HomeMy WebLinkAboutDEQ-CFW_00025300Hazardous Waste Section
File Room Document Transmittal Sheet
Your Name: Larry Stanley
EPA ID: N C D 0 4 7 3 6 8 6 4 2
Facility Name: DuPont -Fayetteville
Document Group: Groundwater (GW)
Document Type: Groundwater Monitoring Report (GMR)
Description: Letter report: PFOA groundwater monitoring results
Date of Doc: 7/20/2011
Author of Doc: Mike Johnson (DuPonj
File Room Use Only
Date Recieved by File Room:
Date Scanne,41:
Month
Day
Year
ZOk
Scanner's Initials: eKb
W]
DEQ-CFW-00025300
DuPont Fluoroproducts
Fayetteville Works Plant
22828 NC Highway 87 West
Fayetteville, NC 28306-7332
July 20, 2011
Mr. Larry Stanley
NC Division of Waste Management
Hazardous Waste Section
1646 Mail Service Center
Raleigh, NC 27699-1646
SUBJECT: 2011 Groundwater Data Transmittal
DuPont Company — Fayetteville Works
Permit No. NCD 047 368 642
The attached Table I shows the on -site groundwater monitoring results for the compound
frerfiuorooctanoic acid ("PFOA") from the sampling event in March 2011.
The shallow well (SMW-05) located north of and adjacent to the PPA Manufacturing Facility and
the temporary piezometer (INSITU #2R SHALLOW) located north-northeast of the PPA
Manufacturing Facility and near the facility's northern boundary, were both found to be dry and could
not be sampled.
Please feel free to call me at 910-678-1155 if you have any questions.
Environmental Manager
cc: Jamie VanBuskirk, DuPont CRG, Charlotte
Jenny Liu, DuPont, Wilmington, DE
Toni Krasnic, EPA, Washington DC (via Email to krasnic.toni@epa.gov)
E.I. du Pont de Nemours and Company
DEQ-CFW-00025301
Sample ID
Monitoring
PFOA
(Sample Description)
Date
(Ual)
LTW-01
Onsite monitoring well located near the facility's eastern property
03/01/2011
0.079
line along the Cape Fear River in the surficial groundwater; east of
the APFO Manufacturing Facility.
LTW-02
Onsite monitoring well located near the facility's eastern property
03/01/2011
ND (<0.003)
line along the Cape Fear River in the surficial groundwater; east-
southeast of the APFO Manufacturing Facility.
LTW-03
Onsite monitoring well located near the facility's eastern property
03/02/2011
ND (<0.003)
line along the Cape Fear River in the surficial groundwater; east-
southeast of the APFO Manufacturing Facility.
LTW-04
Onsite monitoring well located near the facility's eastern property
03/02/2011
NQ (<0.014)
line along the Cape Fear River in the surficial groundwater;
southeast of the APFO Manufacturing Facility.
LTW-05
Onsite monitoring well located near the facility's eastern property
03/02/2011
ND (<0.003)
line along the Cape Fear River in the surficial groundwater;
southeast of the APFO Manufacturing Facility.
INSITU #1 Shallow
Onsite monitoring well located near the facility's northern property
03/01/2011
ND (<0.003)
line in the upper level of the surficial groundwater; north-northeast
of the APFO Manufacturing Facility.
MW-Is
Onsite monitoring well located near the inactive Biosludge Lagoon
03/01/2011
0.074
area in the perched groundwater above a local clay feature; south of
the APFO Manufacturing Facility.
SMW_01
Onsite monitoring well located east of the Construction Gate
03/01/2011
NQ (<0.014)
entrance near Highway 87 in the surficial aquifer; southwest of the
APFO Manufacturing Facility.
SMW_05P
Onsite monitoring well located north of and adjacent to the APFO
03/02/2011
3.6
Manufacturing Facility, in the surficial groundwater beneath a local
clay feature.
Analytical results are expressed in micrograms per milliliter (µg/ml,) or parts per billion (ppb).