HomeMy WebLinkAboutDEQ-CFW_00045694WaStedWdanaget8 ent
ENVIRONMENTAL QUALITY
July 21, 201.7
Mr. Kevin P. Garon
Principal Project Director
Chernours Corporate Perarediat:ion Group
Th.e Chemours Company
3000 Old Chapel Lane
Chaflott:e, North Carolina 2821.0
Re: NCDEQ Approval of Groundwater Sampling Work Plana
Chernours Company Facility
Fayetteville, North Carolinas
EPA ID fl NCD 047 368 642
Dear Mr. G arom
ROY COOPER
MICHAEL S. REGAN
sec etwYy
MICHAEL sCCTT
Director
The North Carolina Department of Environmental Quality (NCI)E(2) has reviewed the
"Groundwater Sampling Work .Plan "(Plan), dated July 17, 2017, prepared by Parsons for the facility
located at 22828 NC Highway 87 West, Fayetteville, North Carolina. Based upon the technical
revicy,�v of the Plan NCI.)EQ has determined that: the docurnent is acceptable under the following
conditions and cornmenm
1., The report: should include a table with a history of previous sampling events an.d
their results for comparison purposes with the current sampling event.
2. The Plan should be signed by a designated individual identified by your Consultant,
1 Provide a ge€alo€:action for sampling Point SWM-01, the water intake locatiori aand the
outfall location (NCDEQ has geolocations for the other sampling points).
4' Clarify the list of'compounds in Table 1 to iraclnr-le a column for CAS numbers to
ensure the split: samples are analyzed for the correct target: analytes.
S, The Facility must: send NCDEQ the raw laboraata:aryr data as ;moan as it is Finalized by
the laboratory.
Ca. The DWM GC/MS library search will be performed on the Method 537 SPIN extract,
We encourage the Facility to do the sauce search,
7, EPA Method '337 specifies nitrile gloves forsampling activities,
h. Identify which of the processors listed in the table in Section 1.2 involve the PFAS
compound specified by C ASN 13252-1.5-6.
State of North Carolina I Environmental Quality ;1�%rite utariaggrner,;
217 West Jones Street 116404aii Service Center Raleigh, North Carol!na 2709 -1646
9197078200
DEQ-CFW 00045694
NCDEQ Chemours Approval letter
GW Sampling Plan, July 21, 2017, Page 2
9. Preservation is required only for chlorinated waters, Recommend that samples are
not preserved, or explain why preservation is recommended,
We look forward to the eventful successful completion of site activities and reviewing the
subsequent Report.
Please do not hesitate to contact us should you have any questions.
Sincerely,
C/ Joe Ghiold, Project Manager
Facility Management Branch
Hazardous Waste Section
Ec: Kevin P. Garon, Chemours
Tracy Ovbey, Parsons
Bud McCarty, NCDEQ
Harvi Cooper, NCDEQ
Julie Woosley, NCDEQ
Michael Johnson, Chemours
Sandy Mort, NCDEQ
State of North Ca3 olin,9 I ErMrornenlal Quafi-,y I 1,Va5;te NialaocfnenE
DEQ-CFW-00045695