Loading...
HomeMy WebLinkAboutWQ0030664_Final Permit_20111116L7vtN-KA?FA NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Governor Director November 16, 2011 Daniel & Kelly Purvine 3740 Mason Rd. New Hill, NC 27562-9170 Subject: Permit No. WQ0030664 Purvine Single -Fancily Residence Wastewater Irrigation System Wake County Dear Daniel & Kelly Purvine: Dee f=reeman Secretary In accordance with your permit modification request received September 15, 2011, and subsequent additional information received November 4, 2011, we are forwarding herewith Permit No. WQ0030664, dated November 16, 2011, to Daniel and Kelly Purvine, for the construction and operation of the subject single-family residence wastewater treatment and irrigation facilities. This permit shall be effective from the date of issuance until December 31, 2015, and shall be subject to the conditions and limitations as specified therein. An extension shall be requested at least six months prior to the expiration of this permit. Upon receipt of the request, the Division will review the adequacy of the facility described therein and, if warranted, will extend the permit for such period of time and under such conditions and limitations as it may deem appropriate. Please pay particular attention to the operation and maintenance requirements listed in Section H. Failure to establish an adequate system for collecting and maintaining the required operational information shall result in future compliance problems. If any parts, requirements or limitations contained in this permit are unacceptable, the Permittee has the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request shall be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings at 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. AQUIFER PROTECTION SECTION' 1V-- Servico Cente-, Raleg�" Not". Carni;na 27689-1K Lmlvom 2728 Car'lal kilevard Ralei--, Nort, Caro:'.za 27u04 Pnom: M-733.3221', rte.}:',: M 55 5& F :2: 51, ='15.60416 '� Customer Sentce: 1-877-C23.674E m[erre;; www.ncwaterouaiiiy.org 011- 1\ _ o LZit1C�s T�P Daniel and Kelly Purvine WWTS November 15, 2011 Page 2of 2 One set of approved plans is being forwarded to you. If you need additional information concerning this matter, please contact Larry Wade at (919) 715-6185 or lany.wade@ncdenr.gov. Sincerely, coleen H. Sullins cc: Wake County Health. Department Raleigh Regional Office - Aquifer Protection Section Technical Assistance and Certification Unit Mr. Kevin Davidson PE, Agri -Waste Technology, Inc. APS Central Files (WQ0030664) LAU Files NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH SINGLE FAMILY RESIDENCE SURFACE IRRIGATION PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO Daniel and Felly Purvine Wake County FOR THE construction and continued operation of a 480 gallon per day (GPD) surface irrigation wastewater treatment and disposal system consisting of a 1,200 gallon baffled septic tank with effluent filter, a 420 square foot subsurface sand filter, a tablet chlorinator followed by a 73 gallon chlorine contact chamber, a 4,700 gallon storage/pump tank, a 10 GPM,1/2 HP, 8 stage pump with a high water alarm light and buzzer, a 16,380 square foot drip irrigation area consisting of 4 zones of 4,095 square feet each with 15 drip lines 91 feet long on 3 foot centers and all associated piping and appurtenances, to serve the Daniel and Kelly Purvine residence with no discharge of wastes to the surface waters, pursuant to the application received August 1, 2006, and modification request received on September 15, 2011, and in conformity with the project plan, specifications, and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. This permit shall be effective from the date of issuance until December 31, 2015 and shall be subject to the following specified conditions and limitations: I. PERFORMANCE STANDARDS Upon completion of construction and prior to operation of this permitted facility, a certification must be received from a professional engineer certifying that the permitted facility has been installed in accordance with this permit, the approved plans and specifications, and other supporting materials. If this protect is to be completed in phases_and_partially certified, you shall, retain, the responsibility to track further construction approved under the same permit, and shall provide a final certificate of completion once the entire proiect has been completed. Mail the Certification to the Land Application Unit, 1636 Mail Service Center, Raleigh, NC 27699- 1636. WQ0030664 Version 1,0 ' Shell Version 091027 Page 1 of 8 2. The Raleigh Regional Office, telephone number (919) 791-4200, shall be notified at least forty- eight (48) hours in advance of operation of the installed facilities so that an in-place inspection can be made. Such notification to the regional supervisor shall be made during the normal office hours from 8:00 a.m. until 5:00 p.m. on Monday through Friday, excluding State Holidays. The surface irrigation facilities shall be effectively maintained and operated at all times so that there is no discharge to surface waters, nor any contamination of ground waters, which will render them unsatisfactory for normal use. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions or failure of the irrigation area to adequately assimilate the wastewater, the Permittee shall take immediate corrective actions including those actions that may be required by the Division of Water Quality, such as the construction of additional or replacement wastewater treatment and disposal facilities. 4. The issuance of this permit shall not relieve the Permittee of the responsibility for damages to surface or ground waters resulting from the operation of this facility. The sand media of the subsurface sand filter must comply with the Division's sand specifications. The Engineer's Certification will serve as evidence that these specifications have been met. 6. A leafage test shall be performed on the septic tank and storage/pump tank(s) to insure that any exfiltration occurs at a rate, which does not exceed twenty (20) gallons per twenty-four (24) hours per 1,000 gallons of tank capacity. The Engineer's Certification will serve as proof of compliance with this condition. 7. If excavation into bedrock is required for the installation of the septic tank or sand filter, the pit shall be lined with a 10 -mil synthetic liner. 8. A sanitary tee and filter shall be installed on the effluent pipe of the septic tank. The Engineer's Certification will serve as evidence that these specifications have been met. 9. The residuals generated from these treatment facilities must be disposed in accordance with General Statute 143-215.1 and in a manner approved by the Division. 10. Diversion or bypassing of the untreated wastewater from the treatment facilities is prohibited. 11. The following buffers shall be maintained: a. 100 feet between wetted area and any residence or places of public assembly under separate ownership, b. 50 feet between wetted area and property lines, C. 100 feet between wetted area and wells, d. 50 feet between wetted area and drainage ways or surface water bodies, C. 50 feet between wetted area and public right of ways, f. 100 feet between treatment/storage units and any wells, and g. 50 feet between treatment units and property lines. 12, The pump tank(s) shall have functional audible and visual high water alarms that are external to any structure. 13. The disposal system shall be connected to a rain or moisture sensor that shall indicate when wastewater application is not appropriate in accordance with Condition 11(4). 14. The existing vegetation on the drip irrigation site shall not be cleared or disturbed except to the extent necessary to install the dripline. WQ0030664 Version 1.0 "Shell Version 091027 Page 2 of 8 15, All tank access risers shall extend at lest six (6 ) inches above finished grade and shall be provided with properly secured covers. II. OPERATION AND MAINTENANCE REQUIREMENTS The facilities shall be properly maintained and operated at all times. 2. Upon classification of the wastewater treatment and surface irrigation facilities by the Water Pollution Control System Operators Certification Commission (WPCSOCC), the Permittee shall designate and employ a certified operator to be in responsible charge (ORC) and one or more certified operator(s) to be back-up ORC(s) of the facilities in accordance with 15A NCAC 8G .0201. The ORC shall visit the facilities in accordance with 15A NCAC 8G .0204 or as specified in this permit and shall comply with all other conditions specified in these rules. 3. A suitable year round vegetative cover shall be maintained. 4. Irrigation shall not be performed during inclement weather or when the ground is in a condition that will cause runoff. 5. Adequate measures shall be taken to prevent wastewater runoff from the irrigation field. 6. The application rate shall not exceed a cumulative loading of 17.2 inches over any twelve (12) month period at an instantaneous application rate not to exceed 0.30 inches per hour. 7. The facilities shall be effectively maintained and operated as a non -discharge system to prevent the discharge of any wastewater resulting from the operation of this facility. S. No type of wastewater other than that from the Purvine residence shall be emitted onto the irrigation area. 9. No traffic or equipment shall be allowed on the disposal area except while installation occurs or while normal maintenance is being performed. 10. The irrigation field shall be fenced with at least a two -strand wire fence. 11. Wastewater treatment units open to the atmosphere shall have restricted access and pump control panels shall be locked. 12. The Permittee is responsible for the operation and maintenance of the entire treatment and disposal system including, but not limited to, the following items: a. The septic tank shall be checked annually and pumped out as needed. The septic tank effluent filter shall be checked and cleaned at the same frequency of the septic tank. b. The tablet chlorinator shall be checked every week. Tablets shall be added to provide proper chlorination. c. The storage, pump, and alarm systems shall be inspected monthly. The scum layer shall be removed at the same interval as the septic tank is cleaned out. d. The system shall be inspected monthly to make certain of the proper operation of the drip line, that the vegetative growth allows a proper drip pattern, that the soil is assimilating the disposed treated wastewater with no surface runoff, and that no objectionable odors are being generated. III. MONITORING AND REPORTING REQUIREMENTS WQ0030664 Version 1.0 Shell Version 091027 Page 3 of 8 I . Any monitoring deemed necessary by the Division to insure surface and ground water protection will be established and an acceptable sampling reporting schedule shall be followed. 2. The Permittee shall maintain records of all maintenance performed on the system and irrigation area, as required in Condition 11(12) for a minimum of five years. This information shall be provided to the Division upon request. 3. Noncompliance Notification: The Permittee shall report by telephone to the Raleigh Regional Office, telephone number (919) 791-4200, as soon, as possible, but in no case more than 24 hours or on the next working day following the occurrence or first knowledge of the occurrence of any of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater treatment, such as mechanical or electrical failures of pumps, emitters, etc:; or b. Any failure of a pumping station or treatment facility resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Occurrences outside normal business hours may also be reported to the Division's Emergency Response personnel at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting such occurrences by telephone shall also file a written report in letterform within five (5) days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. N. INSPECTIONS Adequate inspection., maintenance, and cleaning shall be provided by the Permittee to insure proper operation of the subject facilities. 2. Any duly authorized officer, employee, or representative of the Division may, upon presentation of credentials, enter and inspect any property, premises or place on or related to the disposal site or facility at any reasonable time for the purpose of determining compliance with this permit, may inspect or copy any records that must be maintained under the terms and conditions of this permit, and may obtain samples of groundwater, surface water, or leachate. V. GENERAL CONDITIONS 1. This permit shall become void unless the facilities are constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data. 2. This permit is effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. This permit is not transferable. In the event there is a desire for the facilities to change ownership, or there is a name change of the Permittee, a formal permit request must be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request will be considered on its merits and may or may not be approved. 4. Upon the availability of a municipal or regional sewerage collection system, the subject ZP wastewater treatment facilities shall be abandoned and all wastewater discharged into the municipal or regional sewerage system. WQ0030664 Version 1.0 Shell Version 091027 Pace 4 of 9 5. Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to an enforcement action by the Division in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. 6. The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances, which may be imposed by other government agencies (local, state, and federal), which have jurisdiction. This permit may be revoked if the Permittee fails to abide by the conditions of the "Operation and Maintenance Agreement" previously signed by the Permittee. 8. The Permittee shall retain a set of approved plans, specifications and operation and maintenance manual of the subject facility for the life of the project. 9. The Permittee shall pay the annual administering and compliance fee within 30 days of being billed by the Division. Failure to pay the fee accordingly may cause the Division to initiate action to revoke this permit as specified by ISA NCAC 2T .0105 (e)(3). 10. The Permittee, at least six (6) months prior to the expiration of this permit, shall request its extension. Upon receipt of the request, the Commission will review the adequacy of the facilities described therein, and if warranted, will extend the Permit for such period of time and under such conditions and limitations, as it may deem appropriate. Permit issued this the 16th of November 2011. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION 0-62-0�- �, (-,J . Colleen H. Sullins Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0030664 WQ0030664 Version 1.0 Shell Version 091027 Page 5 of 8 WQ00301664 Version 1.0 Shell Version 091027 Page 6 of 8 Permit No. WQ0030664 Daniel & Kelly Purvine Purvine WWTS ENGINEERING CERTIFICATION ❑ Partial ❑ Final Single Family Residence November 16, 2011 WakeCounty In accordance with 15A NCAC 02T .0 116, I, as a duly registered Professional Engineer in the State of North Carolina, having the Permittee's authorization to ❑ periodically ❑ weekly ❑ fully observe the construction of the permitted facility, hereby state to the best of my abilities that due care and diligence was used in the observation of the construction, such that the facility was built within substantial compliance and intent of this permit, the Division approved plans and specifications, and other supporting documentation. [] Any variation to this permit, the Division approved plans and specifications, and other supporting documentation has been documented in the attached as -built drawings, and shall serve as the Permittee's minor modification request to amend the permit accordingly. Provide a brief narrative description of any variations: Professional Engineer's Name Engineering Finn Mailing Address City Telephone E-mail State Zip NC PE Seal, Signature & Date THE COMPLETED ENGINEERING CERTIFICATION, INCLUDING ALL SUPPORTING INFORMATION AND MATERIALS, SHALL BE SENT TO THE FOLLOWING ADDRESS: NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY AQUIFER PROTECTION SECTION LAND APPLICATION UNIT By U.S. Postal Service: By Courier/Special Delivery: 1636 MAIL SERVICE CENTER 2728 CAPITAL BOULEVARD RALEIGH, NORTH CAROLINA 27699-1636 RALEIGH, NORTH CAROLINA 27604 WQ0030664 Version 1.0 Shell Version 091027 Pave 7 of 8