Loading...
HomeMy WebLinkAboutDEQ-CFW_00086753• AIR EMISSIONS INVENTORY SUPPORTING DOCUMENTATION Emission Source ID No.: INSIG-137 Emission Source Description: Butacite® Plasticizer Storage Tank Process Description: This tank is used to store triethylene glycol bis (2-ethylhexanoate) or 3GO. Emissions from this tank would be exclusively from the diurnal temperature change. Because the delivery railcar is closed -loop vented with the tank, the displaced headspace associated with the unloading of the railcar are vented back to the railcar, thereby resulting in no emissions to the atmosphere. The tank vents to the atmosphere through a conservation vent, so there are normally no emissions from the tank unless the tank is heating up from the sun. Basis and Assumptions: - Venting to atmosphere occurs only from daytime heating. - Tank volume = 60,000 gallons or 8021 ft3 - 3GO vapor pressure = <0.0075 mm Hg @ 20°C (see Note 1) 5 min Hg @ 219°C (see Note 2) Molar volume of an Ideal Gas @ 0°C and 1 atm = 359 ft3/(lb-mole) - Molecular Weight of 3GO = 403 (403 lb 3GO / lb -mole 3GO) Assume one complete tank volume turnover per day for point source emissions. Assume DuPont Good Emission Factor on Equipment Leaks for fugitive emissions (See Appendix A). Flange emissions were used for all equipment except valves and pumps. Note l : Vapor pressure reference from Celenese EC Safety Data Sheet 2001/58/EG revised on February 16, 2007. Note 2: Vapor pressure reference from March 6, 1991, Federal Register Volume 56, Number 44, Page 9571 DEQ-CFW 00086753 Triethylene glycol bis (2-ethylhexanoate) CAS No. 94-28-0 3G0 Point Source Emissions Determination: Assume a diurnal temperature change from a nighttime low of 50°F (10°C or 283°K) to a daytime high of 113°F (45°C or 318°K). Assume the entire tank volume (8021 ft) is nitrogen saturated with 3GO. Assume the ideal gas law applies: Pressure x Volume = lb -moles x Gas Constant x Temperature At a temperature of 10°C (510°R): ( 1 atm) x (8021 ft) = (n lb -moles) x ( 0.73 atm ft3 °R-1 lb-mole-1 x (510°R) n lb -moles = 21.55 lb -moles of gas inside the tank At a temperature of 45°C (573°R): ( 1 atm ) x (8021 ft) = ( n lb -moles) x ( 0.73 atm ft3 °R-1 lb -mole 1) x (5730R) n lb -moles = 19.18 lb -moles of gas inside the tank Therefore, if the tank heats from 10°C to 45°C, then 2.37 lb -mole (21.55 minus 19.18) of gas per day is lost through the conservation vent. Vapor pressure of 3GO = <0.0075 mm Hg at 20°C Mole fraction 3GO in vapor (using Dalton's law): Mole fraction 3GO = Vapor pressure 3GO = 0.0075 mm H = 0.0000099 mole 3GO Total pressure in tank 760 mm Hg mole gas in tank Pounds of 3GO emissions from tank from diurnal temperature change: 2.37 lb -mole x 0.0000099 lb -mole 3GO x 403 lb 3GO = 0.0095 lb 3GO day lb -mole gas in tank lb -mole 3GO day Total 3GO emissions per year from the diurnal temperature change: 0.0095 lb 3GO x 365 days x 1 ton = 0.002 ton 3GO day year 2000 lbs year • DEQ-CFW 00086754 Fugitive Emissions Determination: Equipment Component Number of Components Good Factor (Ib/hr/com onent) Emissions (lb/hr) Emissions (ton/ r Pump Seal 1 0.0075 0.0075 0.033 Heavy Liquid Valve 20 0.00352 0.0704 0.308 Open-ended Line 1 0.0215 0.0215 0.094 Flange/Connection 9 0.00031 0.00279 0.012 Total 0.447 Good factor (lb/hr/component) x Number of Components = Emissions (lb/hr) Emissions (lb/hr) x 1 ton / 2000 lbs x 24 hr/day x 365 days/year = Emissions (ton/yr) Total fugitive 3GO emissions per year = 0.447 ton 3GO / year Emissions Summary: Point Source Emissions + Fugitive Emissions = Total Emissions 0.002 ton 3GO / year + 0.447 ton 3GO / year • 0 = 0.45 ton 3GO / year 0.45 ton VOC / year DEQ-CFW 00086755 APPENDIX A: FUGITIVE EMISSION LEAK RATES FOR PROCESS EQUIPMENT Fugitive emission studies have been done on a number of DuPont facilities and the is measurements were considerable lower than emission factors recommended by the EPA for SOCMI chemical processes. These screening and bagging data have been used to establish "typical" emission factors from DuPont facilities. The data separated into three categories of emission levels for "as found" emissions form plants who were not involved in LDAR programs. As a result of this effort, three sets of DuPont factors were developed: "superior", "excellent", and "good." The superior factors are typical of processes that contain extremely hazardous materials, i.e. phosgene (COC12), chlorine (C12), and hydrogen fluoride (HF). A set of example questions to help guide DuPont sites as to when to use the different categories was also developed and is discussed in the next section. The three categories represent the range found at DuPont facilities, but still are much lower than EPA SOCMI factors. All three sets of factors are listed below. EMMISION FACTORS (lb/hr/component) COMPONENT SERVICE SUPERIOR EXCELLENT GOOD EPA SOCMI Pump Seals Light Liquid xxxxx 0.00115 0.0075 0.109 Pump Seals Heavy Liquid xxxxx 0.00115 0.0075 0.047 Valves Gas xxxxx 0.00039 0.00549 0.012 Valves Light Liquid xxxxx 0.00036 0.00352 0.016 Valves Heavy Liquid xxxxx 0.00036 0.00352 0.00051 Pressure Relief Seals Gas/Vapor xxxxx 0.00012 0.00013 .0.23 Open Ended Lines All xxxxx 0.001 0.0215 0.0037 Flanges All xxxxx 0.00018 0.00031 0.0018 Sampling Connections All xxxxx 0.00018 0.00031 0.033 Compressor Seals Gas/Vapor N/A N/A NIA 0.50 Overall Emission Factor 1/10,000 1/20 1/3 1/1 Heavy liquid means a liquid with a true vapor pressure of less than 0.3 kPa (0.04 psia) at a temperature of 294.3 °K (70 °F); or which has 0.1 Reid Vapor Pressure; or which when distilled requires a temperature of 421.95 °K (300 °F); or greater to recover 10 percent of the liquid as determined by ASTM method D86-82. Light liquid means a liquid that is not a heavy liquid. • DEQ-CFW 00086756 Which factors should I use? The factors suggested above represent DuPont "experience" and more accurately reflect 40 OVERALL fugitive emissions from DuPont facilities, i.e. the DuPont culture. The comparisons were made with a limited database and the factors suggested here reflect a comparison of overall or aggregate emission levels to those predicted by EPA SOCMI factors. It should be pointed out that individual DuPont factors did vary from specific source service factors suggested by EPA, i.e. light or heavy liquid service. For the "Superior" category, the individual factors are extremely small numbers, and therefore, it is suggested to calculate the emission estimate with EPA SOCMI factors, and then divide the total by the 10,000 factor. Since there is considerable variability in ANY individual component leak rate due to type, age, size, service, etc., it is also suggested to check overall predicted emissions from the "Excellent" and "Good" categories in the same way, i.e. use EPA factors and then divide by 20 or 3, respectively. • In order to determine which factors to use, a series of questions were developed to index a facility into one of the three categories. These are general guidance, and not definitive in the sense of black or white. Additionally, use of the DuPont Factors may be challenged by State Environmental Agencies since they do vary from EPA prescribed factors. However, past validation efforts gave overall estimates within 10-20% of those based on DuPont factors. For additional information and assistance, please call Tom Kittleman, Ducom 366-4718. Superior factors should only be sued by facilities that use extremely hazardous materials, i.e. phosgene, chlorine or HF. The maintenance culture of these operations is to detect and repair leaks immediately due to the inherent toxicity of the chemicals. Most other processes/facilities will be either excellent or good. The "Excellent" factors listed above should be used only after HONESTLY answering the list of questions attached, and at least 4 or 5 answers are "Yes." otherwise use "Good". QUESTIONS FOR DETERMINING UNIT -SPECIFIC FACTOR CATEGORY 1. Are techniques available and used to routinely locate specific leaks? Examples include S02 bombs, ammonia solution, special detectors (such as those for HCN or phosgene), chemical badges, and sniff testers. 2. Do you perform leak checks in this process area at least once per day? 3. Are specific procedures used on each start-up to minimized fugitive emissions? Examples include hydrostatic tests, special leak tests, etc. 4. Do you have a documented check list startup procedure that helps locate routine leaks? 5. Do you have a formal procedure that requires leaks be repaired in a timely manner, including use of overtime if necessary? DEQ-CFW 00086757