HomeMy WebLinkAboutDEQ-CFW_00072402I . '$ P F 3 60 14 1a ` 01
Technical specification sheet
May2 ens
MDensity
May 007 y
Micro Motion
Gas Density and Specific Gravity Products
The market leader in the supply of precision
measurement solutions for the power, oil, gas,
aerospace and process industries, our range
of transducers and instrumentation for on-line
continuous measurement of density and viscosity
in liquids and gas are renowned for their accuracy
and reliability.
FABRICATION RELEASE
FOR GENERAL CONFORMITY
TO DIMENSIONS & MATERIALS
SPECIFIED
APPROVED
Q APPROVED AS
NOTED
Vent and Valv
input
for
calibration Valvi
gases
Cc lJ S X CE
mieomfi
Series 7812 and 3098 transducers bring you all
the benefits of highly accurate, continuous on-line
measurements of gas density and gas specific
gravity:
• Better control of product quality
• Faster response to changing conditions
• Reduced waste
• Improved safety
• Greater profitability
• Overcomes disadvantages of traditional
sampling techniques
Pressure
regulator
Valve F Valve G`
(merging valve)
Insulating enclosure
Control pressure
indicator
Chamber filling
valve, E
Reference chamber
Pressure control valve
Pressure relief valve
Output a nfice
-� To signal converter
K To vent
EMEF SOM
Process Management
N
O
N
O
O
OI
LL
U
m
0
Technical specification sheet
B12May2007 Density
y
3098 Gas Specific Gravity Transducer
The 3098 is the latest development in a product
line well established as the industry standard for
gas gravitometers. It is the only product that offers
continuous on-line measurements as well as:
• Highest accuracy and
resolution available today; l
• Fast, dynamic response to
process conditions
• Self compensation for gas
compressibility
• Custody transfer approval
The 3098 utilises a resonating element gas
densitometer which is surrounded by a constant
volume reference chamber, V, filled with a fixed
quantity of gas. A diaphragm ensures that the
pressure, P, of the sample gas in the densitometer
is equal to that of the reference gas, and the whole
system is temperature stabilised.
The specific gravity of a gas is the ratio of its
molecular weight, M, to that of standard air.
However, with equalised temperature, T, and
pressure, with supercompressibility effects, Z,
taken into account, the specific gravity and relative
density are equivalent.
The density, ps of the sample gas is measured by
the densitometer.
By definition:
P. = MS.P I V.T.Z,
Similarly, the density of the reference gas is:
pr=M.PIV.T.Z
Since a fixed quantity of the reference gas is
contained in a constant volume:
prlMr=PIV.T.Zr=K
Thus:
ps = K. Ms Zr I Zs
and if the reference gas is the same as the sample
gas:
Zr = ZS and ps = K. Ms
Thus the output of the densitometer is proportional
to the molecular weight - and hence specific
gravity - of the gas.
Applications of the 3098 include:
• Specific Gravity measurement,
Calcuiation of calorific value using AGA 5
• Relative density measurement
These figures apply to the measurement of a typical naluraI gas al a reference pressure of about 6 bars Two gases of known specific
gravity are required for calibration (typically nitrogen and methane). In practice, the accuracy achieved will depend on the care taken in
calibration. An accuracy of 0.1% of reading can readily be obtained.
Density
3098 Ordering information
"erl-MM ATEX insulating enclosure (500 x 500 x 300mm)
ATEX without enclosure'
ATEX insulating enclosure (600 x 800 x 300mm)
NEMA4X insulating enclosure CSA Approval
Without enclosure' CSAApproval
Technical specification sheet
B1253
May 2007
' Please note that the 3098's published performance specification is with
the instrument fitted inside an approved enclosure.
7812 Gas Density Transducer
The 7812 technology is unique
in providing on-line continuous
measurement. It offers:
• Highest accuracy and resolution
available today
• Fast reaction to process
changes
• Low maintenance requirement
• In -situ replacement of filters
• Approved for custody transfer
The 7812 is based on a resonating
cylinder: the density of the gas
flowing through the transducer
changes the natural resonant
frequency of the cylinder.
By maintaining this vibration
and measuring its frequency
electronically, the density of the gas
(which is directly related to mass
flow) can be determined.
Applications of the 7812 include:
• Fiscal gas density measurement to ISO 5167 and AGA 3 standards
• Gas blending
• Direct measurement of ethylene density
0
N
r`
O
O
of
LL
U
m
0
Density
7812 Ordering Information
Technical specification sheet
B1253
May 2007
Range 1.5 -
10 kg/m3
- Fluorocarbon (FPM/FKM)'O' Rings
Range 1.5 -
10 kg/m3
- EP 'O' Rings
Range 9 -
90 kg/m3
- Fluorocarbon (FPM/FKM) 'O' Rings
Range 9 -
90 kg/m3
- EP 'O' Rings
Range 25 -
250 kg/m3
- Fluorocarbon (FP M/FKM) 'O' Rings
Range 25 -
250 kg/m3
- EP 'O' Rings
Range 40 -
400 kg/m3
- Fluorocarbon (FPM/FKM) '0' Rings
Range 40 -
400 kg/m3
- EP 'O' Rings
m
0
tandard Calibration
UKAS Calibration 1.5 - 10 kg/m3 Nitrogen
UKAS Calibration 9 - 90 kg/m3 Nitrogen
WAS Calibration 25 - 250 kg/m3 Nitrogen
UKAS Calibration 40 - 400 ka/m3 Nitrogen
Eactrary set orEton
ndard - (Non -Traceable)
NB:
For correct installation of the 7812 gas density transducer, a number of installation kits are available.
For further information, please contact your nearest sates office.
The Emerson logo is a trade mark and service mark of Emerson Electric Co.
Micro Motion is a registered trademark of Micro Motion Inc.
Mobrey a a registered trademark of Mobrey Ltd.
Solartron® is a registered trademark of Lloyd Instruments Limited, a subsidiary of Ametek, Inc
All other marks are the property of their respective owners
We reserve the right to modify or improve the designs or specdicauons of product and services at any time without notice
USA: International. -
Emerson Process Management Emerson Process Management
Micro Motion, Inc. Mobrey Measurement
7070 Winchester Circle 158 Edinburgh Avenue,
Boulder, CO 80301 Slough, Berks, SL1 4UE. UK
T +1 303-527-5200 T +44 1753 756600
+ 1 800-522-6277 F +44 1753 823589
F +1 303-530-8459 www.mobrey.com�!'i
www micromotion.com E M G 0N.
Process Management
Nitrogen 28.0135
Vinyl Fluoride 46.0442
Predicted
Calculated MWAVG
% VF by wt
% VF
28.0
0
-0.3
29.2
10
9.6
30.4
20
19.6
31.7
30
29.6
33.2
40
39.6
34.8
50
49.6
36.6
60
59.6
38.6
70
69.5
40.8
80
79.5
43.3
90
89.4
46.0
100
99.2
120
100
80
60
40
20
0
25.0 30.0 35.0 40.0 45.0
MW Average
General Information:
Permit code:
Application type:
Engineer/Rev. location:
Regional Contact:
Facility location:
Facility classification:
Clock is OFF
Status is
Comprehensive Application Report for 0900009.11A
DuPont Company - Fayetteville Works - Fayetteville (0900009)
Bladen County
Permit/Latest Revision: 03735/ T36
TV -Minor
Modification
Mike Gordon/RCO
James Moser
Fayetteville Regional Office
Title V
Application is INCOMPLETE
Pending acceptance
Contact Information
Type Name
Technical/Permit Michael E Johnson, Environmental Manager
Authorized Ellis H. McGaughy, Plant Manager
Received
05/13/2011
Initial amount:
$867.00
Fund type:
2333
05/16/2011
Application Dates
Completeness Due Clock Start Calculated Issue Due
08/11/2011
Fee Information
Date received: Amount Due: Add. Amt Rcv'd: Date Rcv'd:
05/13/2011 0.00
Deposit Slip #: Location rec'd: Location deposited:
Address
22828 NC Highway 87 West
22828 NC Highway 87 West
Acceptance Criteria
Received?
Acceptance Criteria Description
Yes
Application fee
Yes
Appropriate number of apps submitted
N/A
Zoning Addressed
No
Source recycling/reduction form
Yes
Authorized signature
N/A
PE Seal
City State ZIP Telephone
Fayetteville, NC 28306-7332 (910) 678-1155
Fayetteville, NC 28306 (910) 678-1546
Completeness Criteria
Received? Complete Item Description
1
DEQ-CFW 00072407
Comprehensive Application Report for 0900009.11A
DuPont Company - Fayetteville Works - Fayetteville (0900009)
05/16/2011
Bladen County
Application Events
Event Start Due Complete Comments Staff
TV - Acknowledgment/Incomplete add info reques@ddl3/2011 06/12/2011 Need A4 form kmhash
Regulations Pertaining to this Permit
Reference Rule
Regulation Description
2D
.1806
Control And Prohibition of Odorous Emissions
2Q
.0317
Avoidance Conditions
2D
.0503
Particulates Fuel Burning Indirect Heat Exchangers
2D
.0515
Particulates Miscellaneous Industrial Processes
2D
.0516
Sulfur Dioxide Emissions Combustion Sources
2D
.0521
Control of Visible Emissions
2D
.0524
New Source Performance Standards
2D
.1100
Control of Toxic Air Pollutants
2D
.1111
Maximum Achievable Control Technology
2
DEQ-CFW 00072408
Comprehensive Application Report for 0900009.11A 05/16/2011
DuPont Company - Fayetteville Works - Fayetteville (0900009)
Bladen County
Audit Information Pertaining to this Application
Column Name Date Chanend Old Value New Value Editor
DEQ-CFW 00072409
�-
�I�Ln/¢L91[.norru�nn'IfCl.1//67�1f7tLQ3�•�•�arntar..w�.
-�.
rq
delivery
IC X-4L
q
Irk
()
"-
fLl
ru
m
Postage
$
M Certified Fee
r-I
Postmark
0 Return Receipt Fee
Here
0
(Endorsement Required)
r
0 Restricted Delivery Fee
(Endorsement Required)
O
r-
CO
Total Postage & Fees
$
r-I
To
O
kent
------------------------------------------------
freet, Apt No.;
----------------
C3r
PO Box No.
PS Form 3800. August 200E
NCDENR
North Carolina Department of Environment and Natural Resources
Division of Air Quality
Beverly Eaves Perdue
Governor
Sheila C. Holman
Director
CERTIFIED MAIL: 70101870000133223714
RETURN RECEIPT RE UESTED
May 16, 2011
Mr. Ellis McGaughy
Plant Manager
DuPont Company - Fayetteville Works
22828 NC Highway 87 West
Fayetteville, NC 28306
SUBJECT: Receipt of Permit Application
Modification of Permit No. 03735T36
Application No. 0900009.11 A
DuPont Company - Fayetteville Works
Facility ID: 0900009, Fayetteville, Bladen County
Dear Mr. McGaughy:
Dee Freeman
Secretary
Your air permit application (0900009.11A) for DuPont Company - Fayetteville Works,
located in Bladen County, North Carolina was received by this Division on May 13, 2011.
Submittal of your air permit application request must include the following missing items:
A permit application processing fee:
Under the new permit application processing fee schedule effective January 1, 2011, your
required fee is $867.00. The appropriate application fee amount was received.
Pending review of your application and based on the required fee amount indicated
above, you may be required to pay an additional amount.
Number of Copies:
The appropriate number of copies was received.
A Survey of Facility Reduction and Recycling Activities (Form: A4)
Your application did not contain a Survey of Facility Reduction and Recycling Activities
Form. North Carolina General Statute 143-215.108(g) requires that each air permit application
Permitting Section
1641 Mail Service Center, Raleigh, North Carolina 27699-1641
2728 Capital Blvd., Raleigh, North Carolina 27604 Carolina
Phone: (919) 715-62371 FAX: (919) 733-53171 Internet: www.ncair.org/
An Equal Opportunity 1 Affirmalive Action Employer Vatu
Mr. McGaughy
May, 16, 2011
Page 2
for a new permit or any modification of an existing permit contain a written description of current
and projected plans to reduce the emissions of air contaminants by source reduction and recycling.
Therefore, your application must contain a completed Form A4.
Signature of An Authorized Official:
Your application was signed by an authorized official as defined by 15A NCAC 2Q.03040).
In summary, this application did not contain all the required elements as indicated above and
has not been accepted for processing. This information must be submitted and contain the above
requested information. The requested information must be submitted to our Office within thirty
(30) days or the application may be returned.
Should you have any questions concerning this matter, please contact Mike Gordon at (919)
715-6243.
Sincer 1 ,
Donald van der Vaart, Ph.D., P.E., J.D.
Chief
cc: Fayetteville Regional Office Files
Redacted
.............................................................................................................................................................