HomeMy WebLinkAboutDEQ-CFW_000562255105 Ms. Hope Walters 22828 NC Hwy. 87 W Fayetteville, NC 28306 SUBJECT: North Carolina Wastewater/Groundwater Laboratory Certification (NC WW/GW LC) Maintenance Inspection Dear Ms. Walters: Copies of the checklists completed during the inspection may be requested from this office. Thank you for your cooperation during the inspection. If you wish to obtain an electronic copy of ihis report by electronic mail, or if you have questions or need additional information please contact me at (828) 296-4677. Gary Francies Laboratory Section DEN,R DV,,1RVVQP Laboratory Section NC Wastewater/Groundwater Laboratory Certification Branch 1623 Mail Service Center. Raleigh, North Carolina 27699-1623 Location: '1405 Reedy Creek Road. Raleigh, North Carolina 27607-6445 Phone: 919-733-3908 1, FAX: 919-713-6241 Internet: www,dw�lab.org An Equal C%o.,fun;fy, Affirmanve Anon Employer DEQ-CFW-00056225 Laboratory Cert. #: 5105 Laboratory Name: DuPont Company - Fayetteville Works Inspection Type: Field Maintenance Inspector Name(s): Nick Jones Inspection Date: January 28, 2014 Date Report Completed: January 29, 2014 Date Forwarded to Reviewer: January 29, 2014 Reviewed by: Chet Whiting Date Review Completed: January 3l,2014 Cover Letter to use: El Insp. Initial El Insp. Reg. El Insp. No Finding Fj Insp. CP El Corrected Unit Supervisor/Chemist III: Gary Francies Date Received: 1/31/2014 Date Forwarded to Linda: 2/10/2014 �JL Date Mailed: abdA DEQ-CFW-00056226 LABORATORY NAME: NPDES PERMIT #: ADDRESS: CERTIFICATE #: DATE OF INSPECTION: TYPE OF INSPECTION: AUDITOR(S): LOCAL PERSON(S) CONTACTED: I "W0619DOIKSM V DuPont Company - Fayetteville Works NCO003573 22828 NC Hwy. 87 W Fayetteville, NC 28306 5105 January 28, 2014 Industrial Maintenance Nick Jones Hope Walters and Jamie Lewis i- 96 . 0 1 . I a- -0 0 . -a - - - 0 - # . - - - W19II119111ty a - -4 Current quality assurance policies for Field Laboratories and approved procedures fortha. analysis of the facility's currently certified parameters were provided at the time of thit inspection. MEMO I I i Ii I J1 I ill 1:3 k, I 17A I• 0 n DEQ-CFW-00056227 Page 2 05 - DuPont Company - Fayetteville Works for a period of five years. Consumable materials such as pH buffers and lots of pre -made standards are included in this requirement. Demonstration of acceptable corrective action (i.e., an updated traceability log which includes Date Received, Date Opened, Lot Number, and Expiration Date) was received by email on 1/28/2014. No further response is necessary for this finding. Documentation Comment: The benchsheet used by the laboratory did not contain all of the necessary labeling information. No units of measure (S.U.) are associated with the pH meter calibration results on the pH benchsheet. The Facility Name and instrument ID were not documented on the pH benchsheet. The NC WW/GW LC Approved Procedure for the Analysis of pH document states: The following must be documented in indelible ink whenever sample analysis is performed. 3. Sample site including facility name and location, ID, etc. 12. Instrument identification. The North Carolina Administrative Code, 15A NCAC 2H .0805 (g) (1) states: The field bench sheets must provide a space for the signature or initials of the analyst, and proper units of measure for all analyses. Demonstration of acceptable corrective action (i.e., an updated benchsheet which includes proper units of measure for pH calibration, facility and instrument ID for pH) was received by email on 1/28/2014. No further response is necessary for this finding. Comment: The benchsheet used by the laboratory did not contain all of the necessary labeling information. The Facility Name and instrument ID were not documented on the Temperature benchsheet. The NC WW/GW LC Approved Procedure for the Analysis of Temperature document states: The following must be documented in indelible ink whenever sample analysis is performed. 3. Sample site including facility name and location, ID, etc. 9. Thermometer/instrument identification. Demonstration of acceptable corrective action (i.e., an updated benchsheet which includes facility name and instrument ID for Temperature) was received by email on 1/28/2014. No further response is necessary for this finding. lan. URITIVA Comment: The laboratory is not documenting Proficiency Testing (PT) sample analyses in the same manner as environmental samples. The NC WW/GW LC Proficiency Testing Requirements document states: All PT sample analyses must be recorded in the daily analysis records as for any environmental sample. This serves as the permanent laboratory record. Notification of acceptable corrective action (i.e., a statement that all PT sample analyses will be recorded in the daily analysis records as for any environmental sample.) was received by e-mail on 1/29/2014. No further response is necessary for this finding. •M I I I I . : I I DEQ-CFW-00056228 ILM LM MOM1,143111 All findings noted during the inspection were adequately addressed prior to the completion of this report. The inspector would like to thank the staff for its assistance during the inspection and data review process. No response is required. Report prepared • Nick Jones F'rITFF,rjT'& DEQ-CFW-00056229