HomeMy WebLinkAboutCMSWS - Final - Dart- NCS000312 - Stormwater Facility InspectionCharlotte -Mecklenburg
STORM
WATER
Services
September 26, 2016
Jim Kreger, Compliance Manager
Dart Disposal and Recycling Technologies
4132 Pompano Road
Charlotte, NC 28216
Subject: Industrial Facility Inspection
Dart Disposal and Recycling Technologies
Dear Mr. Kreger:
2145 Suttle Avenue
Charlotte, NC 28208-5237
On September 9, 2016, Chad Broadway and Preston Hines of Charlotte -Mecklenburg
Storm Water Services (CMSWS) conducted an inspection of the above referenced facility as a
requirement of the City of Charlotte's NPDES Permit, NCS000240, Part II Section H. Inspection
authority is granted by Charlotte City Code Chapter 18, Article III, Section 18-82. At the time of
inspection, the facility was observed to be in compliance with the City of Charlotte Storm Water
Pollution Control Ordinance.
The inspection was also conducted as part of a cooperative working agreement between
Mecklenburg County and the North Carolina Department of Environmental Quality (NCDEQ) —
Division of Energy, Mineral and Land Resources (DEMLR). NCDEQ — DEMLR has been copied
on this report and made aware of the following observations regarding the facility's NPDES
stormwater permit:
1) Stormwater Pollution Prevention Plan (SPPP)
A Stormwater Pollution Prevention Plan (SPPP) has been developed and implemented; however,
several elements of the SPPP have not been updated and documented as required by the facility's
NPDES permit.
2) Qualitative Monitoring
Qualitative monitoring has been conducted and recorded.
3) Analytical Monitoring
Analytical monitoring has been conducted and recorded.
•
hTo report pollution or drainage problems, call: 311
http://stormwater.charmeck.org'
0[A1iro,r,rr.
Mr. Jim Kreger
Page 2
September 26, 2016
Thank you for the assistance and cooperation with the site inspection. The attached
report provides details about inspection observations and should be self-explanatory. Please
contact me at (704) 280-1497 if you have any questions or need additional information. For
questions specifically regarding your NPDES stormwater permit, please contact Zahid Khan with
NCDEQ — DEMLR at (704) 663-1699.
Sincerely,
Chad Broadway
Environmental Specialist
Charlotte -Mecklenburg Storm Water Services
cc: Kristen O'Reilly, Charlotte Storm Water Services
Zahid Khan, NCDEQ — DEMLR
Attachment
Gtarlotte-Mecklenburg
STORM
...WATER Facility
Services
Inspection
2145 Suttle Avenue
Charlotte, NC 28208
Facility Name: Dart Disposal and Recycling Technologies Inspection #: 26495
Contact: Jim Kreger, Compliance Manager Permit #:
Inspector: Chad Broadway Receiving Stream: Irwin Creek
Inspection Date: 09/09/2016 Entry Time: 9:35 am Exit Time: 11:55 am SIC #:
Facility Description: Dart Disposal and Recycling Technologies is a permitted treatment, storage, and disposal facility
for hazardous and non -hazardous materials. The facility accepts various products for either onsite disposal or
consolidation and shipment to other facilities for processing. Received materials undergo profiling and analysis prior to
storage or processing at the facility.
File Review/History: Charlotte -Mecklenburg Storm Water Services (CMSWS) previously conducted an inspection at this
facility on 11/14/2013.
Inspection Summary: At the time of inspection, this facility was observed to be in compliance with the City of Charlotte
Storm Water Pollution Control Ordinance. Please see the report for recommendations and comments.
ObTo report pollution or drainage problems call: 311
CIL TE. http://stormwater.charmeck.org
9/26/2016 8:13:50AM
ec�
Page 1 of 4
Site Inspection Deficiency Comments
Stormwater system (catch basins,
No
Stormwater flows through the site via sheet flow to a concrete
inlets, outfalls, etc.)
retention pond where stormwater is contained until it is
manually discharged to outfall #001 via a gate valve.
Erosion issues
Recommendation
Erosion was observed at the discharge point of outfall #001.
CMSWS recommends stabilizing the area with an energy
dissipator (ie. riprap) or another means of stabilization to
prevent ongoing erosion.
Structural stormwater BMPs
No
The facility has one concrete retention pond that collects flow
from the facility grounds. The basin outlet is controlled with a
gate valve that remains closed, providing a containment point
for any potential spills occurring on site. Per facility
personnel, the capacity of the basin is 22,500 cubic feet.
Illicit discharges/connections
No
No illicit discharges or connections were observed during the
inspection.
Aboveground storage tank(s) - list
No
The facility has four 25,000 -gallon tanks and three
tank sizes & contents
10,000 -gallon tanks indoors associated with the facility's
wastewater treatment process. Additional vessels
associated with the facility's thermal stripper are located
under canopy cover at the rear of the facility. 55 -gallon
drums, totes, and other tanks containing various chemicals
to be processed or shipped to another facility are located
indoors.
Underground storage tank(s) - fill port
N/A
The facility does not have underground storage tanks.
area; list tank sizes & contents
ObTo report pollution or drainage problems call: 311
CIL TE. http://stormwater.charmeck.org
9/26/2016 8:13:50AM
ec�
Page 1 of 4
INSPECTION DETAILS
Site Inspection Deficiency Comments
Outdoor material storage area(s)
Recommendation
At the time of inspection, a large tank previously used for
chemical processing was observed to be stored outdoors with
the lid slightly askew, allowing accumulation of stormwater.
All valves were closed and no discharge was observed around
the vessel; however, CMSWS recommends the tank be
covered to prevent stormwater accumulation and potential
unintended discharge. Additionally, an empty 55 -gallon drum
of unknown previous contents was stored outdoors with the
lid not properly placed.
Outdoor processing area(s)
No
Loading/unloading area(s)
No
Vehicle/equipment area(s) - fueling,
No
The facility does not conduct vehicle fueling, washing, or
washing, storage, etc.
maintenance on site.
Oil/water separator and/or
No
As a part of primary facility operations, certain types of
pretreatment
chemicals received by the facility are processed using an air
sparger, thermal treatment, and plate/press treatment. Upon
final treatment, the waste stream is then discharged to the
sanitary sewer via two 'outfalls" that are monitored by the
facility and inspected periodically by Charlotte Water
(formerly Charlotte Mecklenburg Utilities).
Waste storage/disposal area -
No
dumpsters, scrap metal bins, etc.
Food service area(s)
N/A
Indoor material storage area(s)
No
The facility stores 55 -gallon drums, totes, and other
containers of various caustics, corrosives, flammables, and
other chemicals. The chemical storage areas were observed
to be well kept and organized based on type / reactive nature.
Dikes were located at each point of ingress/egress to prevent
a potential spill from discharging outdoors, and
chemical -specific storage areas were also divided by dikes.
Indoor processing area(s)
No
Indoor processing areas consist of components related to
waste processing/treatment, including an air sparging unit,
plate press filter unit, and associated tanks.
Floor drains
No
Grated trench drains / floor drains were observed in several
areas of the facility. Per the facility manager, these drains
are "dead sumps" and any accumulated product is vacuumed
out and placed into a tank for on-site treatment.
Spill response equipment
No
Spill response equipment was observed in a shed at the rear
of the facility. The facility has contracted with Shamrock
Environmental to provide emergency response services in the
event of a significant spill.
Stormwater Pollution Plan Observed Comments
Does the facility have a stormwater
Yes
pollution prevention plan?
General location (USGS) map
Yes
Narrative description of practices
Yes
Detailed site map
Yes
List of significant spills (past 3 years)
No Per the facility manager, no significant spills have occurred
within the previous three years. However, the facility should
be making an annual "notation of no spills" in year when no
spills have occurred, as per Part II, Section 7 of the permit.
�• �a
To report pollution or drainage problems call: 311
CILIRLOTT>;. `
\\MO http://stormwater.charmeek.org €"-�`i
9/26/2016 8:13:50AM Page 2 of 4
•
obTo report pollution or drainage problems call: 311
CIL TE. http://stormwater.charmeck.org
9/26/2016 8:13:50AM
0
Page 3 of 4
Stormwater Pollution Plan Observed Comments
Non-stormwater discharge evaluation
No
The facility last conducted a non-stormwater discharge
of outfall(s)
evaluation on 7/5/2011. A non-stormwater discharge
evaluation should be conducted on an annual basis, as per
Part 11, Section 1(e) of the permit.
Feasibility study
Yes
All necessary secondary
Yes
containment provided
Collected water evaluated and
N/A
documented prior to release
BMP Summary
Yes
Spill prevention and response plan
Yes
Preventative maintenance and good
Yes
housekeeping plan
Facility provides and documents
Yes
employee training
List of responsible parties
Yes
Reviewed and updated annually
No
A documented review and update of the plan was last
conducted on 7/1/2015.
Stormwater facility inspection
Yes
The facility conducts daily, weekly, and monthly inspections
program conducted semi-annually
of various facility components that satisfy the stormwater
facility inspection requirements.
Qualitative/Analytical Monitoring Observed Comments
Qualitative monitoring conducted
Yes
The facility most recently conducted qualitative monitoring on
semi-annually
2/25/2016, 10/1/2015, and 4/15/2015.
Analytical monitoring conducted
Yes
The facility most recently conducted analytical monitoring on
semi-annually
2/25/2016, 10/1/2015, and 4/15/2015. One instance of
exceeding the pH benchmark range (pH = 9.28) was
observed during 2015. All other monitoring data reviewed was
within permit benchmarks.
Analytical monitoring from vehicle
N/A
maintenance
Permit and Outfalls Observed Comments
Copy of permit and certificate of
Yes
coverage onsite
All outfalls observed
Yes
Erosion was observed at the discharge point of outfall #001.
CMSWS recommends repairing and stabilizing this area to
prevent ongoing erosion.
Number of Outfalls Observed
1
Representative outfall status
N/A
documented by NCDWQ
Annual no -exposure self
N/A
re -certification documented
Phase II Permit Requirements Observed Comments
Wastes removed from the MS4
N/A
properly disposed
Public transportation (roadway)
N/A
projects constructed within the last
year
Curb miles and parking lots swept
N/A
documented
Catch basin and storm drain pipe
N/A
cleaning documented
•
obTo report pollution or drainage problems call: 311
CIL TE. http://stormwater.charmeck.org
9/26/2016 8:13:50AM
0
Page 3 of 4
•
Phase II Permit Requirements Observed Comments
Records of pesticide/herbicide
N/A
applicator licenses maintained for
staff and contractors
If pesticide treatment areas
N/A
exceeded, was permit application
submitted?
Pesticide limitations in Goose Creek
N/A
Watershed followed
&•
To report pollution or drainage problems call: 311
CI TC. http://stormwater.charmeck.org
9/26/2016 8:13:50AM
0