HomeMy WebLinkAboutWQ0004977_Final Permit_19910627p State of North Carolina Department of Environment, Health and Natural Resources Division of Environmental Management 512 North Salisbury Street • Raleigh, North Carolina 27011 P) 1110's G. \•i,inirl,-Governor William W. Colley, Jr., Swrctary Ms. Patricia Y. Duncan Rote 2, Box 239A China Grove, North Carolina 28023 Dear -NIs. Duncan: Gcorgc T. Evcrcu, Ph.D Director June 27, 1991 Subject: Permit No. WQ0004977 Patricia Y. Duncan Dog Kennel Subsurface Disposal System Cabarrus County In accordance with your application received April 17, 1991, we are forwarding herewith Permit No. WQ0004977, dated June 27, 1991, to Patricia Y. Duncan for the construction and operation of a 150 GPD subsurface wastewater disposal system. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. Please pay particular attention to the monitoring requirements in this permit. Failure to establish an adequate system for collecting and maintaining the required operational information will result in future compliance problems. If any parts, requirements, or limitations contained in this permit are unacceptable to you, you have the right to request aII adjudicatory hearing upon written request within 30 days following receipt of this hermit. This request must be in the forn of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, P.O. Drawer 27447, Raleiah, NC 27611-7447. Unless such demands are made this permit shall be final and binding. One set of approved plans and specifications is being forwarded to you. If you need additional information concerning this matter, please contact Mr. Dana Bolden at 919/ 733-5083. cc: Cabarrus County Health Department Mooresville Regional Office Groundwater Section Training and Certification Unit David A. Roberts, P.E. Regional Offices Asheville- FayCt€evillc Mooresville Raleigh Washington Wilmington 1Vinstoll-S211C111 704/2x]-6208 919/480-1541 704/663-1699 919/733-2314 919/946-6481 919/395-3900 919/761-2351 Pollution Prevention Pays P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-7015 An Equal Opportunity Affirmative Action Employer -U, NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT, HEALTH AND NATURAL RESOURCES RALEIGH SUBSURFACE DISPOSAL SYSTEM PERMIT In accordance with the provision: of Article 21 of Chapter 143, General Statutes of'North C..rolina as amended, and other applicable Laws, Rules, and RegLll�ttioIls PERMISSION IS HEREBY GRANTED TO Patricia Y. Duncan Cabarrus County FOR THE cor7struction and operation of a 150 GPD subsurface wastewater disposal system consisting of a 3,000 1Wallon septic: tank, a 1,500 gallon pump tank with a 44 GPM pump and high water alarm, approximately 245 linear feet of three inch supply manifold, and an 800 ft2 low pressure pipe nitrification field with approximately 400 linear feet of 1.5 inch distribution piping in 24 inch wide trenches to serve a dog 4ennel with no (Iischarge of wastes to the surface waters, pursuant to the application received April 17, 1991 and �n conformity with the project plan, specifications, and other supporting data subsequently filed and approved by the Department of Environment, Health and Natural Resources and considered a part of this permit. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the following specified conditions and limitations: PERFORMANCE STANDARDS 1. Upon completion of construction and prior to operation of this permitted facility, a certification must be received from a professional engineer certifying that the pernnitted facility has been installed in accordance with this permit, the approved plans and specifications. Mail the Certification to the Permits and Engineering Unit, P.O. Box 29535, Raleigh, NC 27626-0535. ?. The Mooresville Regional Office, phone no. (704)663-1699, shall be notified at least forty-eight (48) hours in advance of backfilling of the installed facilities so that an in-place inspection can be made. Such notification to the regional supervisor shall be made during the normal office hours from 8:00 a.m. until 5:00 p.m. on Monday through Friday, excluding State Holidays. In the event that the facilities fail to perform satisfactorily, including the cre, on of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as construction of additional or replacement wastewater treatment or disposal facilities. 4. The issuance of this permit shall not relieve the Permittee of the responsibility for damages to surface or groundwaters resulting from the operation of this facility. 5. This permit shall become voidable if the soils fail to adequately absorb the wastes and tllay be rescinded unless the facilities are installed, maintained, and operated in a manner which will protect the assigned water quality standards of the surface waters and 001-ound waters. C. Adequate measures shall be taken to divert stormwater from the disposal area and prevent wastewater runoff from the subsurface disposal field. 7. The sludge generated from these treatment facilities trust be disposed of in accordance with General Statute 143-215.1 and in a manner approved by the North Carolina Division of Environmental Management. A usable reserve area shall be maintained for wastewater disposal. The reserve area shall have the capability of accommodating the average daily flow of the facility being served without exceeding the loading rates of the reserve area while meeting all required buffer requirements. 9. Diversion or bypassing of the untreated wastewater from the treatment facilities is prohibited. 10. The following buffers shall be maintained: a) 100 feet between disposal area and any public or private water supply including wells b) 100 feet between disposal area and "SA and SB" classified surface waters C) 50 feet between disposal area and any stream, lake, river or natural drainageway d) 50 feet between disposal area and property lines e) 10 feet between disposal area and surface water interceptor drains or diversions (upslope) f) 25 feet between disposal area and surface water interceptor drains or diversions (downslope) and groundwater drainage systems. 11. A leakage test shall be performed on the septic tank and dosing tank to insure that any exfiltration occurs at a rate which does not exceed twenty (20) gallons per twenty-four (24) hour per 1,000 gallons of tank capacity. The engineer's certification will serve as proof of compliance with this condition. I1. OPERATION AND MAINTENANCE REQUIREMENTS The facilities shall be properly maintained and operated at all times. 2. Upon classification of the facility by the Certification Commission, the Permittee shall employ a certified wastewater treatment plant operator to be in responsible charge of the wastewater treatment facilities. The operator must hold a certificate of the type and grade at least equivalent to the classification assigned to the wastewater treatment facilities by the Certification Commission. 3. The application rates to the disposal field shall not exceed 0.187 gallons/day/ft'. 4. The facilities shall be effectively maintained and operated as a non -discharge system to prevent the discharge of any wastewater resulting from the operation of this facility. 2 5. No traffic or equipment shall be allowed on the disposal area except while installation occurs or while normal maintenance is being performed. 6. A suitable cover shall be maintained on the nitrification field and the field shall be routinely mowed. The clippings shall be periodically removed to prevent the build-up of thatch. III. MONITORING AND REPORTING REQUIREMENTS 1. Any monitoring deemed necessary by the Division of Environmental Management to insure surface and ground water protection will be established and an acceptable sampling reporting schedule shall be followed. 2. Noncompliance Notification: The Permittee shall report by telephone to the Mooresville Regional Office, telephone no. (704)663-1699, as soon as possible, but in no case more than 24 hours or on the next working day following the occurrence or first knowledge of the occurrence of any of the following: a. Any occurrence at the wastewater treatment facility which results in the treatment of significant amounts of wastes which are abnormal in quantity or characteristic, such as the dumping of the contents of a basin or tank; the known passage of a slug of hazardous substance through the facility; or any other unusual circumstances. b. Any process unit failure, due to known or unknown reasons, that render the facility incapable of adequate wastewater treatment such as mechanical or electrical failures of pumps, aerators, compressors, etc. C. Any failure of a pumping station, sewer line, or treatment facility resulting in a by- pass of all or any portion of the influent to such station or facility. d. Any time that self-monitoring information indicates that the facility has gone out of compliance with its permit limitations. Persons reporting such occurrences by telephone shall also file a written report in letter form within 15 days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. TV. GROUNDWATER REQUIREMENTS 1. Any groundwater quality monitoring as deemed necessary by the Division of Environmental Management shall be provided. V. INSPECTIONS 1. Adequate inspection, maintenance, and cleaning shall be provided by the Permittee to insure proper operation of the subject facilities. 3 2. The Permittee or his designee shall inspect the wastewater treatment and disposal facilities to prevent malfunctions and deterioration, operator errors and discharges which may cause or lead to the release of wastes to the environment, a threat to human health, or a nuisance. The Permittee shall keep an inspection log or summary including at least the date and time of inspection, observations made, and any maintenance, repairs, or corrective actions taken by the Permittee. This log of inspections shall be maintained by the Permittee for a period of three years from the date of the inspection and shall be made available upon request to the Division of Environmental Management or other pern�tting authority. Any duly authorized officer, employee, or representative of the Division of Environmental Management may, upon presentation of credentials, enter and inspect any property, premises or place on or related to the disposal site and facility at an\• reasonable time for the purpose of determining compliance with this permit; may inspect or copy any records that must be kept under the terms and conditions of this permit; or may obtain samples of groundwater, surface water, or leachate. VL GENERAL CONDITIONS This permit shall become voidable unless the facilities are constructed in accordance with the conditions of this permit, the approved plans, specifications and other supporting data. 2. This permit is effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. This permit is not transferable. In the event there is desire for the facilities to change ownership, or there is a name change of the Permittee, a formal permit request must be submitted to the Division of Environmental Management accompanied by an application fee, documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request will be considered on its merits and may or may not be approved. 4. Prior to any transfer of this land, a notice shall be given to the new owner that gives full details of the materials applied or incorporated at this site. 5. A set of approved plans and specifications for the subject project must be retained by the applicant for the life of the project. 6. The annual administering and compliance fee must be paid by the Permittee within thirty (30) days after being billed by the Division. Failure to pay the fee accordingly may cause the Division to initiate action to revoke this permit as specified by 15 NCAC 2H .0205 (c)(4). 7. Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to an enforcement action by the Division of Environmental Management in accordance with North Carolina General Statute 143-215.6. 8. The wastewater treatment facility shall connect to a publicly owned areawide sewage collection system within 180 days of its availability. All discharge of wastewater to the system shall cease at the time of the connection to the sewerage collection system. 9. The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction. 11 Permit issued this the 27th day of June, 1991 CAROLINA ENV)RONMENTAL MANAGEMENT COMMISSION fir* T. Everetw'Dj'reeto�. 0 Division of Environ gent Tan gement By Authority of the Environ M" ental Management Commission Pernit Number WQ0004977 Permit No. NIIQ0004977 June 27, 1991 Engineer's Certification 1, _ _ as a duly registered Professional Engineer in the State- of North Carolina. having been authorized to observe (periodically, weekly, full time) the construction of the pz•oject, Proiect 1Vame Location for the. Pernii ttee hereby state that, to the best of my abilities, clue care and diligence was used in the observation of tite construction such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications. SiLmature Date 0 Registration No. _L?Mrr r� l .`.IIA' �_ 's .��� 1\\7�i''>\ -� ,✓/ '/� ; n I I'119; \ tel! ( l�\\� l � .. r 6sa \\\}�Cljl-(I i]S E� ' \ �- C: \ �t 1 `_ � I'� 1 � ���/// ���' ',•' I r /% r��,. ^� � LaRe �l)/ �(o♦ I � t '�l ale � � ,I'. A / I>,��, as J�\, l� I�/i�6° (r� ��, l��J�.�, JI `P m LOE Yo'\ // T �l1 i �It ti ' / lr 1✓ --� � �.///t ;�?3�)��t�1,o �, I,C�--`���/'`1 �../�,•J� 1\\; �;'1�J1 /'`� '.J�\l'\�l� �j �\ -'.��< �I j �� 1 i it l ��C 1v - ��L. ] U ✓/ r �/ /i .vimI\ IN Lot! 1 0Al Ile f-11 .' � 'J /r \ �� �v Dyly i ✓��'I 1 \fit 'II�2 ✓''�'/� i/a �� IIID I' / ✓._\. e r\I� Q,C ��?J �/'�^r, 1 /u ��\.\,� �I 10 `\ � �� � \� �/ \J77��v�/� I %'�/�5� r� � ,il j��' �� o Y \ ✓ 'O��`5�`ll�l � �� rfed.-I [m e, -J. I, t� .)'ll ',,. �-L �I�✓,� w 1 ✓ ()>�.1-��0 �\ � r4 !�`l� 1. ��,� �'i� ✓g /) � � �� '�~`—�i ✓ of ,-I� 6 y//�1�\� �,Gr'�a I(P �'- /�_ � 1��`" GA i \, C'�f�l �C`i,,; :=;1 < Via.' l�\�� �.• :,�.� �� ,,,�>: / L�� �i.\�— <��� ���). )'11 ll� st�J t� r s ��/n✓i C�-.�/�� �willl /� I �g RATING SCALE FOR CLASSIFICATION OF FACILITIES Name of Plant:— Owner or Contact Person: Mailing Address: �d�a/e orL �v—7 County: Cha -era 4 TOepttone: 70%1g4; 7-13_ _7 NPDES Permit No. NC00 Nondisc. Per, ND.�✓GZac2'�`!�17� lssueDate: JliKG 9% 1,911 _Expiration Date: a,,4A.*1kg4iik'A!<i Existing Facility New Facility Rated By: > deet Date: Reviewed (Train. & Cert-) Reg. Office Reviewed (Train- & Cert.) Central Office ORC Grade ITEM POINTS ITEM POINTS (1) Industrial Pretreatment Units and/or (4) PRIMARY'TREATMENT UNITS Industrial Pretreatment Program (a) Septic Tank (see definition no. 43) .............. Q (see definition No. 33) 4 (b) Imhoff Tank .................................. 5 (2)I N FLOW OF PLANT W GPD (c) Primary Clarifiers ........................... (not applicable to non -contaminated cooling (d) Settling Ponds or Settling Tanks for inorganic waters, sludge handling facilities for water Non-toxic Materials (sludge handling facilities purilication plants, totally closed cycle for water purification plants, sand, gravel, systems (def. No. 11), and facilities stone, and other mining operations except consisting only of item (4) (d) or Items (4) (d) recreational activities such as gem or gold and (11) (d)) mining) ...................................... 2 0 20,000 ... ...................... (5) SECONDARY TREATMENT UNITS 20,001 -- 50,000 .......................... 2 (a) Carbonaceous Stage 0,001 100,000 .......................... 3 (i)Aeralion - High Purity Oxygen System .. .. , 20 100,001 250,000 .......................... 4 Diffused Air System ........... 1 0 250,001 500,000..... ..................... 5 Mechanical Air System (fixed, 500,001 --1,000,000 .......................... 8 floating or rotor) .............. 8 1,000,001 -- 2,000,000 ......................... 10 Separate Sludge Reaeration ..... 3 2,000,001 (and up) - rate 1 poirnl additional for each (ii) Trickling Filter 200,000 gpd capacity up to a High Rale ................. . . 7 maximum of 30 Standard Rate ............... 5 Packed Tower ............... 5 Design Flow (gpd) �S� �j'� (iii) Biological Aerated Filler or Aerated _ Biological Filler ...................... 10 (iv) Aerated Lagoons ..................... . 10 (v) Rotating Biological Conlaclors .......... 1 0 (3) PRELIMINARY(vi) UNITS (see delinilion no. 32) Sand Filters - (a) Bar Screens intermittent biological .. intermittent 2 . - .... recirculating biological 3 or Mechanical Screens, Static Screens or (vii) Stabilization Lagoons ..... ... ........... 5 Comminuting Devices ....... 2 (viii)clariker ............... . ............ 5 (c) Grit Removal (ix) Single stage system for combined ............................... 1 carbonaceous removal of BOD and or (d) Mechanical or Aerated Grit Removal 2 nitrogenous removal by nitrification ........... (e) Flow Measuring Device (see def No. 12) (Points for this item ........ or i have to be in addition to items (5) (a) (f) Instrumented Flow Measvrement (i) through (5) (a) (viii) ................. 8 .............. (g) Preaeration 2 (x) Nutrient additions to enhance BOD ......... ............ 2 removal .......... . ................... (h) Influent Flow Equalization (xi) Biological Culture (-Super Bugs") addition ................... `i) Grease or Oil Separators - Gravity .......... 2 2 to enhance organic compound removal 5 Mechanical .......... 3 Dissolved Air Flotation. B (}) Prechlorination .... - 5