HomeMy WebLinkAboutWQCS00343_Compliance Evaluation Inspection_20180830K"
Water Resources
Environmental Quality
August 30, 2018
CERTIFIED MAIL #7015 1520 0002 8376 2029
RETURN RECEIPT REQUESTED
Douglas R. Linn, Town Manager
Town of Landis
P.O. Box 8165
Landis, North Carolina 28088
Subject: Compliance Evaluation Inspection & Notice of Violation
Case # NOV-2018-PC-0359
Permittee: Landis Collection System
Permit No. WQCS00343
Rowan County
Dear Mr. Linn:
ROY COOPER
Governor
MICHAEL S. REGAN
Secretary
LINDA CULPEPPER
Interim Director
Mr. Barry Love of the Mooresville Regional Office of the NC Division of Water Resources
(DWR or the Division) conducted a compliance evaluation inspection (CEI) of the Landis
wastewater collection system (WWCS) on August 22, 2018. The assistance of Mr. Chris
Ritchie during the inspection was greatly appreciated. A copy of the inspection report is
attached for your records and inspection findings are summarized below.
Site/System Review
2. The following system components were inspected:
a. Four pump stations were inspected.
b. Five manholes were inspected.
C. Two right of ways were inspected.
d. Four aerials were inspected.
3. As you are aware, owners of permitted collection systems must comply with their permit
and all rules listed under NC Administrative Code 15A NCAC 02T .0400, et seq. Landis'
compliance status with each of these rules is summarized below:
a. 15A NCAC 02T .0403(a)(1): Requires that the system be effectively maintained
and operated at all times to prevent discharge to land or surface waters and any
contravention of ground or surface water standards.
{'Nothing Compares7_.
State of North Carolina I Environmental Quality I Water Resources I Water Quality Regional Operations
Mooresville Regional Office 1610 East Center Avenue, Suite 3011 Mooresville, North Carolina 28115
704-663-1699
Observations: No SSO's have been reported for the system in the past couple of
years. The Fifth Street pump station visual alarm did not work; only the panel light
worked. This was noted as an issue at some pump stations in the previous
inspection (May 11, 2016) also. Maintaining visual alarms is considered proper
operation and maintenance of the system. High water audio and visual alarms are
also specifically required by 15A NCAC 02T .0305(h)(1)(F).
Compliance Status: Non -Compliant
b. 15A NCAC 02T .0403(a)(2): Requires that a map of the wastewater collection
system be developed and actively maintained.
Observations: The town has a paper map showing locations of lines, direction
of flow, force mains, pump stations, manholes and other information.
Computer/GIS based maps are currently being developed for the system. A paper
copy of this was viewed. These maps will have much more detail and thorough
information.
Compliance Status: Compliant
15A NCAC 02T .0403(a)(3): Requires that an operation and maintenance (O&M)
plan be developed and implemented, which includes pump station inspection
frequency, preventative maintenance schedule, spare parts inventory and overflow
response.
Observations: Protocol was set up to address most needs, but complete records
were not available to show that these things are being implemented. Pump station
logs were available, but only showed limited visits to the pump stations. Cummins
does routine maintenance on the onsite generators, but records were lacking for the
other generators. There was an inventory of equipment but not spare parts. The
overflow response plan was very thorough.
Compliance Status: Non -Compliant
d. 15A NCAC 02T .0403(a)(4): Requires that the permittee or its representative
inspect pump stations that are not connected to a telemetry system (i.e., remote
alarm system) every day (i.e., 365 days per year) and pump stations that are
connected to a telemetry system at least once per week.
Observations: The pump station inspection logs indicate that the pump stations
are not visited weekly as required. Many months show only one or two visits, but
some are more complete and do show weekly visits. Some of the pump stations are
visited daily since the high-water alarms are not connected to the telemetry system.
Compliance Status: Non -Compliant
e. 15A NCAC 02T .0403(a)(5): Requires that the permittee or its representative
inspect high-priority sewers (HPS - as defined in 15A NCAC 02T .0402(2)) at least
once every six months and document the inspections.
Observations: High-priority sewers appear to be checked every six months as
required.
Compliance Status: Compliant
f. 15A NCAC 02T .0403(a)(6): Requires that the permittee or its representative
conduct a general observation of the entire wastewater collection system at least
once per year.
Observations: The entire system is being observed through pump station
inspections, right of way inspections/mowing, line cleaning, and other routine
maintenance. Recently the whole southeast basin has been jetted, camera'ed, and
smoked. The system has also been observed through mapping recently.
Compliance Status: Compliant.
g. 15A NCAC 02T .0403(a)(7): Requires that overflows and bypasses from the
system be reported to the Division's Mooresville Regional Office in accordance
with 15A NCAC 02B .0506(a), and that public notice must be provided as required
by G. S. 143-215.1C.
Observations: No SSO's have been reported with this system over the past two
years, but records are available for previous spills. The NC regulations and statutes,
which cover the reporting requirements for SSOs, are found in NC Administrative
Code 15A NCAC 02B .0506(a) and NC General Statute 143-215.1C, respectively.
You may access the NC regulations online at the NC Office of Administrative
Hearings (OAH) website at: http://www.oah.state.nc.us/rules/ and the NC General
Statutes online at the NC General Assembly's website at:
http://www.ncga.state.nc.us/ ag scripts/Statutes/StatutesTOC.Pl. You may wish to
review them to ensure you are fully familiar with all requirements.
When reporting SSOs to DWQ, you must call the Mooresville Regional Office
(MRO) at 704-663-1699 during normal business hours. If outside normal business
hours, you must report the spill to the NC Division of Emergency Management at
1-800-858-0368. Please note that all reportable SSOs must be reported within 24
hours of the occurrence, or first knowledge, of the SSO. Please also note that voice
mail or faxed messages are not considered as the initial verbal report. You must
talk to and report the spill to a live person.
Compliance Status: Compliant
h. 15A NCAC 02T .0403(a)(8): Requires that a grease control program be developed
and implemented as follows:
For publicly owned collection systems, the Grease Control Program shall
include at least bi-annual distribution of grease education materials to users
and the legal means to require grease interceptors. The Program shall also
include legal means for inspections, enforcement, and legal means to
control grease entering the system from other public and private satellite
sewer systems.
2. Grease education materials shall be distributed more often than required
above if necessary to prevent grease -related sanitary sewer overflows.
Observations: Landis sends out a consumer confidence report to all users every
year which contains grease education. Pamphlets are also available at the town
hall, YMCA, and library, and information is posted on their website. The Town
has legal means to control grease going to their sewer.
Compliance Status: Compliant.
i. 15A NCAC 02T .0403(a)(9): Requires that right-of-ways (ROW) and easements
be maintained in the full easement width for personnel and equipment accessibility.
Observations: There were no records documenting ROW maintenance, but the
right-of-ways inspected were maintained to provide accessibility.
Compliance Status: Compliant.
15A NCAC 02T .0403(a)(10): Requires that documentation be kept for all
activities you undertake to comply with the requirements of 15A NCAC 02T.0403,
subparagraphs (a)(1) through (a)(9), for a minimum of three years, with the
exception of the map, which shall be maintained for the life of the system.
Observations: Records were not available for all activities.
Compliance Status: Non -Compliant
4. In accordance with NC General Statute 143-215.6A, these violations are subject to civil
penalty assessments not to exceed $25,000 per day, per violation. Your written response
and the actions that you take to address these violations listed herein will be considered in
deciding whether or not such penalties are necessary to compel compliance.
5. Corrective actions that should be taken for the above violations are as follows:
a. Documentation that pump stations that are connected to telemetry are inspected
once a week.
b. Documentation of right of way maintenance.
c. All visual alarms need to be made functional.
It is requested that a written response be submitted by no later than October 1, 2018
regarding these violations. Also, please take note of the comments in the inspection report
for other issues that may need to be addressed. The inspection report should be self-
explanatory; however, if you have any questions regarding the inspection report or this
letter please give me or Barry Love a call at 704-663-1699.
Sincerely,
DocuSigned by:
A14CC681 AF27425...
W. Corey Basinger, Regional Supervisor
Mooresville Regional Office
Water Quality Regional Operations Section
Division of Water Resources, NCDEQ
Attachments:
BIMS Inspection Report
CC: MRO
Central Files
PERCS Unit (e -copy)
Compliance Inspection Report
Permit: WQCS00343 Effective: 11/01/16 Expiration: 10/31/24 owner: Town of Landis
SOC: Effective: Expiration: Facility: Landis Collection System
County: Rowan 704 W Blume St
Region: Mooresville
Contact Person: Christopher E Ritchie Title: ORC Phone: 704-857-0131
Directions to Facility:
System Classifications: CS2,
Primary ORC: Christopher E Ritchie
Secondary ORC(s):
On -Site Representative(s):
Certification: 989864 Phone: 704-796-3526
Related Permits:
WQCS00019 City of Salisbury - Salisbury Collection System
NC0023884 City of Salisbury - City of Salisbury WWTP
Inspection Date: 08/22/2018 EntryTime: 10:OOAM
DocuSigned by:
Primary Inspector: Barry F Love
1B" .4ove-
Secondary Inspector(s): C7CCC7F740654B2...
Exit Time: 03:OOPM
Phone: 704-663-1699 Ext.263
Reason for Inspection: Routine Inspection Type: Collection System Inspect Non Sampling
Permit Inspection Type: Collection system management and operation
Facility Status: ❑ Compliant Not Compliant
Question Areas:
Miscellaneous Questions Performance Standards Operation & Maint Reqmts
Records Monitoring & Rpting Reqmts Inspections
Pump Station Manhole Lines
(See attachment summary)
DocuSigned by:
eyj 8/30/2018
A14CC681AF27425...
Page: 1
Permit: WQCS00343 Owner - Facility: Town of Landis
Inspection Date: 08/22/2018 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine
Inspection Summary:
Page: 2
Permit: WQCS00343 Owner - Facility: Town of Landis
Inspection Date: 08/22/2018 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine
Performance Standards Yes No NA NE
Is Public Education Program for grease established and documented? 0 ❑ ❑ ❑
What educational tools are used?
Grease education is included on the town's consumer confidence report which goes out to all customers
annually. Pamphlets are available at the town hall, YMCA, and Library. Information is available on their web
site, with the link to their site included in the monthly bills.
Is Sewer Use Ordinance/Legal Authority available? ❑ ❑ ❑
Does it appear that the Sewer Use Ordinance is enforced? ❑ ❑ ❑
Is Grease Trap Ordinance available? ❑ ❑ ❑
Is Septic Tank Ordinance available (as applicable, i.e. annexation) ❑ ❑ ❑
List enforcement actions by permittee, if any, in the last 12 months
Has an acceptable Capital Improvement Plan (CIP) been implemented?
❑ ❑ ❑
Does CIP address short term needs and long term \"master plan\" concepts?
❑ ❑ ❑
Does CIP cover three to five year period?
❑ ❑ ❑
Does CIP include Goal Statement?
❑ ❑ ❑
Does CIP include description of project area?
❑ ❑ ❑
Does CIP include description of existing facilities?
❑ ❑ ❑
Does CIP include known deficiencies?
❑ ❑ ❑
Does CIP include forecasted future needs?
❑ ❑ ❑
Is CIP designated only for wastewater collection and treatment?
❑ ❑ ❑
Approximate capital improvement budget for collection system?
Total annual revenue for wastewater collection and treatment?
CIP Comments
The current CIP is almost ten years old and about to run out. The town intends to complete a new 5 year CIP
once the current ongoing GIS mapping project is completed.
Is system free of known points of bypass?
❑ ❑ ❑
If no, describe type of bypass and location
Is a 24-hour notification sign posted at ALL pump stations?
❑ ❑ ❑
# Does the sign include:
Instructions for notification?
❑ ❑ ❑
Pump station identifier?
❑ ❑ ❑
24-hour contact numbers
❑ ❑ ❑
If no, list deficient pump stations
# Do ALL pump stations have an "auto polling" feature/SCADA?
❑
❑ ❑
Number of pump stations
10
Number of pump stations that have SCADA
0
Number of pump stations that have simple telemetry
10
Page: 3
Permit: WQCS00343 Owner - Facility: Town of Landis
Inspection Date: 08/22/2018 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine
Number of pump stations that have only audible and visual alarms 10
Number of pump stations that do not meet permit requirements
# Does the permittee have a root control program? ❑ ❑ ❑
# If yes, date implemented?
Describe:
Comment: The town has a grease ordinance, but hasn't checked these systems. There are only a couple
of restaurants and they haven't had any troubles in regard to these.
Inspections
Yes No NA NE
Are maintenance records for sewer lines available?
❑ ❑ ❑
Are records available that document pump station inspections?
❑ ❑ ❑
Are SCADA or telemetry equipped pump stations inspected at least once a week?
❑
❑ ❑
Are non-SCADA/telemetry equipped pump stations inspected every day?
❑ ❑ ❑
Are records available that document citizen complaints?
❑ ❑ ❑
# Do you have a system to conduct an annual observation of entire system?
❑
❑ ❑
# Has there been an observation of remote areas in the last year?
❑
❑ ❑
Are records available that document inspections of high-priority lines?
❑ ❑ ❑
Has there been visual inspections of high-priority lines in last six months?
❑ ❑ ❑
Comment: Pump station inspection records were very limited. Most records showed only one or two
inspections Der month with almost no information to document if anvthina was checked. Some
more thorough records were started must before the inspection. The operator stated that all lines
are checked during mowing and weedeating, but no records were available. Records were
available documenting high priority line inspections.
Operation & Maintenance Requirements Yes No NA NE
Are all log books available? ❑ ❑ ❑
Does supervisor review all log books on a regular basis? ❑ ❑ ❑
Does the supervisor have plans to address documented short-term problem areas? ❑ ❑ ❑
What is the schedule for reviewing inspection, maintenance, & operations logs and problem areas?
Pump station inspection logs were apparently not reviewed.
Are maintenance records for equipment available?
Is a schedule maintained for testing emergency/standby equipment?
What is the schedule for testing emergency/standby equipment?
Do pump station logs include:
Inside and outside cleaning and debris removal?
Inspecting and exercising all valves?
Inspecting and lubricating pumps and other equipment?
Inspecting alarms, telemetry and auxiliary equipment?
Is there at least one spare pump for each pump station w/o pump reliability?
❑ ❑ ❑
❑ ❑ ❑
weekly for onsite
generators
❑■❑❑
❑■❑❑
❑■❑❑
❑■❑❑
❑❑■❑
Page: 4
Permit: WQCS00343 Owner - Facility: Town of Landis
❑ ❑ ❑
Inspection Date: 08/22/2018 Inspection Type : Collection System Inspect Non Sampling Reason for Visit:
Routine
Are maintenance records for right-of-ways available?
❑
0 ❑ ❑
Are right-of-ways currently accessible in the event of an emergency?
Flow direction
❑ ❑ ❑
Are system cleaning records available?
Approximate pipe age
❑ ❑ ❑
Has at least 10% of system been cleaned annually?
Number of service taps
❑ ❑ ❑
What areas are scheduled for cleaning in the next 12 months?
Pump stations and capacity
Is a Spill Response Action Plan available?
0
❑ ❑ ❑
Does the plan include:
List any modifications and extensions that need to be added to the map
24-hour contact numbers
❑ ❑ ❑
Response time
❑ ❑ ❑
Equipment list and spare parts inventory
❑ ❑ ❑
Access to cleaning equipment
❑ ❑ ❑
Access to construction crews, contractors, and/or engineers
❑ ❑ ❑
Source of emergency funds
❑
❑ ❑
Site sanitation and cleanup materials
❑ ❑ ❑
Post-overflow/spill assessment
❑ ❑ ❑
Is a Spill Response Action Plan available for all personnel?
❑
❑ ❑ 0
Is the spare parts inventory adequate?
❑
❑ ❑ 0
Comment: Cummins maintains onsite generators. Onsite generators are set to run for 30 minutes every
Thursday. The town has two portable generators. Its not clear when these are tested.
Pump station records contained veru little information, except for some done in the past couple
of weeks. Maintenance records of right of ways were not available.
Records Yes No NA NE
Are adequate records of all SSOs, spills and complaints available? 0 ❑ ❑ ❑
Are records of SSOs that are under the reportable threshold available? ❑ ❑ ❑
Do spill records indicate repeated overflows (2 or more in 12 months) at same location? ❑ ❑ ❑
If yes, is there a corrective action plan? ❑ ❑ ❑
Is a map of the system available? ❑ ❑ ❑
Does the map include:
Pipe sizes
❑ ❑ ❑
Pipe materials
❑ ❑ ❑
Pipe location
❑ ❑ ❑
Flow direction
❑ ❑ ❑
Approximate pipe age
❑
❑ ❑
Number of service taps
❑ ❑ ❑
Pump stations and capacity
❑ ❑ ❑
If no, what percent is complete?
List any modifications and extensions that need to be added to the map
Page: 5
Permit: WQCS00343 Owner - Facility: Town of Landis
Inspection Date: 08/22/2018 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine
# Does the permittee have a copy of their permit?
Comment: Paper maps were available, and a new GIS based map system is being developed to be
completed by next summer.
No SSO's have been reported in the past couple of years with the last occurring in Oct. 2015.
■❑❑❑
Monitoring and Reporting Requirements Yes No NA NE
Are copies of required press releases and distribution lists available? ❑ 1:10 ❑
Are public notices and proof of publication available? ❑ ❑ M ❑
# Is an annual report being prepared in accordance with G.S. 143-215.1 C? 0 ❑ ❑ ❑
# Is permittee compliant with all compliance schedules in the permits? ❑ ❑ 0 ❑
If no, which one(s)?
Comment: A copy of the annual report was available.
UPRIGHT - 1st upstream of
Manhole
Yes
No NA NE
Is manhole accessible?
0
❑ ❑ ❑
# Is manhole cover/vent above grade?
❑
❑ ❑
Is the manhole free of visible signs of overflow?
❑ ❑ ❑
❑ ❑ ❑
Is the manhole free of sinkholes and depressions?
❑ ❑ ❑
❑ ❑ ❑
Is manhole cover present?
❑ ❑ ❑
❑ ❑ ❑
# Is manhole properly seated?
❑ ❑ ❑
# Is manhole in good condition?
0
❑ ❑ ❑
# Is invert in good condition?
❑ ❑ ❑
Is line free-flowing and unrestricted in manhole?
❑ ❑ ❑
Is manhole free of excessive amounts of grease?
❑ ❑ ❑
Is manhole free of excessive roots?
❑ ❑ ❑
Is manhole free of excessive sand?
❑ ❑ ❑
Is manhole's extended vent screened?
❑
❑ 0 ❑
Are vents free of submergence?
❑ ❑ ❑
Are manholes free of bypass structures or pipes?
❑ ❑ ❑
Comment: 8 -inch line free flowing with no problems observed
HIGHWAY 29 - 1st manhole
Manhole
Yes No NA NE
Is manhole accessible?
❑ ❑ ❑
# Is manhole cover/vent above grade?
❑ ❑ ❑
Is the manhole free of visible signs of overflow?
0
❑ ❑ ❑
Is the manhole free of sinkholes and depressions?
❑ ❑ ❑
Is manhole cover present?
❑ ❑ ❑
Page: 6
Permit: WQCS00343 Owner - Facility: Town of Landis
Inspection Date: 08/22/2018 Inspection Type : Collection System Inspect Non Sampling
Reason for Visit: Routine
# Is manhole properly seated?
0
❑ ❑ ❑
# Is manhole in good condition?
0
❑ ❑ ❑
# Is invert in good condition?
0
❑ ❑ ❑
Is line free-flowing and unrestricted in manhole?
❑ ❑ ❑
Is manhole free of excessive amounts of grease?
❑ ❑ ❑
Is manhole free of excessive roots?
0
❑ ❑ ❑
Is manhole free of excessive sand?
❑ ❑ ❑
Is manhole's extended vent screened?
❑
❑ ❑
Are vents free of submergence?
❑ ❑ ❑
Are manholes free of bypass structures or pipes?
❑ ❑ ❑
Comment: 8 -inch line free flowing with no problems observed.
PARTEE - 1st manhole upsi
Manhole
Yes No NA NE
Is manhole accessible?
❑ ❑ ❑
# Is manhole cover/vent above grade?
❑
❑ ❑
Is the manhole free of visible signs of overflow?
❑ ❑ ❑
Is the manhole free of sinkholes and depressions?
❑ ❑ ❑
Is manhole cover present?
0
❑ ❑ ❑
# Is manhole properly seated?
❑ ❑ ❑
# Is manhole in good condition?
❑ ❑ ❑
# Is invert in good condition?
❑ ❑ ❑
Is line free-flowing and unrestricted in manhole?
❑ ❑ ❑
Is manhole free of excessive amounts of grease?
❑ ❑ ❑
Is manhole free of excessive roots?
0
❑ ❑ ❑
Is manhole free of excessive sand?
❑ ❑ ❑
Is manhole's extended vent screened?
❑
❑ ❑
Are vents free of submergence?
❑ ❑ ❑
Are manholes free of bypass structures or pipes?
0
❑ ❑ ❑
Comment: Manhole is in street. 8 -inch line free flowing with no problems observed.
FIFTH STREET - 1st manhc
Manhole Yes No NA NE
Is manhole accessible? 0 1:11:1 ❑
# Is manhole cover/vent above grade? 0 ❑ ❑ ❑
Is the manhole free of visible signs of overflow? ❑ ❑ ❑
Is the manhole free of sinkholes and depressions? ❑ ❑ ❑
Is manhole cover present? 0 ❑ ❑ ❑
Page: 7
Permit: WQCS00343 Owner - Facility: Town of Landis
Inspection Date: 08/22/2018 Inspection Type : Collection System Inspect Non Sampling
Reason for Visit: Routine
# Is manhole properly seated?
0
❑ ❑ ❑
# Is manhole in good condition?
0
❑ ❑ ❑
# Is invert in good condition?
❑
❑ ❑ 0
Is line free-flowing and unrestricted in manhole?
❑
❑ ❑
Is manhole free of excessive amounts of grease?
❑
❑ ❑
Is manhole free of excessive roots?
0
❑ ❑ ❑
Is manhole free of excessive sand?
❑
❑ ❑
Is manhole's extended vent screened?
❑
❑ ❑
Are vents free of submergence?
❑ ❑ ❑
Are manholes free of bypass structures or pipes?
0
❑ ❑ ❑
Comment: Invert was not visible due to a large amount of suds in manhole.
❑ ❑ ❑
BLUME -
Pump Station
Manhole
Yes No NA NE
Is manhole accessible?
0
❑ ❑ ❑
# Is manhole cover/vent above grade?
0
❑ ❑ ❑
Is the manhole free of visible signs of overflow?
0
❑ ❑ ❑
Is the manhole free of sinkholes and depressions?
0
❑ ❑ ❑
Is manhole cover present?
0
❑ ❑ ❑
# Is manhole properly seated?
❑ ❑ ❑
# Is manhole in good condition?
❑ ❑ ❑
# Is invert in good condition?
❑ ❑ ❑
Is line free-flowing and unrestricted in manhole?
❑ ❑ ❑
Is manhole free of excessive amounts of grease?
❑ ❑ ❑
Is manhole free of excessive roots?
0
❑ ❑ ❑
Is manhole free of excessive sand?
❑ ❑ ❑
Is manhole's extended vent screened?
❑
❑ ❑
Are vents free of submergence?
❑ ❑ ❑
Are manholes free of bypass structures or pipes?
❑ ❑ ❑
Comment: 21 -inch line free flowing with no problems observed
LS # 9 PARTEE - 1213 Part
Pump Station
Yes No NA NE
Pump station type
Duplex
Are pump station logs available?
❑ ❑ ❑
Is it accessible in all weather conditions?
❑ ❑ ❑
# Is general housekeeping acceptable?
❑ ❑ ❑
Are all pumps present?
0 ❑ ❑ ❑
Page: 8
Permit: WQCS00343 Owner - Facility: Town of Landis
Inspection Date: 08/22/2018 Inspection Type : Collection System Inspect Non Sampling
Reason for Visit: Routine
Are all pumps operable?
0
❑ ❑ ❑
Are wet wells free of excessive debris?
0
❑ ❑ ❑
Are upstream manholes free of excessive debris/signs of overflow?
❑ ❑ ❑
Are floats/controls for pumps/alarms operable?
❑ ❑ ❑
Is "auto polling" feature/SCADA present?
❑
❑ ❑
Is "auto polling" feature/SCADA operational?
❑
❑ ❑
Is simple telemetry present?
❑ ❑ ❑
Is simple telemetry operational?
❑ ❑ ❑
Are audio and visual alarms present?
❑ ❑ ❑
Are audio and visual alarms operable?
❑ ❑ ❑
Is the Pump station inspected as required?
❑
❑ ❑
Are backflow devices in place?
❑
❑ ❑
Are backflow devices operable?
❑
❑ ❑
Are air relief valves in place?
❑
❑ ❑
Are air relief valves operable?
❑
❑ ❑
# Is an emergency generator available?
❑ ❑ ❑
Can the emergency generator run the pumps?
❑
❑ ❑
Is the pump station equipped for quick hook-up?
❑ ❑ ❑
Is the generator operable?
❑
❑ ❑
# Is fuel in tank and sufficient?
❑
❑ ❑
Is the generator inspected according to their schedule?
❑
❑ ❑
Is a 24-hour notification sign posted?
0
❑ ❑ ❑
Does it include:
Instructions for notification?
0
❑ ❑ ❑
Pump station identifier?
0
❑ ❑ ❑
Emergency phone number
❑ ❑ ❑
Is public access limited?
❑ ❑ ❑
Is pump station free of overflow piping?
❑ ❑ ❑
Is the pump station free of signs of overflow?
❑ ❑ ❑
Are run times comparable for multiple pumps?
Comment: The hiah water float was Dulled and the audible and visual alarms and telemetry all worked. A
moderate amount of grease was in the wet well. Inspection logs do not show that the pump
station is being inspected weekly as required. This pump station has a quick -connect, but it is
not compatible with their portable generator.
TOWN STREET AERIAL -
Lines/Right-of-Ways/Aeriel Lines
Is right-of-way accessible for emergency?
Yes No NA NE
❑❑■❑
Page: 9
Permit: WQCS00343 Owner - Facility: Town of Landis
Inspection Date: 08/22/2018 Inspection Type : Collection System Inspect Non Sampling Reason for Visit:
Routine
Is right-of-way free of sinkholes or depressions?
❑
❑ 0 ❑
Is line/right-of-way free of evidence of leakage?
❑
❑ ❑
# Are there areas of exposed line?
❑ ❑ ❑
# Is any exposed line constructed of ductile iron or other approved material?
❑ ❑ ❑
Are water crossing and supports in good condition?
❑ ❑ ❑
# Is right-of-way free of non-utility motorized traffic?
❑
❑ ❑
Is line free of visible damage?
❑
❑ ❑ ❑
# Are there siphons in this system?
❑
❑ ❑
If yes, are they maintained and documented?
❑ ❑ ❑
Comment: Two aerials immediately adjacent to road; one is gravity line, the other is force main. No
❑ ❑ ❑
problems observed.
❑
❑ ❑
LS # 6 FIFTH ST. - Fifth Str(
Pump Station
Yes No NA NE
Pump station type
Duplex
Are pump station logs available?
❑ ❑ ❑
Is it accessible in all weather conditions?
❑ ❑ ❑
# Is general housekeeping acceptable?
❑ ❑ ❑
Are all pumps present?
❑ ❑ ❑
Are all pumps operable?
❑
❑ ❑
Are wet wells free of excessive debris?
❑ ❑ ❑
Are upstream manholes free of excessive debris/signs of overflow?
❑ ❑ ❑
Are floats/controls for pumps/alarms operable?
❑ ❑ ❑
Is "auto polling" feature/SCADA present?
❑
❑ ❑
Is "auto polling" feature/SCADA operational?
❑
❑ ❑
Is simple telemetry present?
❑ ❑ ❑
Is simple telemetry operational?
❑ ❑ ❑
Are audio and visual alarms present?
❑ ❑ ❑
Are audio and visual alarms operable?
❑
❑ ❑
Is the Pump station inspected as required?
❑
❑ ❑
Are backflow devices in place?
❑
❑ ❑
Are backflow devices operable?
❑
❑ ❑
Are air relief valves in place?
❑
❑ ❑
Are air relief valves operable?
❑
❑ ❑
# Is an emergency generator available?
❑ ❑ ❑
Can the emergency generator run the pumps?
❑
❑ ❑
Is the pump station equipped for quick hook-up?
❑
❑ ❑
Page: 10
Permit: WQCS00343 Owner - Facility: Town of Landis
Inspection Date: 08/22/2018 Inspection Type : Collection System Inspect Non Sampling
Reason for Visit: Routine
Is the generator operable?
❑
❑ ❑ 0
# Is fuel in tank and sufficient?
❑
❑ ❑ 0
Is the generator inspected according to their schedule?
❑
❑ ❑ 0
Is a 24-hour notification sign posted?
0
❑ ❑ ❑
Does it include:
❑ ❑ ❑
Instructions for notification?
0
❑ ❑ ❑
Pump station identifier?
0
❑ ❑ ❑
Emergency phone number
❑
❑ ❑ ❑
Is public access limited?
❑ ❑ ❑
Is pump station free of overflow piping?
❑
❑ ❑ ❑
Is the pump station free of signs of overflow?
❑ ❑ ❑
Are run times comparable for multiple pumps?
Comment: The hiah water float was Dulled and the audible alarm and telemetry worked. The Danel liaht lit
up, but the larger alarm light didn't. This was noted as an issue at a couple of stations at the last
inspection also. Records didn't show that the pump station is inspected weekly as required.
The ORC said that one of the pumps at this station keeps losing prime, and they are trying to
resolve this issue.
CHAPEL ST. AERIAL -
Lines/Right-of-Ways/Aeriel Lines
Yes No NA NE
Is right-of-way accessible for emergency?
❑
❑ 0 ❑
Is right-of-way free of sinkholes or depressions?
❑
❑ ❑
Is line/right-of-way free of evidence of leakage?
❑ ❑ ❑
# Are there areas of exposed line?
❑ ❑ ❑
# Is any exposed line constructed of ductile iron or other approved material?
❑ ❑ ❑
Are water crossing and supports in good condition?
❑ ❑ ❑
# Is right-of-way free of non-utility motorized traffic?
❑
❑ ❑
Is line free of visible damage?
❑ ❑ ❑
# Are there siphons in this system?
❑
❑ ❑
If yes, are they maintained and documented?
Comment: Concrete supports. No problems observed
FOURTH ST. -
Lines/Right-of-Ways/Aeriel Lines
Yes No NA NE
Is right-of-way accessible for emergency?
❑ ❑ ❑
Is right-of-way free of sinkholes or depressions?
❑ ❑ ❑
Is line/right-of-way free of evidence of leakage?
❑ ❑ ❑
# Are there areas of exposed line?
❑ ❑ ❑
# Is any exposed line constructed of ductile iron or other approved material?
❑ ❑ ❑
Page: 11
Permit: WQCS00343 Owner - Facility: Town of Landis
Inspection Date: 08/22/2018 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine
Are water crossing and supports in good condition? 0 ❑ ❑ ❑
# Is right-of-way free of non-utility motorized traffic? 0 ❑ ❑ ❑
Is line free of visible damage? 0 ❑ ❑ ❑
# Are there siphons in this system? ❑ ❑ ❑ 0
If yes, are they maintained and documented?
Comment: Aerial is 10 -inch line in 16 -inch encasement with concrete supports. No problems were
observed.
LS #1 UPRIGHT - 610 S. UK
Pump Station
Yes No NA NE
Pump station type
Duplex
Are pump station logs available?
0
❑ ❑ ❑
Is it accessible in all weather conditions?
0
❑ ❑ ❑
# Is general housekeeping acceptable?
0
❑ ❑ ❑
Are all pumps present?
0
❑ ❑ ❑
Are all pumps operable?
0
❑ ❑ ❑
Are wet wells free of excessive debris?
0
❑ ❑ ❑
Are upstream manholes free of excessive debris/signs of overflow?
❑ ❑ ❑
Are floats/controls for pumps/alarms operable?
❑ ❑ ❑
Is "auto polling" feature/SCADA present?
❑
❑ ❑
Is "auto polling" feature/SCADA operational?
❑
❑ ❑
Is simple telemetry present?
❑ ❑ ❑
Is simple telemetry operational?
❑ ❑ ❑
Are audio and visual alarms present?
❑ ❑ ❑
Are audio and visual alarms operable?
❑ ❑ ❑
Is the Pump station inspected as required?
❑
❑ ❑
Are backflow devices in place?
❑
❑ ❑
Are backflow devices operable?
❑
❑ ❑
Are air relief valves in place?
❑
❑ ❑
Are air relief valves operable?
❑
❑ ❑
# Is an emergency generator available?
❑ ❑ ❑
Can the emergency generator run the pumps?
❑ ❑ ❑
Is the pump station equipped for quick hook-up?
❑
❑ ❑
Is the generator operable?
❑ ❑ ❑
# Is fuel in tank and sufficient?
❑ ❑ ❑
Is the generator inspected according to their schedule?
❑ ❑ ❑
Is a 24-hour notification sign posted?
❑ ❑ ❑
Page: 12
Permit: WQCS00343 Owner - Facility: Town of Landis
Inspection Date: 08/22/2018 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine
Does it include:
Instructions for notification? 0 ❑ ❑ ❑
Pump station identifier? 0 ❑ ❑ ❑
Emergency phone number ❑ ❑ ❑
Is public access limited? ❑ ❑ ❑
Is pump station free of overflow piping? ❑ ❑ ❑
Is the pump station free of signs of overflow? ❑ ❑ ❑
Are run times comparable for multiple pumps?
Comment: The high water float was pulled and the audible and visual alarms and telemetry all worked. The
power was shut off and the generator cranked. Records didn't show that it has been inspected
as required.
LS # 10, HIGHWAY 29 - 20
Pump Station
Yes No NA NE
Pump station type
Duplex
Are pump station logs available?
0
❑ ❑ ❑
Is it accessible in all weather conditions?
❑ ❑ ❑
# Is general housekeeping acceptable?
❑ ❑ ❑
Are all pumps present?
❑ ❑ ❑
Are all pumps operable?
❑ ❑ ❑
Are wet wells free of excessive debris?
❑ ❑ ❑
Are upstream manholes free of excessive debris/signs of overflow?
❑ ❑ ❑
Are floats/controls for pumps/alarms operable?
❑ ❑ ❑
Is "auto polling" feature/SCADA present?
❑
❑ ❑
Is "auto polling" feature/SCADA operational?
❑
❑ ❑
Is simple telemetry present?
❑ ❑ ❑
Is simple telemetry operational?
❑ ❑ ❑
Are audio and visual alarms present?
❑ ❑ ❑
Are audio and visual alarms operable?
❑ ❑ ❑
Is the Pump station inspected as required?
❑
❑ ❑
Are backflow devices in place?
❑
❑ ❑
Are backflow devices operable?
❑
❑ ❑
Are air relief valves in place?
❑
❑ ❑
Are air relief valves operable?
❑
❑ ❑
# Is an emergency generator available?
❑ ❑ ❑
Can the emergency generator run the pumps?
❑
❑ ❑
Is the pump station equipped for quick hook-up?
❑ ❑ ❑
Is the generator operable?
❑
❑ ❑ 0
Page: 13
Permit: WQCS00343
Owner - Facility: Town of Landis
Inspection Date: 08/22/2018
Inspection Type : Collection System Inspect Non Sampling Reason for Visit:
Routine
# Is fuel in tank and sufficient?
❑
❑ ❑ 0
Is the generator inspected according to their schedule?
❑
❑ ❑ 0
Is a 24-hour notification sign posted?
0
❑ ❑ ❑
Does it include:
Instructions for notification?
0
❑ ❑ ❑
Pump station identifier?
0
❑ ❑ ❑
Emergency phone number
❑ ❑ ❑
Is public access limited?
❑ ❑ ❑
Is pump station free of overflow piping?
❑ ❑ ❑
Is the pump station free of signs of overflow?
❑ ❑ ❑
Are run times comparable for multiple pumps?
Comment: The high water float was pulled
and the audible and visual alarms and telemetry all worked.
The
records didn't show weekly
visitation to the pump station. This station has a quick connect,
but it
isn't compatible with their
portable generator. They say their electrical quos can wire if needed.
BLUME ST. OUTFALL -
Lines/Right-of-Ways/Aeriel Lines Yes No NA NE
Is right-of-way accessible for emergency? ❑ ❑ ❑
Is right-of-way free of sinkholes or depressions? ❑ ❑ ❑
Is line/right-of-way free of evidence of leakage? ❑ ❑ ❑
# Are there areas of exposed line? ❑ ❑ ❑
# Is any exposed line constructed of ductile iron or other approved material? ❑ ❑ ❑
Are water crossing and supports in good condition? ❑ ❑ ❑
# Is right-of-way free of non-utility motorized traffic? ❑ ❑ ❑
Is line free of visible damage? ❑ ❑ ❑
# Are there siphons in this system? ❑ ❑ ❑ 0
If yes, are they maintained and documented?
Comment: This is a long aerial with approximately 10 supports. One support is in the stream channel and
appears to have been this way for a long time. No debris was on this support. The opposite
stream bank appeared to be very recently eroded, almost to the support on that side. This
should be closely monitored and addressed if necessary.
Page: 14