Loading...
HomeMy WebLinkAboutNCG551567_Compliance Evaluation Inspection_20181220 Y -Na. w.q ROY COOPER Guvernor tqt MICHAEL S.REGAN 'V� C' Sect"PfGI'y 4. f5r'_-`-,•t� .5' Qr WAM�t y LINDA CULPEPPER Intel ell Duertor NORTH CAROLINA Environmental Quality RECEIVED/DENRIDWR December 20, 2018 JAN 0 2 2019 Kimberly Clark water Resources 830 Log Barn Road Permitting Section Pittsboro,NC 27312 Subject: Compliance Evaluation Inspection 1827 Washington Dr. Single Family Wastewater Treatment System Permit No. NCG551567 Orange County Dear Ms. Clark: On December 4, 2018, Cheng Zhang from the Raleigh Regional Office visited the single-family residence (SFR) wastewater treatment system at 1827 Washington Dr. in Orange County to evaluate compliance with the above permit to discharge wastewater. The checked boxes below show what conditions were noted at your facility: ® In compliance: You are reminded to regularly maintain the chlorine disinfection and dechlorination systems, have the effluent sampled once a year, and have the septic tank pumped out every 3 to 5 years. Your good record of operation and meeting the permit requirements is highly commended. ❑ Your home is improperly plumbed: Some of the wastewater discharges are going directly to the environment without first passing through the treatment system. This must be corrected immediately. Please submit a schedule to this office within 20 days of receipt of this letter that states your plan for correcting this deficiency. The work is to be completed within the next 3 months. n Disinfection: Your system is lacking disinfection, either chlorine tablets or a UV light system. New rules put into place on August 1, 2007 require all SFR systems to have a means of disinfection (and dechlorination when chlorine tablets are used to disinfect, if the system was installed since that date). Since your system had no disinfection, the installation is to include a chlorine tablet dispenser, a contact chamber capable of providing a minimum 30 minute contact time, and another tablet dispenser that will hold dechlorination tablets. Please submit a schedule to this office within 20 calendar days of receipt of this letter that states your plan for correcting this deficiency. North Carolina Department of Environmental Quality I Division of Water Resources I Raleigh Regional Office 3800 Barrett Drive 11628 Mail Service Center I Raleigh,North Carolina 27699-1628 gig 7a1 a9nn ❑ Treatment tablets missing or are wrong kind: You are responsible for always having chlorine tablets and dechlorination tablets (if a required part of your system) in place. They must be the kind for wastewater treatment and not for swimming pools. n Dechlorination: Your system was installed after August 1, 2007, so must have a means of dechlorination located downstream of the chlorinator and its contact chamber. See Disinfection paragraph above. Please submit a schedule to this office within 20 calendar days of receipt of this letter stating your plan for correcting this deficiency. n Pumping the septic tank: The septic tank should be pumped out every 3 to 5 years. A pumping company can check the status periodically and determine when pumping is required. ❑Failure to analyze the effluent: The effluent that is discharged from your system must be analyzed once each year. See Part I (A) of your permit about his requirement. A list of NC certified laboratories that provide this service was left at your residence during the inspection. Make arrangements for sampling to be carried out within the next 3 months, and submit results to this office within 3 weeks after the sampling has been done. n Locations of treatment units are unknown: Determine this and report to this office within 30 days of receipt of this letter with a sketch or map. n Other: If you have questions or comments about this inspection or the requirements to take corrective action, please contact Cheng Zhang or me at 919-791-4200. Licensed plumbers should be used to make plumbing changes within your home. Contractors for installing disinfection or other equipment may be found in the Yellow Pages under Environmental Consultants. Sincerely, /o >ck Bolich, L.G. Assistant Supervisor Division of Water Resources Raleigh Regional Office Attachments cc: RRO/SWP Files NPDES Permitting Unit Files—Charles Weaver North Carolina Department of Environmental Quality I Division of Water Resources 512 North Salisbury Street 11617 Mail Service Center;Raleigh,North Carolina 27699-1617 Q1 q 7(17 QOO(1 United States Environmental Protection Agency Form Approved EPA Washington,D C 20460 OMB No 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A National Data System Coding(t e,PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 [ j 2 IL I 3 I NCG551567 I11 12 I 18/12/04 117 18 19 Ls]I 201 211111 I I I I I I II I I I I I I I I I I I I I I I I I I I I I I I II I I I I I 166 Inspection Work Days Facility Self-Monitonng Evaluation Rating B1 QA Reserved 67I I 70I I 711 I 72. I n, I 731 I 174 Jill I I I I I 180 Section B Facility Data L-1 Name and Location of Facility Inspected(For Industrial Users discharging to POTW,also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 11 16AM 18/12/04 13/08/06 1827 Washington Drive 1827 Washington Dr Exit Time/Date Permit Expiration Date Hillsborough NC 27278 11 27AM 18/12/04 18/07/31 Name(s)of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data /1/ Name,Address of Responsible Official/Title/Phone and Fax Number Contacted Kimberly Clark Jones, //919-548-9946/ No Section C Areas Evaluated During Inspection(Check only those areas evaluated) • Other Section D Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s)and Signature(s)of Inspector(s) Agency/Office/Phone and Fax Numbers Date Cheng Zhang ^ RRO WQ//919-791-4200/ e1 r2_,z0/2aI ? Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 35 0-3(Rev 9-94)Previous editions are obsolete ' Page# 1 / NPDES yr/mo/day Inspection Type 1 31 NCG551567 I" -I2I 18/12/04 117 18 I(;I ' Section D Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) The system was installed In 2016. The permittee has a contract with McFarland Septic to service and maintain the system. Effluent has been sampled and analyzed annually. Page# 2