HomeMy WebLinkAboutWQ0040043_Application_20180606STRONGER BY DESIGN
May 31, 2018
Mooresville Regional Office
Water Quality Section
610 E. Center Avenue
Mooresville, North Carolina 28115
Re: Optimist Park Townhomes
aka Parkwood Square Townhomes
Fast Track Application FTA 10-14
To whom it may concern;
RECEIVED/NCDENR/DWR
JUN 4 2018
WOROS
MOORESVILLE REGIONAL OFFICE
Enclosed please find the Fast Track Application for the referenced project.
The project includes the construction of a private sanitary sewer extension to serve
a new residential townhome project.
This package includes the following;
• Check # G� in the amount of $480.00
• Application and Checklist (FTA 04-16)
• Street level map (by Google, 2018)
• USGS Quad map
• Charlotte Water flow acceptance letter (5/30/2018)
• Developer's Operational Agreement
Please contact me with any comments or questions at (704) 909-3503.
Sincerely,
5� '12�VS:Z7�
Jamey Baysinger
Project Manager
Enclosures (listed above)
CC: Andy Lucas, Optimist Park Partners
101 NORTH TRYON ST. CHARLOTTE, NC T 704.334.7925
SUITE 1400 28202 F 704.334.7926
State of North Carolina
Department of Environmental Quality
DWR Division of Water Resources
15A NCAC 02T.0300 —FAST TRACK SEWER SYSTEM EXTENSION APPLICATION
Division of Water Resources FTA 04-16 & SUPPORTING DOCUMENTATION
Application Number: WQWqb6 �3 (to be completed by DwR)
All items must be completed or the auotication will be returned
I. APPLICANT INFORMATION:
1. Applicant's name: Optimist Park Partners (company, municipality, HOA, utility, etc.)
2. Applicant type: ❑ Individual ❑ Corporation ® General Partnership ❑ Privately -Owned Public Utility
❑ Federal ❑ State/County ❑ Municipal ❑ Other
3. Signature authority's name: Andy Lucas per 15A NCAC 02T .0106(¢)
Title: Principal
RECEIVEDINCDENRIDWR
4. Applicant's mailing address: 623 S. Cedar Street, Suite A
City: Charlotte State: NC Zip: 28202-_
JUN 4 '/018
5. Applicant's contact information: WOROS
Phone number: (4I0) 804-0360 Email Address: andy.lucas(obeauxwri hg t.com MOORESVILLE RE(lrtNAL OFFICE
II. PROJECT INFORMATION:
1. Project name: Parkwood Square Townhomes (fka 300 Optimist Park Townhomes)
2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project
If a modification, provide the existing permit number: W000_ and issued date:
If new construction but part of a master plan, provide the existing permit number: WQ00_
3. County where project is located: Mecklenburg
4. Approximate Coordinates (Decimal Degrees): Latitude: 35.2345° Longitude: -80.8254°
5. Parcel ID (if applicable): 08106111
(or Parcel ID to closest downstream sewer)
III. CONSULTANT INFORMATION:
1. Professional Engineer: James R. Baysinger, II License Number: 34628
Firm: Stewart Inc.
Mailing address: 101 North Tryon St. STE 1400
City: h rlotte State: NC Zip: 28202
Phone number: (704) 334-7925 Email Address: sin er .stewartinc.com
IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION:
1. Facility Name: Sugar Creek W WTP Permit Number: NCO024937
Owner Name: Charlotte Water
V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF):
1. Permit Number(s): WQ_ Downstream (Receiving) Sewer Size: — inch
System Wide Collection System Permit Number(s) (if applicable): WQCS_
Owner Name(s):
FORM: FTA 04-16 Page 1 of 5
VI. GENERAL REQUIREMENTS
1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached?
❑ Yes ❑No ®N/A
2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement ( FORM: DEV 1 been attached?
®Yes ❑No ❑N/A
3. If the Applicant is a Home/Property Owners' Association, has an Operational Agreement (FORM: HOA) been attached?
❑ Yes ❑No ®N/A
4. Origin of wastewater: (check all that apply):
® Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash
❑ Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels
❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool /Clubhouse
❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash
❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment)
5. Nature of wastewater: 100 % Domestic/Commercial %Commercial
Industrial (See 15A NCAC 02T.0 103(20))
"Is there a Pretreatment Program in effect? ❑ Yes ❑ No
6. Has a flow reduction been approved under 15A NCAC 02T.01 14(f)? ❑ Yes ® No
If Yes, provide a copy of flow reduction approval letter
7. Summarize wastewater generated by project:
Establishment Type (see 02T.01140
Daily Design Flow'"
No. of Units
Flow
Residential (Townhomes)
190 galfUnit
59
11,210 GPD
gal/
GPD
gal/
GPD
gal/
GPD
gal/
GPD
gal/
GPD
Total
11,210 GPD
a See 15A NCAC 02T .01 14(b), (d). (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per
dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas;
and residential property located south or east ofthe Atlantic Intracoastal Waterway to be used as vacation rentals as defined
in G.S. 42A-4).
b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01141 shall be
determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data.
8. Wastewater generated by project: 11210 GPD (per 15A NCAC 02T.01 14)
➢ Do not include future flows or previously permitted allocations
If permitted flow is zero, indicate why:
❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line
❑ Flow has already been allocated in Permit Number:
❑ Rehabilitation or replacement of existing sewer with no new flow expected
❑ Other (Explain):
FORM: FTA 04-16 Page 2 of 5
VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T.0305 & MDC (Gravity Sewersl:
1. Summarize gravity sewer to be permitted:
Size (inches) Length (feet) Material
6 792 DIP
➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria
➢ Section III contains information related to minimum slopes for gravity sewer(s)
➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC
VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains:
COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT
1. Pump station number or name
2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - °
3. Design flow of the pump station: _ millions gallons per day (firm capacity)
4. Operational point(s) of the pump(s): _ gallons per minute at _ feet total dynamic head (TDH)
5. Summarize the force main to be permitted (for this Pump Station):
Size (inches) Length (feet) Material
6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1):
❑ Standby power source or pump with automatic activation and telemetry -15A NCAC 02T .0305(h)(1)(B):
➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day
➢ Must be permanent to facility
Or if the pump station has an average daily flow less than 15,000 gallons per day:
❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T
.0305(h)(1)(C)
or
❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C):
➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement)
and is compatible with the station.
➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage
capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided
in the case of a multiple station power outage.
FORM: FTA 04-16 Page 3 of 5
IX. SETBACKS & SEPARATIONS — (02B.0200 & 15A NCAC 02T.0305(f)):
1. Does the project comply with all separations found in 15A NCAC 02T.0305(f) & (e)
➢ 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems:
® Yes ❑ No
Setback Parameter*
Separation Required
Storm sewers and other utilities not listed below vertical
24 inches
Water mains vertical -water over sewer including in benched trenches
18 inches
Water mains horizontal
10 feet
Reclaimed water lines vertical - reclaimed over sewer
18 inches
Reclaimed water lines horizontal - reclaimed over sewer
2 feet
**Any private or public water supply source, including any wells, WS -I waters of Class I or
Class II impounded reservoirs used as a source of drinking water
100 feet
**Waters classified WS (except WS -1 or WS -V), B, SA, ORW, HQW, or SB from normal
high water or tide elevation and wetlands see item IX.2
50 feet
**Any other stream, lake, impoundment, or ground water lowering and surface drainage
ditches
10 feet
Anv buildinR foundation
5 feet
Any basement
10 feet
Top slope of embankment or cuts of 2 feet or more vertical height
10 feet
Drainage systems and interceptor drains
5 feet
Any swimming pools
10 feet
Final earth grade vertical
36 inches
➢ 15A NCAC 02T.0305(e) contains alternatives where separations in 02T.0305(f) cannot be achieved.
➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications weboa¢e
➢ If noncompliance with 02T.0305(f) or (g). see Section X of this application
2. Does the project comply with separation requirements for wetlands? (50 feet of separation) [-]Yes ❑No ®N/A
➢ See the Division's draft separation requirements for situations where separation cannot be meet
➢ No variance is required if the alternative design criteria specified is utilized in design and construction
➢ As built documents should reference the location of areas effected
3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B.0200? ❑ Yes ❑ No ® N/A
➢ This would include Trout Buffered Streams per 15A NCAC 213.0202
4. Does the project require coverage/authorization under a 404 Nationwide or ❑ Yes ® No
individual permits or 401 Water Quality Certifications?
➢ Information can be obtained from the 401 & Buffer Permitting Branch
5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes ❑ No
Per 15A NCAC 02T.0105(c)(6). directly related environmental permits or certification applications are being prepared, have
been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and
sedimentation control plans, stormwater management plans, etc.).
6. Does this project include any sewer collection lines that are deemed "high-priority?"
Per 15A NCAC 02T.0402. "high-priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer
positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer.
❑ Yes ® No ❑ N/A
➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location).
High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections
documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit.
FORM: FTA 04-16 Page 4 of 5
X. CERTIFICATIONS:
1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pumg Stations
and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria (latest version) as applicable?
® Yes ❑ No
If No, complete and submit the Variance/Altemative Design Request application (VADC 10-14) and supporting documents for
review. Approval of the reauest is required prior to submittal of the Fast Track Application and supportine documents.
2. Professional Engineer's Certification:
I,
Application Item 111. 1.)
that this application for
has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications,
engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best
of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer
Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting
of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this
submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and
have judged it to be consistent with the proposed design.
NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false
statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may
include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation.
North Carolina Professional Engineer's seal, signature, and date:
'FESS%O y9',
a� SEAL
_ 34628
- S; NINE ;Q�\��
5�3,�2dtg sR./BAYS1NG����
3. Applicant's Certification per 15A NCAC 02T .0106(b):
as Manager of Optimist Park Partners, LLC
Authority's name & title from Application Item I.3.)
that this application for
has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of
this application are not completed and that if all required supporting documentation and attachments are not included, this
application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non -
discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties,
injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition
of this permit be violated. I also understand that if all required parts of this application package are not completed and that if
all required supporting information and attachments are not included, this application package will be returned to me as
incomplete.
NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false
statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may
include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation.
Signature: `
as Manager of Optimist Park Partners, LLCDate: 5/31/2018
FORM: FTA 04-16 Page 5 of 5
STATE OF NORTH CAROLINA • /'l ' /,�W40.
COUNTYOF Mecklenburg Permit No. Vtlo`f3
DEVELOPER'S OPERATIONAL AGREEMENT
This AGREEMENT made pursuant to G.S. 143-215.1 (dl) and entered into this day of
, by and between the North Carolina Environmental Management
Commission, an agency of the State of North Carolina, hereinafter known as the COMMISSION; and
Optimist Park Partners, LLC , a corporation/general partnership registered/licensed to do
business in the State of North Carolina, hereinafter known as the DEVELOPER.
WITNESSETH:
1. The DEVELOPER is the owner of the certain lands lying in Mecklenburg County, upon
which it is erecting and will erect dwelling units and other improvements, said development to be known
as Parkwood Square Townhomes (hereinafter the Development).
2. The DEVELOPER desires, to construct a wastewater collection system with pumps, wastewater treatment
works, and/or disposal facilities (hereinafter Disposal System) to provide sanitary sewage disposal to serve
the Development on said lands.
3. The DEVELOPER has applied to the COMMISSION for the issuance of a permit pursuant to G.S. 143-
215.1 to construct, maintain, and operate the Disposal System.
4. The DEVELOPER has created or shall create unit ownership in said dwellings units, other improvements
and lands through filing of a Declaration of Unit Ownership (hereinafter Declaration), pursuant to Chapter
47C or 47F of the North Carolina General Statutes.
5. The DEVELOPER has caused to be formed or will cause to be formed at the time of filing of the
Declaration, the (Unit Owners' Association) Parkwood Square HOA (hereinafter
Association), a non-profit corporation organized and existing under and by the virtue of the laws of the State
of North Carolina, for the purpose, among others, of handling the property, affairs and business of the
Development; of operating, maintaining, re -constructing and repairing the common elements of the lands
and improvements subject to unit ownership, including the Disposal System; and of collecting dues and
assessments to provide funds for such operation, maintenance, re -construction andrepair.
6. The COMMISSION desires to assure that the Disposal System of the Development is properly constructed,
maintained and operated in accordance with law and permit provisions in order to protect the quality of the
waters of the State and the public interest therein.
NOW, THEREFORE, in consideration of the promises and the benefits to be derived by each of the parties
hereto, the COMMISSION and DEVELOPER do hereby mutually agree as follows:
1. The DEVELOPER shall construct the Disposal System in accordance with the permit and plans and
specifications hereafter issued and approved by the COMMISSION, and shall thereafter properly operate
and maintain such systems and facilities in accordance with applicable permit provisions andlaw.
2. The DEVELOPER shall not transfer ownership and/or control of the Disposal System to the Association
until construction has been completed in accordance with the permit and approved plans, and the staff of
the Division of Water Resources has inspected and approved of the facilities. In order to change the name
of the permit holder, the DEVELOPER must request that the permit be reissued to the Association. The
request must include a copy of the Association Bylaws andDeclaration.
3. The DEVELOPER shall not transfer, convey, assign or otherwise relinquish or release its responsibility for
the operation and maintenance of its Disposal System until a permit has been reissued to the DEVELOPER's
successor.
rnD A.T. T ulT 11 1^I D,..... 1 ,.eq
4. The DEVELOPER shall provide in the Declaration and Association Bylaws that the Disposal System and
appurtenances thereto are part of the common elements and shall thereafter be properly maintained and
operated in conformity with law and the provisions of the permit for construction, operation, repair, and
maintenance of the system and facilities. The Declaration and Bylaws shall identify the entire wastewater
treatment, collection and disposal system as a common element which will receive the highest priority for
expenditures by the Association except for Federal, State, and local taxes and insurance.
5. The DEVELOPER shall provide in the Declaration and Association Bylaws that the Disposal System will
be maintained out of the common expenses. In order to assure that there shall be funds readily available to
repair, maintain or construct the Disposal System, beyond the routine operation and maintenance expenses,
the Declaration and Association Bylaws shall provide that a fund be created out of the common expenses.
Such fund shall be separate from the routine maintenance funds allocated for the facility and shall be part
of the yearlybudget.
6. In the event the common expense allocation and separate fund are not adequate for the construction, repair,
and maintenance of the Disposal System, the Declaration and Association Bylaws shall provide for special
assessments to cover such necessary costs. There shall be no limit on the amount of such assessments, and
the Declaration and Bylaws shall provide that such special assessments can be made as necessary at any
time.
7. If a wastewater collection system and wastewater treatment and/or disposal facility provided by any city,
town, village, county, water and sewer authorities, or other unit of government shall hereinafter become
available to serve the Development, the DEVELOPER shall take such action as is necessary to cause the
existing and future wastewater of the Development to be accepted and discharged into said governmental
system, and shall convey or transfer as much of the Disposal System and such necessary easements as the
governmental unit mayrequire as condition of accepting the Development's wastewater.
8. Recognizing that it would be contrary to the public interest and to the public health, safety and welfare for
the Association to enter into voluntary dissolution without having made adequate provision for the continued
proper maintenance, repair and operation of its Disposal System, the DEVELOPER shall provide in the
Association Bylaws that the Association shall not enter into voluntary dissolution without first having
transferred its said system and facilities to some person, corporation or other entity acceptable to and
approved by the COMMISSION by the issuance of apermit.
9. The agreements set forth in numbered paragraphs 1, 2, 3, 4, 5, 6, 7, and 8 above shall be conditions of any
permit issued by the COMMISSION to the DEVELOPER for the construction, maintenance, repair and
operation of the Disposal System.
10. A copy of this agreement shall be filed at the Register of Deeds in the County(ies) where the Declaration is
filed and in the offices of the Secretary of State of North Carolina with the Articles of Incorporation of the
Association.
IN WITNESS WHEREOF, this agreement was executed in duplicate originals by the duly authorized
representative of the parties hereto on the day and year written as indicated by each of the parties named below:
FOR THE ENVIRONMENTAL
MANAGEMENT COMMISSION
Linda Culpepper
Interim Director, Division of Water Resources
(Date)
Optimist Park Partners, LLC
NameofDEVELOPER
Bv: Manager
(Signature)
Andy Lucas, Manager of Optimist Park Partners, LLC
Print Name and Title
5/31/2018
(Date)
rnDxx. rwxf 1 1 1 � n,...,. � ,.ems
0 0
o to
a �
d
a
w
vi
C7
a
F
z
w
w
U
Z
C
E
La
w
2
N
w
O
n
m
C
Q
U
L
0
O
Z
O
N
N
Ln
U
Z
6
Y
Y
O
L
m
L
V
0
O
Y
U
m
Q
mo
c
O
Y
m
Z
Ln
Ln
D
0
t'
`plc
1
0 0
o to
a �
d
a
w
vi
C7
a
F
z
w
w
U
Z
C
E
La
w
2
N
w
O
n
m
C
Q
U
L
0
O
Z
O
N
N
Ln
U
Z
6
Y
Y
O
L
m
L
V
0
O
Y
U
m
Q
mo
c
O
Y
m
Z
Ln
Ln
D
? c n-E,21shS1" .tiq�uk'«5���;. -- 'i ❑
i
E 19111
I Y
t. ) fro. ❑ — }
F1, 1
Y Y 41, U".
4
ttt � <
f �
lay � �� � I�L�I ,,�iy� •
� a
1• �� y `�Sj7rt '
.'�
ax: xi �x ��+�►�, #: _ w �. ,IE 16th 16th St ..
€ o Y.
qq yy �,rr �f
X599 � r to ° m e i x
al
`!tom Vi
..:'1�.. �s. ._ �� ��� S __ r. �� _ Viit`..
i Im ry:
ION
iRR ,yg
CHARLOTTE
W4)TER
May 30, 2018
Mr. David Starkel
Stewart Engineering, Inc.
101 N Tryon St
Suite 1400
Charlotte, NC 28202
SUBJECT: WATER AND SANITARY SEWER FLOW ACCEPTANCE
300 OPTIMIST PARK
E16 TH STREET & N CALDWELL STREET, CHARLOTTE NC
CLTWATER TRACKING# 20171599
After an analysis of the sanitary sewer system associated with the proposed design of project, 300
Optimist Park, it was determined that there will be sufficient capacity to accommodate the proposed
sewer flow of 11,210 gallons per day (59 townhome units x 190 gpd/unit) at the connection point(s)
indicated on the submitted utility plan for transmission to the Sugar Creek Wastewater Treatment
Plant; NPDES permit number NCO024937 for treatment. This acceptance of flow is based on the
existing capacity of the designated publically owned treatment works. Please see the attached NC
DEQ FTSE form.
CLTWater agrees to furnish water to the subject project. The water quality to the subject project is
regulated by the State Drinking Water Act Amendments of 1986 and The Water Supply Management
Plan, PWS ID # 0160010 on file with the Public Water Supply Section of NC DENR. However,
CLTWater cannot guarantee a constant pressure or quality of flow.
CLTWater does not expect any of the above conditions to preclude water or sewer service to the
subject site. However, the applicant should understand that due to the involvement of other agencies
and continuing growth of the water and sewer system, the ability to provide service for future
projects cannot be guaranteed nor reserved. Connection to the CLTWater and sewer system is
accepted on a first come, first served basis.
The applicant should understand that this letter is not authorization to construct private water or
sewer systems, as the appropriate local or State permits are required prior to construction. ff the
appropriate authorization to construct permits are not obtained and construction has not started
within (2) years of issuance of this flow acceptance: and payment for any service connection(s) have
not been received within (2) years of issuance of this flow acceptance, this flow acceptance approval
shall be rescinded and a new flow acceptance request must be made. If you have any questions,
please do not hesitate to contact me at (704) 432-5801.
Sincerely,
Barbara Gross
Engineering Assistant
Charlotte Water 5100 Brookshire Blvd, Charlotte, NC 28216 charlottewater.org
AD Operated by the City of Charlotte
State of North Carolina
Department of Environmental Quality
Division of Water Resources
WO , io€e c., a t ,. Re5oome, Flow Tracking/Acceptance for Sewer Extension Applications
(FTSE 04-16)
Entity Requesting Allocation: Stewart Engineering, Inc.
Project Name for which flow is being requested: 300 optimist Park
More than one FTSE may be requiredfor a single project if the owner of the WWTP is not responsible for all pump
stations along the route of the proposed wastewater flow.
I. Complete this section only if you are the owner of the wastewater treatment plant.
a. WWTPFacility Name: McAlpine Creek, Irwin Creek, Sugar Creek
b. WWTP Facility Permit#: NC0024970, NC0024945, NC0024937
Aff flows are in MGD
c. WWTP facility's permitted flow 99.000
d. Estimated obligated flow not yet tributary to the WWTP 11.466
e. WWTP facility's actual avg. flow 65.433
f. Total flow for this specific request 0.011.
g. Total actual and obligated flows to the facility 76.910
h. Percent of permitted flow used 77.7%
lI. Complete this section for each pump station you are responsible for along the route of this
proposed wastewater flow.
List pump stations located between the project connection point and the WWTP:
(A)
(B)
(C)
(D)=(B+C)
(E)=(A-D)
Design
Obligated,
Pump
Average Daily
Approx.
Not Yet
Total Current
Station
Firm Flow**
Current Avg.
Tributary
Flow Plus
(Name or
Capacity, * (Firm / po,
Daily Flow,
Daily Flow,
Obligated
Available
Number)
MOD MGD
MGD
MGD
Flow
Capacity***
* The Firm Capacity of any pump station is defined as the maximum pumped flow that
can be achieved with the largest pump taken out of service.
** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking
factor (pf) not less than 2.5.
*** A Planning Assessment Addendum shall be attached for each pump station located
between the project connection point and the WWTP where the Available Capacity is < 0.
Downstream Facility Name (Sewer): E 16th Street (Prior 1974
Downstream Permit Number: unknown
Page 1 of 2
FTSE 04-16
III. Certification Statement:
I , Carl Wilson certify to the best of my knowledge that the addition of
the volume of wastewater to be permitted in this project has been evaluated along the route to the
receiving wastewater treatment facility and that the flow from this project is not anticipated to
cause any capacity related sanitary sewer overflows or overburden any downstream pump station
en route to the receiving treatment plant under normal circumstances, given the implementation
of the planned improvements identified in the planning assessment where applicable. This
analysis has been performed in accordance with local established policies and procedures using
the best available data. This certification applies to those items listed above in Sections I and II
plus all attached planning assessment addendums for which I am the responsible party.
Signature of this form indicates acceptance of this wastewater flow.
Signing
Date
Page 2 of 2
FTSE 04-16
North Carolina Secretary of State Search Results
Page I of 1
• File an Annual Report/Amend an Annual Report • Upload a PDF Filing • Order a Document Online
Add Entity to My Email Notification List • View Filings • Print an Amended a Annual Report form • Print a
Pre -Populated hn,mal Report form
Limited Liability Company
Legal Name
Optimist Park Partners, LLC
Information
Sosld: 1582438
Status: Current -Active
Annual Report status: Current
Citizenship: Domestic
Date Formed: 3/21/2017
Fiscal Month: January
Registered Agent: Warren, William C.
Addresses
Mailing
601 S Cedar St Ste 500
Charlotte. NC 28202
Reg Mailing
601 S Cedar St Ste 500
Charlotte, NC 28202
Company Officials
Principal Office
601 S Cedar St Ste 500
Charlotte, NC 28202
Reg Office
601 S Cedar St Ste 500
Charlotte, NC 28202
All LLCs are managed by their managers pursuant to N.C.G.S. 57D-3-20.
Manager
Beauxwright Management, LLC
601 S. Cedar Street, Suite 500
Charlotte NC '`8202
https://ww",.sosne.gov/online_services/search/Business_Registration_Results 6/5/2018