HomeMy WebLinkAboutWQ0019095_Final Permit_20150213'�J'A*
1
WDENR
North Carolina Department of Environment and Natural Resources
Pat McCrory
Governor
February 13, 2015
Jackie Landreth
Colfax Furniture of Greensboro, Inc.
2361 Campground Road
Greensboro, North Carolina 27406
Dear Jackie Landreth:
Donald R. van der Vaart
Subject: Permit No. WQ0019095
Colfax Furniture
Wastewater Irrigation System
Guilford County
Secretary
In accordance with your permit renewal request received November 3, 2014, we are forwarding
herewith Permit No. WQ0019095 dated February 13, 2015, to Colfax Furniture of Greensboro, Inc. for
the continued operation of the subject wastewater treatment and irrigation facilities. Please note that this
renewed permit shall become effective on May 1, 2015 (i.e. the day after the expiration date of the
existing permit).
This permit shall be effective from May 1, 2015 until April 30, 2020, shall void Permit No.
WQ0019095 issued May 30, 2006, and shall be subject to the conditions and limitations as specified
therein. Please pay particular attention to the monitoring requirements listed in Attachments A and B for
they may differ from the previous permit issuance. Failure to establish an adequate system for collecting
and maintaining the required operational information shall result in future compliance problems.
Please note that per the Division of Water Resources' Non -Discharge Permitting Unit Wastewater
Monitoring Policy, all non -discharge systems are having their effluent monitoring schedules reevaluated
based on the type of system as well as the flow in gallons per day. In addition, monitoring requirements
have been added for Total Nitrogen (00600) and Total Residual Chlorine (50060). The sampling points
PPI 001 and PPI 002 from your previous permit have been combined into one sampling point PP1 001.
For your convenience, customized electronic copies of your facility's NDMR and NDAR-1
reporting forms are available for download at: hqp://portal.ncdenr.or web/wq/aps/lau/reporting.
If any parts, requirements or limitations contained in this permit are unacceptable, the Permittee
has the right to request an adjudicatory hearing upon written request within 30 days following receipt of
this permit. This request shall be in the form of a written petition, conforming to Chapter 150B of the
North Carolina General Statutes, and filed with the Office of Administrative Hearings at 6714 Mail
Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and
binding.
Non -Discharge Permitting Unit
1617 Mail Service Center, Raleigh, North Carolina 27699-1617
Phone: 919-807-64641 Internet: httn:!/mortal.ncdenr.org/weblwa
An Equat Opportunity 1 Affirmative Action Employer - Made in part with recycled paper
Jackie Landreth
February 13, 2015
Page 2 of 2
If you need additional information concerning this permit, please contact Alice M. Wessner at
(919) 807-6425 or alice.wessner@ncdenr.gov.
Sincerely,
. Ja immerman, Acting Director
Division of Water Resources
cc: Guilford County Health Department Health Director, Merle Green: mgreen co.guilford.nc.us
(Electronic Copy)
Winston Salem Regional Office, Water Quality Regional Operations Section (Electronic Copy)
Central Files
Digital Permit Archive (Electronic Copy)
NORTH CAROLINA
ENVIRONMENTAL MANAGEMENT COMMISSION
DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES
RALEIGH
WASTEWATER IRRIGATION SYSTEM PERMIT
In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as
amended, and other applicable Laws, Rules and Regulations
PERMISSION IS HEREBY GRANTED TO
Colfax Furniture of Greensboro, Inc.
Guilford County
FOR THE
continued operation of a 628 gallon per day (GPD) wastewater treatment and irrigation facility consisting
of:
a 13,450 gallon storage tank with a audible and visual alarm, a two 1,000 gallon septic tanks (previously
permitted by Guilford County Health Department, permit number 017952), two seven feet by thirteen
feet above ground recirculation sand filter, tablet chlorinator unit, % hp pump, hydraulic control unit with
a audible and visual alarm, influent and effluent flow meters, three drip zones at 1,347 linear feet per
zone with a rain and moisture sensor, 17,200 square feet wetted area and all associated appurtenances to
serve Colfax Furniture of Greensboro, Inc., with no discharge of wastes to the surface waters, pursuant to
the application received November 3, 2014, by the Division, and in conformity with the project plan,
specifications, and other supporting data subsequently filed and approved by the Department of
Environment and Natural Resources and considered a part of this permit.
This permit shall be effective from May 1, 2015 until April 30, 2020, shall void Permit No. WQ0019095
issued May 30, 2006, and shall be subject to the following specified conditions and limitations:
I. SCHEDULES
1. No later than six months prior to the expiration of this permit, the Penmittee shall request renewal of
this permit on official Division forms. Upon receipt of the request, the Division will review the
adequacy of the facilities described therein, and if warranted, will renew the permit for such period of
time and under such conditions and limitations as it may deem appropriate. Please note Rule 15A
NCAC 02T .0105(d) requires an updated site map to be submitted with the permit renewal
application.
WQ9019095 Version 3.0 Shell Version 150101 Page I of 8
H. PERFORMANCE STANDARDS
The subject non -discharge facilities shall be effectively maintained and operated at all times so there
is no discharge to surface waters, nor any contravention of groundwater or surface water standards.
In the event the facilities fail to perform satisfactorily, including the creation of nuisance conditions
due to improper operation and maintenance, or failure of the irrigation areas to adequately assimilate
the effluent, the Permittee shall take immediate corrective actions including Division required actions,
such as the construction of additional or replacement wastewater treatment or irrigation facilities.
[G.S. 143-215.1, 143-213.3(a)]
2. This permit shall not relieve the Permittee of their responsibility for damages to groundwater or
surface water resulting from the operation of this facility. [15A NCAC 02B .0200, 02L .0100]
3. Effluent quality shall not exceed the limitations specified in Attachment A. [15A NCAC 02T
.0108(b)(1)]
4. Application rates, whether hydraulic, nutrient or other pollutant, shall not exceed those specified in
Attachment B. [15A NCAC 02T .0505(c), 02T .0505(n)]
5. This disposal system was individually permitted on or after December 30, 1983; therefore, the
compliance boundary is established at either 250 feet from the effluent disposal area, or 50 feet within
the property boundary, whichever is closest to the effluent disposal area. An exceedance of
groundwater standards at or beyond the compliance boundary is subject to remediation action
according to 15A NCAC 02L .0106(d)(2) as well as enforcement actions in accordance with North
Carolina General Statute 143-215.6A through 143-215.6C. [15A NCAC 02L .0106(dx2), 02L
.0107(b)]
6. In accordance with 15A NCAC 02L .0108, the review boundary is established midway between the
compliance boundary and the effluent disposal area. Any exceedance of groundwater standards at the
review boundary shall require action in accordance with 15A NCAC 02L .0106. [15A NCAC 02L
.0106, 02L .0108]
7. The Permittee shall apply for a permit modification to establish a new compliance boundary prior to
any sale or transfer of property affecting a compliance boundary. [15A NCAC 02L .0107(c)]
8. In accordance with 15A NCAC 02L .0107(d), no wells, excluding Division approved monitoring
wells, shall be constructed within the compliance boundary except as provided for in 15A NCAC 02L
.0107(g). [15A NCAC 02L .0107]
9. Except as provided for in 15A NCAC 02L .0107(g), the Permittee shall ensure any landowner who is
not the Permittee and owns land within the compliance boundary shall execute and file with the
Guilford County Register of Deeds an easement running with the land containing the following items:
a. A notice of the permit and number or other description as allowed in 15A NCAC 02L .0107(f)(1);
b. Prohibits construction and operation of water supply wells within the compliance boundary; and
c. Reserves the right of the Permittee or the State to enter the property within the compliance
boundary for purposes related to the permit.
The Director may terminate the easement when its purpose has been fulfilled or is no longer needed.
[15A NCAC 02L .0107(f)]
10. The sand media of the dual bed pressure dosed surface sand filter must comply with the Division's
sand specifications. The Engineer's Certification will serve as evidence that these specifications have
been met.
11. The disposal system shall be connected to a rain or moisture sensor that shall indicate when
wastewater application is not appropriate.
WQ0019095 Version 3.0 Shell Version 150101 Page 2 of 8
12. The facilities permitted herein shall be constructed according to the following setbacks:
a. The setbacks for irrigation sites permitted under 15A NCAC 02H .0200 shall be as follows (all
distances in feet):
i. Any habitable residence or place of public assembly under separate ownership: 100
ii. Surface waters: 50
iii. Any well with exception of monitoring wells: 100
iv. Any property. line: 50
v. Public right of way: 50
[15A NCAC 02H .02190)]
b. The setbacks for storage and treatment units permitted under 15A NCAC 02H . shall be as
follows (all distances in feet):
i. Any well with exception of monitoring wells: 100
ii. Any property line: 50
[15A NCAC 02H .02190)]
M. OPERATION AND MAINTENANCE REQUIREMENTS
1. The facilities shall be properly maintained and operated at all times. The facilities shall be effectively
maintained and operated as a non -discharge system to prevent the discharge of any wastewater
resulting from the operation of this facility. The Permittee shall maintain an Operation and
Maintenance Plan, which at a minimum shall include operational functions, maintenance schedules,
safety measures and a spill response plan. [15A NCAC 02T .0507]
2. Upon the Water Pollution Control System Operators Certification Commission's (WPCSOCC)
classification of the subject non -discharge facilities, in accordance with 15A NCAC 08G .0200 the
Permittee shall designate and employ a certified operator in responsible charge (ORC) and one or
more certified operator(s) as back-up ORC(s). The ORC or their back-up shall visit the facilities in
accordance with 15A NCAC 08G .0200, and shall comply with all other conditions specified in the
previously cited rules. [ 15A NCAC 02T .0117]
3. A suitable year round vegetative cover shall be maintained at all times, such that crop health is
optimized, allows for even distribution of effluent and allows inspection of the irrigation system.
[15A NCAC 02T .0108(b)(1)]
4. Adequate measures shall be taken to prevent effluent ponding in or runoff from the irrigation sites
listed in Attachment B. [15A NCAC 02T .0108(b)(1)]
5. Irrigation shall not be performed during inclement weather or when the ground is in a condition that
will cause ponding or runoff. [ 15A NCAC 02T .0108(b)(1)]
6. All irrigation equipment shall be tested and calibrated at least once per permit cycle. Calibration
records shall be maintained at the facility for a period of no less than five years, and shall be made
available to the Division upon request. [ 15A NCAC 02T .0108(b)(1)]
7. Only effluent from Colfax Furniture shall be irrigated on the sites listed in Attachment B. [G.S. 143-
215.1]
8. No automobiles or machinery shall be allowed on the irrigation sites except during equipment
installation or while maintenance is being performed. [15A NCAC 02T .0108(bxl)]
WQ0019095 Version 3.0 Shell Version 150101 Page 3 of 8
9. Public access to the irrigation sites and wastewater treatment facilities shall be prohibited. [15A
NCAC 02T .0505(q)
10. The residuals generated from the wastewater treatment facilities shall be disposed or utilized in
accordance with 15A NCAC 02T .1100. The Permittee shall maintain a residual management plan
pursuant to 15A NCAC 02T .0508 [15A NCAC 02T .0508, 02T .1100]
11. Diversion or bypassing of untreated or partially treated wastewater from the treatment facilities is
prohibited. [15A NCAC 02T .05050)]
12. A protective vegetative cover shall be established and maintained on all earthen embankments (i.e.,
outside toe of embankment to maximum allowable temporary storage elevation on the inside of the
embankment), berms, pipe runs, erosion control areas, and surface water diversions. Trees, shrubs,
and other woody vegetation shall not be allowed to grow on the earthen dikes or embankments.
Earthen embankment areas shall be kept mowed or otherwise controlled and accessible. [ 15A NCAC
02T .0108(b)(1)]
IV. MONITORING AND REPORTING REQUIREMENTS
1. Any Division required monitoring (including groundwater, plant tissue, soil and surface water
analyses) necessary to ensure groundwater and surface water protection shall be established, and an
acceptable sampling reporting schedule shall be followed. [ 15A NCAC 02T .0108(c)]
2. A Division certified laboratory shall conduct all laboratory analyses for the required effluent,
groundwater or surface water parameters. [15A NCAC 02H .0800]
3. Flow through the treatment facility shall be continuously monitored, and daily average flow values
shall be reported on Form NDMR. Flow may be estimated from water use records, provided the
Permittee's water use is metered. Daily average flow values shall be calculated by dividing the
monthly metered water usage by the number of days in the month. [15A NCAC 02T .0105(k), 02T
.0108(c)]
4. The Permittee shall monitor the effluent from the subject facilities at the frequencies and locations for
the parameters specified in Attachment A. [ 15A NCAC 02T .0108(c)]
The Permittee shall maintain adequate records tracking the amount of effluent irrigated. At a
minimum, these records shall include the following information for each irrigation site listed in
Attachment B:
a. Date of irrigation;
b. Volume of effluent irrigated;
c. Site irrigated;
d. Length of time site is irrigated;
e. Continuous weekly, monthly, and year-to-date hydraulic (inches/acre) loadings;
f. Continuous monthly and year-to-date loadings for any non -hydraulic parameter specifically
limited in Attachment B;
g. Weather conditions; and
h. Maintenance of cover crops.
[15A NCAC 02T .0108(c)]
6. Three copies of all monitoring data (as specified in Conditions IV.3. and IVA.) on Form NDMR for
each PPI and three copies of all operation and disposal records (as specified in Conditions IV.5.) on
Form NDAR-1 for every -site in Attachment B shall be submitted on or before the last day of the
following month. If no activities occurred during the monitoring month, monitoring reports are still
required documenting the absence of the activity. All information shall be submitted to the following
address:
WQ0019095 Version 3.0 Shell Version 150101 Page 4 of 8
Division of Water Resources
Information Processing Unit
1617 Mail Service Center
Raleigh, North Carolina 27699-1617
[15A NCAC 02T .0105(1)]
7. A record shall be maintained of all residuals removed from this facility. This record shall be
maintained at the facility for a period of no less than five years, and shall be made available to the
Division upon request. At a minimum, this record shall include:
a. Name of the residuals hauler;
b. Non -Discharge permit number authorizing the residuals disposal, or a letter from a municipality
agreeing to accept the residuals;
c. Date the residuals were hauled; and
d. Volume of residuals removed.
[I 5A NCAC 02T .0108(b)(1)]
A maintenance log shall be maintained at this facility. This log shall be maintained at the facility for
a period of no less than five years, and shall be made available to the Division upon request. At a
minimum, this log shall include:
a. Visual observations of the plant and plant site; and
b. Record of preventative maintenance (e.g., changing of equipment, adjustments, testing,
inspections and cleanings, etc.).
[I 5A NCAC 02T .0108(b)(1)]
9. An annual representative soils analysis (i.e., Standard Soil Fertility Analysis) shall be conducted on
each irrigation site listed in Attachment B. These results shall be maintained at the facility for a
period of no less than five years, and shall be made available to the Division upon request. At a
minimum, the Standard Soil Fertility Analysis shall include the following parameters:
Acidity
Exchangeable Sodium Percentage
Phosphorus
Base Saturation (by calculation)
Magnesium
Potassium
Calcium
Manganese
Sodium
Cation Exchange Capacity
Percent Humic Matter
Zinc
Copper
pH
[15A NCAC 02T .0108(c)]
10. Noncompliance Notification:
The Permittee shall report by telephone to the Winston Salem Regional Office, telephone number
(336) 776-9800, as soon as possible, but in no case more than 24 hours, or on the next working day
fbllowing the occurrence or first knowledge of the occurrence of any of the following:
a. Treatment of wastes abnormal in quantity or characteristic, including the known passage of a
hazardous substance.
b. Any process unit failure (e.g., mechanical, electrical, etc.), due to known or unknown reasons,
rendering the facility incapable of adequate wastewater treatment.
c. Any facility failure resulting in a by-pass directly to receiving surface waters.
d. Any time self -monitoring indicates the facility has gone out of compliance with its permit
limitations.
e. Ponding in or runoff from the irrigation sites.
WQ0019095 Version 3.0 Shell Version 150101 Page 5 of 8
V.
Any emergency requiring immediate reporting (e.g., discharges to surface waters, imminent failure of
a storage structure, etc.) outside normal business hours shall be reported to the Division's Emergency
Response personnel at telephone number (800) 662-7956, (800) 858-0368, or (919) 733-3300.
Persons reporting such occurrences by telephone shall also file a written report in letter form within
five days following first knowledge of the occurrence. This report shall outline the actions taken or
proposed to be taken to ensure the problem does not recur. [15A NCAC 02T .0105(1), 02T
.0108(b)(1)]
1. The Permittee shall provide adequate inspection and maintenance to ensure proper operation of the
wastewater treatment and irrigation facilities. [15A NCAC 02T .0108(b)]
2. The Permittee or their designee shall inspect the wastewater treatment and irrigation facilities to
prevent malfunctions, facility deterioration and operator errors resulting in discharges, which may
cause the release of wastes to the environment, a threat to human health or a public nuisance. The
Permittee shall maintain an inspection log that includes, at a minimum, the date and time of
inspection, observations made, and any maintenance, repairs, or corrective actions taken. The
Permittee shall maintain this inspection log for a period of five years from the date of the inspection,
and this log shall be made available to the Division upon request. [15A NCAC 02T .0108(b)]
3. Any duly authorized Division representative may, upon presentation of credentials, enter and inspect
any property, premises or place on or related to the wastewater treatment and irrigation facilities
permitted herein at any reasonable time for the purpose of determining compliance with this permit;
may inspect or copy any records required to be maintained under the terms and conditions of this
permit, and may collect groundwater, surface water or leachate samples. [G.S. 143-21.5.3(a)(2)]
VI. GENERAL CONDITIONS
1. Failure to comply with the conditions and limitations contained herein may subject the Permittee to
an enforcement action by the Division in accordance with North Carolina General Statutes 143-
215.6A to 143-215.6C. [G.S. 143-215.6A to 143-215.6C]
2. This permit shall become voidable if the permitted facilities are not constructed in accordance with
the conditions of this permit, the Division approved plans and specifications, and other supporting
documentation. [15A NCAC 02T .0110]
3. This permit is effective only with respect to the nature and volume of wastes described in the permit
application, Division approved plans and specifications, and other supporting documentation. No
variances to applicable rules governing the construction or operation of the permitted facilities are
granted, unless specifically requested and approved in this permit pursuant to 15A NCAC 02T
.0105(n). [G.S. 143-21.5.1]
4. The issuance of this permit does not exempt the Permittee from complying with any and all statutes,
rules, regulations, or ordinances, which may be imposed by other jurisdictional government agencies
(e.g., local, state, and federal). Of particular concern to the Division are applicable river buffer rules
in 15A NCAC 02B .0200; erosion and sedimentation control requirements in 15A NCAC Chapter 4
and under General Permit NCG010000; any requirements pertaining to wetlands under 15A NCAC
02B .0200 and 02H .0500; and documentation of compliance with Article 21 Part 6 of Chapter 143 of
the General Statutes. [15A NCAC 02T .0105(c)(6)]
9VQ0019095 Version 3.0 Shell Version 150101 Page 6 of 8
In the event the permitted facilities change ownership or the Permittee changes their name, a formal
permit modification request shall be submitted to the Division. This request shall be made on official
Division forms, and shall include appropriate property ownership documentation and other supporting
documentation as necessary. The Permittee of record shall remain fully responsible for maintaining
and operating the facilities permitted herein until a permit is issued to the new owner. [15A NCAC
02T .0104]
6. The Permittee shall retain a set of Division approved plans and specifications for the life of the
facilities permitted herein. [15A NCAC 02T .0108(b)(1)]
The Permittee shall maintain this permit until all permitted facilities herein are properly closed or
permitted under another permit issued by the appropriate permitting authority. [15A NCAC 02T
.01050)]
8. This permit is subject to revocation or unilateral modification upon 60 days notice from the Division
Director, in whole or part for the requirements listed in 15A NCAC 02T .0110. [15A NCAC 02T
.0110]
9. Unless the Division Director grants a variance, expansion of the permitted facilities contained herein
shall not be granted if the Permittee exemplifies any of the criteria in 15A NCAC 02T .0120(b). [15A
NCAC 02T .0120]
10. The Permittee shall pay the annual fee within 30 days after being billed by the Division. Failure to
pay the annual fee accordingly shall be cause for the Division to revoke this permit. [ 15A NCAC 02T
.0105(e)(3)]
Permit issued this the 13'h day of February 2015
NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION
. Jay ZKrmerman, Acting Director
Division of Water Resources
By Authority of the Environmental Management Commission
Permit Number WQ0019095
WQ0019095 Version 3.0 Shell Version 150101 Page 7 of 8
WQ0019095 Version 3.0 Shell Version 150101 Page 8 of 8
ATTACHMENT A — LIIVIITATIONS AND MONITORING REQUIREMENTS
PPI 001— WWTF Effluent
Permit Number: WQ0019095 Version: 3.0
EFFLUENT CHARACTERISTICS
EFFLUENT LIMITS
MONITORING REQUIREMENTS
PCS
Cocle
Parameter Description
Units of
Measure
Monthly
Average
Monthly
Geometric Mean
Daily Minimum
Daily Maximum
Measurement
Frequency
Sample
Type
51050
Flow, in Conduit or thru Treatment Plant
GPD
628
Monthly
Estimated
00310
BOD, 5-Day (20 °C)
mg/L
Annually
Grab
31616
Coliform, Fecal MF, M-FC Broth, 44.5 °C
#/100 mL
Annually
Grab
j00610
Nitrogen, Ammonia Total (as N)
mg/L
Annually
Grab
00625
Nitrogen, Kjeldahl, Total (as N)
mg/L
Annually
Grab
00620
Nitrogen, Nitrate Total (as N)
mg/L
Annually
Grab
00600
Nitrogen, Total (as N)
mg/L
Annually
Grab
00400
pH
su
Once per Event'
Grab
50060
Chlorine, Total Residual
mg/L
Once per Event'
Grab
00665
Phosphorus, Total (as P)
mg/L
Annually
Grab
00530
Solids, Total Suspended
mg/L
Annually
Grab
1. Total Residual Chlorine and pH can be "Per Event' if Permittee documents that the facility irrigates at a rate less than once a week.
WQ0019095 Version 3.0 Attachment A Page 1 of 1
THIS PAGE BLANK
ATTACHMENT B - APPROVED LAND APPLICATION SITES AND LIMITATIONS
Colfax Furniture of Greensboro
Permit Number: WQ0019095 Version: 3.0
IRRIGATION AREA INFORMATION
APPLICATION LIMITATIONS
Field
Owner
County
Latitude
Longitude
Net
Acreage
Dominant
Soil Series
Parameter
Hourly
Rate
Yearly
Max
Units
I
Colfax Furniture of Greensboro
Guilford
36.00.29
79.50.27
0.13
01284 — Non Discharge Application
0.3
26
inches
2
Colfax Furniture of Greensboro
Guilford
36.00.28
79.50.26
0.13
01284 — Non Discharge Application
0.3
26
inches
3
Colfax Furniture of Greensboro
Guilford
36.00.29
79.50.26
0.13
01284 — Non Discharge Application
0.3
26
inches
Totals
0.39
WQ0019095 Version 3.0 Attachment B Page 1 of 1
THIS PAGE BLANK
FORM: NDMR 03-12
NON -DISCHARGE MONITORING REPORT (NDMR)
Permit No.: WQ0019095
Facility Name: Colfax Furniture
County: Guilford
Month:
Year:
PPI: 001
Flow Measuring Point: ❑ Influent ❑� Effluent ❑ No flow generated
Parameter Monitoring Point: ❑ Influent Effluent ❑ Groundwater Lowering ❑ Surface Water
Parameter Code —.
600$,0
00310
31616
00610
00625
00620
00600
00400
00665 1
00530
50060
❑
}4 N
o
c
O
C
UN
-
o
y
O
co
o
i v
2
E
a
s
idvCD
C�
0
z
o
y'0
z
o
z
°
N
o °
F8F�
'ateC (On
0
�
w 'C
NM
XLOL)
24-hr
hrs
GP0
mg/L
#/100 mL
mg/L
mg/L
mg/L
mg/L
su
mg/L
mg/L
mg/L
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
Average:
Daily Maximum:
Daily Minimum:
Sampling Type:
Estimate
Grab
Grab
Grab
Grab
Grab
Grab
Grab
Grab
Grab
Grab
Monthly Avg. Limit:
628
Daily Limit:
[Annually
Sample Frequency:
Monthly
Annually
Annually
Annually
Annually
Annually
Annually
Per Event
Annually
Per Event
FORM: NDAR-1 10-13 NON -DISCHARGE APPLICATION REPORT (NDAR-1) Page
' Q11 •1•Colfax•
•
1irrigationoccur
at this facility?
El YES ■ •
• Rate
1
• '.
1
• '.
Annual Rate (in):
Annual Rate (in):
Annual Rate (in):
Annual Rate (in):
Field Irrigated?
Field Irrigated?
�E��
Field Irrigated?
Field Irrigated?
®___
_Monthly
_
Loading:
• n t h F I •. t i n • T •
j//////,
V/////-////////.://///////,j//////.-
./
/
/