HomeMy WebLinkAboutWQ0002004_Issuance of Permit_20180427 ROY COOPER Covernoi 3 x+ MICHAEL S. REGAN Sect etary Water Resources LINDA CULPEPPER Envaiotunental Quality Interim Director April 27, 2018 Brent Edwards brent@b assfarmsaus age.coin Subject: Permit No.WQ0002004 Bass Farms Wastewater Irrigation System Nash County Dear Mr. Edwards, Staff of the NC Division of Water Resources (DWR), Water Quality Regional Operations Section inspected the subject wastewater irrigation system on April 23, 2018. I wish to thank you and Otto Deans for your help during the inspection. The purpose of the visit was to conduct a compliance inspection of the system. The permit was issued on November 1, 2013 and expires on October 31, 2018. Please begin the process of renewing the permit. The facility averages 5500 to 5800 gpd of the 8500 gpd permitted. Flow from the incoming freshwater meter is used as an estimate of flow through the wastewater treatment system. Fields 1,2, and 3 are in woods and are barely used as the ground stays wet most of the year. Fields 4 and 5 receive about 5" of the 24" permitted with a travelling gun. The pump used to operate the travelling gun stays at the side of lagoon 2. To prevent damage and theft, the piping and the gun are stored behind a locked gate after each use. About 50 lbs of the 200 lbs PAN permitted is applied to,the fields, Hay is harvested off the fields several times a year. Domestic waste produced at the facility is treated by a separate on site system. Grease is skimmed off the grease trap weekly. The grease trap is pumped out as necessary. Both pumps in the aeration basin were in working order. The aeration basin was pumped out during a plant shutdown 3 years ago and concrete was poured around the perimeter on the outside because the steel walls were failing. The pump and alarm in the pump tank were working. Effluent flows to a pump tank and is pumped to the eastern lagoon. The float, light and alarm were tested and found to be in working order. Wash water from the hog holding pen drains to a second pump station. The pump, float, and alarm were in working order. This station pumps to lagoon 1. The aerator in one lagoon was down for repair. The surface aerators are reportedly susceptible to motor damage and gearbox damage during freezing conditions in winter. Replacement With subsurface aerator or installation of a thermal overload switch may be considered to eliminate the problem in the future. The pump house between the lagoons contains 2 pumps, both in working order. The western lagoon rarely needs to be pumped. Freeboard was approximately 3 ft 10 inches in lagoon 1 and 3 ft 3 inches in lagoon 2. ""Not inCompares':-L.-- State mpares-c_....State of North Carolina I Environmental Quality 1611 Mail Service Center I Raleigh,North Ctirolma 27699-1611 919-707-9000 Zi* <; 2�m� �{�^ dm's a_,.�'�a���" ��� T; r�. .�+ � � ° t. n o , . €" Sprayfield maintenance and operation records were in good order. NDAR's and NDMR's have been submitted complete and on time. Soil samples were collected in March 2017. pH records did not indicate a need for lime. Three sprayfields are planted in trees (1, 2 and 3). Trees are periodically removed to encourage growth of grass. One field was operated and the four sprayheads were in good working order. Neither the pump nor the gun were operated during the inspection. Two monitoring wells are present and locked at the north and south end of field 3. Groundwater monitoring is not required by the current permit. The Wastewater Surface Irrigation System appears to be well maintained and in compliance with permit conditions. Please see the attached Inspection Report. If you have any questions regarding this letter, please contact me at (919) 791-4240 or via e-mail at ray.miloshr(a,,ncdenr.gov. Sincerely, Ray Milosh ironmental Specialist Division of Water Resources, Water Quality Regional Operations Section, Raleigh Regional Office Attachment: Compliance Inspection Report cc: RRO-WQROS Files DWR Central Files u Compliance Inspection Report Permit WQ0002004 Effective 11/01/13 Expiration 10/31/18 Owner Bass Farms Inc SOC Effective Expiration Facility Bass Farms Inc-Bass Fms Saus County Nash 6685 Hwy 64 E Region Raleigh Spring Hope NC 278820126 Contact Person John R Bass Title Phone 252-478-4147 Directions to Facility System Classifications SI, Primary ORC Brent W Edwards Certification 24268 Phone 252-478-4147 Secondary ORC(s) On-Site Representative(s) Related Permits Inspection Date 04/23/2018 Entry Time 02 OOPM Exit Time 03 OOPM Primary Inspector Raymond M Milosh Phone 919-715-0588 Secondary Inspector(s) Reason for Inspection Routine Inspection Type Compliance Evaluation Permit Inspection Type Wastewater Irrigation Facility Status • Compliant 0 Not Compliant Question Areas ® Miscellaneous Questions • Treatment ® Record Keeping IN Treatment Lagoons ® End Use-Irrigation ® Storage (See attachment summary) Page 1 Permit. W00002004 Owner-Facility Bass Farms Inc Inspection Date 04/23/2018 Inspection Type Compliance Evaluation Reason for Visit Routine Inspection Summary Staff of the NC Division of Water Resources(DWR),Water Quality Regional Operations Section inspected the subject wastewater irrigation system on April 23,2018 I wish to thank you and Otto Deans for your help during the inspection The purpose of the visit was to conduct a compliance inspection of the system The permit was issued on November 1,2013 and expires on October 31, 2018 Please begin the process of renewing the permit The facility averages 5500 to 5800 gpd of the 8500 gpd permitted Flow from the incoming freshwater meter is used as an estimate of flow through the wastewater treatment system Fields 1,2,and 3 are in woods and are barely used as the ground stays wet most of the year Fields 4 and 5 receive about 5"of the 24"permitted with a travelling gun The pump used to operate the travelling gun stays at the side of lagoon 2 To prevent damage and theft,the piping and the gun are stored behind a locked gate after each use About 50 lbs of the 200 lbs PAN permitted is applied to the fields Hay is harvested off the fields several times a year Domestic waste produced at the facility is treated by a separate on site system Grease is skimmed off the grease trap weekly The grease trap is pumped out as necessary Both pumps in the aeration basin were in working order The aeration basin was pumped out during a plant shutdown 3 years ago and concrete was poured around the perimeter on the outside because the steel walls were failing The pump and alarm in the pump tank were working Effluent flows to a pump tank and is pumped to the eastern lagoon The float, light and alarm were tested and found to be in working order Wash water from the hog holding pen drains to a second pump station The pump,float, and alarm were in working order This station pumps to lagoon 1 The aerator in one lagoon was down for repair The surface aerators are reportedly susceptible to motor damage and gearbox damage during freezing conditions in winter Replacement with subsurface aerator or installation of a thermal overload switch may be considered to eliminate the problem in the future The pump house between the lagoons contains 2 pumps, both in working order The western lagoon rarely needs to be pumped Freeboard was approximately 3 ft 10 inches in lagoon 1 and 3 ft 3 inches in lagoon 2 Sprayfield maintenance and operation records were in good order NDAR's and NDMR's have been submitted complete and on time Soil samples were collected in March 2017 pH records did not indicate a need for lime Three sprayfields are planted in trees(1, 2 and 3) Trees are periodically removed to encourage growth of grass One field was operated and the four sprayheads were in good working order Neither the pump nor the gun were operated during the inspection Two monitoring wells are present and locked at the north and south end of field 3 Groundwater monitoring is not required by the current permit The Wastewater Surface Irrigation System appears to be well maintained and in compliance with permit conditions Please see the attached Inspection Report Page 2 1# Xk D O y w D D v D > > > �, 71 C) 0. D r cn D D x cn D �7 3 61 0 o Cn m _0 D co O cD G) m c3 G7 cD m m c3 m g 0 o m CD co 7 T 0 0 5 . CD =c Q Q n1 -oa Q m 7 = °> co o o o 0 °' —I .�., 0 CD m SCi 0 CD < m d o _ SCA m m _ m o C co m v g g = -o a -' rn 3 m m m 1t CD g S 7' S m CD �` 4- D C cD .7. co co CU 3 Z - CD CD SD CD cc) co C1 Q N C1 p 7 N CDm N cnZ v _ y D m 3 o m m m O ... o m rt D' 3 ... 3 Cn cn CD 3 W co CD CD (D o oCD N O d C) 7 U CD N D 7 C) CD cD N `< C C C .0 C N `< Ft fn in y 7 S - O O O 3 N `< , O O N to .L7 cQ C B cD 7. `_< C2 C1 CA 0. m PI - 7 7 J .7. 0 co co CD Cn co O a v coi m N y v CD n r co m m Co El j .0 C n -a m m 'o N 3 v o o. Q D. .[z Cl)13 7 N c0 co 7 7 CO CD N N 3 -0 I- W - m d m Fol m a = < y ni o m Q- o m o O m 3 v o I 7 r A D N o O' 7 'O 07 a N 3 o = CO N co 7 I �7 ` o cD .J N X fD 3 Q 0 W CD G N m " O 'O FLI F/3 Fp' J d 6 O O < N C O" ,7Di to O O C1 7 CD CD Co O O = O 7 3 O CD m 0 a cD J CD J CD d y co J 6 0 CD CD Lr CD Q 3 T.7 Q CD CD CD A Q Q J Q 0 O CD O C - O- O- J O g = = < 6; p, m CD a. 0 O O X co S O Z — cn N O J -a �C J J -00 3 Fs ai 7 N CU - 0 CA 7 CD al J oi CD 0 n Q c'' O co J Q J c J cn J .- - CD 0 = - J J CD -^ 7 7 d J COcri O _ CD 7 7 y0 y C CD N CCii CS ^ 3 CD O O C 7 71 O "' if CL * (D K .7 V J v 0 CD 11-i 0 CP o no 3 N J v T N co n 3 CD N < o C O CD CD N 0 O 7 O G N • • • • 01=111111111 • 0001=1 • • • • • • N ■ ■ N • 000001:100 N O 0.1 I=1 1:1 I=10 El 1=I0 El 1=I 1=10 El 1=I 1=1 El ID El ❑ Z El ❑ Z 0 Ca Z CD ❑ ❑ ❑ ❑ 11 ❑ ❑ ❑ ❑ • • • ❑ ❑ ❑ ❑ ❑ ❑ Z DD Z 1.z ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ m 00 m m Permit WQ0002004 Owner-Facility Bass Farms Inc Inspection Date 04/23/2016 Inspection Type Compliance Evaluation Reason for Visit Routine Are Operational and Maintenance records present? • 0 0 0 Were Operational and Maintenance records complete? • El El 0 Has permittee been free of public complaints in last 12 months? • 0 ❑ El Is a copy of the SOC readily available? 0 ❑ • ❑ No treatment units bypassed since last inspection? • El El El Comment End Use-Irrigation Yes No NA NE Are buffers adequate? • ❑ ❑ 0 Is the cover crop type specified in permit? • El El 0 Is the crop cover acceptable? ® ❑ ❑ ❑ Is the site condition adequate? ® ❑ ❑ 0 Is the site free of runoff/ponding? • ❑ ❑ 0 Is the acreage specified in the permit being utilized? • ❑ 0 0 Is the application equipment present? • 0 El ❑ Is the application equipment operational? • El El 0 Is the disposal field free of limiting slopes? • El 0 ❑ Is access restricted and/or signs posted during active site use? • ❑ El El Are any supply wells within the CB? El ❑ ® ❑ Are any supply wells within 250' of the CB? ❑ El IN ❑ How close is the closest water supply well? 0 ❑ • ❑ Is municipal water available in the area? El El • ❑ #Info only Does the permit call for monitoring wells? • ❑ El El Are GW monitoring wells located properly w/respect to RB aid CB? 0 ❑ El • Are GW monitoring wells properly constructed,including screened interval? ❑ El El • Are monitoring wells damaged? ❑ 0 • 0 Comment Page 4