs./yr.
B. Vapor Return System
Area average Temp. = 75°F
BA Vapor Pressure = 110 mmHg (from Hercules vapor press. curve)
BA mole fraction in vapor
vapor pressure of BA
total pressure
vapor pressure of BA
gauge press. + atms. pressure
G 10 mmHg) 0 atm/760 mmHg)
(4 inch H2O + 406.8 inch H20) (1 atm/406.8 inch H20)
= 0.143 mole BA / mole of gas
Leak rate = [gas valve losses + flange losses] (wt. fraction BA) (tot. operating hrs.)
[ (2)(0.015) + (5)(0.0018) ] (0.143 mol BA) 721b BA) mol as) (8760 hr)
( mol BA ) (28 lb gas) ( yr. )
= (0.030 + 0.0090) (0.143) (2.57) (8760)
0 = 125.61b/yr.
DEQ-CFW 00088154
BA Fugitive Emissions
Page 2 of 2
C. BA Storage Tank
1. Liquid Flanges/Valves
Leak rate = (liq. valve losses + flange losses) (weight fraction BA) (tot. oper. hrs.)
= [(2)(0.016) + (8)(0.0018)] (1.0) (8760)]
= [0.032 + 0.014] (1) (8760)
= 406lbs./yr.
2. Vapor Flanges/Conservation Vents
Leak Rate = (C/V losses + vapor flange losses) (weight fraction BA) (Tot. oper. hrs.)
= [(2)(0.224) + (12)(0.0018)] (0.143) (2.57) (8760)
= [0.448 + 0.0216] (0.143) (2.57) (8760)
= 1,511lb/yr.
3. Total Leak Rate = 406 + 1,511 = 1,9171b/yr.
E
1]
DEQ-CFW 00088155