HomeMy WebLinkAbout20181254 Ver 1_Chadbourne 09-11-18_20180912PREPARED BY
ENGINEERING DEPARTMENT
CITY OF CONCORD
P.O. BOX 308
CONCORD N.C. 28026
(704) 920-5425
Surveyor's Seal
CONCORD, NORTH CAROLINA
CITY OF CONCORD
PREPARED BY
ENGINEERING DEPARTMENT
CITY OF CONCORD
P.O. BOX 308
CONCORD N.C. 28026
(704) 920-5425
Surveyor's Seal
PROJECT # :2017-026
CHADBOURNE AVE.
CULVERT REPLACEMENT
THIS PROJECT CONSISTS OF THE INSTALLATION OF A 7'x6' DOUBLE BARREL CONCRETE BOX CULVERT UNDER CHADBOURNE AVE AND
APPROXIMATELY 53'± LINEAR FEET OF 8" GRAVITY SEWER, 101'± LINEAR FEET OF 6" WATER MAIN, AND 1 FIRE HYDRANT. ALONG WITH
APPURTENANCES AND OTHER ASSOCIATED PROJECT WORK, FOR THE PURPOSE OF PROVIDING STORM, WATER, AND SANITARY SEWER
UPGRADES.
THE PROJECTED AMOUNT OF GROUND DISTURBANCE IS 0.84± ACRES.
WORK SHALL PROCEED IN SUCH A MANNER SO AS TO LIMIT THE AMOUNT OF GROUND DISTURBANCE BY HAVING ONLY ONE SECTION OF THE
DITCH OPEN AT A TIME THEREBY REDUCING THE POTENTIAL FOR LARGE QUANTITIES OF SEDIMENT TO BE TRANSPORTED OFF SITE.
SEEDING OF DENUDED AREAS SHALL BE DONE AS SOON AS POSSIBLE, BUT IN NO CASE LONGER THAN SOIL STABILIZATION TIME FRAMES
GIVEN IN THE PLANS. REMOVAL OF ALL SEDIMENTATION AND EROSION CONTROL DEVICES SHALL ONLY BE DONE AFTER APPROVAL HAS
BEEN COORDINATED WITH THE DEPARTMENT OF ENVIRONMENTAL QUALITY, THE CITY OF CONCORD, AND THE NORTH CAROLINA
DEPARTMENT OF TRANSPORTATION.
LOCATION AND PROTECTION OF ALL UTILITIES IN THE WORK AREA SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. PLEASE
NOTICE THAT THIS PROJECT CROSSES SEVERAL UNDERGROUND UTILITIES ALONG THE ROUTE OF WORK. MINIMUM SEPARATIONS BETWEEN
THE NEW SEWER LINES, WATER LINES, STORM PIPES, AND THESE UTILITIES SHALL BE HELD AT ALL TIMES. IN THE EVENT OF AN
UNFORESEEN CONFLICT, THE CONTRACTOR SHALL NOTIFY THE CITY OF CONCORD ENGINEERING DEPARTMENT IMMEDIATELY. ALL TRAFFIC
CONTROL AND SAFETY SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE CONDUCTED IN STRICT ACCORDANCE WITH THE
LATEST REVISION OF PART IV OF THE M.U.T.C.D., NCDOT, OSHA AND ALL OTHER LOCAL, STATE AND FEDERAL REGULATIONS.
COMPLETION OF THIS PROJECT IS ANTICIPATED TO TAKE 120 DAYS AFTER NOTICE BY THE CITY OF CONCORD TO PROCEED. FINAL
COMPLETION AND ACCEPTANCE OF THE WORK IS ANTICIPATED TO BE SPRING 2019.
NOTE:
CONDITIONS OF APPROVAL: NO WORK SHOWN IN THIS PLANS SHALL COMMENCE UNTIL THE CITY'S NOTICE TO PROCEED HAS BEEN ISSUED
AND THE NCDEQ DWR 401 WATER QUALITY CERTIFICATION AND USACE SECTION 404 PERMIT APPROVALS ARE OBTAINED; AND ANY
CONDITIONS IMPOSED BY NCDEQ DWR AND USACE SHALL BE CONSIDERED INCORPORATED HEREIN
Engineer's Seal
630
629
628
628
627
626
62
7
62
8
62
6
628
6316:1CHADBOURNE AVE CULVERT REPLACEMENTEXISTING SITE MAPPROJECT # : 2017-026PREPARED BY
ENGINEERING DEPARTMENT
CITY OF CONCORD
P.O. BOX 308
CONCORD N.C. 28026
(704) 920-5425
Surveyor's Seal
1.800.331.0008
1.800.252.1133
704.920.3000
704.920.5555
704.920.5555
704.392.8610
1.800.232.0144
1.800.769.3766
704.986.3700 Stanly Co Comm
1.800.632.4949
1.800.453.2530
N/A
1.800.752.7504
1.800.510.5678
1.877.776.2427
1.888.723.8010
704.378.2626 Option 5, 2, 1
1.800.922.6840
1.800.632.4949 NC One Call
704.788.4164 RRWWTP
1.800.800.6609
CHA
D
B
O
U
R
N
E
A
V
E
.
N
W
Engineer's Seal
630
629
628
628
627
626
62
7
62
8
62
6
628
6316:1CHADBOURNE AVE CULVERT REPLACEMENTDEMOLITION PLANPROJECT # : 2017-026PREPARED BY
ENGINEERING DEPARTMENT
CITY OF CONCORD
P.O. BOX 308
CONCORD N.C. 28026
(704) 920-5425
Surveyor's Seal
CHA
D
B
O
U
R
N
E
A
V
E
.
N
W
NOTES
1. REMOVAL OF TREES AND SHRUBS ARE TO BE MINIMIZED AS
MUCH AS POSSIBLE. CONTRACTOR TO AVOID AND MINIMIZE
DAMAGE TO THOSE TREES AND SHRUBS DETERMINED TO REMAIN.
2. ALL EXISTING SERVICE CONNECTIONS TO REMAIN IN SERVICE
AND TO BE PROTECTED DURING CONSTRUCTION. CONTRACTOR
SHALL LOCATE AND MAKE PROVISIONS IN ACCORDANCE WITH
THE CITY OF CONCORD FOR PROTECTION.
3. THE CONTRACTOR WILL BE REQUIRED TO MAINTAIN INGRESS
AND EGRESS TO ALL BUSINESSES AND DWELLINGS, AND EASY
ACCESS TO FIRE HYDRANTS.
CONTRACTOR TO OPEN
CUT ROADWAY AND
REPLACE ACCORDING TO
CITY OF CONCORD AND
NCDOT STANDARDS. SEE
SHEET 12 FOR TYPICAL
ROADWAYS CROSS
SECTION
ROAD CLOSED
BARRICADE TYPE III
NCDOT 1145.01
SEE SHT. 15 FOR
CLOSURE PLAN
ROAD CLOSED
BARRICADE TYPE III
NCDOT 1145.01
SEE SHT. 16 FOR
CLOSURE PLAN
CONTRACTOR TO TEMPORARILY RELOCATE
EX. MAILBOX. MAILBOX SHOULD BE RESET IN
IT'S ORIGINAL LOCATION AT THE COMPLETION
OF PROJECT.
CONTRACTOR TO REMOVE
EXISTING 48" CMP AND
EXISTING 60" CMP
CONTRACTOR TO REMOVE
EXISTING F.H. ASSEMBLY
CONTRACTOR TO REMOVE
EXISTING TREES AND
SHRUBS LOCATED WITHIN
20' FROM THE OPENING OF
THE EXISTING CULVERTS
CONTRACTOR TO REMOVE
EXISTING TREES AND
SHRUBS LOCATED WITHIN
20' FROM THE OPENING OF
THE EXISTING CULVERTS
CONTRACTOR TO ENSURE THAT PROPERTY OWNER HAS
ACCESS TO DRIVEWAY DURING CONSTRUCTION AT ALL TIMES.
IF NEEDED, CONTRACTOR TO BUILD TEMPORARY DRIVEWAY
WIDENING WITH DOT ABC MATERIAL. 15” STORM PIPE TO BE
EXTENDED UNDER WIDENING. CONTRACTOR TO REINSTATE
EXISTING DRIVEWAY AND DITCH TO EXISTING CONDITION.
CONTRACTOR TO
REMOVE EXISTING
SHRUBS IN CONFLCT
WITH PROPOSED
FIRE HYDRANT
1.800.331.0008
1.800.252.1133
704.920.3000
704.920.5555
704.920.5555
704.392.8610
1.800.232.0144
1.800.769.3766
704.986.3700 Stanly Co Comm
1.800.632.4949
1.800.453.2530
N/A
1.800.752.7504
1.800.510.5678
1.877.776.2427
1.888.723.8010
704.378.2626 Option 5, 2, 1
1.800.922.6840
1.800.632.4949 NC One Call
704.788.4164 RRWWTP
1.800.800.6609
LIMITS OF DISTURBANCE
Engineer's Seal
630
629
628
628
627
626
62
7
62
8
62
6
628
6316:1CHADBOURNE AVE CULVERT REPLACEMENTEROSION CONTROL PLANPROJECT # : 2017-026PREPARED BY
ENGINEERING DEPARTMENT
CITY OF CONCORD
P.O. BOX 308
CONCORD N.C. 28026
(704) 920-5425
Surveyor's Seal
CHA
D
B
O
U
R
N
E
A
V
E
.
N
W
CONTRUCTION/TREE
PROTECTION FENCING
COMPOST FILTER SOCK,
FILTREXX SILT SOXX, DIAMOND
SOCK OR EQUIVALENT
GRAVEL CONSTRUCTION
ENTRANCE, PER NCDOT
STD. 1607.01
NOTES
1. REMOVAL OF TREES AND SHRUBS
ARE TO BE MINIMIZED AS MUCH AS
POSSIBLE. CONTRACTOR TO AVOID
AND MINIMIZE DAMAGE TO THOSE
TREES AND SHRUBS DETERMINED TO
REMAIN.
2. STREAM AREAS IMPACTED DUE TO
SITE DEWATERING ACTIVITIES SHALL
BE REGRADED TO ITS
PRECONSTRUCTION CONTOURS AND
REVEGETATED WITH APPROPRIATE
NATIVE SPECIES, SUCH AS "BLUE
FLAG IRIS", "SOFT RUSH", AND
"LIZARD'S TAIL".
CONTRUCTION/TREE
PROTECTION FENCING
1.800.331.0008
1.800.252.1133
704.920.3000
704.920.5555
704.920.5555
704.392.8610
1.800.232.0144
1.800.769.3766
704.986.3700 Stanly Co Comm
1.800.632.4949
1.800.453.2530
N/A
1.800.752.7504
1.800.510.5678
1.877.776.2427
1.888.723.8010
704.378.2626 Option 5, 2, 1
1.800.922.6840
1.800.632.4949 NC One Call
704.788.4164 RRWWTP
1.800.800.6609
Engineer's Seal
PROPOSED 2-7' W x 6' H x 62' L
BARREL BOX CULVERTS
(SEE DETAILS SHEET 11)
PROPOSED TEMPORARY 62.47' of 8" DIP @ 0.30%
PROPOSED 62.47' of 8" DIP @ 2.69%
PROPOSED GRADE
PROPOSED GRADE
PROP. M.H.#1
5' DIA M.H.
STA:0+62.47
RIM:631.83
PROPOSED 8" DIP
PROPOSED 2-7' W x 6' H x 62' L
BARREL BOXED CULVERT
(SEE DETAILS SHEET 11)2:1
6
3
0
6
2
9
6
2
8628627 626627628626628631
6:1 3:12:12:12:1CHADBOURNE AVE CULVERT REPLACEMENTCULVERTPLAN & PROFILEPROJECT # : 2017-026PREPARED BY
ENGINEERING DEPARTMENT
CITY OF CONCORD
P.O. BOX 308
CONCORD N.C. 28026
(704) 920-5425
Surveyor's Seal
1.800.331.0008
1.800.252.1133
704.920.3000
704.920.5555
704.920.5555
704.392.8610
1.800.232.0144
1.800.769.3766
704.986.3700 Stanly Co Comm
1.800.632.4949
1.800.453.2530
N/A
1.800.752.7504
1.800.510.5678
1.877.776.2427
1.888.723.8010
704.378.2626 Option 5, 2, 1
1.800.922.6840
1.800.632.4949 NC One Call
704.788.4164 RRWWTP
1.800.800.6609
NOTES
1. CONTRACTOR TO REPLACE EXISTING
ROADWAY ACCORDING TO CITY OF
CONCORD AND NCDOT STANDARDS. SEE
SHT. 12 FOR TYPICAL CROSS SECTION.
2. PRIVATE UTILITIES, OTHER THAN
PRIVATE WATER LINES TO BE
RELOCATED BY OTHERS.
3. REMOVAL OF TREES AND SHRUBS ARE
TO BE MINIMIZED AS MUCH AS
POSSIBLE. CONTRACTOR TO AVOID AND
MINIMIZE DAMAGE TO THOSE TREES
AND SHRUBS DETERMINED TO REMAIN.
4. CONTRACTOR TO INSTALL PEDESTRIAN
SAFETY RAIL ALONG HEADWALLS /
WINGWALLS. PAINT COLOR SW 6258
FLAT SHEEN, OR EQUIVALENT. SEE
DETAIL IN SHT. 11.
Engineer's Seal
2:1
627
626
2:1
2:
1 CHADBOURNE AVE CULVERT REPLACEMENTUP-STREAM CROSS SECTIONPROJECT # : 2017-026PREPARED BY
ENGINEERING DEPARTMENT
CITY OF CONCORD
P.O. BOX 308
CONCORD N.C. 28026
(704) 920-5425
Surveyor's Seal
625
NOTE:
1. THESE PLANS AND DETAILS ARE MEANT TO SHOW THE
GENERAL INTENT OF THE WINGWALL DESIGN. CONTRACTOR
SHALL HAVE PRECAST MODULAR BLOCK WINGWALLS
DESIGNED, DETAILED AND SPECIFIED BY MANUFACTURER OR
MANUFACTURER'S REPRESENTATIVE LICENSED IN THE STATE
OF NORTH CAROLINA.
2. CONTRACTOR SHALL SUBMIT FINAL DESIGN AND
CALCULATIONS TO THE CITY OF CONCORD FOR APPROVAL.
3. CONTRACTOR TO INSTALL PEDESTRIAN SAFETY RAIL ALONG
HEADWALLS / WINGWALLS. PAINT COLOR SW 6258 FLAT
SHEEN, OR EQUIVALENT. SEE DETAIL IN SHT. 11.
626
620619618621622623624
61861962062162262362
4
Engineer's Seal
629628627
6266316:13:1
2:1 CHADBOURNE AVECULVERT REPLACEMENTDOWN-STREAM CROSS SECTIONPROJECT # : 2017-026PREPARED BY
ENGINEERING DEPARTMENT
CITY OF CONCORD
P.O. BOX 308
CONCORD N.C. 28026
(704) 920-5425
Surveyor's Seal
60
6
NOTE:
1. THESE PLANS AND DETAILS ARE MEANT TO SHOW THE GENERAL
INTENT OF THE WINGWALL DESIGN. CONTRACTOR SHALL HAVE
PRECASTMODULAR BLOCK WINGWALLS DESIGNED, DETAILED AND
SPECIFIED BY MANUFACTURER OR MANUFACTURER'S
REPRESENTATIVE LICENSED IN THE STATE OF NORTH CAROLINA.
2. CONTRACTOR SHALL SUBMIT FINAL DESIGN AND CALCULATIONS
TO THE CITY OF CONCORD FOR APPROVAL.
3. CONTRACTOR TO INSTALL PEDESTRIAN SAFETY RAIL ALONG
HEADWALLS / WINGWALLS. PAINT COLOR SW 6258 FLAT SHEEN, OR
EQUIVALENT. SEE DETAIL IN SHT. 11.
626
625
627
628
624623622621620619618617616
624
620619618617621617Engineer's Seal
TEMP. OUTLET. SEE NOTE 3
PROP. M.H.#1
5' DIA INSIDE DROP
STA:0+62.47
RIM:631.83
INV IN:626.10 8" PVC "E"
INV OUT:614.55 8" DIP "W"
INV OUT:625.90 8" DIP "W"
PROPOSED 62.47' of 8" DIP @ 2.69%
TO BE CONSTRUCTED AFTER
PROPOSED BOX CULVERT IS IN PLACE
TEMPORARY PIPE TO BE CONSTRUCTED
AND ACTIVIVATED BEFORE
AND DURING CULVERT CONSTRUCTION
62.47' of 8" DIP @ 0.30%
TO BE ABANDONED IN PLACE AND FILLED
WITH FLOWABLE FILL
AFTER PERMANENT PIPE IS ACTIVATED
WHEN CULVERT HAS BEEN INSTALLED
ROCK ELEVATION
PROP. M.H.#1
5' DIA M.H.
STA:0+62.47
RIM:631.83
PROPOSED 8" DIP
PROPOSED 2-7' W x 6' H x 62' L
BARREL BOXED CULVERT
(SEE DETAILS SHEET 11)CHADBOURNE AVE CULVERT REPLACEMENTSANITARY SEWERPLAN & PROFILEPROJECT # : 2017-026PREPARED BY
ENGINEERING DEPARTMENT
CITY OF CONCORD
P.O. BOX 308
CONCORD N.C. 28026
(704) 920-5425
Surveyor's Seal
NOTE:
1. DURING SEWER CONSTRUCTION,
CONTRACTOR TO MAINTAIN SEWER
SERVICE CONNECTIONS AT ALL TIMES
2. ALL EXISTING SERVICE CONNECTIONS TO
REMAIN IN SERVICE AND TO BE
PROTECTED DURING CONSTRUCTION.
CONTRACTOR SHALL LOCATE AND MAKE
PROVISIONS IN ACCORDANCE WITH CITY
OF CONCORD STANDARDS FOR
PROTECTION.
3. PROPOSED MANHOLE TO BE BUILT FOR
TEMPORARY SITUATION. AFTER
PERMANENT SEWER LINE HAS BEEN BUILT
ON TOP OF CULVERT, CONTRACTOR TO
ABANDON BOTTOM PART OF MANHOLE BY
FILLING WITH #57 STONE, REMOVING
INSIDE DROP, POURING NEW MANHOLE
BOTTOM SLAB FOR NEW PERMANENT INV
OUT AND CREATING A NEW TROUGH.
1.800.331.0008
1.800.252.1133
704.920.3000
704.920.5555
704.920.5555
704.392.8610
1.800.232.0144
1.800.769.3766
704.986.3700 Stanly Co Comm
1.800.632.4949
1.800.453.2530
N/A
1.800.752.7504
1.800.510.5678
1.877.776.2427
1.888.723.8010
704.378.2626 Option 5, 2, 1
1.800.922.6840
1.800.632.4949 NC One Call
704.788.4164 RRWWTP
1.800.800.6609
Engineer's Seal
2:1
630
629
628
628
627
626
627
628
626
628 6316:13:1
2:1
2:1
2:
1 CHADBOURNE AVECULVERT REPLACEMENTWATER MAIN PLANPROJECT # : 2017-026PREPARED BY
ENGINEERING DEPARTMENT
CITY OF CONCORD
P.O. BOX 308
CONCORD N.C. 28026
(704) 920-5425
Surveyor's Seal
PROPOSED
1-6" G.V. W/ VALVE BOX
STA:0+01.00
PROPOSED
1 CONC. ANCHOR BLOCK
STA:0+00.00
NOTE WATER LINE CROSSING SAN. SEWER LINE
WATER LINE INV ELEV: 624.00
SAN. SEWER INV ELEV: 615.36
STA:0+31.65
NOTE:
CONTRACTOR TO FIELD LOCATE EX. GAS LINE AND EX. SANITARY
SEWER MAIN. CONTRACTOR TO MAINTAIN MIN. OF AT LEAST 1
FOOT VERTICAL SEPARATION BETWEEN EXISTING UTILITIES AND
PROPOSED WATER MAIN.
NOTE:
NATURAL GAS LINE CROSSING WATER LINE
STA:0+22.12
NOTE:
CONTRACTOR TO FIELD LOCATE EX. GAS LINE
AND EX. SANITARY SEWER MAIN.
CONTRACTOR TO MAINTAIN MIN. OF AT LEAST
1 FOOT VERTICAL SEPARATION BETWEEN
EXISTING UTILITIES AND PROPOSED WATER
MAIN
PROPOSED
1-6" G.V. W/ VALVE BOX
STA:1+00.00
PROPOSED
101' of 6" RESTRAINED DI FIRE WATER MAIN,
PROPOSED LINE IS TO BE INSTALLED ONLY AFTER
CONSTRUCTION OF PROPOSED CULVERT IS
COMPLETED.
PROPOSED
1 CONC. ANCHOR BLOCK
STA:1+01.00
NOTE:
1. ALL PROPOSED WATER MAIN TO HAVE
RESTRAINED JOINTS.
2. PROPOSED WATER LINE LENGTH IS
APPROXIMATE, ACTUAL LENGTH AND
LOCATION TO BE DETERMINED IN THE
FIELD.
3. ALL EXISTING SERVICE CONNECTION TO
REMAIN IN SERVICE AND TO BE
PROTECTED DURING CONSTRUCTION.
CONTRACTOR SHALL LOCATE AND MAKE
PROVISIONS IN ACCORDANCE CITY OF
CONCORD STANDARDS FOR PROTECTION.
PROP.
1-F.H. ASSEMBLY
1-6" G.V.
1-6"x6" TEE
STA:0+07.00
PROPOSED
1-22 1
2° BEND
STA:0+50.80
REMOVE EXISTING F.H.
ASSEMBLY
REMOVE EXISTING
GATE VALVE
REMOVE 100' OF
EXISTING 6" FIRE
WATER MAIN
1.800.331.0008
1.800.252.1133
704.920.3000
704.920.5555
704.920.5555
704.392.8610
1.800.232.0144
1.800.769.3766
704.986.3700 Stanly Co Comm
1.800.632.4949
1.800.453.2530
N/A
1.800.752.7504
1.800.510.5678
1.877.776.2427
1.888.723.8010
704.378.2626 Option 5, 2, 1
1.800.922.6840
1.800.632.4949 NC One Call
704.788.4164 RRWWTP
1.800.800.6609
NOTE WATER LINE CROSSING SAN.
SEWER LINE
WATER LINE INV ELEV: 624.00
SAN. SEWER INV ELEV: 615.34
STA:0+31.00, OFF 5.20'R
NOTE:
CONTRACTOR TO FIELD LOCATE EX. GAS
LINE AND EX. SANITARY SEWER MAIN.
CONTRACTOR TO MAINTAIN MIN. OF AT
LEAST 1 FOOT VERTICAL SEPARATION
BETWEEN EXISTING UTILITIES AND
PROPOSED WATER MAIN.
PROPOSED
1-4" G.V. W/ VALVE BOX
STA:0+01.00, OFF:6.30'R
PROPOSED
1 CONC. ANCHOR BLOCK
STA:0+00.00, OFF:6.40'R
PROPOSED
1-4" G.V. W/ VALVE BOX
STA:1+00.00, OFF:3.45'R
PROPOSED
1 CONC. ANCHOR BLOCK
STA:1+01.00, OFF:3.55'R
PROPOSED
1-22 1
2° BEND
STA:0+51.00,
OFF:4.20'R
NOTE:
NATURAL GAS LINE CROSSING WATER LINE
STA:0+22.00, OFF:5.80'R
NOTE:
CONTRACTOR TO FIELD LOCATE EX. GAS LINE
AND EX. SANITARY SEWER MAIN.
CONTRACTOR TO MAINTAIN MIN. OF AT LEAST
1 FOOT VERTICAL SEPARATION BETWEEN
EXISTING UTILITIES AND PROPOSED WATER
MAIN
PROPOSED
101' of 4" RESTRAINED DI WATER MAIN, PROPOSED
LINE IS TO BE INSTALLED ONLY AFTER
CONSTRUCTION OF PROPOSED CULVERT IS
COMPLETED. SIZE TO BE VERIFIED PRIOR TO
INSTALLATION. CONTRACTOR TO MAKE
ARRANGEMENTS WITH "CAROLINA WATER SERVICE
OF NC" FOR WATERLINE REPLACEMENT.
REMOVE 100' OF
EXISTING 4" PRIVTE
WATER MAIN
Engineer's Seal
Surveyor's Seal
PREPARED BY
ENGINEERING DEPARTMENT
CITY OF CONCORD
P.O. BOX 308
CONCORD N.C. 28026
(704) 920-5425
CHADBOURNE AVECULVERT REPLACEMENTEROSION CONTROL DETAILSPROJECT # : 2017-02612. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING AN EROSION AND SEDIMENTATION
PERMIT FROM THE NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL
RESOURCES FOR ANY NEW OFF-SITE BORROW AREA. ANY OFF-SITE BORROW AND
WASTE REQUIRED FOR THIS PROJECT MUST COME FROM AN APPROVED EROSION CONTROL
PLAN SITE, A SITE REGULATED UNDER THE MINING ACT OF 1971, OR A
LANDFILL REGULATED BY THE DIVISION OF SOLID WASTE MANAGEMENT.
DEBRIS FROM DEMOLITION ACTIVITIES SHOULD BE DISPOSED OF AT AN APPROVED
FACILITY.
”
·
·
·
·
·
·
·
SOIL STABILIZATION TIME FRAMES
·
·
·
STEEL POST
FRONT VIEWSIDE VIEW2'-0"3'-0"VARIABLE AS DIRECTED BY THE ENGINEER
10' MAX.
GRADE
ORANGE, UV RESISTANT
HIGH - TENSILE STRENGTH
POLY BARRICADE FABRIC (TYPICAL)
ORANGE, UV RESISTANT
HIGH - TENSILE STRENGTH
POLY BARRICADE FABRIC (TYPICAL)
PLASTIC OR
WIRE TIES
Engineer's Seal
Surveyor's Seal
PREPARED BY
ENGINEERING DEPARTMENT
CITY OF CONCORD
P.O. BOX 308
CONCORD N.C. 28026
(704) 920-5425
CHADBOURNE AVE CULVERT REPLACEMENTCULVERT & PEDESTRIAN SAFETY RAILSTANDARD DETAILSPROJECT # : 2017-026NOTES:
1.CONSTRUCT PROPOSED STEEL PIPE RAIL OF 2” DIAMETER SCHEDULE 40 PLAIN END GALVANIZED STEEL PIPE
MEETING THE REQUIREMENTS OF ASTM A53.
2. REPAIR GALVANIZING IN ACCORDANCE WITH SECTION 1076 OF THE NCDOT STANDARD SPECIFICATIONS.
3. WHEN PAINTING IS REQUIRED IN THE PLANS, SMOOTH, CLEAN AND PREPARE GALVANIZED SURFACES IN
ACCORDANCE WITH SECTION 1080 AND THE ASTM D6386 STANDARD.
4. WELD IN ACCORDANCE WITH ARTICLE 1072-18 OF THE STANDARD.
5. VERTICAL POSTS TO BE EVENLY SPACED.
6. CONTRACTOR SHALL HAVE SAFETY RAIL CONNECTIONS DESIGNED, DETAILED AND SPECIFIED BY THE
HEADWALLS/WINGWALLS MANUFACTURER OR MANUFACTURER'S REPRESENTATIVE LICENSED IN THE STATE
OF NORTH CAROLINA. DESIGN MUST MEET LOADING REQUIREMENTS IN OSHA STANDARD 1910.29(B)(3) AND
1910.29(B)(5). CONTRACTOR SHALL SUBMIT FINAL DESIGN AND CALCULATIONS TO THE CITY OF CONCORD FOR
APPROVAL.
PEDESTRIAN SAFETY RAIL
Engineer's Seal
PREPARED BY
ENGINEERING DEPARTMENT
CITY OF CONCORD
P.O. BOX 308
CONCORD N.C. 28026
(704) 920-5425
Surveyor's Seal
CHADBOURNE AVECULVERT REPLACEMENTSTANDARD SANITARY SEWER DETAILSPROJECT # : 2017-026INSIDE DROP MANHOLE
WITH DROP BOWL
PRECAST CONCRETE
MANHOLE
SANITARY SEWER LATERAL
INSTALLATION ON
PROPOSED SEWER MAINREPLACEMENT
UTILITY CUT
Engineer's Seal
Surveyor's Seal
PREPARED BY
ENGINEERING DEPARTMENT
CITY OF CONCORD
P.O. BOX 308
CONCORD N.C. 28026
(704) 920-5425
CHADBOURNE AVECULVERT REPLACEMENTSTANDARD WATER DETAILSPROJECT # : 2017-026TYPICAL
ANCHOR BLOCK
TEMPORARY
JUMPER CONNECTION
TYPICAL
THRUST BLOCK
TYPICAL
VALVE BOX
Engineer's Seal
CHADBOURNE CULVERT
REPLACEMENT
TRAFFIC CONTROL PLAN
PROJECT # : 2017-026 PREPARED BYENGINEERING DEPARTMENTCITY OF CONCORDP.O. BOX 308CONCORD N.C. 28026(704) 920-5425Surveyor's SealTRAFFIC CONTROL NOTES1. THE CONTRACTOR SHALL MAINTAIN THE TRAFFIC CONTROL ASDESCRIBED HEREIN UNLESS THE CONTRACTOR SUBMITS ANALTERNATE TRAFFIC CONTROL PLAN TO THE CITY OF CONCORDENGINEER OR THEIR DESIGNEE MAY DIRECT THE CONTRACTOR TOMODIFY TRAFFIC CONTROL IF, IN THE ENGINEER'S OPINION, TRAFFICIS NOT MOVING SAFELY OR EFFICIENTLY.2. THE CONTRACTOR WILL BE REQUIRED TO MAINTAIN INGRESS ANDEGRESS TO ALL BUSINESSES AND DWELLINGS, AND EASY ACCESS TOFIRE HYDRANTS.3. POSITION WING BARRICADES ON SHOULDERS AND SLOPE THESTRIPES DOWNWARD IN THE DIRECTION TOWARD WHICH TRAFFICMUST TURN IN DETOURING.LEGENDCLOSEDDETOURCONESDETOUR FOR NORTH & SOUTH BOUNDROAD
CLOSED
R11-2 + ROADCLOSEDROAD CLOSEDTOTHRU TRAFFICR11-460"x30"TYPE III WINGBARRICADE48"x30"48"x30"TYPE III
BARRICADE R11-2 + TYPE IIIBARRICADEROADCLOSEDAHEAD30"x30"ROADCLOSEDAHEAD30"x30"ROAD CLOSEDTOTHRU TRAFFICR11-460"x30"TYPE III WINGBARRICADEEngineer's Seal