HomeMy WebLinkAboutWQ0020822_Final Permit_20081213wA 7'�-9
p Michael F. Easley, Governor
O' G
�J p William G. Ross Jr., Secretary
> , .DLU,,a:; North Carolina Department of Environment and Natural Resources
Q
Coleen H. Sullins, Director
Division of Water Quality
December 13, 2008
KEITH AND PATRICIA BRIDGES
319 CIRCLE PARK PLACE
CHAPEL HILL, NC 27517
Subject: Permit No. WQ0020822
Keith and Patricia Bridges SFR
Surface Drip Facility
Chatham County
Dear Mr, and Mrs. Bridsnes:
In accordance with your application received October 20, 2008, we are forwarding herewith Permit
No. WQ0020822 dated December 1.3, 2008, to Keith and Patricia Bridges for the construction and operation
of the subject single-family wastewater treatment and surface irrigation facilities located at 40 Perfect
Moment Drive, Durham., NC 27713. This permit shall be effective from the date of issuance until November
30, 2013, shall void Permit No. WQ0020822 issued June 27, 2008, and shall be subject to the conditions and
limitations as specified therein.
Please pay particular attention to the monitoring requirements in this permit. Failure to establish an
adequate system for collecting and maintaining the required operational information will result in future
compliance problems. Note: Upon sale of this property, a change of ownership request shall be submitted in
accordance with Condition V, 3,
If any parts, requirements, or limitations contained in this permit are unacceptable, you have the
right to request an adjudicatory hearing upon written request within thirty (30) days following receipt of this
permit. This request must be in the form of a written petition, conforming to Chapter 150B of the North
Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center,
Raleigh, NC 27699-6714. Unless such demands are made this permit shall be final and binding.
If you need additional information concerning this matter, please contact Michael Rogers at (919)
715-6166.
Sincerely,
\1 �',� U*
oleen H. Sullins, Director
cc: Chatham County Environmental Health Department
Raleigh Regional Office - Aquifer Protection Section
Technical Assistance and Certification Unit
APS Central Files
LAU Files
Fran McPherson — DWQ Budget Office
NOne Carolina
�/V�11111i�%I
Aquifer Protection Section 1636 Mail Service Center Raleigh, NC 27699-1636 Phone (919) 733-3221 Customer Service
Internet: http://h2o.enr.statenc.us 2728 Capital Boulevard Raleigh, NC 27604 Fax (919) 715-0588 1-877-623-6748
Fax (919)715-6048
An Equal OpportunitylAf nnafte Action Employer— 50% Recycled110% Post Consumer Paper
NORTH CAROLINA
ENVIRONMENTAL MANAGEMENT COMMISSION
DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES
RALEIGH
SINGLE FAMILY RESIDENCE SURFACE IRRIGATION PERMIT
16
In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended,
and other applicable Laws, Rules, and Regulations
PERMISSION IS HEREBY GRANTED TO
Keith and Patricia Bridges
Chatham County
FOR THE
construction and continued operation of a 600 gallon per day (GPD) surface drip irrigation wastewater treatment
and disposal system consisting of a 1,500 gallon baffled septic tank with effluent filter, dual re -circulating 20
square foot Advantex — AX20 Filter with VeriComm control panels, a 7 GPM ultraviolet disinfection unit
(International Water -Guard model IWG 1-LV-WW-3) capable of sterilizing flow rates up to 10 GPM as long as
the effluent quality treated by the unit does not exceed 15 mg/1 BOD and 15 mg/1 TSS, a 2,500 gallon storage and
dosing tank, a 20 GPM pump operating at 110 feet of TDH, audio and visual high water alarms, rain sensor, and
13,419 square feet of drip irrigation area with approximately 4,473 linear feet of drip line containing 2,237
emitters to serve the Bridges Residence located at 40 Perfect Moment Drive, Durham, NC 27713 (Hills of
Rosemont Subdivision Lot No. 41), and all associated piping and appurtenances with no discharge of wastes to
the surface waters, pursuant to the application received October 20, 2008, and in conformity with the project plan,
specifications, and other supporting data subsequently filed and approved by the Department of Environment and
Natural Resources and, considered a part of this permit.
This permit shall be effective from the date of issuance until November 30, 2013, shall void Permit No.
WQ0020822 issued June 27, 2008, and shall be subject to the following specified conditions and limitations:
I. PERFORMANCE STANDARDS
Upon completion of construction and prior to operation of this permitted facility, a certification must
be received from a professional engineer certifying that the permitted facility has been installed in
accordance with this permit, the approved plans and specifications, and other supporting materials. If
this project is to be completed in phases and partially certified, you shall retain the responsibility to
track further construction approved under the same permit. and shall provide a final certificate of
completion once the entire project has been completed. Mail the Certification to the Land
Application Unit, 1636 Mail Service Center, Raleigh, NC 27699-1617.
2. The Raleigh Regional Office, telephone number (919) 791-4200, shall be notified at least forty-eight
(48) hours in advance of operation of the installed facilities so that an in -place inspection can be
made. Such notification to the regional supervisor shall be made during the normal office hours from
8:00 a.m. until 5:00 p.m. on Monday through. Friday, excluding State Holidays.
WQ0020822 Pagel
3. The surface irrigation facilities shall be effectively maintained and operated at all times so that there
is no discharge to surface waters, nor any contamination of groundwaters, which will render them
unsatisfactory for normal use. In the event that the facilities fail to perform satisfactorily, including
the creation of nuisance conditions or failure of the irrigation area to adequately assimilate the
wastewater, the Permittee shall take immediate corrective actions including those actions that may be
required by the Division of Water Quality (Division), such as the construction of additional or
replacement wastewater treatment and disposal facilities.
4. The issuance of this permit shall not relieve the Permittee of the responsibility for damages to surface
or ground waters resulting from the operation of this facility.
4
5. The media of the Advantex AX20 Filter must comply with Orenco Systems, Inc, specifications. The
Engineer's Certification will serve as evidence that these specifications have been met.
A leakage test shall be performed on the septic tank and storage/pump tank(s) to insure that any
exfiltration occurs at a rate, which does not exceed twenty (20) gallons per twenty-four (24) hours per
1,000 gallons of tank capacity. The Engineer's Certification will serve as proof of compliance with
this condition.
i. If excavation into bedrock is required for the installation of the septic tank or sand filter, the pit shall
be lined with a 10-mil synthetic liner.
8. A sanitary tee and filter shall be installed on the effluent pipe of the septic tank. The Engineer's
Certification will serve as evidence that these specifications have been met.
9. The residuals generated from these treatment facilities must be disposed in accordance with General
Statute 143-215.1 and in a manner approved by the Division.
10. Diversion or bypassing of the untreated wastewater from the treatment facilities is prohibited.
11. The following buffers shall be maintained:
a. 100 feet between wetted area and any residence or places of public assembly under separate
ownership,
b. 50 feet between wetted area and property lines,
c. 100 feet between wetted area and wells,
d. 50 feet between wetted area and drainage ways or surface water bodies,
e. 50 feet between wetted area and public right of ways,
f. 100 feet between treatment/storage units and any wells,
g. 50 feet between treatment units and property lines, and
h. 15 feet between wetted area and any swimming pools.
Some of the buffers specified above may not have been included in previous permits for this waste
treatment and disposal system. These buffers are not intended to prohibit or prevent modifications,
which arc required by the Division, to improve performance of the existing treatment facility. These
buffers do, however, apply to modifications of the treatment and disposal facilities that are for the
purpose of increasing the flow that is tributary to the facility. These buffers do apply to any
expansion or modification of the surface irrigation areas and apply in instances in which the sale of
property would cause any of the buffers now complied with, for the treatment and disposal facilities,
to be violated. The applicant is advised that any modifications to the existing facilities will require a
permit modification.
12. The pump tank(s) shall have functional audible and visual high water alarms that are external to any
structure.
WQ0020822 Page 2
13. The disposal system shall be connected to a rain or moisture sensor that shall indicate'when
wastewater application is not appropriate in accordance with Condition II, 4.
II. OPERATION AND MAINTENANCE REQUIREMENTS
The facilities shall be properly maintained and operated at all times.
Upon classification of the wastewater treatment and surface irrigation facilities by the Water Pollution
Control System Operators Certification Commission (WPCSOCC), the Permittee shall designate and
employ a certified operator to be in responsible charge (ORC) and one or more certified operator(s) to
be back-up ORC(s) of the facilities in accordance with 15A NCAC 8G .6201. The ORC shall visit
the facilities in accordance with 15A NCAC 8G .0204 or as specified in this permit and shall comply
with all other conditions specified in these rules.
A suitable year round vegetative cover shall be maintained.
4. Irrigation shall not be performed during inclement weather or when the ground is in a condition that
will cause runoff.
Adequate measures shall be taken to prevent wastewater runoff from the irrigation field.
The application rate shall not exceed a cumulative loading of 26.2 inches over any twelve (12) month
period at an instantaneous application rate not to exceed 0.49 inches per hour.
The facilities shall be effectively maintained and operated as a non -discharge system to prevent the
discharge of any wastewater resulting from the operation of this facility.
S. No type of wastewater other than that from Keith and Patricia Bridges residence (40 Perfect Moment
Drive) shall be emitted onto the irrigation area.
No traffic or equipment shall be allowed on the disposal area except while installation occurs or while
normal maintenance is being performed.
10. The irrigation field shall be fenced with at least a two -strand wire fence.
11. Wastewater treatment units open to the atmosphere shall have restricted access and pump control
panels shall be locked.
12. The Permittee is responsible for the operation and maintenance of the entire treatment and disposal
system including, but not limited to, the following items:
a. The septic tank shall be checked annually and pumped out as needed. The septic tank effluent
filter shall be checked and cleaned at the same frequency of the septic tank.
b. The ultraviolet disinfection unit shall be checked every week. The lamp shall be cleaned and/or
replaced as necessary to ensure proper disinfection.
c. The storage, pump, and alarm systems shall be inspected monthly. The scum layer shall be
removed at the same interval as the septic tank is cleaned out.
d. The system shall be inspected monthly to make certain of the proper operation of the drip line,
that the vet),,etative growth allows a proper drip pattern, that the soil is assimilating the disposed
treated wastewater with no surface runoff, and that no objectionable odors are being generated.
WQ0020922 Page 3
` III: MONITORING AND REPORTING REOUZREMENTS
l . Any monitoring deemed necessary by the Division to insure surface and ground water protection will
be established and an acceptable sampling reporting schedule shall be followed.
2. The Permittee shall maintain records of all maintenance performed on the system and irrigation area,
as required in Condition 11, 12 for a minimum of five years. This information shall be provided to the
Division upon request.
3. Noncompliance Notification:
The Permittee shall report by telephone to the Raleigh Regional Office, telephone number (919) 791-
4200, as soon as possible, but in no case more than 24 hours or on the next working day following the
occurrence or first knowledge of the occurrence of any of the following:
a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of
adequate wastewater treatment, such as mechanical or electrical failures of pumps, emitters, etc.;
or
b. Any failure of a pumping station or treatment facility resulting in a by-pass directly to receiving
waters without treatment of all or any portion of the influent to such station or facility.
Occurrences outside normal business hours may also be reported to the Division's Emergency
Response personnel at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting such
occurrences by telephone shall also file a written report in letterform within five (5) days following
first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken
to ensure that the problem does not recur.
IV. INSPECTIONS
Adequate inspection, maintenance, and cleaning shall be provided by the Permittee to insure proper
operation of the subject facilities.
Any duly authorized officer, employee, or representative of the Division may, upon presentation of
credentials, enter and inspect any property, premises or place on or related to the disposal site or
facility at any reasonable time for the purpose of determining compliance with this permit, may
inspect or copy any records that must be maintained under the terms and conditions of this permit,
and may obtain samples of groundwater, surface water, or leachate.
V. GENERAL CONDITIONS
1. This permit shall become void unless the facilities are constructed in accordance with the conditions
of this permit, the approved plans and specifications, and other supporting data.
This permit is effective only with respect to the nature and volume of wastes described in the
application and other supporting data.
3. This permit is not transferable. In the event there is a desire for the facilities to change ownership, or
there is a name change of the Permittee, a formal permit request must be submitted to the Division
accompanied by documentation from the parties involved, and other supporting materials as may be
appropriate. The approval of this request will be considered on its merits and may or may not be
approved.
Upon the availability of a municipal or regional sewerage collection system, the subject wastewater
treatment facilities shall be abandoned and all wastewater discharged into the municipal or regional
sewerage system.
WQ0020822 Page 4
5. Failure to abide by the conditions and limitations contained in this permit may subject the Permuttee
to an enforcement action by the Division in accordance with North Carolina General Statute 143-
215.6A to 143-215.6C.
The issuance of this permit does not preclude the Permittee from complying with any and all statutes,
rules, regulations, or ordinances, which may be imposed by other government agencies (local, state,
and federal), which have jurisdiction.
7. This permit may be revoked if the Permittee fails to abide by the conditions of the "Operation and
Maintenance Agreement" previously signed by the Permittee.
I
S. The Permittee shall retain a set of approved plans, specifications, and the operation and maintenance
manual for the subject facility for the life of the project.
9. The Permittee shall pay the annual administering and compliance fee within 30 days of being billed
by the Division. Failure to pay the fee accordingly may cause the Division to initiate action to revoke
this permit as specified by 15A NCAC 2T .0105(e)(2).
10. The Permittee, at least six (6) months prior to the expiration of this permit, shall request its extension.
Upon receipt of the request, the Commission will review the adequacy of the facilities described
therein, and if warranted, will extend. the Permit for such period of time and under such conditions
and limitations, as it may deem appropriate.
Permit issued this the 13f' day of December 2008
NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION
0.&\C 1) uia-zu=
Coleen H. Sullins, Director
Division of Water Quality
By Authority of the Environmental Management Commission
Permit Number WQ0020822
WQ0020822 Page 5
Permit No. WQ0020822
December I3, 2008
ENGINEER'S CERTIFICATION
Partial Final
1, , as a duly registered Professional Engineer in the State of North
Carolina, having been authorized to observe (periodically, weekly, full time) the construction of the project,
Project Name
.location and County
for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the
construction such that the construction was observed to be built within substantial compliance and intent of this permit,
the approved plans and specifications, and other supporting materials.
Signature
Date
Registration No.
WQ0020822
Page 6
OPERATION AND M41N 7ENANCE AGREEMENT
SINGLE FAMILY RESIDENCE SURFACE IRRIGATION SYSTW 2 0 2OOu
DIVISION OF WATER QUALITY
Property Owner(s) (as appearing an the property deed); L
Mailing Address:
C
Facility Address (if different than above): LZ-1—
Disposal Method:iLl
o SPRAY IRRIGATION DRIP IRRIGATION
County, X .�— Permit No.
I/Vif a agree to operate and maintain the wastewater treatment system as follows:
fq C
(Check One)
11tifQ,�o6Z �!2z,
1, The Permittee is responsible for the operation and maintenance of the entire treatment and disposal
system including, but not limited to; the following items:
a, The septic tank shall be checked annually and pumped out as needed. The effluent filter shall be
checked and cleaned at the same frequency of the septic tank.
b. The sand filter surface shall be raked and leveled every six (6) months and any vegetative growth
shall be removed by hand [accessible sand f hers only].
c. Check one:
o The tablet chlorinator shall be checked every week. Tablets shall be added so as to provide
proper chlorination.
o' The ultraviolet disinfection unit shall be checked every week, The lamp shall be cleaned
and/or replaced to ensure proper disinfection.
d. The storage, pump, and alarm systems shall be inspected monthly. The scum layer shall be
removed at the same time interval as the septic tank is pumped out.
e, The irrigation system shall be inspected monthly to make certain of proper operation, that
vegetative growth does not interfere with the system inspection or operation, that the soil is
assimilating the disposed treated wastewater with no surface runoff, and that no objectionable
odors are being generated..
2. Failure of the Permittee to properly operate this system is subject to a penalty up to S25,000 per day.
3. Failure to meet the permit conditions or violation of the State's surface or groundwater regulations
will require evacuating the dwelling and may void the permit.
NOTE -All persons (owners) appearing on the legally registered property deed must sign this 0&M
Agreement
IIWe understand the al
Owner(s) Signature(s)
Owner(s) Signature(s)
as part of the issued permit.
Date: ��) ��A>
Date: