HomeMy WebLinkAboutNCG551477_Compliance Evaluation Inspection_20180723 TROY COOPER
Governor
MICHAEL S.REGAN
Sec,etur:
`t4 P
,Q' LINDA CULPEPPER
Water Resources Inter mi Director
Ern.uoilmen Lai Quakily
July 23, 2018
Stephen Quillen
474 Continental Drive '
Durham,NC 27712
Subject: Compliance Evaluation Inspection RECEIVED/DENRJDWR
Single Family Wastewater Treatment System
Residence at 474 Continental Drive,DurhamMi i 0 2 2018
Permit No.NCG551477 Water Resources
Durham County permitting Section
Dear Mr. Quillen. -
The subject residence is served by a discharging sandfilter waste treatment system. This type of system is
- permitted by the North Carolina Department of Environmental Quality(NCDEQ).NCDEQ records indicate
Joanne Vann is the owner however;Durham tax records list you as the owner of the subject property.Please
fill out the attached Name Ownership Change form and mail it to the address listed on the back of
page 2 of the form within 30 days of receipt of this letter.
On July 16, 2018, Mitch Hayes from the Raleigh Regional Office visited your single-family residence
(SFR)wastewater treatment system to evaluate compliance with the above pen-nit to discharge wastewater.
- The checked boxes below show what conditions were noted at your facility:
n In compliance: You are reminded to regularly maintain the chlorine disinfection and
dechlorination systems, have the effluent_sampledonce a year, and have the septic tank pumped
out every 3 to 5 years.Your good record of operation and meeting the permit requirements is highly
commended.
n Your home is improperly plumbed: Some of the wastewater discharges are gomg directly to
the environment without first passing through the treatment system. This must be corrected
immediately. Please submit a schedule to this office within 30 days of receipt of this letter that
states your plan for correcting this deficiency. The work is to be completed within the next 3
months.
n Disinfection: Your system is lacking disinfection, either chlorine tablets or a IJV light system.
New rules put into place on August 1,2007 require all SFR systems to have a means of disinfection
(and dechlorination when chlorine tablets are used to disinfect, if the system was installed since
that date). Since your system had no disinfection, the installation is to include a chlorine tablet
dispenser, a contact chamber capable of providing a minimum 30-minute contact time, and another
tablet dispenser that will hold dechlorination tablets.Please submit a schedule to this office within
20 calendar da s of receiet of this letter that states our elan for conectm• this deficient .
--- - I'r atment tablets missing or are wrong kind:You are responsible for always having chlorine
tablets and dechlorination tablets(if a required part'of your system)in place.They must be the kind
for wastewater treatment and not for swimming pools.
_ = "Notlit ing CDrap arc
Division of Water Resources, Raleigh Regional Office,Water Quality Operations Section http.//portal.ncdent.oig/web/wq/aps
1628 Mail Service Center,Raleigh,NC 27699-1628 Phone:(919)791'4200
- Location:3800 Bai sett Drive,Raleigh,NC 27609 Fax (919)788-7159
ff?7, wa^r y rr,,,„ r .= ,s' ,1:724,17-M,77:=0:: s ,, �znT q^;r-, "'? ,E%. :u:i.. :;3'ti ::„ ;
....�.,:;-�,>.v-;;^Y�-,,..�--=r•",�-<x;`�'�.:5-ee«.'7,..,,,2<,�'n�F-.,. < *i��',�"� m fs�. .x-A��::e,..�,.µ.t;�,:i; ,, ' �=.�,
Dechlorination: Your system was installed after August 1, 2007, so must have a means of
dechlorination located downstream of the chlorinator and its contact chamber. See Disinfection
paragraph above. Please submit a schedule to this office within 20 calendar days of receipt of this
letter stating your plan for correcting this deficiency.
Pumping the septic tank:The septic tank should be pumped out every 3 to 5 years.A pumping
company can check the status periodically and determine when pumping is required.
I Failure to analyze the effluent: The effluent that is discharged from your system must be
anaLyzecLonce_eachyear. See Part I_(A) of your permit about his requirement.A list of NC certified
laboratories that provide this service was left at your residence during the inspection. Make
arrangements for sampling to be carried out within the next 3 months, and submit results to this
office within 3 weeks after the sampling-has been done.
I I Locations of treatment units are unknown: Determine this and report to this office within
30 days of receipt of this letter with a sketch or map.
I -I Other:
If you have questions or comments about this inspection or the requirements to take corrective action,please
contact Mitch Hayes at 919-791-4200.Licensed plumbers should be used to make plumbing changes within
your home. Contractors for installing disinfection or other equipment may be found in the Yellow Pages
under Environmental Consultants.
Sincerely,/
(-57/7
S. Daniel Smith,Regional Supervisor -
- Water Quality Regional Operations Section
Raleigh Regional Office
cc: RRO/SWP Files
Charles Weaver,NPDES Permitting Unit
Attachments
- — .— — :e-" "'dF z __ - _---'?�;x`P-—' -,,3r^`=.:m�v':t r: ;k'i ir'•1Pz;k sassfi;"".,:�r:.�t.'c r i:'ZR., ;;1`ro.-.f'",Ym-'Y"^ <`ai' '>v.'�,.;: y,.j ,fix, r
,r ri�==�!w��.;,, E'a:���°�n�,r - ,>�z� 'S�a.�
- ;
,,_,��-._�,��w��:: .r ,. , �•� a fit,