Loading...
HomeMy WebLinkAboutNC0021121_More Information Received_20180918 • Po Box70 • Mount Airy,N C 27030 • Phone 336-786-3597 • Fax 336-786-3573 CityofMtAiIyWWTP _ _._ _ ... September 18, 2018 RECEIVE©/®ENR/DWR Ms. Wren Thedford SEP 5 2018 NC DEQ/DWR/NPDES eater Resources 1617 Mail Service Center 0 Section Raleigh,N.C. 27699-1617 Subject: NPDES Permit NC 0021121 Renewal Dear Ms. Thedford, The City of Mount Airy requested renewal of NPDES Permit NC 0021121 on August 22, 2018. Enclosed please find the results along with page 10, Part D of the permit application for the four parameters not included on the Pollutant Scan in October 2015. The parameters are Antimony, Beryllium, Thallium, and total phenolic compounds. If you have any questions or require further information, please contact me at 336-786-3597. Sincerely, ej/141,-N-J Chris Marion WWTP ORC FACILITY NAME AND PERMIT NUMBER: PERMIT ACTION REQUESTED: RIVER BASIN: Mount Airy WWTP, NC0021121 Renewal Yadkin Pee-Dee r SUPPLEMENTAL APPLICATION INFORMATION PART D. EXPANDED EFFLUENT TESTING DATA Refer to the directions on the cover page to determine whether this section applies to the treatment works. Effluent Testing: 1.0 mgd and Pretreatment Works. If the treatment works has a design flow greater than or equal to 1.0 mgd or it has(or is required to have)a pretreatment program,or is otherwise required by the permitting authority to provide the data,then provide effluent testing data for the following pollutants. Provide the indicated effluent testing information and any other information required by the permitting authority for each outfall through which effluent is discharged. Do not include information on combined sewer overflows in this section. All information reported must be based on data collected through analyses conducted using 40 CFR Part 136 methods. In addition,these data must comply with QA/QC requirements of 40 CFR Part 136 and other appropriate QA/QC requirements for standard methods for analytes not addressed by 40 CFR Part 136. Indicate in the blank rows provided below any data you may have on pollutants not specifically listed in this form. At a minimum,effluent testing data must be based on at least three pollutant scans and must be no more than four and one-half years old. Outfall number: 001 (Complete once for each outfall discharging effluent to waters of the United States.) MAXIMUM DAILY DISCHARGE AVERAGE DAILY DISCHARGE POLLUTANT Number ANALYTICAL ML/MDL Conc. Units Mass Units Conc. Units Mass Units of METHOD Samples METALS(TOTAL RECOVERABLE),CYANIDE,PHENOLS,AND HARDNESS. ANTIMONY <.025 MG/L <.025 MG/L 3 EPA 200.7 0.025 ARSENIC <.01 MG/L <.01 MG/L 3 EPA 200.7 0.01 BERYLLIUM <.001 MG/L <.001 MG/L 3 EPA 200.7 0.001 CADMIUM <.002 MG/L <.002 MG/L 3 EPA 200.7 0.002 CHROMIUM <.005 MG/L <.005 MG/L 3 EPA 200.7 .0.005 COPPER .014 MG/L .011 MG/L 3 EPA 200.7 0.005 LEAD <.01 MG/L <.01 MG/L 3 EPA 200.7 0.01 MERCURY 6.28 NG/L 4.6 NG/L 3 EPA 1631 E 0.5 NICKEL <.01 MG/L <.01 MG/L 3 EPA 200.7 0.01 SELENIUM <.01 MG/L <.01 MG/L 3 EPA 200.7 0.01 SILVER <.005 MG/L <.005 MG/L 3 EPA 200.7 0.005 THALLIUM <.005 MG/L <.005 MG/L 3 EPA 200.7 0.005 ZINC .092 MG/L .066 MG/L 3 EPA 200.7 0.01 CYANIDE <.01 MG/L <.01 MG/L 3 SM4500CNE- 0.01 1999 TOTAL PHENOLIC .006 MG/L .0053 MG/L 3 EPA 420.1 0.005 COMPOUNDS HARDNESS(as CaCO3) 149 MG/L 67.7 MG/L 15 SM2340C 1997 1.0 Use this space(or a separate sheet)to provide information on other metals requested by the permit writer EPA Form 3510-2A(Rev. 1-99). Replaces EPA forms 7550-6&7550-22. Page 10 of 22 g44— ... RESEARdi : ANA[yTiCA[ Report of Analysis a . sz - eft LABORATORIES, INC. 1,,,;i t4=y 9/17/2018 For: City of Mount Airy WWTP �.% fAt '`G�►& 410_,, PO Box 70 �� ••�•t L Cf/,q''•• �'. Mount Airy, NC 27030 :Lc, ' �•O' ' :4 - Mount NC#34 -6:011 _ C Attn: Chris Marion NC#37701 r� ��� `%j.78Ct�rK ~ �•���7 ; ` , + � DAN ,t Client Sample ID: Plant Effluent Lab Sample ID: 55139-01 Site: City of Mt Airy WWTP Collection Date: 8/23/2018 10:00 Parameter Method Result Units Rep Limit Analyst Analysis Date/Time Antimony,Total EPA 200.7 <0.005 mg/L 0.005 SK 8/27/2018 Beryllium,Total EPA 200.7 <0.001 mg/L 0.001 SK 8/27/2018 Phenols EPA 420.1 <0.005 mg/L 0.005 DW 9/14/2018 Thallium,Total EPA 200.7 <0.005 mg/L 0.005 SK 8/27/2018 NA=not analyzed P.O.Box 473 106 Short Street Kernersville,North Carolina 27284 Tel:336-996-2841 Fax:336-996-0326 www.randalabs.com Page 1 r:;_coa_oas ic_v 1 Li