HomeMy WebLinkAboutWQ0015491_Final Permit_200805290WA Michael F. Easley, Governor
William G. Ross Jr., Secretary
North Carolina Department of Environment and Natural Resources
3 12: --i
Q Coleen H. Sullins, Director
May 29, 2008
RUSSFLL H. HACKETT
2518 RACE TRACK ROAD
SOPHIA, NORTH CAROLINA 27350
Dear Mr. Hackett:
Division of Water Quality
Subject: Permit No. WQ0015491
Caraway Speedway
Wastewater Surface Irrigation
Randolph County
In accordance with your permit renewal request received December 27, 2007, and modification
received May 29, 2008, we are forwarding herewith Permit No. WQ0015491, dated May 29, 2008, to
Caraway Speedway for the continued operation of the subject wastewater treatment and surface irrigation
facilities. This modification includes a flow reduction to 9,999 gallons per day.
This permit shall be effective from the date of issuance until April 30, 2013, shall void Permit No.
WQ001549J issued August 22, 2003, and shall be subject to the conditions and limitations as specified
therein. Please pay particular attention to the monitoring requirements in this permit. Failure to establish
an adequate system, for collecting and maintaining the required operational information will result in
future compliance problems. Please note that effluent sampling parameters and frequencies have been
changed (Attachment A).
If any parts, requirements, or limitations contained in this permit are unacceptable, you have the
right to request an adjudicatory hearing upon written request within thirty (30) days following receipt of
this permit. This request must be in the form of a written petitiori, conforming to Chapter 150B of the
North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service
Center, Raleigh, NC 27699-6714. Unless such demands are made this permit shall be final and binding.
If you need additional information concerning this matter, please contact Matthew Fleahman at
(919) 715-6173 or matthew,fleahman@ncmail.net.
Sincerely
'(Coleen H. Sullins
cc: Randolph County Health Department
Winston-Salem Regional Office, Aquifer Protection Section
Technical Assistance and Certification Unit (with rating sheet attached)
APS Central Files
LAU Files
Na thCa7oliria
Naturally
Aquifer Protection Section 1636 Mail Service Center Raleigh, NC 27699-1636 Telephone : (919) 733-3221
Internet: www newaterguality.ore Location: 2728 Capital Boulevard Raleigh, NC 27604 Fax 1: (919) 715-0588
Fax 2: (919) 715-6048
An Equal Opportunity/Affirmative Action Employer— 500/6 Recycled/10% Post Consumer Paper Customer Service: (877) 623-6748
rE -
t`'
NORTH CAROLINA
ENVIRONMENTAL MANAGEMENT COMMISSION
DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES
RALEIGH
SURFACE IRRIGATION SYSTEM PERMIT
In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as
amended, and other applicable Laws, Rules, and Regulations
PERMISSION IS HEREBY GRANTED TO
Caraway Speedway
Randolph County
FOR THE
continued operation of a 9,999-GPD surface drip irrigation treatment and disposal facility consisting of an
8,000-gallon two chambered septic tank, a 10,000-gallon recirculation chamber, two 12,000-gallon
concrete tanks, two 56-foot by 18-foot recirculating sand filters (3:1), a tablet chlorinator, Perc-Rite
controls and pumps with audible and visual high water alarms, four irrigate on fields on approximately
196 acres, 19,100 feet of dripper line, 9,550 emitters, with a flow of 71 GPM to serve the Caraway
Speedway, with no discharge of wastes to the surface waters, pursuant to the application received
December 27, 2007, and subsequent additional information received by the Division of Water Quality
(Division), and in conformity with the project plan, specifications, and other supporting data subsequently
fled and approved by the Department of Environment and Natural Resources and considered a part of
this permit.
This permit shall be effective from the date of issuance until April 30, 2013, shall void Permit No.
WQ0015491 issued August 22, 2003, and shall be subject to the following specified conditions and
limitations:
I. SCHEDULES [please review the entire permit for reporting, monitoring, and other on -going activities]
1. No later than six (6) months prior to the expiration of this permit, the Permittee shall request renewal
of this permit on official Division form(s). Upon receipt of the request, the Division will review the
adequacy of the facilities described therein, and if warranted, will extend the permit for such period of
time and under such conditions and limitations as it may deem appropriate. Please note that Rule
15A NCAC 02T .0105(d) requires an updated site map to be submitted with the permit renewal
application.
WQ0015491 Version 3.0 Shell Version 070531 Page 1 of 7
11. PERFORMANCE STANDARDS
The surface irrigation facilities shall be effectively maintained and operated at all times so that there
is no discharge to the surface waters, nor any contravention of groundwater or surface water
standards, In the event that the facilities fail to perform satisfactorily, including the creation of
nuisance conditions or failure of the irrigation area to adequately assimilate the wastewater, the
Permittee shall take immediate corrective actions including those actions that may be required by the
Division, such as the construction of additional or replacement wastewater treatment and disposal
facilities.
w
2. The issuance of this permit shall not relieve the Permittee of the responsibility for damages to ground
or surface waters resulting from the operation of this facility.
All wells that are constructed for purposes of groundwater monitoring shall be constructed in
accordance with 15A NCAC. 02C .0108 (Standards of Construction for Wells Other than Water
Supply) and any other state and local laws and regulations pertaining to well construction.
4. Effluent limitations shall not exceed those specified in Attachment A.
5. Application rate(s), whether hydraulic, nutrient, or other pollutant shall not exceed those specified in
Attachment B.
6. The compliance boundary for the disposal system is specified by rules in 15A NCAC 02L,
Groundwater Classifications and Standards. This disposal system was individually permitted on or
after December 30, 1983; therefore, the compliance boundary is established at either 250 feet from
the waste disposal area, or 50 feet within the property boundary, whichever is closest to the waste
disposal area. An exceedance of groundwater standards at or beyond the compliance boundary is
subject to remediation action according to 15A NCAC 02L .0106(d)(2) as well as enforcement
actions in accordance with North Carolina General Statute 143-215.6A through 143-215.6C.
7. The Permittee shall apply for a permit modification prior to any sale or transfer of property that
affects a compliance boundary to establish a new compliance boundary.
8. In accordance with 15A NCAC 02L .0107(d), no wells, other than monitoring wells, shall be
constructed within the compliance boundary except as provided by 15A NCAC 02L .0107(g).
9. The review boundary is established around the disposal systems midway between the compliance
boundary and the perimeter of the waste disposal area. Any exceedance of standards at the review
boundary shall require action in accordance with 15A NCAC 02L .0106.
10. The facilities permitted herein must be constructed according to the following setbacks:
a. The setbacks for Irrigation sites shall be as follows (all distances in feet):
i. Any habitable residence or place of public assembly under separate ownership
ii. Surface waters:
iii. Any well with exception of monitoring wells:
iv. Any property line:
v. Public right of way:
b. The setbacks for Treatment and storage units shall be as follows (all distances in feet):
i. Any well with exception of monitoring wells:
ii. Any property line:
100
100
100
50
50
100
50
WQ0015491 Version 3.0 Shell Version 070531 Page 2 of 7
III, OPERATION AND MAINTENANCE REOUIREMENTS
1. The facilities shall be properly maintained and operated at all times. The facilities shall be effectively
maintained and operated as a non -discharge system to prevent the discharge of any wastewater
resulting fi-om the operation of this facility. The Permittee shall maintain an Operation and
Maintenance Plan pursuant to 15A NCAC 02T .0507 including operational functions, maintenance
schedules, safety measures, and a spill response plan.
2. Upon classification of the wastewater treatment and irrigation facilities by the Water Pollution
Control System Operators Certification Commission (WPCSOCC), the Permittee shall designate and
employ a certified operator to be in responsible charge (ORC) and one or more certified operator(s) to
be back-up ORC(s) of the facilities in accordance with 15A NCAC 08G .0200. The ORC shall visit
the facilities in accordance with 15A NCAC 08G .0200 or as specified in this permit and shall comply
with all other conditions specified in these rules.
3. A suitable year round vegetative cover shall be maintained such that crop health is optimized, allows
for even distribution of effluent, and allows inspection of the irrigation system.
4. Adequate measures shall be taken to prevent wastewater ponding or runoff from the irrigation field.
5. Irrigation shall not be performed during inclement weather or when the ground is in a condition that
will cause ponding or runoff.
6. All waste application equipment must be tested and calibrated at least once per year. Records of the
calibration must be maintained for five years.
7. No type of wastewater other than that from Caraway Speedway shall be irrigated onto the irrigation
area.
8. No traffic or equipment shall be allowed on the disposal area except while installation occurs or while
normal maintenance is being performed.
9. Public access to the land application sites shall be controlled. Such controls may include the posting
of signs showing the activities being conducted at each site
10. The residuals generated from these treatment facilities must be disposed / utilized in accordance with
15A NCAC 02T .1100. The Permittee shall maintain a residual management plan pursuant to 15A
NCAC 02T .0508.
11. Diversion or bypassing of the untreated wastewater from the treatment facilities is prohibited.
IV. MONITORING AND REPORTING RE UMEMENTS
1. Any monitoring (including groundwater, surface water, soil or plant tissue analyses) deemed
necessary by the Division to ensure surface and ground water protection will be established and an
acceptable sampling reporting schedule shall be followed.
2. All laboratory analyses for effluent, ground waters, or surface waters shall be made by a laboratory
certified by the Division for the required parametcr(s) under 15A NCAC 02H .0800.
3. Flow through the treatment facility shall be continuously monitored and daily average flow values
shall be reported on Form NDMR. Flow may be estimated from water use records provided water
use is metered. Daily average values shall be calculated by dividing monthly flow volume by the
number of days in the month.
4. The effluent from the subject facilities shall be monitored by the Permittee at the frequency(ies) and
location(s) for the parameter(s) specified in Attachment A.
WQ0015491 Version 3.0 Shell Version 070531 Page 3 of 7
5. The Permittee tracking the amount of wastewater disposed shall maintain adequate records. `these
records shall include, but are not necessarily limited to, the following information:
a. Date of irrigation,
b. Volume of wastewater irrigated,
c. Field irrigated,
d. Length of time field is irrigated,
e. Continuous weekly, monthly, and year-to-date hydraulic (inches/acre) loadings for each field,
f. Continuous monthly and year-to-date loadings for any non -hydraulic parameter specifically
limited in Attachment B for each field,
g. Weather conditions, and
h. Maintenance of cover crops.
6. Three (3) copies of all monitoring data [as specified in Conditions IV. 3. and IV. 4.] on Form NDMR
for each PPI and three (3) copies of all operation and disposal records [as specified in Condition IV.
51 on Form NDAR-1 for every field shall be submitted on or before the last day of the following
month. If no activities occurred during the monitoring month, monitoring reports are still required
documenting the absence of the activity. All information shall be submitted to the following address:
Division of Water Quality
Information Processing Unit
1617 Mail Service Center
Raleigh, North Carolina 27699-1617
7. An annual representative soils analysis (Standard Soil Fertility Analysis) shall be conducted on each
irrigation field and the results maintained on file by the Permittee for a minimum of five years. The
Standard Soil Fertility Analysis shall include, but is not necessarily limited to, the following
parameters:
Acidity
Manganese
Potassium
Calcium
Percent Humic Matter
Sodium
Copper
pH
Zinc
Magnesium
Base Saturation (by calculation)
Phosphorus
Cation Exchange Capacity
Exchangeable Sodium Percentage
8. Noncompliance Notification:
The Permittee shall report by telephone to the Winston-Salem Regional Office, telephone number
(336) 771-5000, as soon as possible, but in no case more than 24 hours or on the next working day
following the occurrence or first knowledge of the occurrence of any of the following:
a. Any occurrence at the wastewater treatment facility which results in the treatment of significant
amounts of wastes which are abnormal in quantity or characteristic, such as the dumping of the
contents of a sludge digester; the known passage of a slug of hazardous substance through the
facility; or any other unusual circumstances including ponding in the irrigation field or runoff
from the irrigation fields.
b. Any process unit failure, due to known or unknown reasons, that render the facility incapable of
adequate wastewater treatment such as mechanical or electrical failures of pumps, aerators,
compressors, etc.
c. Any failure of disposal system resulting in a by-pass directly to receiving waters.
WQ0015491 Version 3.0 Shell Version 070531 Page 4 of 7
d. Any time that self -monitoring information indicates that the facility has gone out of compliance
with its permit limitations including, but not limited to, freeboard measurements, effluent
limitations, exceedances of groundwater standards, or overloading of any field.
For any emergency that requires immediate reporting (e,g., discharges to surface waters, imminent
failure of a storage structure, etc.) outside normal business hours must be reported to the Division's
Emergency Response personnel at telephone number (800) 662-7956, (800) 858-0368, or (919) 733-
3300. Persons reporting such occurrences by telephone shall also file a written report in letter form
within five (5) days following first imowiedge of the occurrence. This report must outline the actions
taken or proposed to be taken to ensure that the problem does not recur.
V. INSPECTIONS
1. Adequate inspection and maintenance shall be provided by the Permittee to ensure proper operation
of the subject facilities.
2. The Permittee or his designee shall inspect the wastewater treatment and disposal facilities to prevent
malfunctions and deterioration, operator errors and discharges which may cause or lead to the release
of wastes to the environment, a threat to human health, or a nuisance. The Permittee shall keep an
inspection log or summary including at least the date and time of inspection, observations made, and
any maintenance, repairs, or corrective actions taken by the Permittee. This log of inspections shall
be maintained by the Permittee for a period of five years from the date of the inspection and shall be
made available upon request to the Division or other permitting authority.
3. Any duly authorized officer, employee, or representative of the Division may, upon presentation of
credentials, enter and inspect any property, premises or place on or related to the disposal site or
facility at any reasonable time for the purpose of determining compliance with this permit; may
inspect or copy any records that must be maintained under the terms and conditions of this permit,
and may obtain samples of groundwater, surface water, or leachate.
VL GENERAL CONDITIONS
I. Failure to abide by the conditions and limitations contained in this permit may subject the Permittee
to an enforcement action by the Division in accordance with North Carolina General Statute 143-
215.6A to 143-215.6C.
2. This permit shall become voidable unless the facilities are constructed in accordance with the
conditions of this permit, the approved plans and specifications, and other supporting data.
3. This permit is effective only with respect to the nature and volume of wastes described in the
application and other supporting data. No variances to applicable rules governing the construction
and / or operation of the permitted facilities are granted unless specifically requested and granted in
this permit.
4. The issuance of this permit does not exempt the Permittee from complying with any and all statutes,
rules, regulations, or ordinances, which may be imposed by other government agencies (local, state,
and federal) that have jurisdiction. Of particular concern to the Division are applicable river buffer
rules in 15A NCAC 02B .0200, erosion and sedimentation control requirements in 15A NCAC
Chapter 4 and under the Division's General Permit NCG010000, and any requirements pertaining to
wetlands under 15A NCAC 02B .0200 and 02H .0500.
WQ0015491 Version 3.0 Shell Version 070531 Page 5 of 7
5. In the event there is a desire for the facilities to change ownership, or there is a name change of the
Penrittee, a formal permit request must be submitted to the Division on official Division forrn(s),
documentation from the parties involved, and other supporting materials as may be appropriate. The
approval of this request will be considered on its merits and may or may not be approved. The
Permittee of record shall remain fuliy responsible for compliance until a permit is issued to the new
owner.
6. The Permittee shall retain a set of approved plans and specifications for the life of the facilities
permitted herein.
7. The Permittee shall maintain this permit until all permitted facilities herein are properly closed or
permitted under another permit issued by the appropriate permitting authority.
$. The Permittee must pay the annual fee within thirty (30) days after being billed by the Division.
Failure to pay the fee accordingly may cause the Division to initiate action to revolve this permit
pursuant to 15A NCAC 02T .0105(e).
Permit issued this the 29t°' day of May 2005
NORTH C OLINA ENVIRONMENTAL MANAGEMENT COMMISSION
COleen H. Sullins, Director
Division of Water Quality
By Authority of the Environmental Management Commission
Permit Number WQ0015491
WQ0015491 Version 3.0 Shell Version 070531 Page 6 of
This Page Blank
WQ0015491 Version 3.0 Shell Version 070531 Page 7 of 7
ATTACHMENT A - LIMITATIONS AND MONITORING REQUREMENTS
PPI 001— WWTF EFFLUENT
Permit Number: WQ0015491 Version: 3.0
EFFLUENT CHARACTERISTICS
EFFLUENT LIMITS
MONITORING REQUIREMENTS
Parameter Description - PCS Code
p
Monthly Average'
Weekly Average
Daily Maximum`
Measurement
Frequency
Sample
Type
Coliform, Fecal MF, M-FC Broth,44.5C - 31616
b
3 X year'
Grab
Nitrogen, Nitrate Total (as N) - 00620
3 X year
Grab
Solids, Total Suspended - 00530
3 X yea rd
Grab
Flow, in conduit or thru treatment plant - 50050
9,999
gpd
Monthly
Estimate
Nitrogen, Kjeldahl, Total (as N) - 00625
3 X year'
Grab
pH - 00400
Weekly
Grab
Chlorine, Total Residual - 50060
Weekly
Grab
Nitrogen, Ammonia Total (as N) - 00610
3 X yeard
Grab
BOD, 5-Day (20 Deg. C) - 00310
1
1
3 X yea?
Grab
'Monthly averages for all but fecal coliform shall be the arithmetic mean of all samples collected during the reporting period.
b Monthly average for fecal coliform shall be the geometric mean of all samples collected during the reporting period.
Daily maximum shall be the maximum value of all samples collected during the reporting period.
d 3 X year sampling shall be conducted during March, July, and November.
WQ0015491 Version 3.0 Attachment A Page 1 of 2
THIS PAGE BLANK
WQ00154— Version lO — Attachment A —fie 2 of 2
ATTACHMENT B - APPROVED LAND APPLICATION SITES AND LIMITATIONS
Caraway Speedway - WWTF
Permit Number: WQ0015491 Version: 3.0
UTILIZATION AREA INFORMATION
APPLICATION LIMITATIONS
Field/
Basin
Owner
County
Latitude
Longitude
Net
Acreage
Dominant
Soil Series
parameter
Rate
Yearly
Max
Linits
0 f
Caraway Speedway
Randolph
35045'56"
79053'05"
.49
01284 - Application Surface Irrigation
0.15
26
inches
02
Caraway Speedway
Randolph
34045'56"
79053'05"
.49
01284 - Application Surface Irrigation
0.15
26
inches
03
Caraway Speedway
Randolph
34045'56"
79a53'05"
.49
01284 - Application Surface Irrigation
0.15
26
inches
04
Caraway Speedway
Randolph
35145'56"
79'53'05"
49
01284 - Application Surface Irrigation
0.15
26
inches
Total
1.9.6
WQ0015491 Version 3.0 Attachment B Page 1 of 2
THIS PAGE BLANK