HomeMy WebLinkAboutWQ0011859_Final Permit_19960229State of North Carolina
Department of Environment,
Health and Natural Resources
Division of Environmental Management
James B. Hunt, Jr., Governor
Jonathan B. Howes, Secretary
A. Preston Howard, Jr., P.E., Director
17
A&4
�EHNR
February 29, 1996
Mr. J. Rex Eatman
3141 John Humphries Wynd, Suite 200
Raleigh, NC 27622
Subject: Permit No. WQ0011859
Mr. Eatman Residence
Single Family Wastewater
Spray Irrigation Facility
Dear Mr. Eatman: Wake County
In accordance with your application received December 14, 1995, we are forwarding herewith
Permit No. WQ0011859, dated February 29, 1996, to Mr. J. Rex Eatman for the construction and
operation of the subject single family wastewater treatment and spray irrigation facilities.
This permit shall be effective from the date of issuance until February 28, 2001 and shall be subject
to the conditions and limitations as specified therein. Please pay particular attention to the monitoring
requirements in this permit. Failure to establish an adequate system for collecting and maintaining the
required operational information will result in future compliance problems.
If any parts, requirements, or limitations contained in this permit are unacceptable, you have the
right to request an adjudicatory hearing upon written request within thirty (30) days following receipt of
this permit. This request must be in the form of a written petition, conforming to Chapter 150B of the
North Carolina General Statutes, and filed with the Office of Administrative Hearings, P.O. Drawer
27447, Raleigh, NC 27611-7447. Unless such demands are made this permit shall be final and binding.
One set of approved plans and specifications is being forwarded to you. If you need additional
information concerning this matter, please contact Mr. Randy Kepler at (919) 733-5083 extension 544.
Sincerely,
- j
` "Preston Howard, Jr., P.E.
d
cc: Wake County Health Department
Raleigh Regional Office, Water Quality Section
Training and Certification Unit
Facilities Assessment Unit
P.D. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-5083 FAX 919-733-9919
An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper
fL
NORTH CAROLINA
ENVIRONMENTAL MANAGEMENT COMMISSION
DEPARTMENT OF ENVIRONMENT, HEALTH AND NATURAL RESOURCES
RALEIGH
SINGLE FAMILY SPRAY IRRIGATION PERMIT
In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as
amended, and other applicable Laws, Rules, and Regulations
PERMISSION IS HEREBY GRANTED TO
Mr. J. Rex Eatman
Wake County
ayaAftl I
construction and operation of a 480 GPD spray irrigation wastewater treatment and disposal system
consisting of a 1,000 gallon baffled septic tank, two 144 ft2 surface sand filters, a tablet chlorinator, a
3,000 gallon storage/pump tank, and a 13,960 ft2 spray irrigation area to serve the Mr. J. Rex Eatman
Residence, with no discharge of wastes to the surface waters, pursuant to the application received
December 14, 1995, and in conformity with the project plan, specifications, and other supporting data
subsequently filed and approved by the Department of Environment, Health and Natural Resources and
considered a part of this permit.
This permit shall be effective from the date of issuance until February 29, 2001 and shall be subject
to the following specified conditions and limitations:
I. PERFORMANCE STANDARDS
Upon completion of construction and prior to operation of this permitted facility, a
certification must be received from a professional engineer certifying that the permitted
facility has been installed in accordance with this permit, the approved plans and
specifications, and other supporting materials. Mail the Certification to the Water Quality
Permits and Engineering Unit, P.O. Box 29535, Raleigh, NC 27626-0535.
2. The Raleigh Regional Office, telephone number 919-571-4700, shall be notified at least
forty-eight (48) hours in advance of operation of the installed facilities so that an in-place
inspection can be made. Such notification to the regional supervisor shall be made during
the normal office hours from 8:00 a.m. until 5:00 p.m. on Monday through Friday,
excluding State Holidays.
3. The spray irrigation facilities shall be effectively maintained and operated at all times so that
there is no discharge to the surface waters, nor any contamination of ground waters which
will render them unsatisfactory for normal use. In the event that the facilities fail to
perform satisfactorily, including the creation of nuisance conditions or failure of the
irrigation area to adequately assimilate the wastewater, the Permittee shall take immediate
corrective actions including those actions that may be required by the Division of
Environmental Management, such as the construction of additional or replacement
wastewater treatment and disposal facilities.
4. The issuance of this permit shall not relieve the Permittee of the responsibility for damages
to surface or groundwaters resulting from the operation of this facility.
5. The sand media of the surface sand filters must comply with the Division's sand
specifications. The engineer's certification will serve as evidence that these specifications
have been met.
6. A leakage test shall be performed on the septic tank and dosing tank to insure that any
exfiltration occurs at a rate which does not exceed twenty (20) gallons per twenty-four (24)
hours per 1,000 gallons of tank capacity, The engineer's certification will serve as proof of
compliance with this condition.
7. If excavation into bedrock is required for the installation of the septic tank or sand filter, the
pit shall be lined with a 10 mil synthetic liner.
8. A sanitary tee shall be installed on the effluent pipe of the septic tank. The engineer's
certification will serve as evidence that these specifications have been met.
9. The residuals generated from these treatment facilities must be disposed in accordance with
General Statute 143-215.1 and in a manner approved by the North Carolina Division of
Environmental Management.
10. Diversion or bypassing of the untreated wastewater from the treatment facilities is
prohibited.
11. The following buffers shall be maintained:
a) 400 feet between wetted area and any residence or places of public assembly under
separate ownership,
b) 150 feet between wetted area and property lines,
c) 100 feet between wetted area and wells,
d) 100 feet between wetted area and drainageways or surface water bodies,
e) 50 feet between wetted area and public right of ways,
f) 100 feet between treatment/storage units and any wells, and
g) 50 feet between treatment units and property lines.
II. OPERATION AND MAINTENANCE REQUIREMENTS
I . The facilities shall be properly maintained and operated at all times.
2. Upon classification of the facility by the Certification Commission, the Permittee shall
employ a certified wastewater treatment plant operator to be in responsible charge (ORC) of
the wastewater treatment facilities. The operator must hold a certificate of the type and
grade at least equivalent to or greater than the classification assigned to the wastewater
treatment facilities by the Certification Commission. The Permittee must also employ a
certified back-up operator of the appropriate type and grade to comply with the conditions
of Title 15A, Chapter SA, .0202. The ORC of the facility must visit each CIass I facility at
least weekly and each Class II, Ill, and IV facility at least daily, excluding weekends and
holidays, and must properly manage and document daily operation and maintenance of the
facility and must comply with all other conditions of Title 15A, Chapter 8A,.0202.
3. A suitable year round vegetative cover shall be maintained.
4. Irrigation shall not be performed during inclement weather or when the ground is in a
condition that will cause runoff.
5. Adequate measures shall be taken to prevent wastewater runoff from the spray field.
6. The application rate shall not exceed a cumulative loading of 20.1 inches over any twelve
(12) month period at an instantaneous application rate not to exceed 0.2 inches per hour.
W
7. The facilities shall be effectively maintained and operated as a non -discharge system to
prevent the discharge of any wastewater resulting from the operation of this facility.
8. No type of wastewater other than that from the Mr. J. Rex Eatman Residence shall be
sprayed onto the irrigation area.
9. In the event that the sprinkler heads fail to achieve the design diameter of 36 feet due to
obstructions, the obstructions shall be removed or the sprinkler heads shall be raised and
supported to such height that the design diameter is achieved.
10. No traffic or equipment shall be allowed on the disposal area except while installation
occurs or while normal maintenance is being performed.
11. The spray irrigation field shall be fenced with at least a two strand wire fence.
12. The Permittee is responsible for the operation and maintenance of the entire treatment and
disposal system including, but not limited to, the following items:
a. The septic tank shall be checked annually and pumped out as needed.
b. The tablet chlorinator shall be checked every week. Tablets shall be added so as to
provide proper chlorination.
c. The storage, pump, and alarm systems shall be inspected weekly. The scum layer shall
be removed at the same interval as the septic tank is cleaned out.
d. The spray system shall be inspected weekly to make certain of the sprayers proper
operation, that the vegetative growth allows a proper spray pattern, that the soil is
assimilating the disposed treated wastewater with no surface runoff, and that no
objectionable odors are being generated.
III. MONITORING AND REPORTING REQUIREMENTS
1. Any monitoring deemed necessary by the Division of Environmental Management to insure
surface and ground water protection will be established and an acceptable sampling
reporting schedule shall be followed.
2. The Permittee shall maintain records of all maintenance performed on the system and
irrigation area, as required in Condition II 12 for a minimum of five years. This
information shall be provided to the Division of Environmental Management upon request.
3. Noncompliance Notification:
The Permittee shall report by telephone to the Raleigh Regional Office, telephone number
919-571-4700, as soon as possible, but in no case more than 24 hours or on the next
working day following the occurrence or first knowledge of the occurrence of any of the
following:
a. Any process unit failure, due to known or unknown reasons, that renders the facility
incapable of adequate wastewater treatment, such as mechanical or electrical failures of
pumps, spray heads, etc.; or
b. Any failure of a pumping station or treatment facility resulting in a by-pass directly to
receiving waters without treatment of all or any portion of the influent to such station or
facility.
Persons reporting such occurrences by telephone shall also file a written report in letter
form within 15 days following first knowledge of the occurrence. This report must outline
the actions taken or proposed to be taken to ensure that the problem does not recur.
IV. INSPECTIONS
Adequate inspection, maintenance, and cleaning shall be provided by the Permittee to
insure proper operation of the subject facilities.
2. Any duly authorized officer, employee, or representative of the Division of Environmental
Management may, upon presentation of credentials, enter and inspect any property,
premises or place on or related to the disposal site or facility at any reasonable time for the
purpose of determining compliance with this permit, may inspect or copy any records that
must be maintained under the terms and conditions of this permit, and may obtain samples
of groundwater, surface water, or leachate.
V. GENERAL CONDITIONS
I . This permit shall become voidable unless the facilities are constructed in accordance with
the conditions of this permit, the approved plans and specifications, and other supporting
data.
2. This permit is effective only with respect to the nature and volume of wastes described in
the application and other supporting data.
3. This permit is not transferable. In the event there is a desire for the facilities to change
ownership, or there is a name change of the Permittee, a formal permit request must be
submitted to the Division of Environmental Management accompanied by an application
fee, documentation from the parties involved, and other supporting materials as may be
appropriate. The approval of this request will be considered on its merits and may or may
not be approved.
4. Upon the availability of a municipal or regional sewerage collection system, the subject
wastewater treatment facilities shaII be abandoned and all wastewater discharged into the
municipal or regional sewerage system.
5. Failure to abide by the conditions and limitations contained in this permit may subject the
Permittee to an enforcement action by the Division of Environmental Management in
accordance with North Carolina General Statute 143-215.6(a) to 143-215.6(c).
6. The issuance of this permit does not preclude the Permittee from complying with any and
all statutes, rules, regulations, or ordinances which may be imposed by other government
agencies (local, state, and federal) which have jurisdiction.
7. This permit may be revoked if the Permittee fails to abide by the conditions of the
"Operation and Maintenance Agreement" previously signed by the Permittee.
8. A set of approved plans and specifications for the subject project must be retained by the
Permittee for the life of the project.
9. The Permittee, at least six (6) months prior to the expiration of this permit, shall request its
extension. Upon receipt of the request, the Commission will review the adequacy of the
facilities described therein, and if warranted, will extend the Permit for such period of time
and under such conditions and limitations as itmay deem appropriate.
Permit issued this the Twenty Ninth day of February, 1996
NORTH CAROLINA ENVIRON-NIENTAL MANAGEMENT COMMISSION
A. -Preston Howard, Jr., P.E., Director
Division of Environmental Management
By Authority of the Environmental Management Commission
Permit Number WQ0011859
Permit No. WQOOI 1859
February 29, 1996
ENGINEER'S CERTIFICATION
I, , as a duly registered Professional Engineer in the State of North
Carolina, having been authorized to observe (periodically, weekly, full time) the construction of the
project, ,
Project Name
Location
for the
Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation
of the construction such that the construction was observed to be built within substantial compliance and
intent of this permit, the approved plans and specifications, and other supporting materials.
Signature
Date
Registration No.
OPERATION AND MAINTENANCE AGREEMENT FOR THE
DIVISION OF ENVIRONMENTAL MANAGEMENT
Name: J. Rex Eatman
Address: 3141 John Hum hries Wynd - Suite 200
City: R a l e i h State: N - C
Single Family Residence Wastewater Treatment System
Final Disposal by Spray Irrigation
Permit No.
wake County
I agree to operate and maintain the wastewater treatment system as follows:
ZIP: 27622
1. The Permittee is responsible for the operation and maintenance of the entire treatment and
disposal system including, but not limited to, the following items:
a. The septic tank shall be checked every six (6) months and pumped out as required.
b. The tablet chlorinator shall be checked every week until the actual usage rate is established
and thence on a monthly basis. Tablets shall be added so as to provide proper chlorination.
c. The storage system, pump system, and alarm system shall be inspected monthly. The
scum layer shall be removed at the same interval as the septic tank is cleaned out,
d. The spray system shall be inspected monthly to make certain of the sprayers proper
operation, that the vegetative growth allows proper spray patterns, that the soil is absorbing
the disposed treated wastewater with no surface runoff, and that no objectionable odors are
being generated.
2. Failure of the Permittee to properly operate this system is subject to a penalty up to $10,000 per
day.
3. Failure to meet permit conditions or violation of the State's surface or groundwater regulations
will require cessation of occupancy of the residence.
I understand that failure to comply with these conditions along with the permit conditions may result in
voiding the permit,
l�dSA•Y .�
f'(T0f �
C r�
t 1
b'fa'i� �ignature.
Date-.
Date: /a-- ] 3—%S
`Q
M
M
RATING SCALE FOR CLASSIFICATION OF
(WATER POLLUTION CONTROL SYSTEMS
tante of Facility: ?1Vlij
Owner or Contact Person: 11
Malling Address: 6i t, 0 76
County:Telephone: %/f — 7ZZ
Present Classification: New Facility Exisiirig Facility
NPDES Per. No. NC 0 Nondisc. Per, No.WQQ01 I �51 Health Dept,Per No.
Rated by: rG Telephone: 671- �17DU Date: 2"aE
Reviewed by: _ Health Dept. Telephone:
5 Regional Office Telephone: -5-7 -- 7, --
Central Offi e Telephone:
CRC: Grade Telephone:
Check Classifications): Subsurface Spray Irrigation Land Application
Wastewater Classification: (Circle One) l it 111 IV Total Points:
-------------------------------------------------------------
^✓;x'-'>~S. 7 EATED r, r.., R�--{. E G!
tS!D^RE''1`;N TR`A hz�'rT TrEc !R�`SC0= IFCATkk IA1�'� YS JSt7"SI I"Y=
'7Y �'ITF1FI. s F 'L-aF
SUBSUr,FACE CLfSSiFlCr; IXXq
(checi: a`,! its that ap-p;y)
1. Se: tiY tanKS
2. p=mp Santis
3. siphon, or pump -dosing syslems
4. sand filters
5. grease Irapiinlercepfor
B. oil"water separators
7, gravity subsjriace treatment an! disposal:
S, pressure subsurface treatment and disposal
SPRAY IRR#GAT ON CLASSIFICATION
(check all uriils that apply)
1. preliminary trealment (definiiion no, 32 }
2- goons
3, eptic tanks
4. tanks
5. umps
6. sandfillers
7. grease Irapinlerceptor
S. �sprayi�irnAlqaVon
i#�ialer separators
3.n
10,addition for nutrient/algae control
11. of wastewater
In addition to the above ciessificstions, pretreatment of wastewater In excess of these components shal.
be rated using the point rating system and will require an operator with an appropriate due! certification .
LAND APPLICAT!C)N/RESIDUALS CLASSIFICATION (App)ies only to permit holder)
1. Land aprpUcalion of biosolids, residuals or contaminate -i soils on a designated site.
-------------------------------------------------------------
WASTEWATER TREA NiEN'T FACILITY CLASSIFk;ATIU4
The fallowing systems shall be assigned a Class 1 cia.ssilicakon, Unloss the flow is of a signilicani quantity or the technology is unuscally
aornplex, to require consideration by the Commission on a case-by-case basis: (Check it Appropriate)
1. Cii'waler Separator Systems consisting only of physical separation, pumps and disposal;
2. Septic Tank/Sand Filler Systems consisting only of septic tanks, dosing apparalus, pumps,sand filters, disinfection
and direct discharge;
3. Lagoon Systems consisting only of preliminary trealment, lagoons, pumps, disinfection, necessary chemical Irealmen! for
algae or nulrienl control, and direct discharge;
4. Closed-loop Recycle Systems;
5- Groundwaler Remediation Sysiems consisting only of oil/waier separators, pumps, air -stripping, carbon adsorption, disinte"ion
and dispo� -J;
E. Aruac0ure operations with discharge to surface waters;
7. Wa!er Pant sludge handling and back -wash water treatment;
9. Seafood processing consisting of screening and disposal.
9. Sinele4amity discharging systems, with the exception of Aerobic Treatment Units, will be dass:Iied it pen nine -d a,,!er .luiy
1993 or it upon inspection by the Division, it is found chat the system is nol being adequateiy operated or maintained. Such
systems %it! be nclified of the classification or reclassilicalion by the Commission, in wdiing-