HomeMy WebLinkAboutDEQ-CFW_00087316Ol • • HFPO Manufacturing Process Air Emissions Inventory Point Source Emission Determination Page 2 of 7 After -control emissions utilizing the 99.6% control efficient Waste Gas Scrubber (WGS): VOC Emissions Waste Gas Scrubber HF Equivalent Emissions 146,190 kg COF2 x (100%-99.6%) 585 kg COF2 = 585 kg COF2 x 0.606 kg HF/kg COF2 = 354 kg HF = 585 kg VOC 1289 Ib. VOC 781 Ib. HF DEQ-CFW 00087316 HFPO Manufacturing Process Air Emissions Inventory Point Source Emission Determination Page 7 of 7 F. Perfluoromethylcyclopropane (PMCP) CAS No. 379-16-8 Oxygen (02) CAS No. 7782-44-7 Fluoroform (CF31-1) CAS No. 75-46-7 Carbon Dioxide (CO2) CAS No.124-38-9 PMCP, 02, CF31-1, and CO2 are not VOCs nor do they have potential to make HF. Since they are not reportable emissions, the calculations are not shown here. G. Point Source Summary Naflon Compound Name Before Control VOC Generated After Control Stack Emissions kglyrVOC lb/yrVOC IblyrVOC VOC ton/yr Ib/yr HF A. COF2 146,190 322,290 1,289 1 781 B. PAF 141,448 311,836 1,247 1 215 C. Acid Fluoride Solvent TFF 38,314 84,466 338 0 204.8 Acid Fluoride Solvent TAF 38,314 84,466 338 0 D. HFP 12,747 28,103 28,103 14 E. HFPO 12,819 28,261 28,261 14 Total 389,832 1 859,423 1 59,576 1 30 11,201 DEQ-CFW 00087317