HomeMy WebLinkAbout20180923 Ver 1_Permit Drawings_20180703�
�
�
•�
�
V
�
�
0
V
�
SEE SHEET l A FOR INDEX OF SHEETS
SEE SHEET 1-B FOR CONVENTIONAL SYMBOLS
5�I ' ��� ,��'° T���� I � "�"� ��°����1��1�,�
I ? ������1� i o ��� I�������� �i��
1�ORTHAMPT01� COUI�TY
LOCATIOIV: BRIDGE 1V0. 49 OVER BRANCH OF CORWELLS MILLPOND 01V
SR 1300 (BIG JOHN'S STORE RD.)
TYPE OF WORK GRADI11tG, DRAI11lAGE, PAVIIVG A11tD STRUCTURE
WETLAND AND SURFACE WATER IMPACTS PERM11�
THIS PROIECT IS NOT WITHIN ANY MUNICIPAL BOUNDARIES.
CLEARING ON THIS PROJECT SHALL BE PERFORMED TO THE LIMITS ESTABLISHED BY METHOD II.
GRAPHIC SCALES DESIGN DATA
50 25 0 50 l00 ADT 2017 = 510
ADT 2037 = 535
PLANS K = 10 %
D = 60 %
�0 50 �oo T = 6 % *
V = 45 MPH
PROFILE (HORIZONTAL) * TTST =2% DUAL 4%
l0 5 0 l0 Zp FUNC CLASS = LOCAL
SUBREGIONAL TIER
PROJECT LENGTH
LENGTH ROADWAY TIP PROJECT 17BP.1.R.81 = 0.091 MILES
LENGTH STRUCTURE TIP PROJECT 17BP.1.R.81 = 0.013 MILES
TOTAL LENGTH TIP PROIECT 17BP.1.R.81 = 0.104 MILES
I�a�� of Transyort¢tian in the Office of.•
''Y ETHERILL
ENGINEERING - � - ''a"'
��
20l2 STANDARD SPECfF7CATlONS
RIGHT OF WAY DATE: EDWARD G. WETHERILL, PE
PROJF,CT ENG7N&ER
LETTING DATE:
NCDOT CONTACT:
BOB A. MAY, PE
PROJECT DESfGN F.NGINEER
JOHN S. ABEL, JR.
DN7SION 1 BR7DGF. PROGftAM MANAGF.R
STAT6 STxTE PRO.I�CT REPERENCC NO.
���� 17BP.1.R.80
3PnTC PROJ.NO. . . . .
776P.1.R.80
s Neo r �
SHCF.TS
�
ESCRIPTION
PE
PERMIT DRAWING
SHEET 1 OF 5
NOTE: NO DECK DRAINS
OVER OPEN WATER
P�
�
,I -,'• C i:l
� / // //
HI'DRAULICS ENGINEER
ROADWAY DESIGN
ENGINEER
P.E.
P.E.
�N�C���1[1P1L]E°Il'1E ]�1L:�N�
DO NOT �*SE POR R6R' ACOUISITION
DOCUMENT NOT CONSIDERED FINAL
UNLESS ALL SIGNATURES COMPLETED
WETLAND PERMIT IMPACT SUMMARY
WETLANDIMPACTS SURFACE WATERIMPACTS
Hand Existing Existing
Permanent Temp. Excavation Mechanized Clearing Permanent Temp. Channel Channel Natural
Site Station Structure Fillln Fillln in Clearing in SW SW Impacts Impacts Stream
No. (From/To) Size / Type Wetlands Wetlands Wetlands in Wetlands Wetlands impacts impacts Permanent Temp. Design
(ac) (ac) (ac) (ac) (ac) (ac) (ac) (ft) (ft) (ft)
1 17+00 to 18+50 1@35' 1@25' 18" Cored Slab 0.01 10
TOTALS': 0.01 10
*Rounded totals are sum of actual impacts
NOTES:
Fill in Wetlands = 604 sq ft.
Stream impacts from bank stabilization = 10 ft.
�
F �i�h�v�l�� North Carolina Department of Transportation
S tOl"Y114V ti t�`S'
, ..., . Highway Stormwater Program � � i
STORMWATER MANAGEMENT PLAN —
(Version 2.01; Released Uecember 2014) FOR NCDOT PROJECTS
WBS Element: 17BP.1.R.80 TIP No.: SF-650049 Count ies): Northampton Pa e 1 of 1
General Project Information
WBS Element: 17BP.1.R.80 TIP Number: SF-650049 Project Type: Bridge Replacement Date: 4/5/2018
NCDOT Contact: Clay Willis (DEO) Contractor I Designer: Wetherill Engineering, Inc. / Harminder Singh, PE
Address: Highway Division 1 Address: 1223 Jones Franklin Rd.
113 Airport Dr. Suite 100
Edenton, NC 27932 Raleigh, NC 27606
Phone:(252)482-1876 Phone:919-851-8077
Email: tcwillis(�ncdot.qov Email: hsinqh(a�wetherillenq.com
CitylTown: Garysburg, NC County(ies�: Northampton
River Basin(s): Chowan CAMA County? No
Wetlands within Project Limits? Yes
Project Description
Project Length (fin. miles or feet): 0.10 Surrounding Land Use: Rural, Wooded, Agricultural
Proposed Project Existing Site
Project Built-Upon Area (ac.) 0.3 ac. 0.3 ac.
Typical Cross Section Description: (2) 10' lanes with grassed shoulders and up to 5' shoulders with guardrail. 5' shoulders (2) 10' lanes with grassed shoulders
are variable width paved.
Annual Avg Daily Traffic (vehlhr/day): Design/Future: 535 Year: 2037 Existing: 510 Year: 2017
General Project Narrative: Replace bridge no. 49 over Corwells Millpond on SR 1300 Big John's Store Road. Use 1@35' 1@25' 18" Cored Slab. At begin bridge, a TB 2GI will outlet on the upstream side
(Description of Minimization of Water of the bridge with 15" RCP with Class B rip rap used to stabilize the outlet. No deck drains will discharge directly into channel.
Quality Impacts)
Waterbody Information
Surface Water Body (1): Corwells Millpond NCDWR Stream Index No.: 25-4-2-3-1
NCDWR Surface Water Classification for Water Body Primary Classification: Class C None
Supplemental Classification: Nutrient Sensitive Waters (NSW) None
Other Stream Classification: None
Impairments: None
ThreatenedlEndangered Species? No Comments:
NRTR Stream ID: Buffer Rules in Effect: N/A
Project Includes Bridge Spanning Water Body? Yes Deck Drains Discharge Over Buffer? No Dissipator Pads Provided in Buffer? N!A
Deck Drains Discharge Over Water Body? No (If yes, provide justification in the General Project Narrative) (If yes, describe in the General Project Narrative; if no, justify in the
(If yes, provide justification in the General Project Narrative) General Project Narrative)