Loading...
HomeMy WebLinkAboutWQ0040161_Application_20180723ORSBORN ENGINEERING GROUP 610 EAST MOREHEAD STREET, SUITE 106 CHARLOTTE, NORTH CAROLINA 28202 PHONE 704.749.1432 FAx 704.749.1433 To: Fast Track Permitting NCDENR 610 E. Center Ave. Mooresville, NC 28115 (704)663-1699 Otv. Date TRANSMITTAL Project: 17045 Pineville Distribution Lot 6 RECEIVEDINCOENR/DWR Date: 07/17/2018 JUL. 18 2U18 WOROS Sent Via: FedEx MOORESVILLE REGIONAL OFFICE Descrintion 2 Applications 1 Fee $480 1 Flow Acceptance/Flow Tracking 1 USGS Quad Map 1 Cover Letter ® For Approval ❑ For Your Use ❑ As Requested Copied To: ❑ For Review and Comment ❑ Approved as Submitted ❑ Approved as Noted ❑ Returned for Corrections ❑ Returned After Review ❑ Resubmit for Approval Signed: Mackenzie Mc T ol, EI r(� ORSSORN ENGINEERING GROUP Pineville Distribution Lot 6 Pineville, North Carolina Project Narrative May 17, 2018 The overall development includes a new 33.5 acre lot containing a 525,000 sq. ft. warehouse with 75 loading docks. The public sewer system, maintained by Charlotte Water, will be extended along the southern edge of the lot and along the future Pineville Distribution Street. The building will drain to a private 8" collection system which connects to the new public sewer extension. State of North Carolina DWR Department of Environmental Quality Division of Water Resources 15A NCAC 02T.0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: WwQqu G/ (to be completed by DWR) All items must be completed or the application will be returned L APPLICANT INFORMATION: 1. Applicant's name: BIN -PDS LLC (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ® Corporation ❑ General Partnership ❑ Federal ❑ State/County ❑ Municipal 3. Signature authority's name: Sean McDonnell per 15A NCAC 02T .0106(b) Title: Manager 4. Applicant's mailing address: 500 E. Morehead Street Suite 200 City: Charlotte State: NC Zip: 28202 5. Applicant's contact information: Phone number: (704) 926-1416 Email Address: sean@beacondevelopment.com 11, PROJECT INFORMATION: ❑ Privately -Owned Public Utility ❑ Other RECEIVEDINCDENRIDWR JUL 18 1018 WOROS MOORESVILLE REGIONAL OFFICE 1. Project name: Pineville Distribution Lot 6 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project If modification, provide the existing permit number: W000_ and issued date: _ If new construction but part of a master plan, provide the existing permit number: W000 3. County where project is located: Mecklenburg 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.105°Longitude: -80.883° 5. Parcel ID (if applicable): 20507112 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: Jeffery C. Orsborn License Number: 028786 Firm: Orsborn Engineering Group, PA Mailing address: 610 E Morehead St., Suite 106 City: Charlotte State: NC Zip: 28202-2614 Phone number: (704) 749-1432 Email Address: iorsbornAorsborn-eng.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: McAlpine Creek W WTP Permit Number: NCO024970 Owner Name: CLTWater(CMUD) V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQUnknown Downstream (Receiving) Sewer Size: 8 inch System Wide Collection System Permit Number(s) (if applicable): WQCS_ OwnerName(s): CLTWater(CMUD) FORM: FTA 04-16 Pagel of 5 VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑No MN/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Aereement (FORM: DEVI been attached? ❑ Yes ❑No NN/A 3. If the Applicant is a Home/Property Owners' Association, has an Operational Aereement (FORM: HOA) been attached? ❑ Yes ❑No MN/A 4. Origin of wastewater: (check all that apply): ❑ Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool /Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash M Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: %Domestic/Commercial %Commercial 100 % Industrial (See 15A NCAC 02T .0103(20)) "Is there a Pretreatment Program in effect? ❑ Yes M No 6. Has a flow reduction been approved under 15A NCAC 02T.0 I 14(f)? ❑ Yes M No ➢ If yes, provide a copy of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see 02T.01 14(f)) Daily Design Flow 2,b No. of Units Flow Warehouse 100 gal/loading bay 75 7,500 GPD Office 25 gal/employee 20 500 GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total 8,000 GPD a See 15A NCAC 02T.01 14(b), (d), (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01 141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 8 000 GPD (per 15A NCAC 02T .0114) Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 VIL GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T.0305 & MDC (Gravity Sewers): I. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8" 1035' PVC ➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) —_22T.0305 & MDC (Puma Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: -, 3. Design flow of the pump station: millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): _ gallons per minute at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B): ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS —(02B.0200 & 15A NCAC 02T.0305(0): 1. Does the project comply with all separations found in 15A NCAC 02T .0305(0 & (1z) ➢ 15A NCAC 02T.0305 contains minimum separations that shall be provided for sewers stems: ® Yes ❑ No Setback Parameter* Separation Required Storm sewers and other utilities not listed below vertical 24 inches Water mains vertical -water over sewer includingin benched trenches 18 inches Water mains horizontal 10 feet Reclaimed water lines vertical - reclaimed over sewer 18 inches Reclaimed water lines horizontal - reclaimed over sewer 2 feet **Any private or public water supply source, including any wells, WS -1 waters of Class I or Class 11 impounded reservoirs used as a source of drinking water 100 feet "Waters classified WS (except WS -1 or WS -V), B, SA, ORW, HQW, or SB from normal high water or tide elevation and wetlands see item IX.2 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches ➢ 15A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305(f) cannot be achieved. ➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications weboage ➢ If noncompliance with 02T.0305(f) or (g), see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ® Yes [:]No ➢ See the Division's draft separation requirements for situations where separation cannot be meet ➢ No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with all setbacks found in the river basin rules per 15A NCAC 02B .0200? ® Yes ❑ No ➢ This would include Trout Buffered Streams per 15A NCAC 28.0202 4. Does the project comply with an individual 404 Permit or any 401 Certifications? ® Yes []No ➢ Wetland -related permits shall be requested, obtained, and adhered to for projects that impact wetlands or surface waters ➢ Information can be obtained from the 401 & Buffer Permitting Branch 5. Does proj6ct comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes ❑ No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high-priority?" Per 15A NCAC 02T.04021 "high-priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. []Yes ® No ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria (latest version) as applicable? ® Yes ❑ No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. _Approval of the request is required prior to submittal of the Fast Track Application and supporting documents. 2. Professional Engineer's Certification: Jeffery C. Orsborn, PE attest that this application for (Professional Engineer's name from Application Item 111.1.) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdeme or, which may fine include a not to exceed $10,000, as well as civil penalties up to $25,000 per violation. • , t 1111 f, ff, 7 North Carolina Professional Engineer's seal, signature, and date: 3. Applicant's Certification per 15A NCAC 02T .0106(b): Sean McDonnell, Manager attest that this application for (Signature Authority's name & title from Application Item 1.3.) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine notfa ccd $10,000 as well as civil penalties up to $25,000 per violation. Date: 7-/6-20t5 FORM: FTA 04-16 Page 5 of 5 CHARLOTTE W T E R July 3, 2018 Mr. Mackenzie McCool Orsborn Engineering Group 610 E. Morehead Street Charlotte, NC 28202 SUBJECT: WATER AND SEWER FLOW ACCEPTANCE LANCE PINEVILLE 10499 ROYSHAL LANE, CHARLOTTE NC CLTWATER TRACKING# 2018917 After an analysis of the sanitary sewer associated with the proposed design of project 2018917, Lance Pineville, it was determined that there is sufficient capacity to accommodate the proposed sewer flow of 8,000 gallons per day (20 emp x 25 gal/emp; 75 bays x 100 gal/bays) at the connection point(s) indicated on the submitted utility plan for transmission to the McAlpine Creek Wastewater Treatment Plant; NPDES permit number NC0024970, for treatment. This acceptance of flow is based upon the existing capacity of the designated publicly owned treatments works. Please see the attached NC DEQ FTSE form. Charlotte Water (CLTWater) agrees to furnish water to the subject project. The water quality to the subject project is regulated by the State Drinking Water Act Amendments of 1986 and The Water Supply Management Plan, PWS ID # 0160010 on file with the Public Water Supply Section of NCDEQ. However, CLTWater cannot guarantee a constant pressure or quality of flow. The applicant should understand that due to the involvement of other agencies and continuing growth of the water system, the ability to provide service for future projects cannot be guaranteed nor reserved. Connection to the CLTWater system is accepted on a first come, first served basis. The applicant should understand that this letter is not authorization to construct or extend private water or sewer systems, as the appropriate local or State permits are required prior to construction. you have any not hesitate to contact me at (704) 336-1006. Sincerely, Gwendolyn Banner Engineering Assistant Charlotte Water 5100 Brookshire Blvd, Charlotte, NC 28216 chailottewater.org operated by the City of Charlotte State of North Carolina Department of Environmental Quality MAURDivision of Water Resources Division of water Resources Flow Tracking/Acceptance for Sewer Extension Applications (FTSE 04-16) Entity Requesting Allocation: Orsborn Engineering Project Name for which flow is being requested: Lance Pineville Adore than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route ofthe proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name; McAlpine Creek, Irwin Creek, Sugar Creek b. WWTP Facility Permit 4: NC0024970, NC0024945, NCO024937 All flows are in MGD e. WWTP facility's permitted flow 99.0 d. Estimated obligated flow not yet tributary to the WWTP 11.785 e. WWTP facility's actual avg. flow 85.008 f. Total flow for this specific request 0.008 g. Total actual and obligated flows to the facility 78.801 h. Percent of permitted flow used 77.8% It. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Average Daily Appmx. Not Yet Total Current Station Firm Flow** Current Avg. Tributary Flow Plus (Name or Capacity, * (Firm / pi), Daily Flow, Daily Flow, Obligated Available Number) MOD MOD MOD MGD Flow Capacity*** *The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is <0. Downstream Facility Name (Sewer): Unknown Downstream Permit Number: Unknown Page 1 of 6 FTSE 04-16 Ill. Certification Statement: Keri Cantrell certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form indicates acceptance of this wastewater flow. Official Signature K,; 6/26/2018 Dare Page 2 of 6 FTSE 04-16 Q RIM 0 PUBLIC PRIVATE PUBLIC SEW[ SEPARATELY 550 !ND, sr�< oR JOB p 17045 -- DATE: 05/17/18 USGS QUAD MAP EXHIBIT SCALE: 1"=500' FOR DRAWN BY: MLM PINEVILLE DISTRIBUTION LOT 6 APPROVED BY: 1C0 PINEVILLE, NORTH CAROLINA A ORSBORN ENGINEERING GROUP 610 EAST MOREHEAD STREET, SUITE 106 CHARLOTTE, NC 28202 P) 704-7494432. F) 704-749-1433 North Carolina Secretary of State Search Results Page 1 of 1 • File an Annual Report/Amend an Annual Report • Upload a PDF Filing • Order a Document Online Add Entity to My Email Notification List • View Filings • Print an Amended a Annual Report form • Print a Pre -Populated Annual Report form Limited Liability Company Legal Name BIN - PDS LLQ Information Sosld: 1679930 Status: Current -Active Annual Report Status: Current Citizenship: Domestic Date Formed: 3/16/2018 Registered Agent: Shaughnessy, Timothy C Addresses Mailing Principal Office Reg Office 500 E Morehead St Ste 200 500 E Morehead St Ste 200 500 E Morehead St Ste 200 Charlotte, NC 28202 Charlotte, NC 28202 Charlotte, NC 28202 Reg Mailing 500 E Morehead St Ste 200 Charlotte, NC 28202 Company Officials All LLCs are managed by their managers pursuant to N.C.G.S. 57D-3-20. https://www.sosne.gov/online_services/search/Business_Registration_lzcsults 7/18/2018